BLUE SQUARE VLT600150 Vivid Pool and Spa Transformers Installation Guide

June 12, 2024
BLUE SQUARE

BLUE SQUARE VLT600150 Vivid Pool and Spa Transformers

Product Information

The Pool and Spa Transformers VLT600150 and VLT600300 are electrical transformers specifically designed for use in pool and spa lighting systems. These transformers are manufactured by Blue Square Manufacturing and are used to convert the primary input voltage of 120VAC to a lower output voltage of either 150W or 300W.
The transformers come with a package that includes:

  • (1) Transformer
  • (2) Screws
  • (2) Anchors

The dimensions of the transformer are:

  • Width: 10.75 inches
  • Depth: 8.78 inches
  • Height: 11.5 inches

Product Usage Instructions

Determine The Load

Prior to installing the transformer, it is important to determine the load requirements. The circuit loads should not exceed 80% of the transformer’s capacity. To calculate the total wattage, add up the wattage of all the light fixtures. The total wattage should be 20% less than the transformer’s wattage capacity. If the total wattage exceeds the capacity, a secondary or larger transformer may be required.

Determine Wire Gauge

To determine the appropriate wire gauge for your lighting job, refer to the provided tables in the user manual. The tables provide information on the recommended wire gauge based on the distance between the transformer and the light fixtures.

For VLT600150 (150W Output):

Distance (Feet) Wire Gauge Voltage (VAC)
5 2#6AWG 13VAC
10 2#8AWG 13VAC
20 2#10AWG 13VAC
30 2#12AWG 13VAC
40 2#14AWG 15VAC

For VLT600300 (300W Output):

Distance (Feet) Wire Gauge Voltage (VAC)
5 2#6AWG 13VAC
10 2#8AWG 13VAC
20 2#10AWG 13VAC
30 2#12AWG 13VAC
40 2#14AWG 13VAC
50 2#14AWG 13VAC

Mount Transformer

Choose a suitable location for mounting the transformer. Use the top and bottom keyholes on the transformer as a guide for marking the desired location. Drill holes on the marks and insert wall anchors. Thread the screw into the top keyhole and hang the transformer on it. Place a screw through the bottom keyhole and secure both screws using a screwdriver.

Remove Front Cover

To access the internals of the transformer, loosen the two screws on the side to remove the front cover.

Remove Inside Cover

Remove the inside cover from the holder to expose the wiring and terminals of the transformer.

Install Conduit Adapter

  • Install the conduit adapter and flexible cord connector to provide a secure connection for the electrical wiring.
  • For more detailed installation and maintenance instructions, please refer to the complete user manual available at www.bluesquaremfg.com.

INSTALLATION & MAINTENANCE

Important Safety Instructions: Read Before Installation

Installation, Operating and Safety Instructions
Instructions for installation and use of this product are provided by the manufacturer.

  1. Proper installation, wiring, servicing method.
  2. Installation instructions shall include a swimming pool junction box that shall be installed between the power unit and the luminaire if the power unit intended for connection to conduit which extends directly to the forming shell of a wet-nicheluminaire or the mounting bracket of a no-niche luminaire or an underwater pool light.

Determine The Load
The general capacity should have been determined prior to purchasing the transformer. Circuit loads should not exceed 80% of capacity. As a general rule, total light fixture wattage should not exceed 80% of transformer capacity. To determine the total wattage, simply add up the wattage of all fixture lamps. This number should be 20% less than the transformer’s wattage capacity. If you are over capacity, your installation may require a secondary or larger transformer.

Determine Wire Gauge
The following tables are to help you determine what size cable is needed for your lighting job.

120VAC Primary Input – 150W Output

Distance Feet 2#6AWG 2#8AWG 2#10AWG 2#12AWG 2#14AWG
  • 5 ft.
  • 30 ft.
  • 60 ft.
  • 90 ft.
  • 120 ft.
  • 150 ft.
  • 180 ft.
  • 210 ft.
  • 240 ft.

|

  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 15 VAC
  • 15 VAC
  • 15 VAC
  • 15 VAC
  • 15 VAC

|

  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 15 VAC
  • 15 VAC

|

  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC

|

  • 13 VAC
  • 13 VAC
  • 13 VAC

|

  • 13 VAC
  • 13 VAC

Length of run to light from transformer.

120VAC Primary Input – 300W Output

Distance Feet 2#6AWG 2#8AWG 2#10AWG 2#12AWG
  • 5 ft.
  • 10 ft.
  • 20 ft.
  • 30 ft.
  • 40 ft.
  • 50 ft.
  • 60 ft.
  • 70 ft.
  • 80 ft.
  • 90 ft.
  • 100 ft.
  • 110 ft.

|

  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 15 VAC
  • 15 VAC
  • 15 VAC

|

  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 15 VAC
  • 15 VAC
  • 15 VAC

|

  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 15 VAC
  • 15 VAC

|

  • 13 VAC
  • 13 VAC
  • 13 VAC
  • 15 VAC

Length of run to light from transformer.

Package Contents

  1. (1) Transformer
  2. (2) Screw
  3. (2) Anchor

Product Dimensions

BLUE-SQUARE-VLT600150-Vivid-Pool-and-Spa-
Transformers-01

  1. Mount Transformer

  2. Determine the desired location for mounting the transformer. Mark on the desired location using the top and bottom keyhole as a guide. Drill holes on the marks and insert the wall anchors.

  3. Thread the screw into the top keyhole. Leave enough of the screw out to hang the transformer on. Hang the top keyhole onto the screw. Then place a screw through the bottom keyhole. Secure both the bottom and top screw using a screwdriver.


  4. Remove Front Cover
    Loosen the two screws on the side to remove the front cover from the transformer.


  5. Remove Inside Cover
    Remove the inside cover from the holder.


  6. Install Conduit Adapter
    Install the conduit adapter and flexible cord connector to the transformer.
    BLUE-SQUARE-VLT600150-Vivid-Pool-and-Spa-
Transformers-05

  7. Wiring Main Supply Wires

  8. Pass the main supply cables through the conduit and insert them into the supply wire compartment of the transformer. Then fit the conduit to the conduit adapters. Using UL listed wire connectors (sold separately), connect the black main supply wire to the black wire from the transformer, connect the white main supply wire to the white wire from the transformer and connect the green main supply wire to the green wire (ground) from the transformer.

  9. Apply duct seal to main supply wire exits on conduit adapters properly to seal them against moisture.
    BLUE-SQUARE-VLT600150-Vivid-Pool-and-Spa-
Transformers-06

  10. Wiring Fixture Supply Wires

  11. Pass fixture supply cables (from pool or spa light) through another conduit and insert them into the transformer. Then fit the conduit to the conduit adapters. Strip both ends of the supply wires.

  12. Open the lever and insert one end of the wire into the COM block and the other end into the 13V or 15V block. Close the levers to lock the inserted wires into place.

  13. Apply duct seal to the fixture supply wire exits on conduit adapters properly to seal them against moisture.
    BLUE-SQUARE-VLT600150-Vivid-Pool-and-Spa-
Transformers-07

  14. Install Inside Cover
    Place the inside cover back onto the holder.


  15. Install Cover
    Place the front cover back onto the transformer and secure with previously removed screws.

Help Hotline
[email protected]
480.612.6880
Mon-Fri 7am-3pm (Arizona Time)
Specifications and product details subject to change without notice.
© Copyright 2022, Blue Square®
All rights reserved.
[email protected]
480.612.6880

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BLUE SQUARE User Manuals

Related Manuals