FOS technologies IQ Par IP65 HEX Party Light User Manual
- June 12, 2024
- FOS technologies
Table of Contents
FOS technologies IQ Par IP65 HEX Party Light
Safety instructions
Thank you for choosing our FOS IQ Par lp65. for your own safety, please read this user manual carefully
BEFORE YOU INITIAL START· UP!
CAUTION!
Be careful with your operations. With a high voltage, you can suffer a
dangerous electric shock when touching the wires!
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
CAUTION!
- Keep this device away from rain and moisture!
- Unplug the mains lead before opening the housing!
Important:
- The manufacturer will no_ accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
- Please consider that damages caused by manual modifications to the device are not subject to warranty.
- During the operation the housing becomes hot). Allow the fixture to cool for approximately 20 minutes prior to manipulating it.
- Make sure that the available voltage is not higher than stated on the rear panel.
WARNING!
This unit does not contain an ON/OFF switch. Always disconnect the power input
cable to completely remove power from the unit when not in use or before
cleaning or servicing the fixture.
- Make sure that the power cord is never crimped or damaged by sharp edges. Check the device and the power cord from time to time.
- Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
- This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to the earth.
- The electric connection, repairs, and servicing must be carried out by a qualified employee.
- Do not connect this device to a dimmer pack.
- Do not switch the fixture on and off in short intervals as this would reduce the lamp’s life.
- During the initial start-up, some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective.
- Do not touch the device’s housing with bare hands during its operation (the housing becomes hot)!
- For replacement use lamps and fuses of the same type and rating only.
CAUTION! EYE DAMAGES!
Avoid looking directly into the light source (meant especially for
epileptics)!
UNPACKING
Please carefully unpack it when you receive the fixture and check whether it is damaged during the transportation. And please check whether the following items are included inside the box:
The FOS IQ Par lp65 is made of a new type of high-temperature strength of engineering plastics and cast aluminum casing with a nice outlook. The fixture is designed and manufactured strictly following CE standards, complying with the international standard DMX512 protocol. It’s available independently controlled and linkable with each other for operation. And it is applicable for large-scale live performances, theater, studios, nightclubs, and discos. This manual covers important information on installation and applications. Meanwhile, please keep this manual well for future needs.
TECHNICAL INFORMATION
Features
- 19*12W 6-in-1 LEDs (RGBWAUV)
- 50, 000 hours lifespan and low power consumption
- High light output with even color mixing
- 26-degree beam angle
- 0-100% Smooth LED dimmer
- Flicker-free control system for TV production and film
- High-efficiency LED shutter with variable speed
- Strobe effect with 1-25T /s and pulse effect
- Built-in default programs
- Macro effects
- 30/12 DMX channels USITT MDX-512
- 4-Button LED display control menu DMX512, master-slave and sound activated controllable or auto
- Noise-free efficient aluminum cooling system
- I P65 protection rating
- IP-rated power connector IN/OUT
- IP-rated 3-pin DMX connectors IN/OUT
- -35 ·c~45 ·cambient temperature
- Dual mounting brackets for installation/floor stand
- WDMX operations
- 3 pixels rings
Specifications
- Input Voltage: AC90-260V 50/60Hz
- LEDQuantities: 19PCS 6IN1-12WLED
- Control Signal: DMX512,master-slave and sound activated or auto operation
- Control Channel: 22/10 DMX Channels USITT DMX-512
- Power Consumption: 266W
- Dimensions: 155(D)299(W)2 79(H)mm
- Packing Dimensions: 370(D)335(W)245(H)mm
- Net Weight: 4.65kg
- Gross Weight: 5.65kg
PHOTOMETRIC DATA
Photometric Beam Angle Data
OPERATION INSTRUCTIONS
- The FOS IQ Par lp65 is for beam effect for on-site decoration purposes.
- Don’t turn on the fixture if it’s been through severe temperature differences like after transportation because it might damage the light due to the environmental changes. So make sure to operate the fixture until it is in normal temperature.
- This light should be kept away from strong shaking during any transportation or movement.
- Don’t pull up the light by only the head, or it might cause damage to the mechanical parts.
- Don’t expose the fixture in overheat, moisture, or an environment with too much dust when installing it. And don’t lay any power cables on the floor. Or it might cause electronic shock to the people.
- Make sure the installation place is in good safe condition before installing the fixture.
- Make sure to put the safety chain and check whether the screws are screwed properly when installing the fixture.
- Make sure the lens are in good condition. It’s recommended to replace the units if there are any damages or severe scratches. Make sure the fixture is operated by qualified personnel who know the fixture before using it.
- Keep the original packages if any second shipment is needed. Don’t try to change the fixtures without any instruction from the manufacturer or the appointed
INSTALLATIONS
Cautions:
- For added protection mount the fixtures in areas outside walking paths, seating areas, or in areas were the fixture might be reached by unauthorized personnel.
- Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
- Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
- Never stand directly below the device when mounting, removing, or servicing the fixture. from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture is kept at least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).
Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails.
Mounting points:
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, a fine knowledge of the installation material
being used, and periodic safety inspection of all installation material and
the fixture. If you lack these qualifications, do not attempt the installation
yourself. Improper installation can result in bodily injury. Be sure to
complete all rigging and installation procedures before connecting the main
power cord to the appropriate wall outlet.
Clamp Mounting:
FOS IQ Par lp65 provides a unique mounting bracket assembly that integrates
the bottom of the base, and the safety cable rigging point in one unit (see
the illustration below). When mounting this fixture to the truss be sure to
secure an appropriately rated clamp to the included omega bracket using a M 1
O screw fitted through the center hole of the “Hanging Kit”. As an added
safety measure be sure to attach at least one properly rated safety cable to
the fixture using one of the safety cable rigging point integrated in the base
assembly.
CONTROL CONNECTION
- Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the moving head. You can chain multiple Moving head together through serial linking. The cable needed should be two core, screened cable with XLR input and output connectors. Please refer to the diagram below. DMX-512 connection with DMX terminator.
- For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a3 resistor connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the chain. Please see illustrations below.
MENU OPERATIONS
DMX PROTOCOL
Mode/Channel | Value | Function |
---|---|---|
CH30 | CH12 | |
1 | 1 | |
0..255 | Dimmer 0%…100% |
2
| ****
2
| | Shutter
0..31| Shutter closed
32..63| shutter open
64..95| Strobe effect slow to fast
96..127| shutter open
128..159| Pulse-effect in sequences slow to fast
160..191| shutter open
192..223| Random strobe effect slow to fast
224..255| shutter open
3| 3| | Red
0..255| 0-100% Red dimmer from dark to bright
4| 4| | Green
0..255| 0-100% Green dimmer from dark to bright
5| 5| | Blue
0..255| 0-100% Blue dimmer from dark to bright
6| 6| | White
0..255| 0-100% White dimmer from dark to bright
7| 7| | Amber
0..255| 0-100% Amber dimmer from dark to bright
8| 8| | UV
0..255| 0-100% UV dimmer from dark to bright
9| | | Red1
0..255| 0-100% Red1 dimmer from dark to bright
10| | Green1
0..255| 0-100% Green1 dimmer from dark to bright
11| | Blue1
0..255| 0-100% Blue1 dimmer from dark to bright
12| | White1
0..255| 0-100% White1 dimmer from dark to bright
13| | Amber1
0..255| 0-100% Amber1 dimmer from dark to bright
14| | | UV1
---|---|---|---
0..255| 0-100% UV1 dimmer from dark to bright
15| | Red2
0..255| 0-100% Red2 dimmer from dark to bright
16| | Green2
0..255| 0-100% Green2 dimmer from dark to bright
17| | Blue2
0..255| 0-100% Blue2 dimmer from dark to bright
18| | White2
0..255| 0-100% White2 dimmer from dark to bright
19| | Amber2
0..255| 0-100% Amber2 dimmer from dark to bright
20| | UV2
0..255| 0-100% UV2 dimmer from dark to bright
21| | Red3
0..255| 0-100% Red3 dimmer from dark to bright
22| | Green3
0..255| 0-100% Green3 dimmer from dark to bright
23| | Blue3
0..255| 0-100% Blue3 dimmer from dark to bright
24| | White3
0..255| 0-100% White3 dimmer from dark to bright
25| | Amber3
0..255| 0-100% Amber3 dimmer from dark to bright
26| | UV3
0..255| 0-100% UV3 dimmer from dark to bright
27
|
9
| | Macro Color
0..15| No Function
16..31| Red
32..47| Green
48..63| Blue
64..79| White
80..95| Red+Green
96..111| Red+Blue
112..127| Red+White
128..143| Green+Blue
144..159| Green+Whi te
160..175| Blue+Wtihe
176..191| R+G+B
27
|
9
| 192..207| R+G+B+W
---|---|---|---
208..212| 2700K
213..217| 3200K
218..222| 3500K
223..227| 5000K
228..232| 5500K
233..237| 6000K
238..242| 6500K
243..247| 7000K
248..255| 8000K
28
|
10
| | Color Temp
0..15| No Function
16..45| Below3200K
46..75| 3200K – 3500K
76..105| 3500K – 5000K
106..135| 5000K – 5500K
136..165| 5500K – 6000K
166..195| 6000K – 6500K
196..225| 6500K – 7000K
226..255| 7000K – 8000K
29
|
11
| | Macro RUN
0..15| No function
16..31| Macro Run 1
32..47| Macro Run 2
48 ..63| Macro Run 3
64..79| Macro Run 4
80..95| Macro Run 5
96..111| Macro Run 6
112..127| Macro Run 7
128..143| Macro Run 8
144..159| Macro Sound 1
160..175| Macro Sound 2
176..191| Macro Sound 3
192..207| Macro Sound 4
208..223| Macro Sound 5
224..239| Macro Sound 6
240..255| Macro Sound 7
30| 12| | Macro Speed
0..255| Macro Speed from Slow To Fast
Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt, and smoke-fluid residues must not build upon or within the fixture. Otherwise, the fixture’s light output will be significantly reduced. Regular cleaning will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life. A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should alcohol or solvents be used!
DANGER!
Disconnect from the mains before starting any maintenance work
The front objective lens will require weekly cleaning as smoke-fluid tends to
build up residues, reducing the light output very quickly. The cooling fans
should be cleaned monthly.
The interior of the fixture should be cleaned at least annually using a vacuum
cleaner or an air jet. Dichroic colour filters. Remove dust and dirt from the
fans and cooling vents using a soft brush and vacuum cleaner.
Important! Check the air filters periodically and clean them before they
become clogged!
Clean two air filters placed in the fixture’s covers and two in the fixture
base. Use a vacuum cleaner or compressed air or you can wash them and put them
back dry.
After replacing the air filters, reset the elapsed time counter in the menu
“Information” (information —>Air Filters—>Elapsed Time).
Replacing the fuse. Before replacing the fuse, unplug the main lead.
- Remove the fuse holder on the rear panel of the base with a fitting screwdriver from the housing (anti-clockwise).
- Remove the old fuse from the fuse holder.
- Install the new fuse in the fuse holder (only the same type and rating).
- Replace the fuse holder in the housing and fix it.
Wireless function
- Choose the wireless DMX on the light display “SET”—>”Signal setting”—>”Wireless DMX”(ULd showed on display)
- Wireless transmitter transmits a signal, press the “UP” and “ENTER” buttons at the same time on the light display until you see the indicator flashing yellow
- The pairing signal in the transmitter would see an indicator flashing green on the light display
In the Use mode, Description of Status Indicator:
Protocol | Action | Status Description |
---|
W-DMXReceive
Protocol
|
White
|
Connection is not Established
| Red| Deleting Connection
| Red(Fast-Flash)| Connection is Lost
| Green(Fast-Flash)| Connecting to Transmitter
| Green{Slow-Flash)| Connected, Without OMX Signal
| Green| Connected, Receiving OMX Signal
Read User Manual Online (PDF format)