SJE RHOMBUS CL40 Installer Friendly Series Site Single Phase Simplex Owner’s Manual

June 12, 2024
SJE RHOMBUS

SJE-RHOMBUS-LOGO

SJE RHOMBUS CL40 Installer Friendly Series Site Single Phase Simplex

SJE-RHOMBUS-CL40-Installer-Friendly-Series-Site-Single-Phase-Simplex-
PRO

Product Information

The Single Phase Duplex is a pump control system that can be used for demand dose or timed dose applications. It is equipped with a Float or C-LevelTM sensor for pump control, system monitoring, event logging, and reporting. The panel features the C-LevelTM sensor, which allows for continuous level monitoring in the tank. The sensor detects the level and sends a signal to the panel. Pump activation levels can be adjusted using the panel touch pad. The operating range for the C-LevelTM CL40 sensor is 3-39.9 inches (7.6-101.3 cm), while the CL100 sensor has an operating range of 3-99.5 inches (7.6-252.7 cm).

The IFS In-Site® duplex control panel utilizes an innovative circuit board design to control two alternating 120/208/240V single phase pumps in water and sewage applications. IFS panels feature an easy-to-use touch pad on inner door for programming and system monitoring. The alternating action equalizes pump wear. In addition, this system provides override control should either pump fail. Quick retrieval of all system events can be done by downloading panel information onto a USB flash drive. The panel configuration can be easily converted in the field to either a timed dose or demand dose. Available with the EZconnex® float system.

Monitor system events including pump run times, pump cycles, alarm conditions, power outages, service calls and more! Quick, convenient reports make diagnosing system conditions easy! Plug the flash drive into the USB port located on the inner door of the IFS In-Site® panel to download system events which occurred. No computer is needed at the site! Use the flash drive (included with panel) with any computer to download system information and reports. The pre-loaded software on the flash drive formulates system data for you, creating reports quickly in an easy-to-read format so system conditions can be easily identified and corrected. In addition to monitoring system events, the IFS In-Site® panel logs any service calls and changes made to system settings, which helps protect service providers.

The panel can utilize the C-Level™ sensor for continuous level monitoring. It senses the level in the tank and sends a signal to the panel. Pump activation levels can be adjusted by using the panel touch pad. C-Level™ CL40 sensor operating range is 3-39.9 inches (7.6-101.3 cm). C-Level™ CL100 operating range is 3-99.5 inches (7.6-252.7 cm).

Product Usage Instructions

  1. Install the Single Phase Duplex panel in a suitable location near the pump and tank.
  2. Connect the C-LevelTM sensor to the tank to enable continuous level monitoring. Adjust the pump activation levels using the panel touch pad.
  3. If using timed dose mode, use the UP and SET Push Buttons on the touch pad to set the desired pump ON/OFF times.
  4. Ensure that the control power and alarm power are present in the panel by checking the corresponding indicator lights.
  5. If an alarm condition occurs, use the Exterior Alarm Test/Normal/Silence switch to test the horn and light. The horn can be silenced by switching to the Silence position.
  6. If necessary, reset the alarm once the alarm condition is cleared.
  7. To download time-stamped system events, insert a flash drive into the USB port.
  8. Use the Manual Report switch to date and time stamp service calls.
  9. Refer to the schematic/wiring diagram and pump specification label inside the panel for additional information and guidance.

TOUCH PAD FEATURES

SJE-RHOMBUS-CL40-Installer-Friendly-Series-Site-Single-Phase-Simplex-
\(1\)

  • A. Level Status indicators illuminate when floats or set points are activated; alarm will activate if a float operates out of sequence
  • B. HOA (Hand-Off-Automatic) buttons with indication control pump mode; Hand mode defaults to Automatic when stop level or redundant off level is reached
  • C. Pump Run indicators will illuminate when pumps are called to run
  • D. LED display for system information including: level in inches or centimeters (C-Level™ only), mode, pumps elapsed time (hh:mm), events (cycles), alarm counter, float error count, timed dose override counter (timed dose only), pump ON/OFF times (timed dose only), and sequence ON/OFF times (timed dose only)
  • E. NEXT push button toggles display
  • F. UP and SET Push Buttons used to set pump ON/OFF times (timed dose only), pump operation (alternate 1-2 and 2-1), date and hour, activation levels (C-Level™ only)

COMPONENTS

SJE-RHOMBUS-CL40-Installer-Friendly-Series-Site-Single-Phase-Simplex-
\(2\)

  1. Enclosure base measures 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm); NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use)
  2. Red LED beacon provides 360° visual check of alarm condition
  3. Exterior Alarm Test/Normal/Silence switch allows horn and light to be tested and horn to be silenced in an alarm condition; alarm automatically resets once alarm condition is cleared
  4. Alarm horn provides audio warning of alarm condition (83 to 85 decibel rating)
  5. Circuit breakers (optional) provide pump disconnect and branch circuit protection
  6. Power relays control pump by switching electrical lines; definite purpose contactors used when pump full load amps are above 15
  7. Float connection terminal block
  8. Incoming Control/Alarm Terminal Block
  9. Control Power indicator/fuse indicator light illuminates if control power is present in panel; alarm activates if control fuse is blown
  10. Alarm Power indicator/fuse indicator light illuminates if alarm power is present in panel (Not shown)
  11. Ground lugs
  12. Incoming pump power connections
  13. RF filter
  14. Power supply
  15. Control fuse
  16. Alarm fuse
  17. USB port for flash drive to download time-stamped system events
  18. Manual report switch date and time stamps service calls

Note: Options, voltage, and amp range selected may change enclosure size and component layout.
Note: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel.

Control and System Monitoring

SJE-RHOMBUS-CL40-Installer-Friendly-Series-Site-Single-Phase-Simplex-
\(3\)

CONTROL PANEL| | IFI|
---|---|---|---
MODEL TYPE|  | 3| Duplex Timed Dose (includes Option 8AC as standard)
 | 4| Duplex Demand Dose (includes Option 8AC as standard)
__**ALARM PACKAGE| | 1| Alarm Package (includes test/normal/silence switch, fuse, red light, & horn)
ENCLOSURE RATING| | W| Weatherproof, NEMA 4X (engineered thermoplastic)
STARTING DEVICE|  | 1| 120/208/240V
 | 9| 120V only
PUMP FULL LOAD AMPS|  | 0| 0 – 7 FLA
 | 1| 7 – 15 FLA
 | 2| 15 – 20 FLA
PUMP DISCONNECTS|  | 0| No Pump Disconnect
 | 4| Circuit Breaker(s) 120V (select STARTING DEVICE Option 9 above)
Circuit Breaker(s) 120/208/240V (select STARTING DEVICE Option 1 above)
FLOAT SWITCH APPLICATION**|  | H| Floats – Pump Down (select Option 17 below)

Timed dose = timer enable and alarm / Demand dose = stop, start, and alarm

 | E| EZconnex® Float Switch System

(select Option 34 or 35 below)

| Timed Dose
Demand Dose
 | X| No Floats| Timed Dose
Demand Dose
 | C| C-Level™ Sensor (select Option 24 or 29) Select Option 3E and/ or 4A & 4D for high water alarm and/or redundant off floats| Timed Dose
Demand Dose

NOTE: Pump down applications only. Industry practices suggest that a secondary device, such as a float switch, be used for redundant activation of the high level alarm and pump shut off when using the C-Level™ sensor.

PRICING WORKSHEET

  • IFI Duplex Base Price: ___
  • Alarm Package: ___
  • Enclosure Rating: ___
  • Starting Device: ___
  • Pump Full Load Amps: ___
  • Pump Disconnects: ___
  • Float Switch Application: ___
  • Total Options: ___
  • TOTAL LIST PRICE: ___

DESCRIPTION

  OPTIONS DESCRIPTION   OPTIONS DESCRIPTION
  1J Duo Alarm Inputs   17C Sensor Float® / Internally Weighted (per

Float) – Mercury
 | 3A| Alarm Flasher|  | 17D| Sensor Float® / Externally Weighted (per Float) – Mercury
 | 3B| Manual Alarm Reset|  | 17G| SJE MilliAmpMaster™ / Pipe Clamp (per Float) – Mechanical
 | 3E| High Water Alarm Float (must also select Option 17)

Only Available with Float Switch Application = C

|  | 17H| SJE MilliAmpMaster™ / Externally Weighted (per Float) – Mechanical
 | 17J| Sensor Float® / Pipe Clamp (per Float) – Mercury
 | 4A| Redundant Off

(must also select Option 4D if floats are required)

| Timed Dose|  | 18A| Timer Override Float (Timed Dose Float Panel Only)
Demand Dose|  | 19F| Fourth Float to Separate Alarm Function from Lag

(Demand Dose Float Panel Only)

 | 4D| Redundant Off Float (must also select Option 4A and Option 17)
 | 6A| Auxiliary Alarm Contact, Form C|  | 24E| C-Level™ CL40 Sensor with 4’ Vent Tube and 20’ Cord
| 8AC| Display Board – Includes: ETM Counter, Events (Cycles) Counter, Alarm Counter, Override Counter (Timed Dose Only), and Lead/ Lag Selector (Demand Dose Only) (included as standard)|  | 24F| C-Level™ CL40 Sensor with 4’ Vent Tube and 40’ Cord
 | 24G| C-Level™ CL40 Sensor with 8’ Vent Tube and 20’ Cord
 | 24H| C-Level™ CL40 Sensor with 8’ Vent Tube and 40’ Cord
 | 10E| Lockable Latch – NEMA 4X|  | 24X| No C-Level™ CL40 Sensor
 | 10F| Lightning Arrestor (select pump circuit breakers, control and alarm power combined)|  | 29A| C-Level™ CL100 Sensor with 10’ Vent Tube and 20’ Cord
 | 29B| C-Level™ CL100 Sensor with 10’ Vent Tube and 40’ Cord
 | 10K| Anti-condensation Heater (must select if operating temperature is colder than 0 degrees F or -18 degrees C)|  | 29X| No C-Level™ CL100 Sensor
 | 34D | EZconnex® 4-Port, 25’, with 10’ Floats (3) / Pipe Clamp, Sealing Plug
 | 11C| Additional NEMA 1 Remote Alarm Panel (must also select Option 6A)|  | 34E | EZconnex® 4-Port, 50’, with 10’ Floats (3) / Pipe Clamp, Sealing Plug
 | 11D| Additional NEMA 4X Remote Alarm Panel (must also select Option 6A)|  | 34G | EZconnex® 4-Port, 25’, with 20’ Floats (3) / Pipe Clamp, Sealing Plug
 | 15A| Control/Alarm Circuit Breaker|  | 34H | EZconnex® 4-Port, 50’, with 20’ Floats (3) / Pipe Clamp, Sealing Plug
 | 16A| 10’ Cord in Lieu of 20’ Cord (per Float)|  | 35D | EZconnex® 4-Port, 25’, with 10’ Floats (4) / Pipe Clamp
 | 16B| 15’ Cord in Lieu of 20’ Cord (per Float)|  | 35E | EZconnex® 4-Port, 50’, with 10’ Floats (4) / Pipe Clamp
 | 16C| 30’ Cord in Lieu of 20’ Cord (per Float)|  | 35G | EZconnex® 4-Port, 25’, with 20’ Floats (4) / Pipe Clamp
 | 16D| 40’ Cord in Lieu of 20’ Cord (per Float)|  | 35H | EZconnex® 4-Port, 50’, with 20’ Floats (4) / Pipe Clamp

EZconnex® mechanically-activated, narrow angle float switches with quick release connections

9500060J Rev 01/23
© 2020 SJE, Inc. All Rights Reserved.
SJE Rhombus is a trademark of SJE, Inc.

www.sjerhombus.com
Toll Free 888-342-5753
www.sjerhombus.com
E-mail: [email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SJE RHOMBUS User Manuals

Related Manuals