AXOR 17716090 CARLTON Highflow Thermostat Instruction Manual
- October 30, 2023
- AXOR
Table of Contents
AXOR 17716090 CARLTON Highflow Thermostat
Safety Notes
- Gloves should be worn during installation to prevent crushing and cutting injuries.
- The shower system may only be used for bathing, hygienic, and body cleansing purposes.
- Children as well as adults with physical, mental, and/ or sensory impairments must not use this shower system without proper supervision. Persons under the influence of alcohol or drugs are prohibited from using this shower system.
- The hot and cold supplies must be of equal pressure.
Installation Instructions
The fitting must be installed, flushed, and tested after the invalid norms!
Technical Data
- Operating pressure: max. 1 MPa
- Recommended operating pressure: 0,1 – 0,5MPa
- Test pressure: 1,6MPa(1 MPa = 10 bar = 147 PSI)
- Hot water temperature: max. 80°C
- Recommended hot water temp: 65°C
- Rate of flow by 0,3 MPa: approx. 58 l/minanti-pollution function
Symbol Description
- Do not use silicone-containing acetic acid!
Safety Function
Adjustment
- After the installation, the output temperature of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat.
Maintenance
- To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
- The mixer is equipped with nonreturn valves. The nonreturn valves must be checked regularly according to DIN EN 1717 in accordance with national regional regulations (at least once a year). At this time, please also check the filter (A) situated on the BTC-thermoelement(96633000). After assembling the theBTC-thermoelement, it is necessary to check the water temperature at the takeoff point as described under the headline„adjustment“. Before the adjustment, please check, if the warm water supply is activated and the maximum temperature of the warm water is available at the takeoff point.
Dimensions
Spare parts
Operation
For cleaning
see the enclosed brochure.
Assembly
Fault Cause Remedy
- Insufficient water – Supply pressure inadequate – Check water pressure (If a pump has been installed check to see if the pump is working).
- Regulator filter dirty – Clean filters
- Shower filter seal dirty – Clean filter seal between shower and hose
- Crossflow, hot water being forced into the cold water pipe, or vice versa, when the mixer is closed
- Backflow preventers are dirty or leaking
- Clean backflow preventers, exchange if necessary
- The spout temperature does not correspond with the temperature setting
- The thermostat has not been adjusted – Adjust the thermostat
- Hot water temperature too low – Increase hot water temperature to 42 ºC to 65 ºC
- Temperature regulation not possible – Temperature regulator dirty or calcified
- Clean temperature regulator, exchange if necessary
- For new installations: basic body incorrectly connected (should be: cold right, hot left) or installed with180º rotation
- Install function block turned through180º
- Safety stop button not operating – Spring defective
- Button calcified
- Clean spring and/or button, exchange if necessary