BLUE WEAR 906178 A1 Filter 2-pk Instructions

June 4, 2024
BLUE WEAR

BLUE WEAR logo

BLUE WEAR 906178 A1 Filter 2-pk

SAFETY INSTRUCTIONS

  • Users must be instructed in the use of filters and must be capable of using a breathing apparatus.
  • The type and concentration of toxic substances must be known.
  • Make sure that the ambient conditions cannot deteriorate during the time spent in the dangerous area. In such cases a breathing apparatus must be used.
  • Filters are not a reliable method of protection if there are
  • Contaminants that cannot be noticed by smel, taste, irritation of the eyes or the respiratory channels. Use other types of protection in such cases. Follow any special regulations.
  • Gas filters do not provide protection from particles, and particle filters do not provide protection from gas. Use combination filters in doubtful cases.
  • Do not use the filter after the specified expiry date or after 6 month if the package has been opend.
  • Improper use can cause serious personal injury, health problems or death.

WARNING!

  • Double gas filter for use in half mask 906179 without fan assisted air supply.
  • Follow the instructions for half mask 906179 as well.

SYMBOLSBLUE WEAR 906178 A1 Filter 2-pk 1

REGULATIONS AND STANDARDS

  • (EU) 2016/425-Regulation for personal protective equipment (PPE).
  • EN 14387:2008 – Breathing mask – Gas filter and combination filter.

TECHNICAL DATA

This product is CE marked to demonstrate compliance with the directive (EU) 2016/425 for personal protective equipment and complies with the standard EN 14387:2008. Notified Body No 0121 Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (IFA) Prüf- und Zertifizierungsstelle im DGUV Test, Alte Heerstralße 111, D-53757 Sankt Augustin, Germany.BLUE WEAR 906178
A1 Filter 2-pk 2

DESCRIPTION

MARKINGs ON BREATHING FILTER

  • Filter marking A1 (colour code brown).
  • Class 1, for use with low capacity cartridge for filtering of organic gas/vapour with boiling point over 65°C.

CRITERIA FOR SELECTION OF FILTER UNITBLUE WEAR 906178 A1 Filter 2-pk
3

USE

HOW TO USE

  •  Check packaging and filter before use. Do not use the filter if there are any signs of damage or holes in the packaging or diaphragm, IT the filter is deformed, or is cracked or otherwise damaged.
  •  Read these instructions carefully before use and make sure that the person using the filter fully understands all the instructions.
  • Replace the filter cartridge immediately when it feels more difficult to breathe.
  • The cartridge only provide protection from some gases. Use the filter marking to select a suitable filter.
  •  Do not replace a filter cartridge in a contaminated area.
  •  Release the fastener, screw the filter cartridge on the half mask and check the tightness before use.

NOTE:
Facial hair and scars ett. can result in inferior tightness.

LIMITATIONS

  • Do not use the filter cartridges in the following circumstances:
  • When there is an increase in the oxygen content or when the concentration exceeds 23.5%. The increase in the oxygen content can be very dangerous. The limit is not definite, but even a moderate increase in the content increases the risk. An increase in the oxygen content means that sparks are a greater fire hazard, and that a fire would be more intense.
  • With concentration higher than 0.1% of harmful gas. In areas where there is a risk of explosion. In the vicinity of naked flame, molten metal or splashing of molten metal, or other source of heat that risks igniting the active carbon in the filter, which can produce a harmful content of CO or CO
  • The oxygen content in the inhaled air must not be less than 19%.
  • Never enter unventilated tanks, pits, channels or small spaces with filtered breathing protection. In such cases a breathing apparatus must be used
  • Filters and filter sets heavier than 300 g must only be used with a half tace mask.

CHECK

Check all plastic and rubber parts for cracks and fatigue damage. Check that the breathing filter is correctly fitted and in good condition. This type of filter cartridge does not require any maintenance.

MAINTENANCE

CLEANING AND STORAGE

  • Remove the breathing filter from the mask after use and store separately.
  • The breathing filter does not need to be cleaned.
  • Store chemical breathing filters in an airtight container when not in use so they are protected from moisture.
  • Dispose of used filter cartridges in accordance with local regulations.
  • Pay attention to the storage time and date of expiry. The product can not be used 6 months after the package as been opened.

FITTING AND REPLACING BREATHING FILTERS

Suitable for half mask model 906179.

  •  Align the cartridge to the base of the mask and fit together.
  •  Turn the filter clockwise until it stops.
  •  Remove the cartridge by turning it anticlockwise.
  •  When double filters are used, always replace both filters at the same time. Both filters must always be of the same filter class.

NOTE:
The mask has two filter cartridges.

IMPORTANT:
Twin/double filters must always be replaced in pairs and two filters in the same filter class must always be used.

USEFUL LIFE OF BREATHING FILTERS

The chemical breathing filter must be used before the expiry date, which is given on the pack. The useful life of the product is affected by the following factors. The activity of the user and breathing rate. The type, viscosity and concentration of the contaminating substance. Environmental conditions such as humidity, air pressure and temperature. Correct handling of the product. Replace the filter immediately if the user detects the smell of the contaminating substance or other strong smell.