OLYMPIA OP-420091 Spray Head Instruction Manual
- June 12, 2024
- OLYMPIA
Table of Contents
OLYMPIA OP-420091 Spray Head
Product Information
ITEM # | DESCRIPTION |
---|---|
A1 | OP-420091* 1.5 GPM Spray Head (For K-5020) |
A2 | X-4200194* 1.5 GPM Spray Head (For K-5025) |
B | OP-420096 Spray Head Hose |
C | OP-420095 Magnetic Spray Head Support |
D | X-4200190 Spout Repair Kit |
E | OP-390003 Ceramic Disc Cartridge |
F | OP-420057 Retainer Nut |
G | OP-420058* Cap |
H | OP-120004* Lever Handle |
I | OP-420059 Washer |
J | X-4200199 Quick Connect |
K | OP-520015 Locknut with Screws |
L | OP-420094 Rolling Weight |
M | OP-420045* Deck Plate & Base Gasket |
N | OP-520003 Mounting Bolts & Nuts |
1 | OP-420075 Washer |
2 | OP-420061 Allen Screw |
Product Usage Instructions
To use the Olympia product, please follow the instructions below:
- Identify the ITEM # of the specific component you want to use from the table above.
- Refer to the DESCRIPTION column to understand the purpose of the component.
- Assemble the components in the desired configuration according to your needs.
- If you encounter any issues or require further assistance, please contact Olympia Faucets, Inc. at 888-772-7701 during their business hours: Monday-Friday 8 AM to 8 PM EST (5 AM to 5 PM PST).
- For additional care information or troubleshooting inquiries, you can also visit the Olympia Faucets website at www.olympiafaucets.com.
Please note that the usage instructions provided here are general and may vary depending on the specific product configuration. It is always recommended to refer to the user manual provided with your Olympia product for detailed and accurate instructions.
Models
- Model Number: K-5020, K-5025, K-5040, K-5060
Warnings and Notes:
- Check with local plumbing code requirements before installation.
- This product should be installed by a local listed plumber.
- Do not use plumbers’ putty on threads.
Tools
Installation Steps
Single Handle Pull-Down Kitchen Faucet
- Shut off the water supply. Remove old faucet. Clean mounting surface in preparation for new faucet.
- (2a) For 1-Hole Installation:- Ensure there is a washer under the faucet. Place the faucet in position on the sink.
- (2b) With the flat side of the locknut facing down and the steel washer inside the locknut please follow the order as the drawing shows to insert flex hoses through the center hole of the locknut from underneath the sink.
- (2c) Thread locknut onto the faucet shank from underneath the sink. Position the faucet to the desired location from the top and hand-tighten the locknut till it won’t go further. Thread both screws on the locknut and tighten the screws on the locknut with the help of a Phillips head screwdriver to secure the faucet. (Note: Do not overtighten.).
- (3a) For 3-Hole Installation: Thread mounting bolts to the deck plate, apply plumbers putty under the base gasket, place the faucet on the deck plate, and make sure the spout swivel angles are even to the right and to the left. Lead inlet & outlet flex hoses through the center mounting hole to place the faucet with deck plate and base gasket in position on the sink. Hand-tighten the locknut to the faucet and tighten the screws on the locknut with the help of a Phillips head screwdriver from underneath the sink.
- (3b) Thread and tighten both mounting nuts to mounting bolts from underneath the sink to secure the faucet on the sink.
- Slide rolling weight through the spray head hose.
- Insert the spray head hose into the end of the quick connect adapter on the outlet hose, and push until a “click” is heard. Pull down to test engagement.
- Connect hot and cold inlet supply hoses to supply stops. For supply stop with 1 /2″ outlet connection, use 3/8″ male to 1/2″ female adapter for installation. Adapters are optional and are not provided with the faucet. Tum on both side supply stops to check for any leaks.
Parts List
Exploded Drawing (K-5020, K-5025):
Note:
Please specify the finish/color when ordering.
ITEM # | DESCRIPTION | |
---|---|---|
A1 | OP-420091* | 1.5 GPM Spray Head (For K-5020) |
A2 | X-4200194* | 1.5 GPM Spray Head (For K-5025) |
B | OP-420096 | Spray Head Hose |
C | OP-420095 | Magnetic Spray Head Support |
D | X-4200190 | Spout Repair Kit |
E | OP-390003 | Ceramic Disc Cartridge |
F | OP-420057 | Retainer Nut |
G | OP-420058* | Cap |
H | OP-120004* | Lever Handle |
I | OP-420059 | Washer |
J | X-4200199 | Quick Connect |
K | OP-520015 | Locknut with Screws |
L | OP-420094 | Rolling Weight |
M | OP-420045* | Deck Plate & Base Gasket |
N | OP-520003 | Mounting Bolts & Nuts |
1 | OP-420075 | Washer |
2 | OP-420061 | Allen Screw |
Exploded Drawing (K-5040):
Note:
Please specify the finish/color when ordering.
ITEM # | DESCRIPTION | |
---|---|---|
A | OP-420084* | 1.5 GPM Spray Head |
B | OP-420096 | Spray Head Hose |
C | OP-420095 | Magnetic Spray Head Support |
D | X-4200190 | Spout Repair Kit |
E | X-3900008 | Ceramic Disc Cartridge |
F | OP-420085 | Retainer Nut |
G | OP-420043* | Cap |
H | OP-120002* | Lever Handle |
I | OP-420044 | Washer |
J | X-4200199 | Quick Connect |
K | OP-520015 | Locknut with Screws |
L | OP-420094 | Rolling Weight |
M | OP-420045* | Deck Plate & Base Gasket |
N | OP-520003 | Mounting Bolts & Nuts |
1 | OP-420047 | Allen Screw |
2 | OP-420075 | Washer |
Exploded Drawing (K-5060):
Note:
Please specify the finish/color when ordering.
ITEM # | DESCRIPTION | |
---|---|---|
A | OP-420088* | 1.5 GPM Spray Head |
B | OP-420096 | Spray Head Hose |
C | OP-420095 | Magnetic Spray Head Support |
D | X-4200190 | Spout Repair Kit |
E | OP-390003 | Ceramic Disc Cartridge |
F | OP-420057 | Retainer Nut |
G | OP-420058* | Cap |
H | OP-120006* | Lever Handle |
I | OP-420059 | Washer |
J | X-4200199 | Quick Connect |
K | OP-520015 | Locknut with Screws |
L | OP-420094 | Rolling Weight |
M | X-4200173* | Deck Plate & Base Gasket |
N | OP-520003 | Mounting Bolts & Nuts |
1 | OP-420061 | Allen Screw |
2 | OP-420075 | Washer |
For more care information or troubleshooting inquiries about your Olympia
product, Please call:
OLYMPIA FAUCETS, INC. 888-772-7701
Monday-Friday 8 AM to 8 PM EST (5 AM to 5 PM PST)
www.olympiafaucets.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>