FRICO 800W 230V Built-in Thermocassette HPZ Instruction Manual
- June 12, 2024
- FRICO
Table of Contents
Original instructions
Thermocassette HPZ
800W 230V Built-in Thermocassette HPZ
Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not
apply to all application areas.
The Regulation applies when an installation is intended to provide thermal
comfort for people in the premises. The Regulation does not apply to heating
installations of a more technical nature e.g. in engineering/utility rooms, in
production processes, frost protection, etc. The Regulation also does not
apply to installations in vehicles, offshore or outdoors. Many of Frico’s
products can be used as both local space heaters (as defined in (EU)
2015/1188) and for technical heating purposes. It is up to the installer
responsible for the installation to assess whether the Ecodesign Regulation is
applicable or not. Control solutions for installations not covered by the
Ecodesign Regulation are listed in a separate table.
Dimensions
| L [mm]| W [mm]| H [mm]| A [mm]
---|---|---|---|---
HPZ8| 593| 320| 87| 234
HPZ12| 593| 460| 87| 334
Installation
Controls
Item number | Type | HxWxD [mm] |
---|---|---|
92790 | TAP16R | 87x87x53 |
205540 | TEP44 | 87x87x55 |
93044 | RTX54 | 82x88x25 |
205550 | SKG30 | 115x85x40 |
Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188
Item number | Type | HxWxD [mm] |
---|---|---|
5999 | KRT1900 | 165x57x60 |
10214 | KRTV19 | 165x57x60 |
Technical specifications
Item number| HPZ8| Heat output [W]| Voltage [V]| Amperage [A]| Max. surface
temperature [°C]| Dimensions LxWxH [mm]| Weight [kg]
---|---|---|---|---|---|---|---
146859| Type| 800| 230V~| 3,5| 320| 593x320x87| 5,6
74756| HPZ12| 600| 230V~| 5,3| 320| 593x460x87| 9,4
**** Protection class : IP44
Heat output
Max. surface temperature
Voltage
Weight
Amperage
Wiring diagrams
Internal wiring diagrams
Control by thermostat Control by thermostat and black bulb sensor
Control with thermostat – for
installations not covered by the Ecodesign Regulation (EU) 2015/1188
Main office
Frico AB
Industrivägen 41
SE-433 61 Sävedalen
Sweden
Tel: +46 31 336 86 00
mailbox@frico.se
www.frico.net
For latest updated information and information
about your local contact: www.frico.net
Art.nr 157230, 2022-1 1-09 ZD
References
Read User Manual Online (PDF format)