inditech online External Biometric Unit User Manual
- June 9, 2024
- Inditech Online
Table of Contents
- inditech online External Biometric Unit
- Product Information
- Product Description
- Features
- Specifications
- Installation steps
- Wiring/Connection Details
- MOUNTING DETAILS
- CALIBRATION / CONFIGURATION FOR PASSWORD SET AND RESET PROCESS
- . The key # will terminate every operation running on the NUMLOCK. If user
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
inditech online External Biometric Unit
Product Information
Introduction
The External Access Control – Numlock + Biometric is a system used to
provide restricted access to Landing Operating Panel (LOP) and Car Operating
Panel (COP) of an elevator. The aim of this accessory is to provide secured
access to the elevator car by providing numeric digit keypad for password
access and fingerprint scanner based on biometric access systems which
provides high-level security. It is used where the user wishes to have limited
access or authorized person to use the elevator.
Product Name/Model No:
External Access Control – Numlock + Biometric
Product Description
The product provides controlled access to the user of the lift. You can enroll the valid users by configuring their fingerprints. With this device, the lift will be operated only with the valid biometric (fingerprints). For an invalid user, lift buttons are un-operational and lift will not book any floor call. This product also provides Numlock based protection. If the user knows the 4-digit password, he can enter the password number and operate the lift. With the wrong Numlock password, lift will not book any floor call. This device comes as external installation and can be integrated with any Inditech COP/LOP or can be interface with other make COP using a single dry contact. You need to check the specifications of the other make COP/LOP before buying this product.
- This product provides the controlled access to the user of the lift. You can enroll the valid users by configuring their FINGER PRINTS. With this device lift will be operated only with the valid biometric (fingerprints). For invalid user lift buttons are un-operational and lift will not book any floor call.
- This product also provide NUMLOCK based protection. If user knows the 4-digit password, he can enter the password number and operate the lift. With wrong NUMLOCK password, lift will not book any floor call.
- This device comes as external installation and can be integrated with any Inditech COP/LOP or can be interface with other make COP using single dry contact. You need to check the specifications of the other make COP/LOP before buying this product.
Features
- Slim Design with SS FRAME with Shiny attractive ACRYLIC FASCIA.
- High precision capacitive touch buttons.
- Supports 1000+ FINGERPRINTs Numeric Keypad.
- Fast recognition Single dry contact.
- Simple installation and configuration.
- Suitable for Inditech COP. This also can be used for LOP.
- High precision capacitive touch buttons.
- Supports 1000+ FINGER PRINTs
- Numeric Keypad.
- Fast recognition
- Single dry contact
- Simple installation and configuration.
- Suitable for Inditech COP. This also can be used for LOP.
- This product is also suitable any make COP and LOP using Single dry contact.
This product is also suitable for any make COP and LOP using Single dry contact.
Specifications
- Supply voltage : 24VDC
- Relay output : Dry contact (normally open)
- Supports 1000+ fingerprints
- Single dry contact for interface with other make COP
- Suitable for Inditech COP/LOP and other make COP/LOP (Check specifications before purchasing)
- Mount Type- Wall Mount
- Fascia- Black/White
- Input Supply- 24V
- NUMLOCK – Capacitive Touch
- Finger print – Optical biometric sensor
- Size (WHT)-75x225x18MM
- Reliable
- Easy to use
- Elegant and Durable
Product Usage Instructions
Note : Installation and Commissioning of the COP is to be done by an authorized, trained technician of Elevator Company.
Installation steps
Remove the back plate of UNIT.
- Mount the back plate of UNIT on the CAR surface or WALL as per point no.10 MOUNTING DETAILS.
- Give supply 24V, GND to J4 connector pin no. 1 & 2 and PO, NO to pin no. 3 & 4 for button function connection as per above mentioned in point no.7 WIRING / CONNECTION DETAILS.
- Do the calibration process as per point no.8 CALIBRATION CONFIGURATION SET AND RESET PROCESS.
Note : Installation and Commissioning of the COP is to be done by Authorized, Trained technician of Elevator Company. Following are the steps to be taken for the installation of this unit.
- Remove the back plate of UNIT.
- Mount the back plate of UNIT on the CAR surface or WALL as per point no.10 MOUNTING DETAILS.
- Give supply 24V, GND to J4 connector pin no. 1 & 2 and PO, NO to pin no. 3 & 4 for button function connection as per above mentioned in point no.7 WIRING / CONNECTION DETAILS.
- Do the calibration process as per point no.8 CALIBRATION CONFIGURATION SET AND RESET PROCESS.
Wiring/Connection Details
Supply voltage is 24VDC, connect it to Black wire (+24) and Brown wire to Ground. Refer fig-1. Connect the relay output between (Red wire) 3 and (Orange wire) 4. Note that this is dry contact, upon successful operation this contact becomes short. Normally it remains open.
- Supply voltage is 24VDC, connect it to Black wire (+24) and Brown wire to Ground. Refer fig-1.
- Connect the relay output between (Red wire) 3 and (Orange wire) 4.
- Note that this is dry contact, upon successful operation this contact become short. Normally it remains open.
WIRING DIAGRAM OF EXTERNAL NUMLOCK + THUMB
MOUNTING DETAILS
CALIBRATION / CONFIGURATION FOR PASSWORD SET AND RESET PROCESS
You need to do the calibration for access:
CALIBRATION OF NUMLOCK ACCESS SYSTEM
The numeric keypad interface in the access systems is basic and important
feature for restricted access. Which provide access to user for elevators car
by entering correct password. The numeric access system provides user two
features that is accessing the elevator car and to change the user password
for accessing the elevator car. To access the elevator using numeric keypad
interface, user has to enter correct password for the same. The default
password for NUMLOCK access is 1234 terminated by *. The star key is used as
enter key and start key. If the enter password is correct, then LEDs on the
top of Numeric interface will glow blue and beep from COP will generated as
indication of correct password. The LEDs will be kept on for next five
seconds, and user is supposed to book a pre-calibrated floor call in between
this time. Once LEDS goes off, user will not able to book a call for elevator.
Again for the same user has to enter default password. If user enters wrong
password or wrong entry is done by the user, then the buzzer will beep five
times and LEDs will glow red as indication of false operation. Also if by
mistake user entered wrong entry then one can cancel the operation by pressing
. The key # will terminate every operation running on the NUMLOCK. If user
presses a touch key on the numeric keypad once and does not press any key afterwards then it will wait for next five seconds for key to enter else, it beeps five times and exits the process.
DIA : NUMLOCK ACCESS SYSTEM: FOR DEFAULT PASSWORD
NOTE : Please remember, you need to remember the changed password, which would be used change the password again.
CHANGING NUM LOCK PASSWORD:
As described previously, user can access the elevator car using default user
password that is 1234 terminated by . As a featured user can also change this
default password and can set its own desired password. For the same user have
to follow few steps as below, press followed by the existing default
password that is 1234, if the password is correct then LEDs start blinking red
and blue as indication of process start, here user has to enter new four-digit
user password terminated by *. if the process goes as per given steps, then
the buzzer will beep twice as indication of healthy completion of the process.
Note, user must not enter new user password, as same as the fingerprint
password, it will result in error. If the user starts password changing
process that is LED’s start blinking and do not press any key afterward, then
process will continue for next 10 seconds and terminate with five times beep
as an indication of false operation. If user enter wrong password, then the
LEDs will glow red and buzzer will beep five times.
DIA : NUMLOCK ACCESS SYSTEM: FOR PASSWORD CHANGE
CALIBRATION OF FINGER PRINT ACCESS SYSTEM:
The another but most popular access system is the biometric (finger print)
access system which also gives higher level of security to the user which
needs restricted access to the particular area.
ENROLLMENT OF NEW USER FINGER PRINT :
To enroll new finger print to the BIOMETRIC user just have to follow few steps
below.
Note : One fingerprint Id cannot be used to register other
DIA : ENROLLMENT OF FINGER PRINT OF NEW USER
ERASING THE ENROLLED FINGER PRINT
If user wish to erase enrolled finger print form the finger print module, then user have to follow few steps above.
CHANGING PASSWORD FOR FINGER PRINT ENROLLMENT AND ERASING
DIA: CHANGING PASSWORD FOR FINGERPRINT ENROLLMENT & ERASING
Looking at the security issues one can change the enrollment / erasing
password of the finger print operation. So that only user with authority can
calibrate and erase the finger prints from the finger print module.
COMPATIBILITY OF PRODUCT WITH INDITECH MAKE / OTHER MAKE AND PARALLEL /
SERIAL INTERFACE.
Compatibility of product for INDITECH and for others one potential contact.
© I n d i t e c h E l e c t r o s y s t e m s 2 0 2 2 –
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>