Andonstar 207S Digital Microscope User Manual
- June 12, 2024
- ANDONSTAR
Table of Contents
Andonstar 207S Digital Microscope
Safety and maintenance
- Please read this user’s manual carefully before using the device. It may cause permanent damage to the device to not follow the operation guide listed in this manual. We do not recommend using this product outdoors. It is not waterproof, and can not be placed in an extreme environment: heat, high pressure etc.. Please keep and use it in safe, clean, and dry environment. Stay it away from oil, gas, water and corrosive potions. Storage method refers to other electronic products, such as a computer.
- This product contains tiny parts and components that are NOT edible. Please let children and teens use this device under proper guidance and supervision by adults. Disabled, patients and people with allergies should not use this product.
- Clean the lens when the image goes blurry: cut the power supply firstly, wipe the lens with a soft clean cloth moistened with alcohol, and make sure the whole device is dry before powering it on again. Users should follow these steps for daily cleaning as well, remember to ONLY wipe the INSULATED part of the monitor. Please check whether the microscope has been restored to dryness before powering it on again.
- The screen of the monitor is very fragile, please use it with care. Do not drop, hard press or leave it with a sharp object. Hold the frame of the monitor to adjust its orientation. The monitor is not waterproof, please clean it with soft and dry material.
- When the product is not in use, please cut off the power supply and store it in a dry environment.
Specifications
Video resolution| UHD 2880×2160 24fps; FHD 1920×1080 60fps/30fps ; HD 1280×720
120fps
---|---
Video Format| MP4
Frame rate| Max 120fps (600 Lus illumination &HDP120)
Minimum Working Distance| 2cm
Photo resolution| Max 5600*4200 (24M) interpolation
Photo Format| JPG
Storage| Micro-SD card, up to 64G (It is recommended to format the memory card
before use.
High-quality video recording has higher requirements on the memory card, otherwise it may cause a crash, etc.)
Video-output| HDMI
PC Support| Windows PC software with measurement (gift)
Power supply| USB 5V 2A and above(If the current is too low or unstable, it is
easy to cause the host to restart. It is recommended to use a plug with a
specification of 5V and 2A or above.)
Stand size| 20cm12cm19cm
Package include| Microscope host, metal base plate, metal bracket, remote,
switch cable, HDMI cable,
USB cable, base plate screws*2, wrench
Package include
Assembly
- Screw the metal bracket on to the base (P2 ).
- After completing the above steps, if you need to adjust the direction of the beam on the column, you can loosen the column fixing ring to adjust the direction of the column. Tighten the post retaining ring clockwise when finished.
- Screw the microscope mainframe thumbscrews (P3) on the large circle of the beam outwards to leave enough space for the microscope host.
- Insert the host of the microscope into the large circle of the beam of the column.
- Adjust the position and orientation of the host, and then tighten the fixing screws of the host. Note that during this process, the microscope must not be stuck in the position of the focusing barrel. If the installation operation is correct, after installation, the focusing tube, the screen of the microscope and the angle between the column and the bottom plate can be adjusted freely. If there is any problem during installation, please contact us in time to avoid damage to the product caused by improper installation and affect normal use.
Buttons
- Power on/off
- Mode/menu
- Up/Digital zoom in
- Down/Digital zoom out
- OK/Start video record
- Picture capture
- Infrared sensor (when you are using the remote, please point the remote to this so the device would response)
- Built-in LED light adjustment pulley
- Focus controller
- Memory card slot
- USB port
- HMDI port
- Freeze: Stop the image on the display, works in video mode, photo mode and while recording.
- Digital Zoom in & Zoom out : Digital zoom up to 3x.
- Brightness+&Brightness-: Exposure compensation from +2.0 to -2.0.
- +: Cross line setting.
- Sharpness up&down: three levels of sharpness: Soft/Normal/Strong. Those two buttons are both used to switch the levels, but in different orders.
- Contrast up&down: same principle as Sharpness
- Upside down:refer to pic as follow
Quick start
Connect
To use the microscope stand alone, you need to connect the host fixed beam to
the power supply via the switch cable. See the picture(P6) below.
Switch on
Then press and hold the Power button (① P4 “Buttons”) underneath the display
until the display turns on. (It may turn on automatically while you connecting
cables at the first time, and it’s totally fine.) Troubleshooting If the
display freezes, locate the “reset ” hole on the back of the monitor. Use a
narrow object such as an unfolded paperclip to depress the button located
inside. This resets all settings to their factory values and restarts the
display. It does not erase saved images or video.If you still have questions,
please contact us in time.
Adjusting the Magnification and Focus
- Use the large knobs on the metal bracket to raise or lower the host fixed beam to the desired height. The lower the height, the greater the magnification is. But be careful not to let the bottom of the lens contact the object being imaged. (Note that you may need to reposition the spotlights as you move the beam up or down.)Turn the Focus controller(⑨ P4 “Buttons”) to focus the image.
- To increase the digital magnification, press and hold the Up button (③ P4 “Buttons” ) until the desired digital magnification(up to an additional 3x beyond the optical magnification) is reached. Use the Down (④ P4 “Buttons”) button to decrease the digital magnification.
Using a Micro SD Card to Save Photos or Videos
By using a Micro SD card (not provided), you can save photos and videos to
review later or export to a computer or other device .
Attention:
- TF card are not included in the standard package. Please purchase it from quality suppliers. We recommend 10 grade high speed TF card.
- Metal strip side of the card faces outward.
- Push the card deeply into the card slot until you hear a click sound. Otherwise it would bounce back.
- When the monitor shows “card error” or “card is full”, please format the card first before take pics. Format steps are: Press and hold button M until it shows a menu→press M button again to get into Setting menu→Press up or down button to select→choose”Format”→press OK button to confirm.
- Do not insert a card while microscope is working. If you do, the microscope would switch off automatically. And you will have to turn it on again. In order to take videos, pictures, or playback files we have taken, we need to get into different modes firstly. MODE button(② P4 ,marked as“M”)can be used to selected among three modes, video , photo and playback . In video mode, there are white numbers to the right of the mode icon, indicating the amount of time the memory card’s remaining memory is available for video recording.
Record videos
In video mode and photo mode press “OK” button to start recording. Press it
again to stop. It works the same way with the “OK” button on the remote.
Take photos
In video mode , photo mode and while the microscope is recording, press “Capture” button to take photos. The button marked as a camera on remote works the same way.
Attention:
- You cannot take pictures or videos in playback mode.
- If there is an abnormality such as a crash when switching video or photo modes, please format the memory card and reconnect the power before use. If the same problem still occurs, please replace the class10 high-speed card.
Playback & manage files
Use button “M” to get into Playback mode, press “up” or “down” to browse
files. In order to play videos, press“OK”to play it, “OK”to pause, “M” to
stop.
Settings
In any mode, press and hold M button until it shows video/photo/playback menu,
press M again, get into Setting menu. For example. In video mode, press and
hold M button, it would show video menu as below:
And then, press M again to get into setting menu,as below
Save Setting
In order to let the microscope memorize the setting changes, please turn off
the microscope by PRESSING THE POWER BUTTON ON THE MONITOR (press and hold
until it switch off). Setting changes won’t be saved if you switch off the
device in other ways.
Output to external devices
HDMI output
- firstly, make sure the external device is actual real FHD 1080P HDMI monitor, otherwise the display resolution can not reach to 1080P.
- Power on the microscope, and connect it to the HDMI monitor. The microscope has no built-in battery, so please make sure the microscope stays powered on the whole time.
- Switch on the microscope, place the specimen on the base or the slide holder, adjust the object distance and focus distance.
- When the microscope is connected to other display devices, the built-in display and other display devices can display images at the same time.
- Can take pictures and video in HDMI mode.
USB output
Software installation
Where to download the software(Please type all letters properly capitalized):
https://bit.ly/3xCRDPL Currently software“Microscope
Measure”only supports Windows system. System requires Windows XP SP3, Windows
7, Windows8, Windows10 Runtime:Microsoft.Net Framework 4.0, Microsoft Visual
C++ 2010 If there isn’t complete either of the runtime mentions above in your
computer system, it would report wrong during the installation process. If you
couldn’t open the download link above, contact our customer service. After
done downloading, open the zip file and run it.
Icons definitions
Interface Definitions and Functions
Main menu:
Where users to open different devices or import pictures to observe or edit,
do video settings or save settings, choose which windows to show or hide etc.
toolbar:
Where show tools that are used to do measuring and image analysis. Definition
and function of different tools has been given in chapter “Icons definitions”.
Users can choose to hide or show this toolbar window following path:
‘View→Toolbars and Docking Windows→Standard’.
Pictures browser:
Where users review all pictures they’ve captured. Users can also edit the
picture by right-clicking the picture and open it in the main operating
window. Choose ‘View→Toolbars and Docking Windows→Picture browser’ to show or
hide this window.
Secondary operating window:
This window is to digital zoom in the area around cursor. With help of this
window, the result of measuring can be much more precisely.
Main operating window:
This windows shows the full view from the microscope. And it is also the place
where users do measuring and image analysis.
Calibration Management and Measuring Results:
These two windows shows at the same place, users can switch them by clicking.
Operating Steps
- Material: A computer (Windows system, with software ‘Microscope Measure’); USB microscope (device name: ‘USB CAMERA’), A ruler.
- Steps
- Connect the microscope to computer via the USB cable included. After the microscope monitor displays few options, choose “USB camera”by pressing button “down”&”OK” or using remote.
- Open software“Microscope Measure”.
- Click “File”→ “Open”→ “Open Device”→ “USB MODE” → “USB CAMERA”.
Functions
- Calibration
- Put the ruler under the digital microscope, adjust the focusing tube and the height of the stand, to get the best clearance and desired magnification. (After its done, keep the object distance for the rest steps)
- In the ‘Calibration management’ set the name and unit length of the new calibration(refer the picture on the right). Then, click ‘Calibration’, meanwhile, the ‘ ‘ in the toolbar should have been chosen automatically. If no, please choose it yourselves.
- Move the cursor to the main operation window, draw a unit length line with help of the ruler(it doesn’t matter if the length result shows differently). After these, click the ‘Finish’ button in the bottom of the ‘Calibration Management’ window.
- Check. The length of the line you draw in step 3 should now appear as the unit length. The name of the new calibration should have showed in the list of calibrations.
Measuring
- Choose the tool you need to do measuring in the toolbar.
- Click dots or draw lines that you need to measure in the main operating window. 3, Place the results of measuring in a proper place around the target.
Special Effect
- Includes: Edge detection, Inverse color, Flip horizontal, Relief, Sharpen and Smooth.
- Steps:
- Choose the special effect you need in the toolbar.。
- Move your cursor to the main operating window, Left-click and hold to draw a rectangle to cover the whole target area, release your mouse, get the special effect result.
- Left-click again, end the special effect. PS: Not like another special effect, “Flip horizontal” would apply to the whole view, instead of the target rectangle.
- Capture and Recording
Capture
- Click ‘ ‘ to capture.
- The result of the capture can be reviewed and deleted in the ‘Picture browser’ window.
- Check and change the save path: “File→Save Setting→Path”.
Recording
- Choose the video resolution as 640*480 following the path “File→Video Setting→Video Capture Pin→Output size(S)”
- Click “ ”, finish the other settings and start to record.
- Once it starts to record, it would show a timer on the upper left corner.
- Check and change the save path: “File→Save Setting→Path”.
FAQ
Why it says ‘missing files’ during installation or initiator procedure?
Please confirm that in the system there are Microsoft. Net Framework 4.0 and
Microsoft Visual C++ 2010 runtime.
The software works fine, but the software can not recognize the
microscope.
Firstly, please make sure that you have connected the microscope to the PC
properly and have chosen ‘USB camera’ on the microscope monitor. Secondly, if
there is still no image, please check the ‘Device Manager’ of your PC, delete
the previous USB camera from “image devices”, then rescan device changes. Let
the system identifies again. After its done, in the ‘Imaging devices’ there
should have shown the current USB camera device name, which is “USB Camera”.
Then reboot the software.
Why there is a measurement error?
In order to get a more precise measure result, you would need a more precise
calibration. And when you apply a calibrator to measure a length, you need to
keep the magnification still, which means you need to keep the object distance
still as when you set the calibration.
The host restarts or a black screen appears during the operation?
Please check whether the power supply is sufficient and stable. You can try to
replace the power supply. It is recommended to use a 5V 2A and above
specification plug.
When viewing pictures, the picture freezes?
Because this product needs a high-quality memory card to record high- definition images and videos, please format the memory card and reconnect the power before use. If similar problems still occur, please replace the class10 high-speed card.
PS:If there are other questions or problems, please contact us as soon as possible, we will do our best to help!Thanks for your support!
Warranty
Warranty
Name:| Address:
Phone number:| Post code:| Email:
Model name:| Purchase date:
Fault details:
Date:| Fault description:
Notice:
Our warranty does not cover:
1| If the purchaser can not provide a purchase proof, or it shows the product
was bought as second hand
condition.
2| If the product has been placed or used in an improper environment, such as heat, wet, wrong power supply
environment etc.
3| If the fault caused by accident, oversight, faulty operation or natural
disasters etc.
4| If the fault caused by people who are not belong to authorized
organizations of our company during repacking, repair, dismantle, Or if users
repack, repair or dismantle the device not following our advice.
5| Out of warranty period.
References
- Your request has been blocked. This could be due to several reasons.
- Microscope Measure V3.6.1.exe - Google Drive
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>