AXOR 10720000 Starck Shower Mixers Instruction Manual
- October 30, 2023
- AXOR
Table of Contents
**Instructions for use
assembly instructions**
Safety Notes
⚠ Gloves should be worn during installation to prevent crushing and cutting
injuries.
⚠ The shower system may only be used for bathing, hygienic and body cleansing
purposes.
⚠ Children as well as adults with physical, mental and/ or sensoric
impairments must not use this shower system without proper supervision.
Persons under the influence of alcohol or drugs are prohibited from using this
shower system.
⚠ The hot and cold supplies must be of equal pressures.
Installation Instructions
The fitting must be installed, flushed and tested after the valid norms!
Technical Data
Operating pressure: | max. 1 Mpa |
---|---|
Recommended operating pressure: | 0,1 – 0,5MPa |
Test pressure: | 1,6MPa (1 MPa = 10 bar = 147 PSI) |
Hot water temperature: | max. 80°C |
Recommended hot water temp.: | 65°C |
Rate of flow by 0,3 MPa: | approx. 26 l/min anti-pollution function |
Fault | Cause |
--- | --- |
Insufficient water | – Supply pressure inadequate |
pump has been installed check to see if the pump is working).
– Regulator filter dirty| – Clean filters
– Shower filter seal dirty| – Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe, or vice versa, when
mixer is closed| – Backflow preventers dirty or leaking| – Clean backflow
preventers, exchange if necessary
Spout temperature does not correspond with temperature set| – Thermostat has
not been adjusted| – Adjust thermostat
– Hot water temperature too low| – Increase hot water temperature to 42 °C to
65 °C
Temperature regulation not possible| – Temperature regulator dirty or
calcified| – Clean temperature regulator, exchange if necessary
– For new installations: basic body incorrectly connected (should be: cold
right, hot left) or installed with 180° rotation| – Install function block
turned through 180°
Safety stop button not operating| – Spring defective – Button calcified| –
Clean spring and/or button, exchange if necessary
Diverter stiff| – Cartridge defective| – Exchange cartridge
Diverter leaking| – Dirt or sedimentation on valve seat.| – Clean valve seat
or exchange diverter
Assembly
Montreux
Do not use silicone containing acetic acid!
Safety Function
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
Adjustment
After the installation, the output temperature of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat.
Maintenance
- To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
- The mixer is equipped with non return valves. The non return valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year). At this time, please also check the filter (A) situated on the MTC-thermoelement (94282000). After assembling the MTC-thermoelement, it is necessary to check the water temperature at the take off point as described under the headline „adjustment“. Before the adjustment, please check, if the warm water supply is activated and the maximum temperature of the warm water is available at the take off point.
Dimensions
Spare parts
XXX = Colors
000 chrome plated
090 chrome plated/gold plated
800 stainless steel optic
820 brushed nickel
830 polished nickel
**** Operation
Cleaning
see enclosed brochure.
Test certificate
| PA-IX| DVGW| SVGW| ACS| WRAS| MCA| KIWA
---|---|---|---|---|---|---|---
10720000| 9062/IAA| BT0550| | X| X| X| X
10726000| 9062/IAA| BT0550| | X| X| X| X
16820XXX| 9062/IAA| BT0550| | X| X| X| X
17720XXX| 9062/IAA| BT0550| | X| X| X| X
17725XXX| 9062/IAA| BT0550| | X| X| X| X
18750000| 9062/IAA| BT0550| | X| X| X| X
34725000| 9062/IAA| BT0550| | X| X| |
35720800| 9062/IAA| BT0550| | X| X| X| X
37720000| 9062/IAA| BT0550| | X| X| X| X
37725000| 9062/IAA| BT0550| | X| X| X| X
38720000| 9062/IAA| BT0550| | X| X| X| X
39720000| 9062/IAA| BT0550| | X| X| X| X
39725000| 9062/IAA| BT0550| | X| X| X| X
19706000| | | | | X| |
Hansgrohe · Postfach 1145 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282
· Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com · Internet:
www.hansgrohe.com
01/2011
9.09123.10
References