KLiMAiRE KIWU Series Split Type Room Air Conditioner Instructions

June 12, 2024
KLiMAiRE

KLiMAiRE Logo Mark of Superior Quality
KIWU/KOIU SERIES

SPLIT-TYPE ROOM AIR CONDITIONER
Service Manual

IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
For more information please visit www.klimaire.com

MAINTENANCE

Warning| ⋅When cleaning, you must shut down the machine and cut off the power supply for more than 5 minutes.
⋅Under no circumstances should the air condioner be flushed with water.
⋅ Vola (e.g. thinner or gasoline) will damage the air condi, so only use so dry cloth or wet cloth dipped with neutral detergent to clean the air condiace.
⋅Pay ao cleaning the filter screen regularly to avoid dust covering which will affect the air filtraag environment is dusty, the cleaning frequency should be done more frequently.
⋅ Aer removing the filter screen, do not touch the fins of the indoor unit to avoid cuts.⋅
---|---
Clean the unit| KLiMAiRE KIWU Series Split Type Room Air -
IconWiping damp Gentle wipe the unit surface
Tip: Wipe frequently to keep air condi and good appearance .
Clean the filter| KLiMAiRE KIWU Series Split Type Room Air -
filter Tip: When you find accumulated dust in the filter, please clean the filter on o ensure the clean, healthy and efficient opera inside the air condi.
Service and maintenance| ⋅When the air condior a long ollowing work: Take out the batteries of the remote controller and disconnect the power supply of the air condioner.
⋅When star to use aer long-term shutdown:
1. Clean the unit and filter screen;
2. Check whether there are obstacles at the air inlet and outlet of indoor and outdoor units;
3. Check whether the drain pipe is unobstructed; Install the baeries of the remote controller and check whether the power is on.

TROUBLESHOOTING

MALFUNCTION POSSIBLE CAUSES
The air conditioning unit does not operate Power failure/plug pulled out.

Damaged indoor/outdoor unit fan motor.
Faulty compressor thermomagnetic circuit breaker.
Faulty protective device or fuses.
Loose connections or plug pulled out.
It sometimes stops operating to protect the appliance.
Voltage higher or lower than the voltage range.
Active TIMER-ON function.
Damaged electronic control board.
Strange odor| Dirty air filter.
Noise of running water| Back flow of liquid in the refrigerant circulation.
A fine mist comes from the air outlet| This occurs when the air in the room becomes very cold, for example in the “COOLING” or “DEHUMIDIFYING/DRY” modes.
A strange noise can be heard| This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.
Insufficient airflow, either hot or cold| Unsuitable temperature setting.
Obstructed air conditioner intakes and outlets.
Dirty air filter.
Fan speed set at minimum.
Other sources of heat in the room.
No refrigerant.
The appliance does not respond to commands| Remote control is not close enough to indoor unit.
The batteries of remote control need to be replaced.
Obstacles between remote control and signal receiver in indoor unit.
The display is off| Active DISPLAY function.
Power failure.
Switch off the air conditioner immediately and cut off the power supply in the event of:| Strange noises during operation.
Faulty electronic control board.
Faulty fuses or switches.
Spraying water or objects inside the appliance.
Overheated cables or plugs.
Very strong smells coming from the appliance.

ERROR CODE ON THE DISPLAY
In case of error, the display on the indoor unit shown the following error codes:

Display Description of the trouble
Indoor room temperature sensor fault
Indoor pipe temperature sensor fault
Outdoor pipe temperature sensor fault
Refrigerant system leakage or fault
Malfunction of indoor fan motor
Outdoor ambient temperature sensor fault
Indoor and outdoor communication fault
Outdoor discharge temperature sensor fault
Outdoor IPM module fault
Outdoor current detect fault
Outdoor PCB EEPROM fault
Outdoor fan motor fault
Outdoor suction temperature sensor fault

KLiMAiRE LogoMark of Superior Quality
2190 NW 89 Place, Doral, FL 33172 – USA
Tel: (305) 593 – 8358
www.klimaire.com
customerservice@klimaire.com
The Klimaire logo is a registered Trademark of Klimaire Products Inc.
Copyright 2023 Klimaire Products Inc.
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for details.
M0WIU2302

Documents / Resources

| KLiMAiRE KIWU Series Split Type Room Air Conditioner [pdf] Instructions
KIWU, KOIU, KIWU Series Split Type Room Air Conditioner, Split Type Room Air Conditioner, Room Air Conditioner, Air Conditioner
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

KLiMAiRE User Manuals

Related Manuals