EBECO EB-Therm 205 Thermostat User Guide

June 12, 2024
EBECO

EBECO EB-Therm 205 Thermostat

Product Information

Get started quickly and easily! Here you have a guide to the most important functions and settings, an introduction to theenergy saving programs and an overview of the menu system.

Always read the entire manual for complete product information.

Getting started with EB-Therm

This is what the display looks like when you first start EB-Therm.

  • On/off button
  • Using the menu
    • Start the menu
    • Scroll through the options
    • Exit the menu*
  • Temperature Selected control
  • Arrow keys [ ]
  • Selection button [ ]

Turning off and on

To standby*

Out of standby

*Or wait 30 seconds to exit automatically.

Locking the keypad

  • * Scroll Lock
    • Unlock

1 sec.

1 sec.

*The heat is not being regulated. The clock is running and any settings are saved in the memory.

4 sec.

Basic settings

Time and date

To be able to use all the functions you need to set the time and date first.

Scroll to the correct time*

*Repeat the last two steps to set minutes, day, month and year.
The weekday is set automatically but not displayed.

Desired temperature

Show actual temperature

Lock buttons first Temp. in the floor*

*If the thermostat is set to Floor thermostat. Otherwise the room temperature (R) is displayed.

Energy saving programs

Save energy cleverly and easily! With these programs the heating is adapted to your actual needs and the heat is turned down when it isn’t needed. There are two preset programme options, of which the Home Programme is adjustable:

  • Preset for home environments
  • Program for office environments
  • Start/stop programs
  • Confirm when the correct symbol is flashing*
  • Symbol shows that a program is running
  • *Stop program: Confirm when no symbol is flashing.

Sitemap of the menu

This is how the menu in EB-Therm 205 is structured. Here you can quickly see where all the functions and settings are.

  • PROG
    • Start/stop programs
    • Home programs
    • Office programs
  • SET
    • Various settings
  • CLK
    • Set time and date.
    • Set the temperature to restrict the floor sensor for S R & F.
    • Turn off and on automatic change to DST
  • DISP
    • Set how time will be shown, RNF 24- or 12-hour format.
    • Set how the temperature is to be regulated. F (floor thermostat) – AF Turn off and turn on the adaptive function.
  • SET Adjust preset times and temperatures in the home program.
  • RST Reverts to factory settings and deletes all personal settings.
  • END Exit the menu and return to basic mode.
  • LOCK
    • Locks the keypad
  • END
    • Exits the menu

EBT 205 EN 171019

ebeco.com

Quick guide to EB-Therm 205
Get started quickly and easily! Here you have a guide to the most important functions and settings, an introduction to the energy saving programs and an overview of the menu system.
Always read the entire manual for complete product information.

Getting started

Getting started with EB-Therm

This is what the display looks like when you first start EB-Therm.

Using the menu

*Or wait 30 seconds to exit automatically.

Turning off and on

The heat is not being regulated. The clock is running and any settings are saved in the memory.

Locking the keypad

Basic settings

Time and date

To be able to use all the functions you need to set the time and date first .EBECO-EB-Therm-205-Thermostat-fig 5

Repeat the last two steps to set minutes, day, month and year.
The weekday is set automatically but not displayed.

Desired temperature

Show actual temperature

If the thermostat is set to Floor thermostat.
Otherwise the room temperature (R) is displayed.

More on temperature The EB-Therm 205 can regulate the temperature in three different ways; a floor thermostat, a room thermostat or a room and floor thermostat. This enables the comfort temperature and any flooring temperature requirements to be combined. If the floor sensor is connected when the thermostat is turned on for the first time, the floor thermostat is selected automatically. The room thermostat cannot be selected when the floor sensor is connected. The room and floor thermostat should be used in rooms with wooden flooring and in rooms with large windows that are exposed to solar insolation. Read more about the control functions and how you set them in the manual. Actual temperatures can be read at all times by following the above description.

Energy saving programs

Save energy cleverly and easily! With these programs the heating is adapted to your actual needs and the heat is turned down when it isn’t needed. There are two preset programme options, of which the Home Programme is adjustable:

  • Preset for home environments The temperature is reduced automatically by 5° C (adjustable) during the following times:
    • Monday-Friday, 8.30am-3pm (adjustable)
    • Monday-Sunday, 11pm-5am (adjustable)
  • Program for office environments The temperature is automatically reduced by 5°C at all times except for Monday-Friday, 6am-6pm

Start/stop programsEBECO-EB-Therm-205-Thermostat-fig
8

*Stop program: Confirm when no symbol is flashing.

Sitemap of the menu

This is how the menu in EB-Therm 205 is structured. Here you can quickly see where all the functions and settings are.

PROG
Start/stop programs
Home programs
Office programs

SET

Various settings

  • CLK
    Set time and date.

  • S
    Turn off and on automatic change to DST

  • RNF
    Set how the temperature is to be regulated. F (floor thermostat) – R (room thermostat) – R & F

  • OH
    Set the temperature to restrict the floor sensor for R & F.

  • DISP
    Set how time will be shown, 24- or 12-hour format.

  • AF
    Turn off and turn on the adaptive function.

  • SET
    Adjust preset times and temperatures in the home program.

  • RST
    Reverts to factory settings and deletes all personal set-tings.

  • END
    Exit the menu and return to basic mode.

LOCK
Locks the keypad

END
Exits the menu