ASHLY KLR 2000 Stereo Power Amplifier User Manual

June 12, 2024
ASHLY

ASHLY logo

KLR-Series Amplifiers
KLR 2000, KLR 3200, KLR 4000, KLR 5000
Operator ManualASHLY KLR 2000 Stereo Power Amplifier Ashly Audio Inc.
847 Holt Road, Webster, NY 14580-9103
Toll Free800-828-6308, Telephone 585-872-0010, FAX 585-872-0739
www.ashly.com
All Trademarks referred to herein, are the property of their respective owners.
All Rights Reserved
r0515

This manual uses a Perpetual Table Of Contents. Each page has a copy of the manual’s contents in a gray box just like this one. The section you are in will always be bold with the other sections “grayed out.” The feature allows you to jump directly to another
section without having to return to a Table Of Contents page.

Important Safety Instructions

This power amplifier can produce dangerous output voltage, power and sound pressure levels. In order to minimize the risk of injury, damage, or hearing loss, please read the entire owner’s manual.

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the device.

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
  6. Do not use this apparatus near water.
  7. Clean only with dry cloth.
  8. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  9. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  10. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
  11. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  12. Only use attachments/accessories specified by the manufacturer.
  13. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
  14. Unplug this apparatus during lightning storms or when unused for long periods of time.
  15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
  16. To completely disconnect this apparatus from the AC mains, disconnect the power supply cord plug from the AC receptacle.
  17. The mains plug of the power supply cord shall remain readily accessible.

Introduction

Congratulations on your purchase of an Ashly KLR-Series amplifier. The KLR- Series is made up of powerful, high-efficiency, lightweight amplifiers incorporating the latest technologies. We are confident that you will be pleased with the high performance, superb sound quality, reliability, and more.
About Ashly
Ashly Audio was founded in 1974 by a group of recording engineers, concert sound professionals, and electronics designers. The first products were elaborate custom consoles for friends and associates, but business quickly spread to new clients and the business
grew. The philosophy we established from the very beginning holds true today: to offer only the highest quality audio tools at an affordable cost to the professional user – ensuring reliability and long life. More than thirty years later, Ashly remains committed to these principles.
FCC Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in both a commercial and  residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
The KLR Series
KLR-Series amplifiers are high-efficiency, lightweight high power amplifiers incorporating the latest amplifier technologies.
The series provides a power range of 1000 to 2500 watts per channel at 2 ohms (20Hz20kHz, 1% THD). The KLR series is available in 2 channel versions at four power points.
All models will drive 2, 4, or 8 ohm loads.  *The KLR 3200 can also be used as a two channel 70V distributed output amplifier providing up to 800W per channel. For 70V applications, Ashly recommends setting the amplifier’s HiPass filter switch to 50Hz (see page 5).

KLR-Series Power Ratings (per channel)|
---|---
| Stereo| Mono Bridged
Model| 70V| 8Ω| 4Ω| 2Ω| 4Ω
KLR 2000| X| 350W| 600W| 1000W| 2000W
KLR 3200*| 800W| 650W| 1100W| 1600W| 3200W
KLR 4000| X| 850W| 1400W| 2000W| 4000W
KLR 5000| X| 1000W| 1700W| 2500W| 5000W

  • Inputs are via 3-pin Euroblock, XLR, and ¼” TRS connectors.
  • Switch mode power supply provides high efficiency and low weight
  • Output connectors are four pin Speakon type.
  • Rear panel switches include: Gain and Operation Mode, Limiter, and HPF.
  • Forced air cooled (front panel intake, rear panel exhaust)
  • Front panel indicators for output level, clip/protect, and power on/off
  • Gain selectable switch for both channels
  • Removable dust filters on front panel
  • Rack ears for permanent installation in a standard 2RU 19”(rack mount width) enclosure

Protection
KLR-Series Amplifiers come standard with several protection circuits:
Output over-current protection
  DC output protection
Chassis internal temperature monitoring
  Inrush limiting
  Mains circuit breaker (Mains fuse used in KLR-5000)
WARNING: Do not remove the mains connector ground.

Physical Description

Each model in the KLR-Series is 2RU. The model number is indicated on the left side of the front panel
Amplifier Front PanelASHLY KLR 2000 Stereo Power Amplifier - Front
Panel

  1. Mounting Holes – For rack mounting.
  2. Air Inflow Vents – Cool air enters here.
  3. Channel Attenuators – These knobs adjust the attenuation of the input signal of each channel from œ to 0.
  4. Signal, Clip, and Protect LEDs – Indicates output level of -30, -20, -10dB, Clip, and amplifier protect.
  5. Power Switch and LED – Switches the unit on or off. The KLR 2000, KLR 3200, and KLR 4000 use a switch with a built in mains circuitbreaker. The KLR 5000 uses a non-breaker switch and an internal mains fuse instead.
  6. Rack Handles – Handles on newer models can be removed using a 3mm hex wrench.

Amplifier Rear Panel (Note: KLR 5000 rear panel has different feature locations)

ASHLY KLR 2000 Stereo Power Amplifier - Rear Panel

  1. AC Cord – For connection to the AC mains
  2. CH 1, CH 2, Bridged Output Connector – This connector provides the amplifier’s Channel 1, channel 1 and 2, or bridged output.
  3. CH 2 Output Connector – This connector provides the amplifier’s Channel 2 output.
  4. Air Outflow Vents – Warm air exits here.
  5. Gain Switch – The Gain switch sets the gain for both channels. Gain selections vary between models. Check specifications for each model.
  6.  Mode Switch – This switch selects the amplifier’s operating mode (Bridge, Stereo, or Parallel Mono).
  7. 3-Pin Euroblock Input Connectors – These connectors are used for balanced or unbalanced input signals. For parallel mode or bridged mode, use INPUT 1 only.
  8. Combination XLR, 1/4” TRS Input Connectors – These connectors are used for balanced or unbalanced input signals, and are wired in parallel with the Euroblock connector.
  9. Limiter Switch – This switch engages the limiter. There is a separate limiter for each channel.
  10. HPF Switch – This switch selects the input HiPass filter to 30Hz, 50Hz, or Off.

Installation

KLR-Series amplifiers are designed for use in both fixed and mobile sound systems. Each amplifier is shipped (unless otherwise specified) with the following factory settings:

Front panel: Rear panel:

On/Off Switch = Off
Attenuators = œ| High Pass Filter(s) = Off
Gain Selector = Max Gain Position
Mode Selector = Stereo
Limiter Switch = Off

Before connecting to mains power, make sure that the switches are set to the configuration needed for your particular application. Always switch the amplifier off before making any changes to the settings. Failure to do so could result in damage to the unit or other components in your system. CAUTION: When mounting or connecting the amplifier, always disconnect it from the mains. Use four screws and washers when mounting the amplifier to the front rack rails. Rear support is also recommended, especially for mobile or touring use. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
Requirements
KLR-Series amplifiers have specific physical, electrical and signal requirements for proper operation. These requirements will vary depending on your specific application, setup, and the settings on the amplifier. When setting up and testing your system, please take special care to double check all connections and settings. Please refer to the specifications section of this manual for specific input, output and other figures.
Installation Density
KLR-Series amplifiers produce substantial power output from a small chassis. When driven at the higher-end of their potential, they do produce heat that must be dissipated. In cases where multiple KLR amplifiers are mounted together (or a single KLR with other equipment), it is recommended that a 1RU space is left between units to allow for proper air circulation. If the amplifier overheats, it will go into ‘thermal’ protect mode to prevent damage to itself and any connected components and speakers.ASHLY KLR 2000 Stereo
Power Amplifier - DimensionsTypical Applications (Note: KLR 5000 not shown – see page 5) ASHLY KLR 2000 Stereo Power
Amplifier - Typical Applications 1The most common use of a KLR-Series amplifier is a 2-channel source driving 2 speaker channels. In this illustration, the amplifier is receiving a stereo signal and is driving two stereo speakers. The amplifier is in STEREO mode.ASHLY KLR 2000 Stereo Power Amplifier - Typical
Applications 2Another use of a KLR-Series amplifier is a single channel source driving both speaker channels. In this illustration, the amplifier is receiving a signal and is driving both channel speakers with the same signal. The amplifier is in PARALLEL mode.
ASHLY KLR 2000 Stereo Power Amplifier - Typical Applications
3
KLR-Series amplifiers are well suited to BRIDGED operation to drive a speaker load such as a subwoofer. This illustration shows a KLR driving a signal in BRIDGED mode. Note the special wiring to the channel 1 connector for Bridge mode. Minimum Bridged load impedance is 4Ω (2Ω per channel).
Connectors & Polarity
KLR-Series amplifiers utilize three types of professional audio connectors. For the inputs, 3-pin Euroblock connectors are utilized with their polarity clearly marked on the amplifier’s rear panel, and combination XLR and 1/4” phone jack are all wired in parallel. Outputs are four pin Speakon type connectors. The polarity for these connections is marked on the unit’s chassis. Note that polarity changes when the unit is operated in BRIDGED mode. Be sure to read the Operation section of this manual for important information on the operating modes. ASHLY KLR 2000 Stereo Power Amplifier -
ConnectorsSpeaker Connections (Note: KLR 5000 speaker outputs not shown – see page 5)![ASHLY KLR 2000 Stereo Power Amplifier

  • Connections 1](https://manuals.plus/wp-content/uploads/2023/06/ASHLY- KLR-2000-Stereo-Power-Amplifier-Connections-1.jpg) Stereo Speaker Wiring
    In this mode, the amplifier’s channels operate fully independent of each other. Each signal enters the unit and is amplified separately and wired using different connectors.ASHLY KLR 2000 Stereo Power Amplifier - Connections
3 Stereo Speaker Wiring Using Single 4-Conductor Speaker Cable
    In this mode, the amplifier’s channels still operate independent of each other. Each signal is amplified separately, however both channels are wired using the Channel 1 connector.
    ASHLY KLR 2000 Stereo Power Amplifier - Connections 2 Bridged (Mono) Mode
    In this mode, a single input is connected to channel 1 and is connected to the two output channels that have been “Bridged” together using the Channel 1 connector. Minimum Bridged load impedance is 4Ω.

Troubleshooting

Situation Indication Action
No Sound Signal LED not lit Clip LEDs not lit Check AC plug. Confirm that AC

outlet works by plugging in another device.
Signal LED not lit| Make sure the signal source is operating and try another cable. Check position of Volume Pots.
Signal LEDs responding to signal level| Check the speaker wiring for breaks. Try another speaker and cable.
Protect LED is lit| Overheating will cause protective muting. Check for proper ventilation.
No Channel Separation| No Channel Separation| Check the mode indicators on the back panel and make sure the mode selector on the rear panel is in the stereo position. Make sure other equipment in the signal path such as mixers and preamps are set for stereo, not mono
Distorted Sound| Power LED is lit| A faulty speaker or a loose connection could cause this. Check the wiring and try another speaker.
Signal LEDs responding to signal level| The signal source might be clipping. Keep the volume pots at least halfway up so that the source does not have to be overdriven.
Clip LEDs not lit| Keep the volume pots at least halfway up and try changing input sensitivity with the gain selector on the rear.
Hiss| Hiss| Unplug the amplifier input to confirm that the hiss is coming from the source or from a device upstream. Erratic or popping noises indicate an electronic fault in the offending unit. To keep the noise floor low. operate the primary signal source at full level. without clipping. Avoid boosting the signal further between the source and the amplifier.
Squeals and Feedback| Squeals and Feedback| Microphone feedback should be eliminated with mixer controls. If noise continues to build up with no microphone gain, there is a serious fault in the signal processors or cables. Working in succession from the signal source towards the amplifier and check each device in the signal path by reducing its gain or by unplugging it.

Specification Table

| KLR 2000| KLR 3200| KLR 4000| KLR 5000
---|---|---|---|---
Power Output Per Channel| | | |
Stereo Mode, both channels driven| | | |
8Ω, 20Hz – 20kHz, 1% THD| 350W| 650W| 850W| 1000W
4Ω, 20Hz – 20kHz, 1% THD| 600W| 1100W| 1400W| 1700W
2Ω, 20Hz – 20kHz, 1% THD| 1000W| 1600W| 2000W| 2500W
70V Output, 20Hz – 20kHz, 1% THD, per channel| X| 800W| X| X
Bridged Mono Mode| | | |
4Ω, 20 Hz – 20 kHz, 1% THD| 2000W| 3200W| 4000W| 5000W
  Line Current Draw (all channels driven @4Ω)| | | |
Idle (120VAC 60Hz)
| 0.99A| 0.92A| 1.05A| 1.14A
1/8th  Power Pink Noise  (120VAC 60Hz) | 9.7A| 11.4A| 14.0A| 17.5A
1/3 Power Sine Wave (120VAC 60Hz)
| 14.9A| 16.6A| 19.8A| 24.7A
 Thermal Dissipation (all channels driven @4Ω)| | | |
Idle (BTU/hr)| 164| 136| 171| 215
1/8th  Power Pink Noise (BTU/hr)| 1876| 2063| 2489| 3111
1/3 Power Sine Wave (BTU/hr)| 2880| 3001| 3516| 4395
Input Gain Switch| 1V, 26dB, 20dB| 1V, 32dB, 26dB| 1V, 32dB, 26dB| 1.4V, 32B, 26dB
Signal to Noise Ratio  (20Hz-20kHz, rated power @ 8Ω unweighted)| >108 dB|

109 dB| >109 dB| >110 dB
Output Circuitry:| Class AB| 2 Step Class H| 2 Step Class H| 2 Step Class H
Frequency Response 1W @ 8Ω|         20Hz-20kHz  (-3dB down point)| /- 0.3dB
5Hz – 70kHz
Damping Factor – 100Hz @ rated power @8Ω| > 380
THD 20Hz-20kHz, 10dB below rated output @4Ω| <0.05%
Input Impedance| 12 kΩ, balanced
HPF (30Hz, 50Hz, Off)| 12dB/Oct
Amplifier Protection| Output Overcurent, DC Output, Chassis Temperature, Mains Breaker  (KLR-5000 uses Internal Mains Fuse Instead of Breaker)
Cooling| Variable Speed Fan, Front to Rear Air Flow
Front Panel Indicators| Prot/Clip, Signal, Power
Attenuators| Per channel: front panel
Input Connectors, each channel| 3- Pin Euroblock, XLR, ¼” TRS Phone Jack
Output connectors, each chann| Four pin Speakon type
Operating Temperature/Humidit| Temperature: -10C – +40C / Humidity: 0% – 90%
Power Cable Connector| 3-Prong NEMA  5-15 (5-20 for KLR-5000)
Dimensions| 19” x 3.5” x 16” (482mm x 88mmx x407mm)
Weight| 24 lbs (10.9kg)| 26.4 lbs (12kg)| 26.7 lbs (12.1kg)| 28.2 lbs (12.8kg)

  • For 230VAC 50Hz models, divide Line Current Draw values by 2.
    All Specifications Subject to Change or Improvement Without Notice.

Ashly Audio Inc. LIMITED WARRANTY (USA ONLY)
(Other countries please contact your respective distributor or dealer.)
For units purchased in the USA, warranty service for this unit shall be provided by ASHLY AUDIO, INC. in accordance with the following warranty statement.
ASHLY AUDIO, INC. warrants to the owner of this product that it will be free from defects in workmanship and materials for a period of FIVE years from the original-date-of-purchase. ASHLY AUDIO INC. will without charge, repair or replace at its discretion, any defective product or component parts upon prepaid delivery of the product to the ASHLY AUDIO, INC. factory service department,  accompanied with a proof of original-date-of-purchase in the form of a valid sales receipt. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.
EXCLUSIONS: This warranty does not apply in the event of misuse, neglect, or as a result of unauthorized alterations or repairs made to the product. This warranty is void if the serial number is altered, defaced, or removed. ASHLY AUDIO, INC. reserves the right to make changes in design, or make additions to, or improvements upon, this product without any obligation to install the same on products previously manufactured.
Any implied warranties, which may arise under the operation of state law, shall be effective only for FIVE years from the original-date-of-purchase of the product. ASHLY AUDIO, INC. shall be obligated to only correct defects in the product itself. ASHLY AUDIO, INC. is not liable for any damage or injury, which may result from, or be incidental to, or a consequence of, such defects. Some states do not allow limitations on how long an implied warranty lasts, or the exclusion, or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
OBTAINING WARRANTY SERVICE:
For warranty service in the United States, please follow this procedure:

  1. Return the product to ASHLY AUDIO, INC. freight prepaid, with a written statement describing the defect and application that the product is used in. ASHLY AUDIO, INC. will examine the product and perform any necessary service, including replacement of defective parts, at no further cost to you.
  2. Ship your product to: ASHLY AUDIO, INC.
    Attention: Service Department
    847 Holt Road
    Webster, NY 14580-9103

ASHLY logoASHLY KLR 2000 Stereo Power Amplifier - Typical Applications
4 KLr 2000, KLr 3200
KLr 4000 , KLr 5000

KLR SERIES
Two-Channel, high-PerformanCe Power amPlifiers

The KLR Series are lightweight, high-performance amplifiers incorporating the latest technologies deliveringquality and value at an affordable price. Whether your application is professional audio or fixed performance installation, KLR amplifiers are optimized to provide reliable audio performance with sonic perfection.
Covering a power range from 1000 to 2500 Watts per channel at 2 Ohms the KLR-2000, KLR-3200, KLR-4000 and KLR-5000 are perfectly suited for a wide range of sound reinforcement. All four KLR amplifiers are optimized to deliver high levels of sustained power, extraordinary audio performance, and road- proven reliability into 2, 4, or 8 Ohm loads and are housed in a a uniform, rugged 2RU chassis. Each KLR amplifier uses a switch mode power supply which assures you of flawless lows, punchy mids and pristine highs. The output topology of the KLR-2000 is Class-AB, while the KLR-3200, 4000, and 5000 are a 2-step Class-H design.
KLR Features:

  • Rated for 2 Ohms operation
  • Balanced inputs via 3-pin Euroblock
  • Combo XLR/TRS connectors
  • Neutrik® speakON® type output connectors
  • Switch-mode power supply with extensive protection circuitry
  • On/off limiter switch
  • Forced-air cooled (front-in, rear-out)
  • Removable dust filters, easy to clean
  • Front-mounted attenuators
  • Removable amp handles for permanent installation
  • Optional locking front panel volume knobs
  • Safety/Compliance: cCSAus, CE, FCC, RoHS

Specifications
Note: 0dBu = 0.775 VRMS

Frequency Response (1W @ 8 Ohms)| 20Hz–20kHz (+0.3dB) 5Hz–70kHz (-3dB down point)
Damping Factor| >380 (100Hz @ rated power @ 8 Ohms)
THD (20Hz–20kHz)| 10dB below rated output @ 4 Ohms <0.05%
Input Impedance| 12k Ohm, balanced
Max Input Level| +21dBU
HPF| 30Hz, 50Hz, Off (12dB/Oct)
Amplifier Protection| Output Overcurrent, DC Output, Chassis Temperature, Mains Breaker (KLR-5000 uses internal Mains fuse)
Operating Temp/Humidity| -10C to +40C/Humidity: 0% to 90%
Front Panel
Airflow/Cooling| Front-to-Rear, Variable Speed Fan
Front Panel Indicators| Protection/Clip, Signal, Power
Attenuators| Front Panel (each channel)
Rear Panel
Input Connectors (each Ch)| 3-pin Euroblock, XLR, ¼” TRS Phone Jack
Output Connectors| 4-pin SpeakON® type (each channel)
Power Cable Connector| 3-prong NEMA 5–15, 5–20 for KLR-5000
Weights, Dimensions & Power
Dimensions| 19” W x 3.5” H x 16” D (482mm x 88mm x 407mm)
Unit Weight| KLR-2000: 26.2lbs (11.9kg) KLR-3200: 26.4lbs (12kg) KLR-4000: 26.6lbs (12kg) KLR-5000: 28lbs (12.7kg)
Shipping Weight| KLR-2000: 31lbs (14kg) KLR-3200: 33lbs (15kg) KLR-4000: 33lbs (15kg) KLR-5000: 35lbs (16kg)
Power Requirements| 120VAC or 240VAC, ±10% (factory set) 50–60Hz
KLR Models| 2000| 3200| 4000| 5000
---|---|---|---|---
Max Output Power: Per Channel, 20Hz–20kHz, 1%THD, Both Channels Driven
2 Ohms| 1,000W| 1,600W| 2,000W| 2,500W
4 Ohms| 600W| 1,100W| 1,400W| 1,700W
8 Ohms| 350W| 650W| 850W| 1,000W
Bridge Mode, 20Hz–20kHz, 1%THD
4 Ohms| 2,000W| 3,200W| 4,000W| 5,000W
Constant Voltage Options: Per Channel, 20Hz–20kHz, 1% THD
70V| —| 800W*| —| —
Line Current Draw: 120VAC 60Hz, All Channels Driven @ 4 Ohms
Idle| 0.99A| 0.92A| 1.05A| 1.14A
1/8th Power (Pink Noise)| 9.7A| 11.4A| 14.0A| 17.5A
1/3 Power (Sine Wave)| 14.9A| 16.6A| 19.8A| 24.7A
Thermal Dissipation: BTU/hr, All Channels Driven
Idle| 164| 136| 171| 215
1/8th Power (Pink Noise)| 1876| 2063| 2489| 3111
1/3 Power (Sine Wave)| 2880| 3001| 3516| 4395
Additional Specs
Signal-to-Noise

(20Hz–20kHz, unweighted)

| >108dB| >109dB| >109dB| >110dB
Input Gain Switch| 1V, 20dB, 26dB| 1V, 26dB, 32dB| 1V,  26dB, 32dB| 1.4V, 26dB, 32dB
Output Circuitry| Class AB| 2-Step Class H| 2-Step Class H| 2-Step Class H

ASHLY KLR 2000 Stereo Power Amplifier - Typical Applications
5

  • The KLR 3200 can also be used as a two-channel 70V distributed output amplifier providing up to 800W per channel. ©2014 All features, specifications and graphical representations are subject to change without notice.

KLR SERIES

ARCHITECT & ENGINEERING SPECS

KLR-2000
The two-channel power amplifier shall incorporate the latest amplifier technology to deliver a minimum power of 1,000 Watts per channel into 2 Ohm loads, 600 Watts RMS per channel into 4 Ohm loads, or 350 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for parallel mono and bridging modes. When switched into bridged-mono mode, the amplifier shall deliver 2,000 Watts into a 4 Ohm load. The amplifier protection shall include output over-current, DC output, chassis temperature, and a mains circuit-breaker. Frequency response shall be 20Hz­20kHz (1W @ 8 Ohms). The Signal-to-Noise Ratio shall be greater than 108dB at rated power into 8 Ohms (unweighted). THD shall be less than 0.05% into 4 Ohms, 20Hz­20kHz and 10dB below rated power. The amplifier shall have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable switch on the rear panel. The inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outputs shall be four pin SpeakON type connectors. LED type indicators shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel mounted, removable dust filters. The power amplifier shall weigh 26.2lbs/11.9kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power requirement shall be 120VAC or 240VAC ±10%, 50­60Hz, factory set.
The power amplifier shall be the Ashly KLR-2000.
KLR-3200
The two-channel power amplifier shall incorporate the latest amplifier technology to deliver a minimum power of 1,600 Watts per channel into 2 Ohm loads, 1,100 Watts RMS per channel into 4 Ohm loads, or 650 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for parallel mono and bridging modes. When switched into bridged-mono mode, the amplifier shall deliver 3,200 Watts into a 4 Ohm load. The amplifier protection shall include output over-current, DC output, chassis temperature, and a mains circuit-breaker. Frequency response shall be 20Hz­20kHz (1W @ 8 Ohms). The Signal-to-Noise Ratio shall be greater than 109dB at rated power into 8 Ohms (unweighted). THD shall be less than 0.05% into 4 Ohms, 20Hz­20kHz and 10dB below rated power. The amplifier shall have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable switch on the rear panel. The inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outputs shall be four pin SpeakON type connectors. LED type indicators shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel mounted, removable dust filters. The power amplifier shall weigh 26.4lbs/12kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power requirement shall be 120VAC or 240VAC ±10%, 50­60Hz, factory set.
The power amplifier shall be the Ashly KLR-3200.
KLR-4000
The two-channel power amplifier shall incorporate the latest amplifier technology to deliver a minimum power of 2,000 Watts per channel into 2 Ohm loads, 1,400 Watts RMS per channel into 4 Ohm loads, or 850 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for parallel mono and bridging modes. When switched into bridged-mono mode, the amplifier shall deliver 4,000 Watts into a 4 Ohm load. The amplifier protection shall include output over-current, DC output, chassis temperature, and a mains circuit-breaker. Frequency response shall be 20Hz­20kHz (1W @ 8 Ohms). The Signal-to-Noise Ratio shall be greater than 109dB at rated power into 8 Ohms (unweighted). THD shall be less than 0.05% into 4 Ohms, 20Hz­20kHz and 10dB below rated power. The amplifier shall have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable switch on the rear panel. The inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outputs shall be four pin SpeakON type connectors. LED type indicators shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel mounted, removable dust filters. The power amplifier shall weigh 26.7lbs/12.1kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power requirement shall be 120VAC or 240VAC ±10%, 50­60Hz, factory set.
The power amplifier shall be the Ashly KLR-4000.
KLR-5000
The two-channel power amplifier shall incorporate the latest amplifier technology to deliver a minimum power of 2,500 Watts per channel into 2 Ohm loads, 1,700 Watts RMS per channel into 4 Ohm loads, or 1,000 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for parallel mono and bridging modes. When switched into bridged-mono mode, the amplifier shall deliver 5,000 Watts into a 4 Ohm load. The amplifier protection shall include output over-current, DC output, chassis temperature, and an internal mains fuse. Frequency response shall be 20Hz­20kHz (1W @ 8 Ohms). The Signal-to-Noise Ratio shall be greater than 110dB at rated power into 8 Ohms (unweighted). THD shall be less than 0.05% into 4 Ohms, 20Hz­20kHz and 10dB below rated power. The amplifier shall have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable switch on the rear panel. The inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outputs shall be four pin SpeakON type connectors. L.E.D type indicators shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel mounted, removable dust filters. The power amplifier shall weigh 28.2lbs/12.8kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power requirement shall be 120VAC or 240VAC ±10%, 50­60Hz, factory set.
The power amplifier shall be the Ashly KLR-5000.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>