INSTRUCTIONS OF INSTALLATION AND USE
ATTENTION!
The safety of the device can only be guaranteed on condition that to be
respected the following instructions, both stages of installation and use
therefore it is highly recommended to keep them.
WARNING:
To carry out the installation, and whenever an operation in the device is
carried out, make sure of having disconnected the electric power.
The device cannot be in any case modified or forced, any modification might
jeopardize the safety system making it dangerous. FLOS declines any
responsibility on modified products.
The device has been designed for inside.
IP20 Ordinary.
Class Ill luminaire: Device with a very low safety voltage. Connect the main
cables to the remote led power supply SELV under the EN 61347-2-13 standard,
respecting the right polarity (red positive –
black negative). Devices with a very low safety voltage showing the (BTS) mark
should not be connected to earthing conductors.
If the flexible cable or cord of this luminaire is damaged, it should be
exclusively replaced by the manufacturer or his technical service or a
qualified person in order to avoid any risk.
**** The luminaire should only be used with Flos accessories or components.
The symbol shown on the device indicates that the product must be eliminated
differently from the rest of the urban waste.
CLEANING INSTRUCTIONS
Use only a soft cloth to clean the appliance. For stubborn dirt, dampen the
cloth with water and clean only the reflector and the outer part of the
appliance.
Do not clean or touch the LED/light source in any way.
Warning: do not use alcohol or other solvents.
The light source contained in this luminaire shall only be replaced by the
manufacturer or his service agent or a similar qualified person.
Please refer to the product label to check the electrical specifications
OBLIQUE BASIC
USB Type C Charger
Max 18W
Use only original Flos accessories. Plugs included according to the version of the country.
| Replaceable (LED only) light source by a professional
---|---
| Replaceable control gear by an end-user
With the lamp off, pressing the button once, it will turn on with the last programmed intensity. With the lamp on, pressing the button once it will turn off.
With the lamp on or off, pressing the button twice in less than 1 second, the lamp will turn on at 100% intensity. If we press again twice in less than 1 second, the lamp will return to the previous intensity
With the lamp on or off, keeping the button pressed, the intensity will increase until it reaches 100%, and it will blink twice.Releasing and pressing the held button again will lower the intensity to 1% and will blink twice.
TIMER MODE
With the lamp on or off, pressing the button 4 times, you will enter the timer mode. The light will blink to confirm that you are in timer mode.
After blinking (Timer mode activated), press the button once for each hour you want to program and wait for the confirmation blink. Wait 5 seconds or press twice in less than 1 second to exit the timer mode. The light will blink once for every hour you have programmed (x pulses = x hours). Within the timer mode, the light intensity will remain at 100%.
EXAMPLE TO SCHEDULE 2 HOURS
Press the power button 4 times and wait for it to blink. This means that we are that we are in timer mode.
To program the lamp to turn off within two hours since being turned on, press once and wait for it to blink. Press again and wait for it to blink. If you wish to program more hours, press once for each hour you want to program.
Wait 5 seconds or double click to configure and exit. The light will blink 2 times depending on the setting, once every hour you have scheduled.
DISABLE TIMER MODE
To de-program the timer mode, press 4 times and wait 5 seconds.
ATTENTION: If you disconnect the power supply cable, you will lose the
settings you have chosen.