The Outdoor Sensor is a device that provides temperature and humidity readings for outdoor conditions. It consists of a display console and a remote sensor. The display console requires 3 AAA batteries, while the remote sensor requires 2 AA batteries. The device uses wireless communication to transmit data between the display console and the remote sensor.
NOTE: Prepare new and high-quality alkaline batteries. Do not mix old and new batteries. Heavy-duty or rechargeable batteries are not recommended.
POWER UP
Please must follow the bellow steps to power on the device, otherwise outdoor sensor may not receive readings.
- Step 1: Remove the battery door on the back of the display, insert 3 new AAA batteries in the back of the display console (please take note of the battery polarity before inserting the batteries).
- Note: The display will beep once and all of the LCD segments will light up for few seconds to verify all segments are operating properly, then display indoor temperature and humidity immediately.
- Step 2: Take out the metal stand inside the battery compartment and screw it into the hole at the main unit backside. Replace the battery door.
- Step 3: Remove the battery door of remote sensor, and set the channel of sensor to CH1, then insert 2 new AA batteries in the back of the sensor within 3 MINUTES.
Note:
- Make sure outside sensor and weather station main unit are at the same channel.
- Do not touch any buttons until the remote sensor reports in, otherwise the remote sensor searching will be terminated. When the remote sensor data has been received, all further settings can be performed.
- The display main unit will automatically receive remote sensor signal when sensor is powered up. The receiving status will last for max 3 minutes ( signal sensor will flash), if no signal received within 3 minutes, it will stop receiving, now you can press and hold the “CH/▲” Button 3 seconds to start receiving outside signal again.
TROUBLESHOOTING GUIDE
Problem | Possible Solution |
---|---|
Outdoor sensor signal is lost or showing dashes (‐ ‐) on the display | 1. |
Resync the unit. Press and hold the “CH/▲” button for 5‐6 seconds to resynchronize. The sensor search icon will flash while searching and be solid when sensor signal is received. Please wait several minutes for the sensor to report in or the search icon to turn off.
2. If you regain connection while the sensor is mounted, great. If the the synchronization fails, bring the sensor within 10 feet of the weather station and try the bellow methods:
| 1) Remove the batteries of Sensor, wait 10 seconds. Then press and hold the “CH/▲” button for 5‐6 seconds, then reinsert the batteries of sensor. (Please make sure the sensor and display console have the same channel.)
2) Factory Restart: Firstly remove all the batteries of sensor and display console. Then set the channel of Sensor to “CH1”. Reinsert the batteries of display console and press “CH/▲” button to choose “CH1”. Then reinsert the batteries of sensor, allow the whole set device to sit together for 30 minutes to establish a strong connection.
3. Make sure both display console and sensor are placed at least 3ft/0.9m away from electronics that may interfere with the wireless communication, such as computers, TVs, microwaves, other wireless transmitters or receivers, etc.
4. Make sure the sensor is not transmitting through solid metal or thick walls. Radio Frequency (RF) Sensors cannot transmit through metal barriers or thick walls. (Please refer REMOTE SENSOR INSTALLATION)
---|---
Outdoor temperature and humidity always keep cycling/how to exit the CYCLE
mode| “ ” cycle symbol means that weather station enter channels cycle mode,
it will display the values of 3 channels in order every 10 seconds.
Press the “CH/▲” button to cancel cycle symbol.
Temperature reads too high in the daytime| Make sure both the display console
and sensor are placed out of direct sunlight and away from any heat sources or
vents.
Indoor and outdoor temperature and humidity do not agree| Allow up to two
hours for the sensor to stabilize due to signal filtering. The indoor and
outdoor temperature sensor should agree within 4℉. And indoor and outdoor
humidity sensor should agree within 10%.
Inaccurate weather forecast| The weather forecast is an estimate or
generalization of weather changes in the next 12 to 24 hours, with an accuracy
rate of about 70‐75%. It is simply a tool for projecting weather conditions
and is never to be relied upon as an accurate method to predict weather.
Display console contrast is weak| Battery is low, replace a new set of
batteries.
Incorrect weekday display| Press and hold “RCC/SET” button to select the
correct Year (year range: 2000‐2099).
If your BALDR weather station still can’t be worked well after trying the
above troubleshooting steps, please contact the seller on your order page or
email us by
baldrservice@baldr.com, or message us via WhatsApp: +8618664978063 for help.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>