SJE RHOMBUS Installer Friendly Series Single Phase Simplex Instruction Manual

June 12, 2024
SJE RHOMBUS

SJE-RHOMBUS-LOGO

SJE RHOMBUS Installer Friendly Series Single Phase Simplex

SJE-RHOMBUS-Installer-Friendly-Series-Single-Phase-Simplex-
PRO

Product Information

The Three Phase Duplex is a pump control and system monitoring system that can be operated in either Demand Dose or Timed Dose mode. It is equipped with a Float or C-LevelTM Sensor for pump control and continuous level monitoring. The panel features a touch pad with various features for easy operation and monitoring.

The IFS duplex control panel utilizes an innovative circuit board design to control two alternating 208/240/480 VAC three phase pumps in water and sewage applications. IFS panels feature an easy-to-use touch pad on inner door for programming and system monitoring. The alternating action equalizes pump wear. In addition, this system provides override control should either pump fail. The panel configuration can be easily converted in the field to either a timed dose or demand dose. Available with the EZconnex® float system. The panel can utilize the C-Level™ sensor for continuous level monitoring. It senses the level in the tank and sends a signal to the panel. Pump activation levels can be adjusted by using the panel touch pad. C-Level™ CL40 sensor operating range is 3-39.9 inches (7.6 101.3 cm). C-Level™ CL100 operating range is 3-99.5 inches (7.6-252.7 cm).

TOUCHPAD FEATURES

SJE-RHOMBUS-Installer-Friendly-Series-Single-Phase-
Simplex-3

  • A. Level Status indicators illuminate when floats or set points are activated; alarm will activate if a float operates out of sequence
  • B. HOA (Hand-Off-Automatic) buttons control pump mode with indication; Hand mode defaults to Automatic when stop level or redundant off level is reached
  • C. Pump Run indicators will illuminate when pumps are called to run
  • D. Lead/Lag selector toggles pump operation (alternate 1-2 and 2-1)
  • E. LED display shows system information including: level in inches or centimeters (C-Level™ only), mode, pumps elapsed time (hh:mm), events (cycles), alarm counter, float error count, timed dose override counter (timed dose only), and ON/OFF times (timed dose only)
  • F. NEXT push button toggles display
  • G. UP and SET push buttons set pump ON/OFF times (timed dose only) and activation levels (C-Level™ only)

COMPONENTS

SJE-RHOMBUS-Installer-Friendly-Series-Single-Phase-
Simplex-4

  1. Enclosure base measures 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm); NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use)
  2. Red LED beacon provides 360° visual check of alarm condition
  3. Exterior Alarm Test/Normal/Silence switch allows horn and light to be tested and horn to be silenced in an alarm condition; alarm automatically resets once alarm condition is cleared
  4. Motor protective switches provide adjustable overload, branch circuit protection and pump disconnect
  5. IEC motor contactors control pumps by switching electrical lines
  6. Multi-tap transformer (208/240/480 VAC primary) provides 120 VAC control alarm voltage or 600 VAC primary transformer
  7. Float connection terminal block
  8. Control Power indicator/fuse indicator light illuminates if control power is present in panel; alarm will activate if control fuse is blown
  9. Alarm Power indicator/fuse indicator light illuminates if alarm power is present in panel
  10. Large incoming power connection terminal block
  11. Terminal block float wiring label
  12. Ground lugs
  13. Alarm horn provides audio warning of alarm conditions (83 to 85 decibel rating) (Not shown)

Note: Options, voltage, and amp range selected may change enclosure size and component layout.
Note: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel.

Control and System Monitoring

SJE-RHOMBUS-Installer-Friendly-Series-Single-Phase-
Simplex-2

CONTROL PANEL| | IFS|
---|---|---|---
MODEL TYPE| | 6| Three Phase Duplex (includes Option 8AC as standard)
ALARM PACKAGE| | 1| Alarm Package (includes test/normal/silence switch, fuse, red light, & horn)
ENCLOSURE RATING| | W| Weatherproof, NEMA 4X (engineered thermoplastic)
| 208/240/480V| 600V
PUMP FULL-LOAD AMPS| | 001| 1.0 – 1.6 FLA| | 005| 1.0 – 1.6 FLA
| 101| 1.6 – 2.5 FLA| | 105| 1.6 – 2.5 FLA
| 201| 2.5 – 4.0 FLA| | 205| 2.5 – 4.0 FLA
| 301| 4.0 – 6.3 FLA| | 305| 4.0 – 6.3 FLA
| 401| 6.0 – 10.0 FLA| | 405| 6.0 – 10.0 FLA
| 511| 9.0 – 14.0 FLA| | 515| 9.0 – 14.0 FLA
| 611| 13.0 – 18.0 FLA| | 615| 13.0 – 18.0 FLA
| 621| 17.0 – 23.0 FLA| | 625| 17.0 – 23.0 FLA
| 701| 20.0 – 25.0 FLA| | 705| 20.0 – 25.0 FLA
FLOAT SWITCH APPLICATION| | H| Floats – Pump Down (select Option 17 below)
| E| EZconnex® Float Switch System (select Option 34 or 35 below)
| X| No Floats
| C| C-Level™ Sensor (select Option 24 or 29) Select Option 3E and/or 4A & 4D for high water alarm and/or redundant off floats

NOTE: Pump down applications only. Industry practices suggest that a secondary device, such as a float switch, be used for redundant activation of the high-level alarm and pump shut off when using the C-Level™ sensor.

ENCLOSURE UPSIZE: If you selected one or more of the options, add a one- time charge for enclosure upsize.

PRICING WORKSHEET

  • IFS Three-Phase Duplex Base Price
  • Alarm Package
  • Enclosure Rating
  • Pump Full Load Amps
  • Float Switch Application
  • Total Options
  • Enclosure Upsize
  • TOTAL LIST PRICE

DESCRIPTION

| OPTIONS| DESCRIPTION| | OPTIONS| DESCRIPTION
---|---|---|---|---|---
| 3A| Alarm Flasher| | 17C| Sensor Float® / Internally Weighted (per Float) – Mercury
| 3B| Manual Alarm Reset| | 17D| Sensor Float® / Externally Weighted (per Float) – Mercury
| 3E| High Water Alarm Float (must also select Option 17) Only Available with Float Switch Application = C| | 17G| SJE MilliAmpMaster™ / Pipe Clamp (per Float) – Mechanical
| 17H| SJE MilliAmpMaster™ / Externally Weighted (per Float) – Mechanical
| 4A| Redundant Off (must also select Option 4D if floats are required)| | 17J| Sensor Float® / Pipe Clamp (per Float) – Mercury
| 4D| Redundant Off Float (must also select Option 4A and Option 17)| | 19F| Fourth Float to Separate Alarm Function from Lag
| 5A | Thermal Cutout/Heat Sensor Auto Reset (for pumps with thermal switch leads)| | 24E| C-Level™ CL40 Sensor with 4’ Vent Tube and 20’ Cord
| 24F| C-Level™ CL40 Sensor with 4’ Vent Tube and 40’ Cord
| 5E | Seal Failure Circuit and Red Indicator (2 Wire)| | 24G| C-Level™ CL40 Sensor with 8’ Vent Tube and 20’ Cord
| 6A| Auxiliary Alarm Contact, Form C| | 24H| C-Level™ CL40 Sensor with 8’ Vent Tube and 40’ Cord
| 8AC| Display Board – Includes: ETM Counter, Events (Cycles) Counter, Alarm Counter and Lead/Lag Selector (included as standard)| | 24X| No C-Level™ CL40 Sensor
| 29A| C-Level™ CL100 Sensor with 10’ Vent Tube and 20’ Cord
| 10E| Lockable Latch – NEMA 4X| | 29B| C-Level™ CL100 Sensor with 10’ Vent Tube and 40’ Cord
| 10G| Lightning Arrestor| | 29X| No C-Level™ CL100 Sensor
| 10K| Anti-condensation Heater| | 34D | EZconnex® 4-Port, 25’, with 10’ Floats (3) / Pipe Clamp, Sealing Plug
| 11C| Additional NEMA 1 Remote Alarm Panel (must also select Option 6A)| | 34E | EZconnex® 4-Port, 50’, with 10’ Floats (3) / Pipe Clamp, Sealing Plug
| 11D| Additional NEMA 4X Remote Alarm Panel (must also select Option 6A)| | 34G | EZconnex® 4-Port, 25’, with 20’ Floats (3) / Pipe Clamp, Sealing Plug
| 16A| 10’ Cord in Lieu of 20’ Cord (per Float)| | 34H | EZconnex® 4-Port, 50’, with 20’ Floats (3) / Pipe Clamp, Sealing Plug
| 16B| 15’ Cord in Lieu of 20’ Cord (per Float)| | 35D | EZconnex® 4-Port, 25’, with 10’ Floats (4) / Pipe Clamp
| 16C| 30’ Cord in Lieu of 20’ Cord (per Float)| | 35E | EZconnex® 4-Port, 50’, with 10’ Floats (4) / Pipe Clamp
| 16D| 40’ Cord in Lieu of 20’ Cord (per Float)| | 35G | EZconnex® 4-Port, 25’, with 20’ Floats (4) / Pipe Clamp
| | 35H | EZconnex® 4-Port, 50’, with 20’ Floats (4) / Pipe Clamp

EZconnex® mechanically-activated, narrow angle float switches with quick release connections

www.sjerhombus.com
email: customer.service@sjeinc.com

© 2020 SJE, Inc. All Rights Reserved. SJE Rhombus is a trademark of SJE, Inc.

www.sjerhombus.com
Toll Free 888-342-5753

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SJE RHOMBUS User Manuals

Related Manuals