OSRAM SubstiTUBE T8 EM LED Tube Installation Guide
- June 12, 2024
- OSRAM
Table of Contents
SubstiTUBE®
T8 EM
SubstiTUBE T8 EM LED Tube
| Conventional
T8 fluorescent tube
on CCG ‘| Maximum case
temperature²
(Tc)| Storage
temperature³
(Ts)| Ambient
temperature4
(Ta)
---|---|---|---|---
LEDTUBE T8 15 EM 438 5.4W 3000K| 0.438m =15W
(a+ b)| 70º C| -20º… 80º C| -20º 45º C
LEDTUBE T8 15 EM 438 5.4W 4000K
LEDTUBE T8 15 EM 438 5.4W 6500K
LEDTUBE T8 18 EM 600 6.6W 3000K| 0.6m = 18W
(a+ b)
LEDTUBE T8 18 EM 600 6.6W 4000K
LEDTUBE T8 18 EM 600 6.6W 6500K
LEDTUBE T8 16 EM 720 7W 3000K| 0.72m =16W
(a+ b)
LEDTUBE T8 16 EM 720 7W 4000K
LEDTUBE T8 16 EM 720 7W 6500K
LEDTUBE T8 30 EM 900 10W 3000K| 0.9m = 30W
(c) – b)
LEDTUBE T8 30 EM 90010W 4000K
LEDTUBE T8 30 EM 900 10W 6500K
LEDTUBE T8 38 EM 1050 11.6W 3000K| 1.05m = 38V.,
(a)
LEDTUBE T8 38 EM 1050 11.6W 4000K
LEDTUBE T8 38 EM 1050 11.6W 6500K
LEDTUBE T8 36 EM 1200 15W 3000K| 1.2 m = 36 W
(a)
1.2 m = 36W LEDTUBE T8 36 EM 1200 15W 4000K
LEDTUBE T8 36 EM 1200 15W 6500K
LEDTUBE T8 58 EM 1500 18.3W 3000K| 1.5m = 58W
(a)
LEDTUBE T8 58 EM 1500 18.3W 4000K
LEDTUBE T8 58 EM 1500 18.3W 6500K
This lamp is designed for general lighting service (excluding for example explosive atmospheres). Since only lamp and starter are replaced there is no constructive modification to the luminaire. This lamp may not be suitable for use in all applications where a traditional fluorescent lamp has been used. The temperature range of this lamp is more restricted. In cases of doubt regarding the suitability of the application the manufacturer of this lamp should be consulted.
- Conventional T8 fluorescent tube on CCG.
- Maximum case temperature.
- Storage temperature.
- Ambient temperature.
- Lamp to be used in dry conditions or in a luminaire that provides protection.
- Lamp suitable for 50 Hz or 60 Hz operation.
- Lamp not suitable for emergency operation.
- Dimming not allowed.
- LED replacement starter.
| | | |
---|---|---|---|---
Lamp to be used in dry conditions or in a luminaire that provides
protection5)| Lamp suitable for 50 Hz or 60 Hz operation6)| Lamp not
suitable for emergency operation7)| Dimming not allowed8)| LED
replacement starter9)
LEDVANCE GmbH
Steinerne Furt 62
86167 Augsburg, Germany
www.ledvance.com LEDVANCE Ltd, Aquila House
Delta Crescent, Westbrook, Warrington
WA5 7NR, United Kingdom
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>