xpr B100PROX-EH-SA Standalone Biometric Reader Installation Guide
- June 12, 2024
- xpr
Table of Contents
B100PROX-EH-SA v2
B100PROX-MF-SA v2
Standalone Biometric Reader
INSTALLER’S MANUAL
INTRODUCTION
B100PROX-SA v2 is access control fingerprint reader designed for easy
management of the users and configuration. The scanner is made with advanced
capacitive sensing technology that provides some advantages over optical
solutions like:
– making almost impossible to make fake copy of the users fingers
– same performance in the different light conditions
– good reading of fingers with stains from daily jobs
Built in strong scanning and matching algorithm provides excellent tolerance
in the way finger is swiped over the sensor reducing to minimum the need to
repeat finger swiping at the sensor.
The reader can store up to 99 finger templates and 2000 cards. One template is
reserved for User manager (Administrator), one template is reserved for Reader
configuration (Installer) and up to 97 templates are for Users.
This manual is used for both B100PROX-EH-SA (EM/HID Cards) and B100PROX-MF-SA
(Mifare Cards).
RECOMMENDATIONS
Consult with installer about safety level of the installation. There are
devices with relays compatible with this reader that can increase the security
of the system if needed. One or two enrolled fingers are enough for one user.
Ask the installer before he leaves the site to enroll your finger as
administrator.
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger.
Some of the users may have very flat fingertips, making difficult for the
sensor to recognize correctly the fingerprint. In most cases, these are
children and older persons. To solve this problem, do the following:
- Try with different user’s fingers to find the “best” finger.
- Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use
soft wet cloth and wipe gently the dirt. Do not use chemicals and materials
that can scratch the sensor.
WARNING!
Do not touch the sensor with other objects than finger. Do not pour or splash
with water or other liquids. When painting or construction work is ongoing in
the area around the reader, protect the reader sensor area from possible
damages and paint.
If reader is to be dismounted or relocated, call authorized installer for the
job. Disposal of this product must be handled according to all national laws
and regulations.
MOUNTING
Do not install the device and cabling close to a source of strong electro-
magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe
it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the
surface will be damaged and the fingerprint can’t be entered.
The operating temperature of the product is between 0ºC – + 50ºC. XPR™ cannot
guarantee the functionality of the product if measures and advice before are
not followed.
SPECIFICATIONS
Fingerprint Capacity: | 97 templates |
---|---|
Prox. cards Capacity: | 2000 cards |
Card Type: | EM or HID compatible (125KHz) – B100PROX-EH-SA |
or Mifare (13,56 Mhz; Classic 1K & 4K, Ultralight, Desfire) – B100PROX-MF-SA
Panel Connection| Cable, 0.5 m
Output:| 1 x Relay (2A/24V AC/DC)
Push Button Input:| Yes
Door Open Time:| Pulse (1 to 30 seconds) or Toggle (ON/OFF)
Entry Mode:| Finger or Card
Programming:| By swiping
Master/Admin Fingers:| 1 Administrator and 1 Installer Finger
Backlight ON/OFF:| Yes
Buzzer ON/OFF:| Yes
Firmware upgrade:| Via RS-485 converter and windows application
Current Consumption:| 150 mA max.
Power Supply:| 9-14 V DC
Indication:| Tricolor Status LED
IP Factor:| IP54 (internal use only)
Operating Temperature :| 0ºC to 50ºC
Operating humidity:| 5% to 95% RH without condensation
Dimensions(mm):| 100 x 94 x 30
APPLICATION DIAGRAM
RECOMMENDED SWIPING TECHNIQUE
Follow the below instructions for correct finger swiping. Starting from the
first finger joint, place the selected finger on the swipe sensor and move it
evenly towards oneself in one steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long
beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep (
3 short beeps)
INDICATION
WIRING
Wiring B100PROX-SA with magnetic lockWiring B100PROX-SA with electric strikeDIPSwitch settings
ADDING ADMIN FINGER
- Push dip switch no.2 in position ON.
- Reset the Power of the device.
- Wait for One long + multiple short beeps
- Put the dip switch in position OFF. (short beeps will stop)
- Wait for about 15 seconds for the LED to blink in Orange.
- Swipe the Master finger min.6 times. (Until Ok Beep)
Warning: This procedure also deletes all the users, the installer’s
finger, installer’s PIN Code and admin’s PIN Code.
Warning: This procedure will unpair the connected relay unit (RTT, DINRTT
or RU2)
PAIRING – BIOMETRIC READER AND REMOTE RELAY UNIT
If secure installation is needed, the reader can be connected to remote relay
unit at secured area, which also can play the role of request-to-exit push
button. Follow the instructions bellow to pair (couple) both devices or refer
to the Remote Relay’s Manual.
Pairing B100PROX-SA v2 with DINRTT
- Close the Jumper. DINRTT beeps continuously and the red led blinks.
- Open the Jumper
- Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
Pairing B100PROX-SA v2 with RTT
- Put Dipswitch No.1 to position ON. RTT beeps continuously and the red led blinks.
- Put Dipswitch No.1 to position OFF.
- Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
Pairing B100PROX-SA v2 with RU2
- Put the Jumper to closed position. RU2 beeps continuously and the red led blinks.
- Put the Jumper to open position.
- Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
Warning: Changing the ADMIN finger will also unpair the remote relay unit.
ADMINISTRATOR PROGRAMMING
Use point fingers as Administrator and Installer. You can use the other
fingers as access fingers.
Administrator finger is enrolled at the end of the system installation.
Initial enrollment of the Admin finger is described in installer manual.
ADD Finger Relay 1 (Finger that will activate on board relay 1)
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 1 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe User Finger min. 6 times (until short + long beep) | ast blinking |
short + long beep
or
Present card/tag 1 time | ast blinking | short + long beep |
---|
ADD Finger Relay 2 (Finger that will activate remote relay 2)
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 2 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe User Finger min. 6 times (until short + long beep) | ast blinking |
short + long beep
or
Present card/tag 1 time | ast blinking | short + long beep |
---|
Relay 2 is available if the reader is used with remote relay unit with 2
relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your
system.
ADD Finger Relay 1 &2 (Finger that will activate relay 1&2)
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 3 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe User Finger min. 6 times (until short + long beep) | ast blinking |
short + long beep
or
Present card/tag 1 time | ast blinking | short + long beep |
---|
Relay 2 is available if the reader is used with remote relay unit with 2
relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your
system.
DELETE Finger
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 4 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe User Finger | ast blinking | short + long beep |
or
Present card/tag 1 time | ast blinking | short + long beep |
---|
DELETE ALL Fingers and Cards
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 4 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | slow blinking | short beep | |
Swipe Admin Finger 2 times | ast blinking | multiple beeps |
CHANGE ADMIN Finger
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 5 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | slow blinking | short beep | |
Swipe Admin Finger 6 times | ast blinking | short + long beep |
CHANGE INSTALLER Finger
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 6 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | slow blinking | short + long beep | |
Swipe Admin Finger 6 times | ast blinking | 3 short beeps |
ADMINISTRATOR PROGRAMMING BLOCK DIAGRAM
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu
INSTALLER PROGRAMMING BY FINGER
Set Relay 1 Time (on board)
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Installer Finger 1 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep |
Swipe the INSTALLER Finger
and start counting seconds| | fast blinking| beeps on 1 second
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode| | fast blinking| short + long beep
Set Relay 2 Time
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Installer Finger 2 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep |
Swipe the INSTALLER Finger
and start counting seconds| | fast blinking| beeps on 1 second
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode| | fast blinking| short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2
relays (DINRTT and RU2). Consult the installer if Relay 2 is available in your
system.
BUZZER ON/OFF
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Installer Finger 3 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe Installer Finger | fast blinking | short + long beep |
BACKLIGHT ON/OFF
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Installer Finger 4 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe Installer Finger | fast blinking | short + long beep |
INSTALLER PROGRAMMING BLOCK DIAGRAM
Swipe the Installer Finger 1 to 4 times depending of the desired menu
This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.
****www.xprgroup.com
Documents / Resources
| xpr
B100PROX-EH-SA Standalone Biometric
Reader
[pdf] Installation Guide
B100PROX-EH-SA, B100PROX-MF-SA, B100PROX-EH-SA Standalone Biometric Reader,
B100PROX-EH-SA, Standalone Biometric Reader, Biometric Reader, Reader
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>