Settings
Detection area, hold time and daylight sensor can be set using DIP switches on the sensor. Note that reducing the detection area will also reduce the sensitivity.

  1. Detection area
    I: up to 100%
    I upt075%
    111z up to 50%
    IV: up t0 25%

  2. Hold time
    Refers to the time period the lamp remains at 100% illumination after no motion detected
    I 5s
    II:13S
    III: 1min
    IV: 3mins
    V: 20mins
    VI: 30mins

  3. Daylight sensor
    The sensor can be set only to allow the lamp to illuminate below a defined ambient brightness threshold. The settings are as follows:-
    I: 2Lux, dakness operation only or open at 10Lux and close at 20Lux
    II: 10Lux, dakness operation only or open at 25Lux and close at 75Lux
    I: 25Lux, twilight operation or open at 50Lux and close at 100Lux
    IV: 50Lux, twilight operation or open at 100Lux and close at 200Lux
    V: 100Lux, brightness operation or open at 150Lux and close at 300Lux
    VI: Disable When set to Disable mode, the daylight sensor will switch on the lamp when motion is detected regardless of ambient lamp levels.

  4. Mode
    Select motion mode or photocell mode.
    I: Motion function is available only.
    Il: Photocell is available only.

Care and Safety

We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish For your safety, always switch off the power supply before changing lightbulbs, or cleaning
‘Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.

Warning
Please read these instructions carefully before commencing any work
“This unit must be fitted by a competent and qualified electrician
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge.
If you are in any doubt, please consult a qualified electrician
The sensor should not be modified in any way.
The sensor should be connected to a stable power supply (220-240V~50Hz).
Microwaves cannot pass through metal or brick walls if thicker than 20cm. They will pass through thinner walls but there will be some attenuation.
Installation inside a glass of plastic housing will resulting a reduction of detection sensitivity. Expect a reduction of 20% for every 3mm of thickness.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

Installation

Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.

  • If installing directly to product, create knock out hole in desired location so microwave sensor can be installed.
  • Remove nut from thread and place threaded end through created knock out. Refit nut from other side and tighten o secure.
  • Wire as detailed wiring diagram.

Wiring
Having correctly identified the wiring from your existing light fitting, connect to the connection block inside the product in the following way:
Please note: termination is not supplied. If you are not connecting the sensor to another unit then the switched live (S/L) wire will need to be terminated, saxby lighting 103850 MW Sensor - fig4

Check that…

  • You have correctly identified the wires.
  • The connections are tight.
  • No loose strands have been left out of the connection block

Technical Specifications

Voltage: 220-240V 50Hz a.c.
Load: 400W (inductive), BOOW (resistive)
HF System: 5.8GHz+75MHz, ISM wave band
Transmitting Power: <0.5mwW
Power Consumption: < 0.5W (standby)
Detection zone: Max. (D x H): 12m x 10m
Detection sensitivity: 25% /50% / 75% / 100%
Hold Time: 5s/30s/1min / 3mins / 20mins / 30 mins.
Daylight sensor. 2Lux /10Lux / 25Lux/ 50Lux / 100Lux / Disable
Daylight open/close: 10Lux/ 50Lux; 25Lux / 75Lux; 50Lux / 100Lux; 100Lux /

200Lux; 150Lux / 300 Lux; Disable.
Mounting height:| 6m Max.
Motion detection:| 0.5~3m/s
Detection angle:| 150° (wall installation) / 360° (ceiling installation)
Operating temperature:|  -25°C to +60°C
IP rating:| 65

Override Function
Quick switch ON/OFF 3 times within 2sec to override sensor function. Lights will switch on all the time. Power off and on again to recover sensor function.
Factory Setting
Detection Area: 100%, Hold Time: 5S, Daylight Sensor: Disable, Mode Settings: Motion
Detection Pattern

1) Ceiling mounting 2) Walling mounting
Horizontal installation: 2m

Sensor range setting: 100%/75%/50%/25%

V1 29/07/2022
UK Manufacturer: BH17 78Y
EU Manufacturer: Brilliant AG,
Brilllantstrasse 1, D-27442 Gnarrenburg
www.seabylighting.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

saxby lighting User Manuals

Related Manuals