YHDC SCT 010 Split Core Current Transformer Instruction Manual

June 12, 2024
YHDC

YHDC SCT 010 Split Core Current Transformer Instruction Manual

S C T 0 1 0

FIG 1.JPG

Characteristic

  • Safety lock buckle, easy to install
  • Built-in over-voltage protection device (TVS tube)
  • Lead type output, length can be customized
  • Suspended type

Product application

  • Portable instrument
  • Household metering
  • Monitor motor load

Product advantage

  • Small volume, Light weight
  • Low cost
  • High turns, High precision

Installation diagram

Primary threading method(Firing line)

FIG 2 Installation diagram.JPG

Typical technical index:

  • Material of core——Ferrite
  • Working voltage——Phase voltage≤ 7 2 0 V
  • Working temperature——-25℃~+60℃
  • Storage temperature——-30℃~+90℃
  • Frequency range— — 5 0 H z ~ 1 K H z
  • Dielectric strength——Input(bare conductor)/output AC 800V/1min 5mA 50Hz
    Output/Outer shell AC 3.5KV/1min 5mA 50Hz

FIG 3.JPG

FIG 4.JPG

*Can be customized parameters/lead length/lead specifications according to user requirements.

Wiring schematic diagram:

FIG 5 Wiring schematic diagram.JPG

Cable(AWG22):
Specifications of lead wire:0.3mm black and white twisted pair
The length of lead wire:50cm
Color of lead wire:white,black

Outline size: (in:mm)

FIG 6 Outline size.JPG