acaia AL008 Lunar Digital Scale User Manual

June 12, 2024
acaia

AL008 Lunar Digital Scale

Product Information

The Acaia Lunar is a scale designed and manufactured to the
highest standard to provide the best coffee brewing experience. It
comes with various features and accessories to enhance your brewing
process.

In the Box

  • Acaia Lunar scale
  • Heat Resistant Pad
  • USB Type-C Charger Cable
  • Acaia Calibration Weight 100 g

Scale Overview

The Acaia Lunar scale features a weighing pan, power button, LED
display, and tare button. For optimal performance, place the weight
in the center of the weighing pan.

Product Usage Instructions

Getting Started

Placement

Place the scale on a stable and vibration-free surface in a
horizontal position.

Power On/Off

To turn on the scale, press the power button. Double-tap the
power button to turn off the scale.

Tare Weight

To zero the weight, press the tare button.

Switch Mode

To switch between modes, press and hold the power button. Refer
to the Mode Introduction section for more details on each mode.

Product Care Information

Battery Charge

Ensure the battery is charged for optimal performance.

Battery Level Indicator

The battery level indicator will be displayed when powering off
or accessing settings.

Calibration

  1. Turn on the scale.
  2. Tap the “T” button.
  3. Check the display for the “CAL” indication.
  4. Place a weight on the scale.
  5. Wait until the display shows “End”.

The calibration process is now complete. You can use Acaia
weights or other F2 class standard calibration weights of 500 g,
1000 g, or 2000 g.

Care and Cleaning

Follow the provided instructions to clean and maintain the
scale, taking care not to damage the anodized coating.

Flow-Rate Indicator

The Flow-Rate Indicator can be enabled to provide easier reading
of flow-rate values. Each marking represents an increment of 0.5
g/s, with the highest marking indicating 4.0 g/s. Refer to the
Configuration section for instructions on enabling this
function.

Brewing with Flow-Rate Indicator

To start brewing, place a cup on the scale. During an espresso
brew, the Flow-Rate Indicator will display the highest peak
flow-rate with a single bright LED. The LED will remain on the
display throughout the brew.

Acaia Lunar User Manual
AL008 / AL009 / AL010

FW 1.0.009

Contents

3 In the Box

3

Introduction

3

Scale Overview

4 Getting Started

4

Placement

4

Power On/Off

4

Tare Weight

4

Switch Mode

5 Product Care Information

5

Battery Charge

5

Battery Level Indicator

5

Calibration

5

Care and Cleaning

6 Flow-Rate Indicator

7 Brewing with Flow-Rate Indicator

8 Tare Save

9 Mode Introduction

9

Mode 1 – Weighing Mode

9

Mode 2 – Dual Display Mode

10

Mode 3 – Timer Starts with Flow Mode

11

Mode 4 – Auto-Tare Timer Starts with Flow Mode

12

Mode 5 – Auto-Tare Auto-Start Timer Mode

13

Mode 6 – Auto-Tare Mode

15

Configuration

20 Appendix

20

Buttons

21

LED Indicators

22

Error Codes

22

Other

23

Specifications

In the Box
Introduction
Thank you for choosing our scale. The Acaia Lunar is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience. Start by checking your Acaia Lunar box to find the following:

Acaia Lunar

Heat Resistant Pad

USB Type-C Charger Cable

Acaia Calibration Weight 100 g

Next, follow the instructions in Getting Started to begin using your scale. To take full advantage of the Lunar’s many features, carefully read through the manual, which contains step-by-step procedures, examples, and other information.
Warning: Incorrect handling of this product could result in personal injury or physical damage.

Scale Overview

Weighing Pan Power Button

LED Display Tare Button

*Note: For the best performance, place the weight in the center of the weighing pan.

3

Getting Started

Placement

Place the scale on a stable and vibration-free surface at a preferably horizontal location.

Power On/Off
[Press] to turn on the scale. [Double tap] to turn off the scale.
Tare Weight
[Press] to tare/zero the weight.

Switch Mode
[Press and hold] to switch modes. * Please see the “Mode Introduction” section for more details.

4

Product Care Information
Battery Charge
· You can charge the battery by plugging the USB cable into any of the power supplies listed below: · A computer · A USB wall-charger with an output of 5 volts and 1 amp · A DC car-charger with an output of 5 volts and 1 amp
· It takes about 1-2 hours to fully charge the battery from empty. Try not to let the battery completely run out before charging. Charge as needed.
· To check remaining battery level, see below for Battery Level Indicator.
Battery Level Indicator

When powering off

When accessing settings

· When powering off the scale, the Battery Level Indicator can be seen on the top of the display. · You can also check the battery level in the main settings menu. When the scale is powered
off, press and hold the Power button, the LED display will show [ ACAIA ] and then changes to [ SEt ]. Continue holding the Power button until the battery percentage is displayed. · You can also check the battery level by connecting the scale to Acaia Apps.

Calibration

Turn on scale

Tap T button

See CAL display

Place a weight

Turn on the Acaia scale.

Make sure the scale is in weighing mode and the unit is set to gram’, then tap the T’ button rapidly.

Keep tapping the T’ button untilCAL’ is
shown on the display.

Place a weight on the scale and wait until the display shows `End’.
Calibration is now complete!

Note: You may also use 500 g, 1000 g or 2000 g weights. If you use weights other than Acaia Weights, we recommend F2 class standard calibration weights.

Care and Cleaning
· Use a soft cloth with warm water only to clean the product. · Do not use detergent or other chemicals for cleaning and soaking as it can damage the
anodized coating on the product.
5

Flow-Rate Indicator
The Flow-Rate Indicator is an LED bar on the top of the display. It helps you visualize your espresso flow-rate in real time and spot channeling during brewing. The indicator measures flow-rate with lit LEDs starting from 0.1 g per second on the left to 3.4 g per second on the right. When the flow-rate exceeds 5.0 g per second, the last three LEDs will light up with enhanced brightness, indicating a high flow-rate. During an espresso brew, the Flow- Rate Indicator will display the highest peak flow-rate of this brew with a single bright LED. The Flow-Rate Indicator can be activated in all modes. You can turn the indicator on or off in the advanced settings menu.
You can also enable markings on the Flow-Rate Indicator for easier reading of the flow-rate value. Each marking indicates an increment of 0.5 g/s for the current flow-rate, and the highest marking is 4.0 g/s. Note: To enable this function, please see Flow-Rate Indicator in the Configuration section (p.15).
6

Brewing with Flow-Rate Indicator
Place a cup on the scale to start brewing.

The highest peak & Real flow-rate

During an espresso brew, the Flow-Rate Indicator will
display the highest peak flow-rate of this brew with a single bright LED.

The highest peak flow-rate LED will stay on the display during an espresso brew.

Real flow-rate

The highest peak flow-rate

When brewing is completed, the highest peak flow-rate LED will stay on the display.
The highest peak flow-rate

Average flow-rate

The highest peak flow-rate

When brewing is completed and the cup is removed
from the scale, the display will flash to show the final beverage weight and the average flow-rate of the brewing. The Flow-Rate Indicator will show the average
flow-rate with a stripe LED and the highest peak flow-rate with a single bright LED.

The highest peak flow-rate

7

Tare Save
If you have a frequently used container in your weighing workflow, you can save the weight of the container using the Tare Save function. This will allow you to weigh the container with contents, then trigger Tare Save to deduct the container weight and obtain the net weight. The Tare Save function can be activated in Weighing mode and Dual Display Mode.
Save Container Weight

1 Place a container on the scale.

2 Press and hold Tare button for 2 seconds when reading is stable. The weight is stored as a preset container weight.

Tare Container Weight Using Tare Save

3 You may continue using your scale.

1 Place a container along with its contents on the scale.

2 Press and hold Tare button for 0.5 second. The scale will display the weight to be deducted.

3 The net weight is displayed on the scale.

· To save a new container weight, place the desired container on the scale, then press and hold Tare button for 2 seconds. This will register a new preset container weight.
· It is only allowed to tare container weight once, if you press and hold Tare button for 0.5 second again, the scale will display [ CUP ] and the preset container weight, but the cointainer weight will not be tared again.

Action Save Container Weight Subtract Container Weight

Operation Press and hold Tare button for 2 seconds Press and hold Tare button for 0.5 second
8

Mode Introduction
Mode 1 – Weighing Mode
In the Weighing Mode, the scale will only display weight, in either grams or ounces.

· There are two different weighing units in Weighing Mode: gram and ounce. · In grams, the LED display shows [ 0.0 ]. · In ounces, the LED display shows [ 0.000 ] and the Weighing In Ounces Indicator on the
bottom left lights up. · The readability is 0.1 g or 0.002 oz. For high resolution mode, the readability is 0.01 g or
0.0005 oz. · The Tare Save funtion is supported in this mode.

Action Tare Weight Switch Mode

Operation Tap Tare button Press and hold Power button

Note :
To change the weighing unit to either gram or ounce, please see Default Unit Setting in the Configuration section (p. 15).

Mode 2 – Dual Display Mode
In the Dual Display Mode, the scale displays [ 0:00 0.0 ] with a timer (left) and weight (right).

· There are two different weighing units in Dual Display Mode: gram and ounce. · In grams, the LED display shows [ 0:00 0.0 ]. · In ounces, the LED display shows [ 0:00 0.000 ]. · The timer displays from [ 0:00 ] to [ 9:59 ] and then stops. · The Tare Save funtion is supported in this mode.

Action Start/Stop/Reset Timer Tare Weight Switch Mode

Operation Tap Power button Tap Tare button Press and hold Power button

9

Mode 3 – Timer Starts with Flow Mode – Droplet
When the scale detects the flow of espresso, the timer starts. The timer will stop when the flow stops.
*Please note: The flow detection mode is designed to detect the slow trickle of a shot of espresso. The timer may not trigger when attempting to pour from a kettle.
Display · In grams, the LED display shows [ 0:00 0.0 ]. · In ounces, the LED display shows [ 0:00 0.000 ].
Mode Description · The timer starts when the flow of espresso is detected. · When the espresso flow stops, the timer stops.

1 The droplet icon indicates that you are in Timer Starts with Flow Mode.

2 Place a cup on the scale and tare the weight manually.

3 The timer starts when the flow of espresso is detected.

4 The timer will stop automatically when the espresso flow stops or the cup is removed.

Action Start Timer Tare Weight Stop Timer Reset Mode Switch Mode

Operation The timer will start when the flow is detected Tap Tare button The timer will stop when flow is no longer detected Double tap Tare button Press and hold Power button

10

Mode 4 – Auto-Tare Timer Starts with Flow Mode Droplet and Square
This mode is designed for baristas who would like to measure the time of the shot starting from the first few drops of espresso. When the weight reading is stable, the scale will perform the auto-tare operation. After the scale detects the espresso flow, the timer starts automatically. The timer will stop automatically when the espresso flow stops.
Display
· In grams, the LED display shows [ 0:00 0.0 ]. · In ounces, the LED display shows [ 0:00 0.000 ]. · The timer displays from [ 0:00 ] to [ 9:59 ] and then stops.
Mode Description
· The auto-tare function operates when a stable weight is placed on the scale. · The timer will start automatically when the flow of espresso is detected.

1 The droplet and square icon indicate that you are in Auto-Tare Timer Starts with Flow Mode.

2 Place a cup on the scale, and it will perform auto-tare.

3 The timer starts when the flow of espresso is detected.

4 The timer will stop automatically when the espresso flow stops or the cup is removed.

Action Start Timer Tare Weight Stop Timer Reset Mode Switch Mode

Operation The timer will start when the flow is detected Tare function starts when a stable weight is placed on the scale The timer will stop when flow is no longer detected Double tap Tare button Press and hold Power button

11

Mode 5 – Auto-Tare Auto-Start Timer Mode Triangle and Square
This mode is for baristas to measure the total time of a shot including the pre-infusion time. After a cup is placed on the scale and the weight reading is stable, the scale performs auto-tare and starts the timer.
Display · In grams, the LED display shows [ 0:00 0.0 ]. · In ounces, the LED display shows [ 0:00 0.000 ]. · The timer displays from [ 0:00 ] to [ 9:59 ] and then stops.
Mode Description
· The scale performs auto-tare once a stable weight is detected, then the timer starts. · The timer stops when the espresso flow stops.

1 The triangle and square icon indicate that you are in Auto-Tare Auto-Start Timer Mode.

2 Place a cup on the scale. The scale will perform auto-tare and start the timer.

3 Scale will measure the total time of a shot including the pre-infusion time.

4 The timer will stop automatically when the espresso flow stops or the cup is removed.

Action Start Timer Tare Weight Stop Timer Reset Mode Switch Mode

Operation The timer will start when a stable weight is placed on the scale Tare function starts when a stable weight is placed on the scale The timer will stop when flow is no longer detected Double tap Tare button Press and hold Power button

12

Mode 6 – Auto-Tare Mode – Square
In this mode, the scale will only perform auto-tare. Put the cup on the scale and auto-tare will be performed. Pull the shot of espresso as you normally would. When the cup is removed from the scale, the espresso brewing summary will be displayed.
Display · The LED display shows [ 0.0 ] with the weight in grams. · The LED display shows [ 0.000 ] with the weight in ounces.
Mode Description · The scale performs auto-tare once a stable weight is detected.

1 The square icon indicates that you are in Auto-Tare Mode.

2 Place a cup on the scale for auto-tare.

3 Start brewing.
Action Tare Weight Reset Mode Switch Mode

4 The final beverage weight will be displayed when brewing is complete.
Operation Tare function is performed when a stable weight is placed on the scale Double tap Tare button Press and hold Power button

13

Timer Auto Stop

In all three Auto-Start Modes ( ,

,

or when the cup is removed from the scale.

), the timer will stop when the espresso flow stops

or
Espresso Brewing Summary
In all Auto Modes (including Auto-Tare Mode), when brewing is complete and the cup is removed from the scale, the display will flash to show the final beverage weight and the average flow rate of the brewing.

Auto-Reset
If the scale remains idle for 30 seconds, it will reset the timer and perform the tare operation. This feature is ideal for streamlining bar workflow. The scale automatically resets after the cup has been removed, eliminating the need for pressing buttons.
Note: To change this reset time, please see Auto-Reset Setting in the Configuration section (p. 15).

14

Configuration

Enter Settings
1. With the Lunar powered off, press and hold the Power button. When the LED display shows [ ACAIA ] and then changes to [ SEt ], release the Power button.
2. Tap the Tare button to enter Settings. The first setting is [ SLEEP ]. 3. Please refer to the following table for key operations.

Action Next Setting Enter Setting Toggle Options Save Option Back to Menu Without Saving Exit Settings and Return to Modes

Operation Tap Tare button Press and hold Tare button Tap Tare button Press and hold Tare button Tap Power button Tap Power button

15

Settings Menu
Settings Sleep Timer Setting Brightness Setting Battery Saving Setting Default Weighing Unit Setting Key Sound Setting Weighing Mode Setting Dual Display Mode Setting Timer Starts with Flow Mode Setting Auto-Tare Timer Starts with Flow Mode Setting Auto-Tare Auto-Start Timer Mode Setting Auto-Tare Mode Setting Flow-Rate Indicator Setting Average Flow-Rate Setting Weight Stable Indicator Setting Auto-Reset Setting Pre-infusion Time Out Setting Auto-Start Sensitivity Setting Weighing Resolution Setting Weighing Filter Setting Zero Tracking Setting Zero Range Setting Bluetooth Setup Setting Reset to Default Setting

Display SLEEP bright bAttSavE Unit bEEP NOdE_1 NOdE_2 NOdE_3
NOdE_4
NOdE_5 NOdE_6 FLorAtE. d Avg. FLo StAbLE. d Auto_rES PrE_inFu SEnSE rESoL FiLtEr trAcE 0. rAnGE bt _SEt rESE t. d

Sub-Menu Options 5, 10, 20, 30, 60, Off 1, 2, 3, 4 30, 90, 180, Off Gram, Ounce On, Off On, Off On, Off On, Off
On, Off
On, Off On, Off Default, Grad, Off On, Off On, Off Off, 10, 30 10, 30, 60, 120 0.1, 0.2, Off Default, High Fast, Normal, High 0.5 d, 1 d, 2 d, 3 d, Off 2., 100. On, Off No, Yes

Default 5 2 90
Gram On On On On
On
On On Default On Off 30 60 Off Default Fast 1 d 100 On No

16

Sleep Timer Setting [ SLEEP ] 1. Sleep Timer setting can also be configured in the Acaia apps. 2. The number indicates the amount of time before the scale automatically powers off. For
example, when 10 is selected, the scale powers off after 10 minutes of being idle if the scale is
disconnected from all mobile devices.

Brightness Setting [ bright ] 1. The default setting is 2. 2. You can adjust the brightness of the LED display. Set to 4 when operating under strong light,
such as when outdoors.

Battery Saving Setting [ bAttSAvE ] 1. Save up to 20% of your battery by dimming the display after some time. It will return to its original brightness when the scale detects objects on it.
2. The number indicates the amount of time in seconds before the scale enters battery saving mode.
3. Tap the Tare button to toggle through the options.

Default Unit Setting [ Unit ] The Default Weighing Unit is set to grams if [ 9 ] is selected and ounce if [ o2 ] is selected.

Key Sound Setting [ bEEP ] 1. Key Sound setting can also be configured in the Acaia apps. 2. Set the Key Sound function to on/off to enable/disable the beeping sound.

Weighing Mode Setting [ NoDE_1 ] The default setting is On.
· On: Mode enabled. · Off: Mode disabled.

Dual Display Mode Setting [ NodE_2 ] The default setting is On.
· On: Mode enabled. · Off: Mode disabled.

Timer Starts with Flow Mode
The default setting is On.
· On: Mode enabled. · Off: Mode disabled.

Setting [ NodE_3 ]

Auto-Tare Timer Starts with Flow Mode
The default setting is On.
· On: Mode enabled. · Off: Mode disabled.

Setting [ NodE_4 ]

Auto-Tare Auto-Start Timer Mode
The default setting is On.
· On: Mode enabled. · Off: Mode disabled.

Setting [ NodE_5 ]

17

Auto-Tare Mode
The default setting is On.
· On: Mode enabled. · Off: Mode disabled.

Setting [ NodE_6 ]

Flow-Rate Indicator Setting [ FLorAtE.d ] 1. This is automatically set to Default.
2. Default: Flow-Rate Indicator enabled. The Flow-Rate Indicator on the top of the display turns on and visualizes your espresso flow-rate in real time.
3. Grad: Flow-Rate Indicator and Flow-Rate Markers enabled. The markers will turn on when brewing. Every marker represents a 0.5g/s increment in flow-rate.
4. Off: Flow-Rate Indicator disabled.

Average Flow-Rate Setting [ Avg.FLo ] 1. The default setting is On.
2. On: Average Flow-Rate enabled. When brewing is complete and the cup is removed from the scale, the display will show the espresso summary with the beverage weight and the average
flow-rate of brewing. 3. Off: Average Flow-Rate disabled. When brewing is complete and the cup is removed, the
display will show the espresso summary with the beverage weight and the current weight.

Weight Stable Indicator Setting [ StAbLE.d ] 1. The default setting is Off. 2. On: Weight Stable Indicator enabled. The Weight Stable Indicator on the bottom left of the
display lights up when the weight is stable. 3. Off: Weight Stable Indicator disabled.

Auto-Reset Setting [ Auto_rES ] 1. After a cup is removed, the timer and weight will automatically reset. This setting gives you options on how long to wait for the reset. It enables the user to pull successive shots of espresso quickly in the three Auto-Start modes.
2. The number indicates the timeout value in seconds of timer reset after a cup is removed.

Pre-Infusion Time Out Setting [ PrE_inFu ] 1. Determines when the scale times out in Auto-Start mode and two Auto-Start modes when the timer is manually started. This is most useful for long pre-infusion times and resolves the timeout issue that sometimes happens for slower pre-infusions.
2. The number indicates the time in seconds it will take for the scale to reset if no espresso flow or weight is detected.

Auto-Start Sensitivity Setting [ SEnSE ] 1. Minimum weight is decreased for more sensitivity. This is ideal for slower espresso shots in the modes. Stability depends on environmental noise.
2. The number indicates the sensitivity of flow detection in the modes. A smaller value indicates higher sensitivity, but is recommended only for stable working environments.

18

Weighing Resolution Setting [ rESoL ] 1. The Weighing Resolution is automatically set to [ dEFAUL ]: the division is 0.1 g/0.002 oz. 2. Tap the Tare button to switch the Weighing Resolution between [ dEFAUL ] and [ hiGh ]. 3. When the Weighing Resolution is set to high, the division will be 0.01 g/0.0005 oz. The default
display will show [ 0.00 ] when the scale is set to grams, and [ 0.0000 ] for ounces in Weighing Mode.
Note: After setting Weighing Resolution to high, the default display will show [ 0:00 0.00 ] with timer in Dual Display Mode and Auto Start Modes.
Weighing Filter Setting [ FiLtEr ] 1. The Weighing Filter Setting determines the speed at which the load receptor responds to weight and determines the weighing value. The larger the number, the more stable but slower the weighing result will be. The number shown on the LED display indicates the current filter setting.
2. Press the Tare button to change the parameter.
Zero Tracking Setting [ trAcE ] 1. Zero Tracking is a function for automatically maintaining the zero indication within certain limits. 2. Off: It is not recommended to turn off Zero Tracking because the zero indication can drift easily as
the room temperature changes. 3. 0.5 d~3 d: For example, for standard resolution each division is 0.1 g, 3 d = 0.3 g. When Zero
Tracking is set to be 3 d, any initial weight between ± 0.3 g on the weighing pan will be zeroed out gradually. 4. 2 d is recommended in general for the Acaia Lunar.
Zero Range Setting [ 0.rAnGE ] 1. The Zero Range Setting determines the range for which the Tare button executes zero operation instead of tare operation.
2. When Zero Range is set to 2, the range for zero-setting will be 2% of the capacity, i.e., ± 40 g for Acaia Lunar. By pressing the Tare button, any weight within ± 40 g is zeroed out by zero operation while any weight that lies outside the range is tared out by tare operation.
3. If Zero Range is set to 100, the range for zero-setting will be 100% of the capacity, i.e., ± 2 kg for Acaia Lunar. Therefore, instead of tare operation, zero operation would be executed in this setting whenever the Tare button is pressed.
Notice: The difference between zero operation and tare operation is that zero operation would simply ignore the weight and display as 0 while tare operation would deduct the weight from the weighing result. However, zero operation does not increase the scale capacity.
Bluetooth Setup Setting [ bt_SEt ] 1. Off: Bluetooth disabled. The scale does not allow any Bluetooth connection. 2. On: Bluetooth enabled. The scale allows Bluetooth connection. The user may connect the scale
with Acaia apps.
Reset to Default Setting [ rESEt.d ] Select [ YES ] to reset all settings to default value.
19

Appendix

Buttons

Power Button
Tare Button

Function Turn On Turn Off Switch Mode Start / Stop / Reset Timer Back Tare Tare and Reset Timer
Save / Subtract
Switch Option
Confirm Enter Calibration Mode

Example
Press and hold for 0.5 seconds to turn on the scale.
Double-tap to turn off the scale.
While the scale is turned on, press and hold for one second to switch modes.
Tap to start/stop/reset timer.
While in Settings Menu, tap to go back to Modes.
Tap to tare weight.
While in Auto-Start Modes, double tap to zero weight and reset timer.
Press and hold for 2 seconds to save the container weight. Press and hold for 0.5 second to subtract the saved container weight.
While in Settings, tap to scroll through sub-menus. While in sub-menus, tap to toggle options.
While in Settings, press and hold for two seconds to confirm the option selected in a sub-menu.
While in Weighing Mode, rapidly tap to enter Calibration Mode.

20

LED Indicators

Charging / Low Battery Indicator
Bluetooth Connection Indicator
Weight Stable Indicator
Weighing in Ounces / Data Transmitting Indicator
Power Button

Button Pressed Indicator Auto-Start Timer Indicator (Flow) Auto-Start Timer Indicator (Tare)
Auto-tare Operation
Tare Button

Charging / Low Battery Indicator This indicator turns on when the battery is charging and turns off once the battery is fully charged. The indicator starts flashing when the battery power is low as a reminder to charge the scale.

  • Note: The Acaia Lunar is equipped with charging protection to prevent the battery from charging under high temperatures. It is normal if the scale does not charge when the surface is hot from brewing coffee. Battery charging function will be enabled once the scale has cooled.
    Bluetooth Connection Indicator This indicator turns on when the scale is connected to Acaia Apps.
    Weight Stable Indicator This indicator turns on when the weight is stable.
    Weighing in Ounces / Data Transmitting Indicator This indicator turns on when the weighing unit is in ounces. The indicator also lights up during software update to indicate data transfer.
    Button Pressed Indicator This indicator turns on when a button is pressed.
    Auto-Start Timer with Flow Indicator When the scale detects the flow of espresso, the timer starts. The timer will stop when the flow stops. *Please note: The flow detection mode is designed to detect the flow of espresso. The timer may not trigger when attempting to pour from a kettle.
    Auto-Start Timer with Tare Indicator The scale performs auto-tare and simultaneously starts the timer when a stable weight is placed on the weighing pan.
    Auto-Tare Indicator The scale performs auto-tare when a stable weight is placed on the weighing pan.

21

Error Codes

Error Code 100 101 102 303
304 904 H2O H2O H2O

Description Access Code Error, unrecognized access code. EEPROM error, unable to access memory. Please contact Acaia support. AD error, unable to access weighing signal. Please contact Acaia support. Unable to find acceptable starting Zero point, most likely due to loadcell damage caused by excessive force or drop. Please contact Acaia support. Over load: the weight is over the maximum capacity. Under load: the weight is under the minimum capacity. Calibration error. Calibration cannot proceed when environmental noises are too strong. Please calibrate in a stable environment free of wind, vibration, etc. Password error (the default password is 0000). Water in the Power button. Water in the Tare button. Water in the Power button and Tare button.

Other

Display Code Description

UPdAtE

The scale is in update mode. Note: If you want to leave update mode, please connect the scale’s USB to a power source.

22

Specifications

Model Product Weight Product Dimensions Maximum Capacity Minimum Weight Measuring Units Readability Repeatability Linearity Indication Limit Power Supply Battery Battery Life Display Material Surface Connectivity Warranty
Inside the Package

AL008 / AL009 / AL010 265 g ± 5 g W: 105 mm L: 105 mm H: 15 mm 2000 g / 70.55 oz 0.1 g gram, ounce 0.1 g / 0.01 g 0.1 g 1 d (d = 0.1 g) 2060 g / 72.66 oz
5 V / 500 mA Lithium-ion rechargeable 3.7 V 1100 mAh 30-40 hours 8-digit LED Aluminum, Acrylic Anodized aluminum coating (Black / Silver) Bluetooth 5.0 2 Years Acaia Lunar Coffee Scale x 1 Heat Resistant Pad x 1 Non-slip Protective Strip x 2 Friction-reduction Protective Strip x 2 USB Type-C Charger Cable x 1 Acaia Calibration Weight 100 g x 1

23

Copyright
This user manual is protected by copyright. All rights reserved. No part of this manual may be reproduced, processed, duplicated or published in any form by photocopying, microfilming, reprinting or any other method, in particular electronic means, without the written consent of Acaia.
© Acaia, California, 2022.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>