LINORTEK ‎01-910-00025 Network Break Bell System User Guide

June 12, 2024
LINORTEK

LINORTEK logo

Netbell® -2-1Bel
Network Break Bell System

Applications

Provide remote access to control timed alert system for:

  • Schools
  • Office Buildings
  • Small Factories, Warehouses
  • Any other timed alert system.

The Key Features

  • Network enabled, access the Netbell software from web browser
  • Import/export schedules from existing data in text format
  • Flexible and accurate control of when the bells ring (HH:MM:SS,MM/DD/YYYY, SUNDAY‐ SATURDAY)
  • Built‐in real time clock sync its time from NTP server every 30 minutes (user changeable)
  • Built-in rechargeable battery protected auxiliary real time clock
  • Use as either a network device or a standalone device
  • Designed, developed and built in the USA with global materials

Self-Contained, Easy-To-Use, Remote Access, Scheduling Bells from Web Browser, No Software Required to Install on Your Computer

LINORTEK ‎01-910-00025 Network Break Bell System

 Linortek Net bell® is an ease‐of‐use, network enabled, custom developed device for schools, factories, warehouses and other organizations to build a fully automated web-based timed alert system for signaling shift changes, general alarm, and breaks in areas of high ambient noise levels. The system is built on a TCP/IP platform with a built in web server, which allows users to access, control, and schedule the bells accurately and effectively using an Internet connection from anywhere over the network, with no additional software or designated computer required.

The Netbell-2-1Bel is a one-stop solution that comes with everything needed for installation and operation a bell system. The kit includes one Netbell-2 networked Bell Controller, one 6-in bell kit. The bell kit comes with a 12VDC gray signal bell, one weatherproof back box for wall mounting and one 12VDC power supply to power the bell, one 10ft power cable. With the Netbell-2, you can access, control and schedule bells individually over the network, no additional software or programming required. With the digital inputs you can wire a push switch for ringing bell manually in emergency.
For anyone who has separate areas or multiple buildings where running additional wiring is not an option, but network is available at the locations, you can use the built-in remote feature to manage & schedule multiple Net bell devices from the free Bell Scheduler desktop app, making the management of your bell systems incredibly easy.

Technical Specifications

Netbell-2 Bell Controller with Break Bell
General Information

Model| Netbell-2-1Bel| Netbell-2-2Bel| Netbell-2-1LBel| Netbell-2-2LBel
---|---|---|---|---
Part#| 01-910-00025| 01-910-00027| 01-910-00030| 01-910-00062
Technical Specification
Bell Scheduling Software| Built- In (All software located on built-in web server.)
Event Schedules| Up to 500 Web-Based Event Schedules (Add schedules from web browser)
Bell Ringing Duration| User Programmable for Each Schedule
Built-In Bell/Buzzer| No
Bell Output(s)| 2
External Bell(s)| 1 (6″ Bell/86dBa)| 2 (6″ Bell/86dBa)| 1 (6″ Bell/102 dBa)| 2 (6″ Bell/102 dBa)
Coverage (SQ FT)| 8,000| 16,000| 20,000| 40,000
Manual Bell Control| Yes
Push Switch| Optional
Enclosure| DIN Rail Mountable (For the Netbell-2 Controller)
Accessories| 12VDC Power Adapter/1M RJ45 Cable/ 10ft Power Cable/Wago Connectors
Power Input| 12VDC/POE| 12VDC/POE for Controller, 24VAC for Bell
Voltage Sensor| On Board
Temperature Sensor| On Board
Rechargeable Battery| On Board (For offline time & settings keeping backup up to 7 days)
Working Temperature| From 0 to +60 Celsius
Supported Protocols| HTTP/ SMTP/SNTP

Linor Technology, Inc.
www.linortek.com
Address: Winston Salem, NC 27127