AXOR 14873XXX Talis S2 Variarc Kitchen Mixer Tap Instruction Manual

June 12, 2024
AXOR

AXOR 14873XXX Talis S2 Variarc Kitchen Mixer Tap Instruction Manual
AXOR 14873XXX Talis S2 Variarc Kitchen Mixer Tap

Safety Notes

Gloves should be worn during installation to prevent crushing and cutting injuries.

Installation Instructions

  • The fitting must be installed, flushed and tested after the valid norms!
  • Important!* With water heaters of 5 liters the flow rate at the mixer should not exceed 5 l/min.
  • In this case the flow rate must be reduced at the isolation valve.

Technical Data

Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 – 0,5MPa (1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 80°C
Recommended hot water temp.: 65°C
Rate of flow: max. 5 l/min

Fault Cause Remedy
Insufficient water Spray former calcified, dirty Clean spray former,

exchanging if necessary
| Filter at the isolation valves soil| Clean the filter / exchange filter
Mixer stif| Cartridge defective, calcified| Exchange cartridge
Mixer dripping constantly with water heater switched of| Cartridge defective| Exchange cartridge
Water escaping in area of swivel spout| O-ring defective| Exchange cartridge
Water escaping at the threaded base| Adapter floor leaks| Check the adapter floor, replace if necessary
| O-ring at the connection hose defective| Exchange O-ring
Water escaping bels ow handle| Cartridge defective| Exchange cartridge

Symbol description

Do not use silicone containing acetic acid

Cleaning
Cleaning recommendations, see enclosed brochure

Assembly

Assembly
Assembly
Assembly
Assembly

Maintenance

Maintenance

  • The non return valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year).
  • When changing the spray former, it is imperative to use one made for this type of mixer.

Dimensions

Dimensions

Spare parts

Spare parts

  • XXX = Colors
  • 000 = chrome plated
  • 750 = Alux
  • 800 = stainless steel optic

Operation

Operation

When the storage tank is being heated, the spout will drip

Test certificate

| P-IX| DVGW| SVGW| ACS| WRAS| MCA| KIWA
---|---|---|---|---|---|---|---
14873XXX| P-IX 9539/I| | | | X| |

Hansgrohe · Postfach 1145 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282 · Telefax +49 (0) 7836/511440
E-Mail: [email protected] · Internet: www.hansgrohe.com