Klimaire KIWU-KOIU Series Split-Type Room Air Conditioner User Manual

June 12, 2024
KLiMAiRE

Klimaire KIWU-KOIU Series Split-Type Room Air Conditioner

KIWU/KOIU User’s Manual

Mark of Superior Quality

IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

For more information please visit www.klimaire.com

MOUS-2302

CONTENTS

  • The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.
  • The shape and position of buttons and indicators may vary according to the model, but their function are the same.

SAFETY PRECAUTIONS

SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER

  1. Read this guide before installing and using the appliance.

  2. Carry out a test cycle after installing the air conditioner and record the operating data.

  3. The packaging materials are recyclable and should be disposed of in the separate waste bins. Take the air conditioner at the end of its useful life to a special waste collection center for disposal.

  4. Only use the air conditioner as instructed in this booklet.
    These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance.

  5. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  6. Cleaning and maintenance must be carried out by specialized technical personnel. In any case disconnect the appliance from the mains electricity supply before carrying out any cleaning or maintenance.

  7. This appliance has been made for air conditioning domestic environments and must not be used for any other purpose, such as for drying clothes, cooling food, etc.

  8. Always use the appliance with the air filter mounted. The use of the conditioner without air filter could cause an excessive accumulation of dust or waste on the inner parts of the device with possible subsequent failures.

  9. The batteries in the remote controller must be recycled or disposed of properly. For disposal of scrap batteries, please discard the batteries as sorted municipal waste at the accessible collection point.

  10. Never remain directly exposed to the flow of cold air for a long time. The direct and prolonged exposition to cold air could be dangerous for your health. Particular care should be taken in the rooms where there are children, old or sick people.

  11. If the appliance gives off smoke or there is a smell of burning, immediately cut off the power supply and contact the Service Center.

  12. The prolonged use of the device in such conditions could cause fire or electrocution.

  13. Have repairs carried out only by an authorised and certified AC technician.

  14. Ensure that the appliance is disconnected from the power supply when it will remain unused for a long time.

Product Usage Instructions

Before using the air conditioning unit, read the user manual carefully and follow all safety precautions. If you have any questions or concerns, consult with the sales agency or manufacturer.

After installing the air conditioner, carry out a test cycle and record the operating data.

Always use the air conditioner as instructed in the user manual.
Do not use it for any other purpose than air conditioning domestic environments.

Ensure that the appliance is always used with the air filter mounted to prevent an excessive accumulation of dust or waste on the inner parts of the device with possible subsequent failures.

Do not allow children to play with the appliance. Cleaning anduser maintenance should not be made by children without supervision.

Cleaning and maintenance must be carried out by specialized technical personnel. Always disconnect the appliance from the mains electricity supply before carrying out any cleaning or maintenance.

Never remain directly exposed to the flow of cold air for a long time as it could be dangerous for your health. Particular care should be taken in the rooms where there are children, old or sick people.

If the appliance gives off smoke or there is a smell of burning, immediately cut off the power supply and contact the Service Center. The prolonged use of the device in such conditions could cause fire or electrocution.

Have repairs carried out only by an authorized and certified AC technician.

Ensure that the appliance is disconnected from the power supply when it will remain unused for a long time.

IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
For more information please visit www.klimaire.com

The design and specifications are subject to change without prior notice for product improvement.
Consult with the sales agency or manufacturer for details.

  • The shape and position of buttons and indicators may vary according to the model, but their function are the same.

SAFETY PRECAUTIONS

SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER

  1. Read this guide before installing and using the appliance.

  2. Carry out a test cycle after installing the air conditioner and record the operating data.

  3. The packaging materials are recyclable and should be disposed of in the separate waste bins.
    Take the air conditioner at the end of its useful life to a special waste collection center for disposal.

  4. Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance.

  5. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have beengiven supervision or instructions concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  6. Cleaning and maintenance must be carried out by specialized technical personnel. In any case disconnect the appliance from the mains electricity supply before carrying out any cleaning or maintenance.

  7. This appliance has been made for air conditioning domestic environments and must not be used for any other purpose, such as for drying clothes, cooling food, etc.

  8. Always use the appliance with the air filter mounted. The use of the conditioner without air filter could cause an excessive accumulation of dust or waste on the inner parts of the device with possible subsequent failures.

  9. The batteries in the remote controller must be recycled or disposed of properly. For disposal of scrap batteries, please discard the batteries as sorted municipal waste at the accessible collection point.

  10. Never remain directly exposed to the flow of cold air for a long time. The direct and prolonged exposition to cold air could be dangerous for your health. Particular care should be taken in the rooms where there are children, old or sick people.

  11. If the appliance gives off smoke or there is a smell of burning, immediately cut off the power supply and contact the Service Center.

  12. The prolonged use of the device in such conditions could cause fire or electrocution.

  13. Have repairs carried out only by an authorised and certified AC technician.

  14. Ensure that the appliance is disconnected from the power supply when it will remain inoperative for a long period and before carrying out any cleaning or maintenance.

  15. Selecting the most suitable temperature can prevent damage to the appliance.

SAFETY RULES AND PROHIBITIONS

  1. Do not touch the appliance when barefoot or parts of the body are wet or damp.
  2. Do not obstruct the air inlet or outlet of the indoor or the outdoor unit. The obstruction of these openings causes a reduction in the operative efficiency of the conditioner with possible consequent failures or damages.
  3. In no way alter the characteristics of the appliance.
  4. Do not climb onto or place any heavy or hot objects on top of the appliance.
  5. Do not leave windows or doors open for long when the air conditioner is operating.
  6. Do not direct the airflow onto plants or animals.
  7. A long direct exposition to the flow of cold air of the conditioner could have negative effects on plants and animals.
  8. Do not climb onto or place any objects on the outdoor unit.
  9. Never insert a stick or similar object into the appliance. It could cause injury.

REMOTE CONTROL NAME OF PARTS

Indoor Unit Display

Klimaire-KIWU-KOIU-Series-Split-Type-Room-Air-
Conditioner-1

No LED Function
1 Indicator for Timer, temperature and Error codes.
2 Lights up during Timer operation.
3 **** SLEEP mode

The shape and position of switches and indicators may be different according to the model,but their function is the same.

REMOTE CONTROL

Remote control DISPLAY

Klimaire-KIWU-KOIU-Series-Split-Type-Room-Air-
Conditioner-5 Klimaire-KIWU-KOIU-
Series-Split-Type-Room-Air-Conditioner-6

The display and some functions of the remote control may vary according to the model.

Klimaire-KIWU-KOIU-Series-Split-Type-Room-Air-
Conditioner-7

The display and some functions of the remote control may vary according to the model.
The shape and position of buttons and indicators may vary according to the model, but their function is the same.
The unit confirms the correct reception of each button with the beep.

Replacement of Batteries
Remove the battery cover plate from the rear of the remote control, by sliding it in direction as the arrow.
Install the batteries according the direction (+ and -)shown on the Remote Control.
Reinstall the battery cover by sliding it into place.

Use 2 pieces LRO3 AAA (1.5V) batteries.
Do not use rechargeable batteries.
Replace the old batteries with new ones of the same type when the display is no longer legible.
Do not dispose batteries as unsorted municipal waste.
Collection of such waste separately for special treatment is necessary.

For some models of the remote controller, you can program the temperature display between oC and oF.

  1. Long press the MODE button, until the ( ) icon flash, to set the Cooling only type.
  2. Long press the MODE button, until the ( ) icon flash, to set the Heating pump type.
    Note: If you set the remote control in cooling mode, it will not be possible to activate the heating function in units with a heating pump. If you need to reset, take out the batteries and install again.

For some models of the remote controller, you can program the temperature display between oC and oF.

  1. Press and hold the TURBO button over 5 seconds to get into the change mode;
  2. Press and hold the TURBO button, until it switch to oC and oF;
  3. Then release the pressing and wait for 5 seconds, the function will be selected.

Note:

  1. Direct the remote control toward the Air conditioner.
  2. Check that there are no objects between the remote control and the Signal receptor in the indoor unit.
  3. Never leave the remote control exposed to the rays of the sun.
  4. Keep the remote control at a distance of at least 1m from the television or other electrical appliances.

COOLING MODE

The cooling function allows the air conditioner to cool the room and reduce Air humidity at the same time.

To activate the cooling function (COOL), press the MODE button until the symbol appears on the display.
With the button or set a temperature lower than that of the room.

FAN MODE (Not FAN button)

Fan mode, air ventilation only.

To set the FAN mode, press MODE until appears on the display.

DRY MODE

This function reduces the humidity of the air to make the room more comfortable.
To set the DRY mode, Press MODE until appears in the display. An automatic function of pre-setting is activated.

AUTO MODE

Automatic mode.

To set the AUTO mode, press MODE untilappears on the display.
In AUTO mode the run mode will be set automatically according to the room temperature.

HEATING MODE

The heating function allows the air conditioner to heat the room.

To activate the heating function (HEAT), press the MODE button until the symbol appears on the display.
With the button or set a temperature higher than that of the room.

In HEATING operation, the appliance can automatically activate a defrost cycle, which is essential to clean the frost on the condenser so as to recover its heat exchange function.
This procedure usually lasts for 2-10 minutes.
During defrosting, indoor unit fan stop operation. After defrosting, it resumes to HEATING mode automatically.

(For North American market)
If necessary, you can press ECO button 10 times within 8 seconds under heating mode to start the forced defrosting. It will defrost the outdoor ice much faster.

FAN SPEED function (FAN button)

Change the operating fan speed.

Press FAN button to set the running fan speed,it can be set to AUTO/ MUTE/ LOW/ LOW-MID/ MID/ MID-HIGH/ HIGH/ TURBO speed circularly.

Klimaire-KIWU-KOIU-Series-Split-Type-Room-Air-
Conditioner-25

Child-Lock function

  1. Long press MODE and TIMER button together to active this function, and do it again to deactivate this function.
  2. Under this function, no single button will active.

TIMER function —- TIMER ON

To automatic switch on the appliance.

When the unit is switch-off, you can set the TIMER ON.

To set the time of automatic switch-on as below:

  1. Press TIMER button first time to set the switch-on, and will appear on the remote display and flashes.
  2. Press or to button to set desired Timer-on time. Each time you press the button, the time increases/decreases by half an hour between 0 and 10 hours and by one between 10 and 24 hours.
  3. Press TIMER button second time to confirm.
  4. After Timer-on setting, set the needed mode (Cool/ Heat/ Auto/ Fan/ Dry), by press the MODE button. And set the needed fan speed, by press FAN button. And press or to set the needed operation temperature.
    CANCEL it by press TIMER button.

TIMER function —- TIMER OFF

To automatic switch off the appliance.

When the unit is switch-on, you can set the TIMER OFF.

To set the time of automatic switch-off, as below:

  1. Confirm the appliance is ON.

  2. Press the TIMER button at first time to set the switch-off.
    Press or to set the needed timer.

  3. Press TIMER button at the second time to confirm.

CANCEL it by press TIMER button.

Note: All programming should be operated within 5 seconds, otherwise the setting will be cancelled.

SWING function

  1. Press the button SWING to activate the louver,

  2. Press to activate the horizontal flaps to swing from up to down, the will appear on the remote display.
    Press again to stop the swing movement at the current angle.

  3. Press to active the vertical deflectors to swing from left to right, the will appear on the remote display.
    Press again to stop the swing movement at the current angle.

  4. If the vertical deflectors are positioned manually which placed under the flaps, they allow to move the air flow direct to rightward or leftward.

  5. For some inverter heating models, press horizontal SWING and vertical SWING together button at the same time, it will activate the Self-Clean function.

This adjustment must be done while the appliance is switched off.

Never position Flaps manually, the delicate mechanism might seriously damaged!

Never put fingers, sticks or other objects into the air inlet or outlet vents. Such accidental contact with live parts might cause unforeseeable damage or injury.

TURBO function

To activate turbo function, press the TURBO button, and will appear on the display. Press again to cancel this function.
In COOL/ HEAT mode, when you select TURBO feature, the appliance will turn to quick COOL or quick HEAT mode, and operate the highest fan speed to blow strong airflow.

MUTE function

  1. Press MUTE button to active this function, and will appears on the remote display.
    Do it again to deactivate this function.

  2. When the MUTE function runs, the remote controller will display the auto fan speed, and the indoor unit will operate at lowest fan speed to be quiet feeling.

  3. When press FAN/ TURBO / SLEEP button, the MUTE function will be cancel. MUTE function can not be activated under dry mode.

SLEEP function

Pre-setting automatic operating program.
Press SLEEP button to activate the SLEEP function, and appears on the display. Press again to cancel this function.
After 10 hours running in sleep mode, the air conditioner will change to the previous setting mode.

I FEEL function (Optional)

Press I FEEL button to active the function, the  will appear on the remote display. Do it again to deactivate this function.
This function enables the remote control to measure the temperature at its current location, and send this signal to the air conditioner to optimize the temperature around you and ensure the comfort.
It will automatically deactivate 2 hours later.

ECO function

In this mode the appliance automatically sets the operation to save energy.

Press the ECO button, the appears on the display, and the appliance will run in ECO mode. Press again to cancel it.

Note: The ECO function is available in both COOLING and HEATING modes.

DISPLAY function (Indoor display)

Switch ON/OFF the LED display on panel.
Press DISPLAY button to switch off the LED display on the panel. Press again to switch on the LED display.

GEN function (Optional)

  1. Turn on the indoor unit at first, and long press MUTE button 3 seconds to active, and do it again to deactivate this function.
  2. Under this function, short press MUTE to select the General type L3 – L2 – L1 – OF.
  3. Select OF and wait 2 seconds to exit it.
    If the indoor unit displays “0A”, please use the remote to raise the operating gear of the GEN mode, and the compressor will restart after stopping for 3 minutes.
SELF-CLEAN function

Only optional for some heating pump inverter appliance.
To active this function, turn off the indoor unit SWINGat first, then press and button at theSWING same time toward the indoor unit, until hear a beep, and will appear on the remote controller display and the indoor LED display.

  1. This function helps carry away the accumulated dirt, bacteria, etc from the indoor evaporator.
  2. This function will run about 30 minutes, and it will return to the pre-setting mode. You can press button to cancel this function during the process.
    You will hear 2 beeps when it’s finished or cancelled.
    It’s normal if there is some noise during this function process, as plastic materials expand with heat and contract with cold.

We suggest operating this function at the following ambient conditions to avoid certain safety protection features.

Indoor unit Temp < 86oF (30oC)
Outdoor unit 41oF (5oC) < Temp < 86oF (30oC)

It’s suggested to utilize this function every 3 months.

8oC heating function

  1. Long press ECO button over 3 seconds to active this function, and 8C ( 46F ) will appear on the remote display.
    Do it again to deactivate this function.

  2. This function will auto start the heating mode when the room temperature is lower than 8oC (46F), and it will return to standby if the temperature reaches 9 C (48ooF).

  3. If the room temperature is higher than 18oC (64oF), the appliance will cancel this function automatically.

I SET function

Remember your favorite setting and run into it by press One button

Remember the favorite setting:

  1. In each mode (COOLING/ HEATING/ FAN/ DRY), long press ” I SET ” button over 3 seconds to remember it;
  2. When “AU” flashing appears on the remote controller display, that means the remote controller remember your favorite setting;
    Press any button to quit, and you can reset it by repeat 1, 2 operation.

Run into the favorite setting:

  1. In each mode (COOLING/ HEATING/ FAN/ DRY), one press ” I SET ” button to active;
  2. The appliance will run as your favorite setting and you will see [AU] flashing on the remote controller;
  3. Press it again or other buttons to cancel this function.

OPERATION INSTRUCTIONS

Attempt to use the air conditioner under the temperature beyond the specified range may cause the air conditioner protection device to start and the air conditioner may fail to operate. Therefore, try to use the air conditioner in the following temperature conditions.

Fixed air conditioner:

MODE

Temperature

| Heating| Cooling| Dry
---|---|---|---
Room temperature| 32°F ~ 80°F (0°C ~ 27°C)| 63°F ~ 90°F (17°C ~ 32°C)
Outdoor temperature| 19°F ~ 75°F (-7°C ~ 24°C)| T1 climate: 59°F ~ 109°F (15°C ~ 43°C)
T3 climate: 59°F ~ 125°F (15°C ~ 52°C)

Inverter air conditioner:

MODE

Temperature

| Heating| Cooling| Dry
---|---|---|---
Room temperature| 32°F ~ 80°F (0°C ~ 27°C)| 63°F ~ 90°F (17°C ~ 32°C)


Outdoor temperature

| 5°F ~ 75°F (-15°C ~ 24°C)

(Low temperature heating:

-4°F ~ 75°F (-20°C ~ 24°C)

| T1 climate: 59°F ~ 122°F (15°C ~ 50°C)

(Low temperature cooling:

5°F ~ 122°F (-15°C ~ 50°C)

T3 climate: 59°F ~ 131°F (15°C ~ 55°C)

With the power supply connected, restart the air conditioner after shutdown, or switch it to other mode during operation, and the air conditioner protection device will start. The compressor will resume operation after 3 minutes.
Characteristics of heating operation (applicable to Heating pump)

Preheating:
When the heating function is enabled, the indoor unit will take 2~5 minutes for preheating, after that the air conditioner will start heating and blows warm air.

Defrosting:
During heating, when the outdoor unit frosted, the air conditioner will enable the automatic defrosting function to improve the heating effect. During defrosting, the indoor and outdoor fans stop running. The air conditioner will resume heating automatically after defrosting finish.

Emergency button:
Open the panel and find the emergency button on the electronic control box when the remote controller fails . (Always press the emergency button with insulation material.)

Current status Operation Respond Enter mode
Standby Press the emergency button

once

| It beeps briefly once.| Cooling mode
Standby

(Only for heating pump)

| Press the emergency button

twice in 3 seconds

| It beeps briefly twice.| Heating mode
Running| Press the emergency button

once

| It keeps beeping for a while| Off mode

Klimaire-KIWU-KOIU-Series-Split-Type-Room-Air-
Conditioner-46

Mark of Superior Quality

2190 NW 89 Place, Doral, FL 33172 – USA
Tel: (305) 593 – 8358
www.klimaire.com
[email protected]

The Klimaire logo is a registered Trademark of Klimaire Products Inc. Copyright 2023 Klimaire Products Inc.

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
For more information please visit www.klimaire.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KLiMAiRE User Manuals

Related Manuals