OSRAM PRO 5040 AirZing UV-C Light Purifier
Specification
Product Code | 4062172152655 |
---|---|
Input Voltage | 220~240V, 50/60Hz |
Input Current | 0.19A |
Power Consumption | 40W |
Dimension | L1363mm/W54mm/H78mm |
Installation Height | 2.5M-4M |
Operational Temp. | -10″C ~ 40″C |
Storage Temp. | -20°C ~ 60°C |
Relative Humidity | ,;80% |
UV-C Light Distribution
Light is protecting
AirZing™ UV-C light purifier
- Generates 253.7nm UV light, which is ideal for highly effective sterilization and purification
- Proven technology destroying up to 99.9% of the microorganisms
- Specially designed OSRAM ballasts to optimize performance of OSRAM HNS UV-C lamps
- Equipped with IR sensor to shut system down when people are detected entering the UV workspace
- 30-second-delayed start to enhance operational safety
- Ozone-free emissions
- 360 degrees coverage area
UV-C: A proven technology for sterilization and purification
Globalization and increased travel brings more attention to global public health. Many scientific research institutions and pharmaceutical enterprises are working hard on providing solutions for tackling such challenges. UV-C radiation generated by high-energy UV-C lamps moves at a wavelength range between 200 – 280nm, which is very versatile and can be used for disinfecting water, destroying harmful micro-organisms in other liquids, on surfaces, on food products and in air. With UV-C technology it is possible to destroy more than 99.99% of all pathogens within seconds, without adding chemicals, without harmful side effects and an inexpensive solution that is highly efficient and reliable.
UV-C can destroy most of microorganisms
The cell nucleus of micro-organisms (bacteria and virus) contain thymine, a
chemical
element of the DNA/RNA. This element absorbs UV-C light at a specific
wavelength of 253.7nm and changes to such an extent (formation of thymine
dimers) that the cells are no longer capable of multiplying and surviving.
- UV-C (253.7nm) penetrates the cell wall of the microorganisms
- The high energy photons of the UV-C are absorbed by the cell proteins and DNA/RNA
- UV-C damages the protein structure causing metabolic disruption
- DNA/RNA is chemically altered so organisms can no longer replicate
- Because microorganisms are now unable to metabolize or replicate, the UV-C light has effectively and safely sanitized the UV-C workspace area.
Safety warning
This product emits UV-C light during operation. Always avoid direct or reflected UV-C light exposure to eyes or skins of humans and animals.
- Keep humans and animals out of the operation space when this product is in service.
- This product is intended for indoor air purification purposes only and may not be used for any general lighting application.
- The product is not suitable for cleaning, disinfection or sterilization of medical devices.
For further details please observe the user manual.
Air Zing™ UV-C light purifier
Application guidelines
This linear fixture can be ceiling or wall mounted with an installation height measured from the floor between 2.5 and 4m. Cycle time to run fixture if the workspace is:
PRO 5040
The coverage area of one set of fixture is 15-20m2
– <10m2 , 30 mins is recommended
– 10 – 15m2 , 45 mins is recommend
– 15 – 20m2 , 60 mins is recommended
PRO 5030
The coverage area of one set of fixture is 12-15m2
– <8m2, 30 mins is recommended
– 8 – 12m2 , 45 mins is recommended
– 12 – 15m2 , 60 mins is recommended
If the space is larger than above mentioned area, we suggest to use multiple fixtures, The layout can be adjusted according to interior design.
UV-C technology can be used in …
Air Zing™ PRO
![Air Zing™ m:m]](https://manuals.plus/wp-content/uploads/2023/07/OSRAM-
PRO-5040-AirZing-UV-C-Light-Purifier-Instruction-Manual-12.png)
Product Name
Input Voltage
Input Current
Output Current
Power Consumption
lamp Wattage
Power Factor
THO
UV-C Output (253.7nm)
Initial UV-C lrradiance
UV-C lrradiance@ 9000 h
Lamp Lifetime
Relative Humidity
Dimension
Weight
Operational Temperature
Storage Temperature| AirZing™ PRO 5030
220 V-240 V, 50/60 Hz
0.16 A
360 mA
34W
30W
0.9
<20%
11-12 W
1.2 W/m2 @1m
0.96 W/m2 @1m
9,000 h
::;80%
L1058mm/W54mm/H78mm
1.3 kg (net)/1.9 kg(package)
-10 °C ~ 40 °C
-20 °C ~ 60 °C| AirZing™ PRO 5040
220 V-240 V, 50/60 Hz
0.19 A
430 mA
40W
36W
0.9
<20%
14-15 W
1.4 W/m2 @1m
1.10 W/m2 @1m
9,000 h
::;80%
L1363mm/W54mm/H78mm
1.5 kg (net)/2.2 kg(package)
-10 °C ~ 40 °C
-20 °C ~ 60 °C
---|---|---
More of PURITEC® HNS® UV-C lamps
The core of Air Zing™ are OSRAM PURITEC® HNS® germicidal lamps which are powerful components that may be used in a wide range of applications, such as:
Water purification and cleansing
- Private households
- Water dispensers
- Community water works
- Mobile stations (camping, outdoor activities)
- Swimming pools
- Ultra-pure water systems
- Ponds and aquariums
- Fish farms
- Food processing factories
- Sewage systems
- Designed to perform best
within the fixtures of all major manufacturers
Air purification
- Hospitals
- Doctors’ practices
- Clean rooms
- Offices with or without air-conditioning systems
- Cars
- Storage rooms
- Food processing
- Rooms with frequent public access
- Animal stalls
Surface sterilization
- Hospitals and other aseptic zones
- Health care
- Food and pharmaceutical industry
Find out more information about AirZing™ and our UV-Clamps
OSRAM GmbH
Marcel-Breuer-Strasse 6
80807 Munich, Germany
Phone +49 89-6213-0
Fax +49 89-6213-2020
www.osram.com
Light is protecting
Air Zing TM PRO
The special AirZing™ PRO luminaire is powered by OSRAM germicidal fluorescent lamp (HNS 36W or HNS 30W), which emits shortwave ultraviolet UV-C radiation with a wavelength of 253,7 nm. This radiation is used to disinfect air, water and surfaces and is then fully absorbed by oxygen and ozone in the atmosphere. It effectively destroys bacteria and viruses, including corovirus (COVID-19).
Application in hospitals: Hospital and Office building in Wuhan Pulmonary Hospital
AirZing™ PRO is equipped with a delay starting (switched on after 30 seconds when the serving staff is out of reach radiation range) and the motion sensor. This means that the luminaire switches off safely in case of undesired movement of persons in the irradiated area.
Efficient
|
Precise
|
Premium
|
Powerful
|
Smart
---|---|---|---|---
99,9% Sterilization efficiency
|
253,7 nm UV wave length
|
Ozone Free
|
360° Coverage Area
|
IR Sensor
AREA OF APPLICATIONS
Air purification
Ultraviolet (UV) purification is a very effective method to clean the air of biological pollutants such as bacteria, viruses and fungal spores. UV germicidal lamps can be installed in ventilation ducts to clean the air passing through them. UV air purification is more economical and efficient than other air filtration and cleaning methods.
- Hospitals
- Doctors’ practices
- Clean rooms
- Offices with or without AC systems
- Cars
- Storage rooms
- Food processing
- Rooms with frequent public access
- Animal stalls
Surface cleaning
For packaging pharmaceuticals and food, in aseptic zones in hospitals and for surface cleaning of equipment and instruments objects are exposed directly to UV radiation.
- Hospitals and other aseptic zones
- Health care
- Food and pharmaceutical industry
The cell nucleus of micro-organisms(bacteria and virus) contains thymine, a chemical element of the DNA I RNA. This element absorbs UV-Cat a specific wavelength of 253. 7 nm and changes to such an extent (formation of thymine dimers) that the cell is no longer capable of multiplying and surviving.
-
UV-C (253. 7nm) penetrates the cell wall of the micro-organism
-
The high energy photons of the UV-C are absorbed by the cell proteins and DNA I RNA
-
UV-C damages the protein structure causing metabolic disruption
-
DNA/RNA is chemically altered so organisms can no longer replicate
-
Organisms are unable to metabolize and replicate, CAN’T cause disease or spoilage
How to use AirZing™
AirZingTM can be ceiling mounted or wall mounted, the installation height of general space is between 2.5m-4m. The coverage area of one set of fixture is 15-20m2 (36W)
- <10m2, 30 mins is recommended;
- 10 – 15m2 , 45 mins is recommended;
- 15 – 20m2 , 60 mins is recommended;
-
20m2, multiple fixtures are recommended.
UV-C impacts on Human
Exposure to UV can cause injury to the eyes and skin
Overexposure to UV- C can result in transient conjunctiva! irritation (phot conjunctivitis) and skin irritation (erythema), which disappear within a 24-48 hour period without lasting biological damage (CIE, 2002).
Source: CIE 155:2003 ULTRAVIOLET AIR DISINFECTION 8.1
For example:
- 36W AirZing is installated at 2.5m
- UV-C irradiation is 0.22w/m2
- UV Index is 8.8 = 0.22 x 40 – very high It is therefore necessary to prevent unwanted radiation of persons, animals and plants!
AirZing™ PRO
Product Reference| Product Number|
---|---|---
AirZing™ PRO 5030| 4062172156622| 220-240 50/60 34 0.16 360 > 0,9 < 20 11-12
1.2 9,000 3 1058/54/78 1.3 -10~40 -20~60
AirZing™ PRO 5040| 4062172152655| 20-240 50/60 40 0.19 430 > 0,9 < 20 14-15
1.4 9,000 3 1363/54/78 1.5 -10~40 -20~60
AirZing™ can be used in …
SAFETY WARNING
- This product is intended for indoor air purification and surface purification (non-medical devices) purposes only.
- The product is not suitable for cleaning, disinfection or sterilization of medical devices.
- The product shall not be equipped with general lighting lamps, nor shall the UV-C lamp be installed in general lighting luminaires.
- This product is meant for professional use only. Installation must be carried out by a qualified professional. By purchasing this product, you declare that you are purchasing this for professional use and are/will engage qualified persons to properly install, operate and maintain this product.
- This product shall not be energized during installation, maintenance or replacement of the lamp.
- It is strictly prohibited to use the product in places with inflammable and explosive materials
- This product emits UV-C light during operation. Always avoid direct or reflected UV-C light exposure to humans and animals.
- UV-C radiation produced by this product during operation may cause serious damage to eyes and skin after relatively short exposure times. No humans or animals are allowed to stay nearby. See following table for information about irradiance ES and exposure time texp depending on the distance d:
d [m] | 0.2 | 1 | 2 | 3 |
---|---|---|---|---|
Es [W/m’] | 5.0 | 0.68 | 0.21 | 0.099 |
!exp [s] | 6 | 40 | 140 | 300 |
- Ensure that humans and animals are out of the operation space when this product is in service! Start purification process only if the room has been cleared. Following is an unexhaustive list of recommendations to achieve this goal. More than one option may be chosen.
- Lock the room during operation;
- Warning sing, warning lamp or warning sound may be used;
- Product should be switched on by trained, delegated people only;
- Switch should be outside the room;
- Switch should not be easily confused with normal light switches;
- Switch may be mounted not less than 2m from the ground;
- Switch may be equipped with a locking device which can only be operated byv dedicated operators;
- A door switch may be used that switches off the product if any door is opened;
- Operation of the product can be identified by a slight bluish glow of the lamp.
- Training of personnel not to enter the room respectively leave the room immediately while the product is on. This is a second level measure if other methods like locking the room or entrance warning failed.
- The product is equipped with an IR sensor which switches off the lamp immediately if unexpected human beings are detected inside the UV-working space. Do not rely on the sensor alone. It is only a second level safety measure in case of misuse or violation of the safety precautions above.
- The sensitivity of the sensor decreases at room temperatures above 35°C.
- Do not cover IR sensor or block its view in any conditions.
NOTICES
- This product must be installed properly, please refer to installation instructions to prevent damage to the light source or other components.
- The product needs to be installed at certain height and space within specified temperature. IR sensor might be activated in case of unusual air convections. Insufficient UV-C dose may not achieve the intended purification effect.
- The UV intensity of this product is determined according to the service time. When the accumulative service time of the UV-C lamp exceeds its effective lifetime, please replace the lamp in time.
- UV-C can age non-metallic materials such as plastics, rubbers etc. Shield all non-metallic materials exposed under UV-C light when using the product. Never expose plants to UV-C light.
- When using this product, keep the germicidal space clean and dry, close the doors and windows, and avoid outdoor air circulation. Do not use wind speed regulator.
- This product is ozone free.
- The original design and testing of this product are based on OSRAM HNS T8 36W double-end UV lamp tube. It may perform in different ways if with any other light sources.
- OSRAM HNS tube contains mercury; please follow local regulations when disposing of used light source.
- A 5-second break is required before switching on again right after switching off, due to 3 to 5-second systematic resetting.
- Once the product is switched off by IR sensor, it will not switch on automatically, it needs to be turned on manually. Please refer to the below QR code for product warranty policy. The OSRAM warranty policy would only apply to products that has been installed, used, repaired and maintained properly according to this manual. Failure to observe this requirement shall void any warranty, stated or implied.
REMARK
This product emits UV-C light during operation
The installation and maintenance need to be handled by professional
technicians
RoHS certificate
Avoid direct or reflected UV-C light exposure to eyes or skins of humans and
animals
This product is not suitable for any general lighting application
OSRAM HNS® UV-C lamp contains mercury; follow local regulations when disposing
of used light source
INSTALLATION INSTRUCTIONS
Loose screws to remove the cover plate
Relocate the lamp holders from the casing and fix them into grooves at both ends of the casing
Drill holes at the predefined mounting positions, and embed plastic plugs for M4 screws (prepared by customers)
Mount the cover plate on the casing and fix the cover plate with screws
Connect the power cable in terminals
Plug the grounding socket on the cover plate in the casing
Mount the cover plate on the casing and fix the cover plate with fastening screws
Mount the ultraviolet source into the lamp holder in the direction shown in the figure, rotate 90° and fix it