Read before using this equipment

EL5605 Digital Remote

We are constantly improving our products so specifications are subject to change without notice. Visit our website for the latest product information.
Thank you for purchasing the Digital Remote Interface by Wagan Tech® . With normal care and proper treatment, it will provide years of reliable service.
Please read all operating instructions carefully before use.
This Digital Remote Interface is designed to work with the following items:

  • EL7410, EL7411 DC to DC chargers
  • EL3814, EL3816, EL3818 Pure Line Inverters (2nd Gen)

WARNINGS

  • The remote display is designed specifically for use with the above-mentioned devices. Do not attempt to use this remote with any other devices.
  • Do not try to modify the connectors on this device or the accompanying cables. Any attempt to change the wiring to this display could damage either the remote display or the controlling device or both. Any such attempts will void the warranty for both this display and the controlling device.
  • Only use the connection cables provided with the display. Additional or replacement cables can be purchased at www.wagan.com

PRODUCT IMAGES

WAGAN TECH EL5605 Digital Remote Interface - Front

**MOUNTING THE DISPLAY

**

Cut an opening in the mounting surface based on the dimensions shown below:

WAGAN TECH EL5605 Digital Remote Interface - DISPLAY

INSTALLATION

For installation with DC to DC chargers only:

  1. Locate the 4-pin connector attached to the DC to DC Charger.

  2. Remove the plastic dust cover from the 4-pin connector.

  3. Connect the 4-pin connector from the connection cable to the DC to DC charger. Secure this connection by threading the 2 ends of the cable together.WAGAN TECH EL5605 Digital Remote Interface - cable

  4. Connect the red wire attached to the connection cable to any 12V source in the vehicle – this will be used to power the display.
    Note: if the inverter will also be used with the display, connecting this red wire is not necessary.

  5.  Feed the connection cable into the vehicle where you want to mount the display.

  6. Connect the RJ45 end of the cable to either port on the remote display.

WAGAN TECH EL5605 Digital Remote Interface - port

For installation with the inverter only or both DC to DC charger and inverter:

  1. Locate the RJ45 to RJ45 cable included with the remote display.
  2.  Connect the RJ45 cable to the inverter remote port at one end and the remote display at the other end.
  3. Turn the power switch on the inverter to “remote” setting.
  4. The inverter on/off function is controlled by the remote display.
  5. Note: When the inverter is connected to the remote, the remote will receive power from the inverter, so the red wire on the DC to DC charger connection cable does not need to be connected. Tape off this wire to avoid accidental contact with conductive surfaces.
  6. Follow instructions in the previous section “DC to DC chargers only” above to install the DC to DC Charger, skipping step #4.

OPERATING THE REMOTE

  1. Press and hold the “Select” button to turn the display on. The Wagan logo will be displayed during startup.
  2. Press the up and down buttons to switch between views.
  • Inverter status view: Press the “Select” button to turn the inverter on / off.WAGAN TECH EL5605 Digital Remote Interface - off • Inverter settings view: Press the “Select” button to enter setting mode. Note, this will shut the inverter off in order to change the settings. Press the up /down buttons to switch between settings and the “Select” button to change the setting. Once setting is complete, press and hold the “Select” button for 3 seconds. The remote will restart to save the program changes in the inverter.WAGAN TECH EL5605 Digital Remote Interface - settings • DC Charger view: There are no settings or selections controlled in this view.WAGAN TECH EL5605 Digital Remote Interface - CHANGING

CHANGING INVERTER SETTINGS

WAGAN TECH EL5605 Digital Remote Interface - AC
frequency

  • AC frequency – The default setting for the frequency is 60Hz Warning: Before changing this setting, be sure to confirm the frequency requirement of the appliances being connected to the inverter. Wagan will not be responsible for damage to appliances that are not compatible with the inverter setting.

  • Power Save – Turning on the Power Save function will enable the inverter to enter a standby mode when no load is applied.

  • Battery type – adjusts operational and alarm settings based on battery type.
    – Lead acid: 10.5V (alarm), 10V (shutoff)
    – Lithium: 11.5V (alarm), 11V (shutoff)

  • Low Voltage Alarm setting – Allows you to manually set the desired low voltage alarm setting according to your system requirements. This will change the low voltage shutoff settings accordingly (0.5 V below Alarm value).

NOTE: changing the Low Voltage Alarm setting will override the default Low Voltage settings based on Battery Type.

CARE AND MAINTENANCE

  • Keep away from water and condensation.
  • Do not attempt to disassemble the remote.

WAGAN Corp. Limited Warranty

The WAGAN Corporation warranty is limited to products sold only in the United States.
Warranty Duration:
Product is warranted to the original purchaser for a period of one (1) year from the original purchase date, to be free of defects in material and workmanship. WAGAN Corporation disclaims any liability for consequential damages. In no event will WAGAN Corporation be responsible for any amount of damages beyond the amount paid for the product at retail.
Warranty Performance:
During the warranty period, a product with a defect will be replaced with a comparable model when the product is returned to WAGAN Corporation with an original store receipt. WAGAN Corporation will, at its discretion, replace or repair the defective part. The replacement product will be warranted for the balance of the original warranty period. This warranty does not extend to any units which have been used in violation of written instructions furnished.
Warranty Disclaimers:
This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products. There shall be no claims for defects or failure of performance or product failure under any theory of tort, contract or commercial law including, but not limited to negligence, gross negligence, strict liability, breach of warranty, and breach of contract.
Returns:
WAGAN Corporation is not responsible for any item(s) returned without an official Return Authorization number (RA#). Please contact our customer service team by phone or email to obtain an RA#. You can also visit our website and chat with our team during our normal business hours. For more details and instructions on how to process a warranty claim, please read the “Returns” section under the “Contact” page on our website. WAGAN Corporation is not responsible for any shipping charges incurred ineturning the item(s) back to the company for repair or replacement.
©2023

31088 San Clemente Street
Hayward, CA 94544, U.S.A.
Tel: +1.510.471.9221
U.S. & Canada Toll Free: +1.800.231.5806
customerservice@wagan.com
www.wagan.com
©2023 Wagan Corporation. All Rights Reserved.
Wagan Tech and wagan.com are trademarks
of Wagan Corporation.

REV20230613

Documents / Resources

| WAGAN TECH EL5605 Digital Remote Interface [pdf] User Manual
EL5605, EL5605 Digital Remote Interface, Digital Remote Interface, Remote Interface, Interface
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals