HAKKO FX-805 Control Software Installation Guide
- October 30, 2023
- Hakko
Table of Contents
FX-805 Control Software
Installation Guide
Software
- The contents of this manual are subject to change without notice.
- The specifications of this software are subject to change without notice due to improvements.
- Reproducing or copying this document, in whole or in part, is prohibited.
Trademarks
System names, product names, and service names on this document are generally
registered trademarks or trademarks of their respective developers.
This document does not include TM, (R) marks.
Disclaimers
We will assume that, by downloading and installing this software, the customer has agreed to the following disclaimers.
- We will bear no responsibility for any claims for losses, lost earnings, or claims by third parties due to operation of this software.
- We will bear no responsibility for any problems that result through download and installation of this software.
- The company retains all property rights, ownership rights, intellectual property rights, etc. related to this software.
Installing the Software
-
Double-click the CD-ROM or the downloaded software. File name: HAKKO Control Software Setup X.X.X.X.exe
-
Select the language and click [OK].
-
After checking the License Agreement, select [I accept the agreement] and click [Next].
-
From here, follow the instructions on the screen.
-
The software will automatically launch when the installation is completed. (Figure 1-3)
-
Click [Exit] to exit the software. (Figure 1-4/1-5)
Connecting to a PC
- Connect the product to a PC with the included USB cable.
- Place the handpiece on the iron holder.
- Connect the station and the handpiece.
- Turn the station power switch ON.
- Launch the software.
NOTE If [- – -] appears on the display even after the PC is connected as shown in the right figure, turn OFF the station power switch and then turn it ON again.
HAKKO FX-805 Control Software
NOTE Do not use a USB cable that is more than two meters long.
Software Updates
Follow the instructions below to download the latest software.
-
Go to [Customer Support > support and services > login and new user registration] on the HAKKO website.
https://www.hakko.com/doc_support-e -
Log in, or create an account.
-
Click [My page (Product registration from here)] to register the product.
NOTE Product must be registered to download software. -
Click [Download of Product Data] under the menu.
-
Select [Software] under the various resource search options.
-
Input the product name as the keyword.
-
Select the language and click [Search with these conditions].
-
Click [Download] in the search results.
HEAD OFFICE
4-5, Shiokusa 2-chome, Naniwa-ku, Osaka 556-0024 JAPAN
TEL: +81-6-6561-3225 FAX: +81-6-6561-8466
https://www.hakko.com E-mail: sales@hakko.com
OVERSEAS AFFILIATES
U.S.A.: AMERICAN HAKKO PRODUCTS, INC.
TEL: (661) 294-0090 FAX: (661) 294-0096
Toll Free (800) 88-HAKKO
4 2 5 5 6
https://www.HakkoUSA.com E-mail:
Support@HakkoUSA.com
HONG KONG: HAKKO DEVELOPMENT CO., LTD.
TEL: 2811-5588 FAX: 2590-0217
https://www.hakko.com.cn E-mail:
info@hakko.com.hk
SINGAPORE: HAKKO PRODUCTS PTE., LTD.
TEL: 6748-2277 FAX: 6744-0033
https://www.hakko.com.sg E-mail:
sales@hakko.com.sg
Please access the code for overseas distributors.
https://www.hakko.com/doc_network
© 2022 HAKKO Corporation. All Rights Reserved.
Company and product names are trademarks or registered trademarks of their
respective companies.
Operation guide
FX-805 Control Software
File
Port selection
Used to manually select Port Number.
Port search
Used to autodetect port/reconnect station.
Exit
Used when exiting software.
Setting
Language: Japanese/English/Chinese
Select one of these languages.
Display temperature unit: ºC/ºF
Select the unit for temperature.
Management
File storage location:
Parameter setting file/
Automatic calibration result file/
Tip sensor temperature monitor file
Select where files are saved.
NOTE By default, files are saved in the same location as software folder.
Tip sensor temperature monitor auto save: ON/OFF
When set to [ON], the Tip sensor temperature
will be recorded constantly and saved as CSV file.
NOTE Default is OFF.
Tip sensor temperature monitor file split interval (minutes): 1 to 120
Segments CSV files into multiple files based on minutes.
NOTE Default is 5 min.
Help
Connection station version information
Shows the station firmware version.
Version information
Initial Screen
-
Station name is displayed.
The station can be named in the Parameter Setting button under the section [Station ID]. -
The tip type in use is displayed.
The tip type will update automatically based on the tip. -
The Setting Temp status is displayed.
Manual inputing temperature displays
[SET TEMP]| Preset temperature displays [PRESET] and the preset number.
---|---
This can be done through the Temperature Change button.| You can change the Setting Temp manually or by selecting one of the reset temperature buttons. -
The temperature registered for each preset number is displayed. The preset temperatures can be changed in the Parameter Setting button under [Temp Set Menu].
The preset temperature selection status is shown by the button color.
Factory default setting temperatures:
No.1: 250ºC (600ºF)
No.2: 300ºC (700ºF)
No.3: 350ºC (750ºF)
No.4: 400ºC (800ºF)
No.5: 450ºC (850ºF)
Why are some buttons unelectable?
[Preset 5 ON/OFF] is set to [OFF] under the [Temp Set Menu] of the button.
The operating status of the station is displayed.
RUNNING
Operating normally
SLEEP
Sleep state
SHUT OFF
Time specified in the Shut Off Menu has elapsed
SENSOR ERROR
Tip heating element/sensor not detected -
GRIP ERROR
Inapplicable handpiece connected or the handpiece is disconnected
NO CONNECTION
Station is turned OFF or the station is not connected to the PC
HEATERSHORT ERROR
Inapplicable tip inserted
ZEROCROSS ERROR
Power supply abnormality or the main unit is damaged
TIP DETECTION ERROR
Inapplicable tip detected -
The selected output mode is displayed. The mode can be changed in the Parameter Setting button under [Output mode setting].
-
The correction value (offset value) is displayed. The offset can be changed using the Tip Temperature Correction button or the Automatic Calibration and Recorder button. Displayed when the parameter setting change is locked.
-
This can be locked/unlocked in the Parameter Setting button under [Lock Menu].
The tip sensor temperature can be displayed on a graph.
● The graph data can be manually or automatically saved
Manually record: Pressing [Start record], pressing [Stop record] ends the recording
Recording with Auto save: files will be saved depending on the value imputed in [Tip sensor
temperature monitor file split interval (minutes)].
● Saved file name
During manual saving: FX-805TEMP_M_220101_093358.csv
During automatic saving: FX-805TEMP_220101_093358.csv
● The graph “Time axis” and “Temperature axis” settings can be changed Click button to display the Setting screen. -
Date stamp of recording: January 1, 2022, 9:33:58 Time axis default
Length of time displayed 30 seconds
Time Scale Interval 5 seconds
Temperature axis default
Maximum Temperature Displayed 500ºC/950ºF
Minimum Temperature Displayed 0ºC/0ºF
Temperature Scale Interval 50ºC/50ºF
Operation Buttons
Temperature Change
● Change the set temperature
NOTE
If the temperature is changed here, the preset temperature selection is
automatically canceled.
Tip Temperature Correction (Offset)
(See “4-3. Operation” in the Instruction Manual)
The tip temperature can be corrected with the following two methods.
NOTE This will not function when the station is in offset mode.
The tip temperature can be corrected with the following two methods.
NOTE This will not function when the station is in offset mode.
Manual input
- Measure the tip temperature
- Input the offset value
- Click the [Confirm] button
- Click the [Close] button
Using the HAKKO thermometer with the Temperature Sending Function
- Measure the tip temperature
- Send the measured temperature
- Click the [Confirm] button
- Click the [Close] button
Parameter Setting
(See “Quick Parameter Settings” in the Instruction Manual)
The current settings are highlighted in blue A and can be changed in the
column to the right B . By click the [Confirm] button the buzzer will sound,
and [Sys] or [Set] will display on the station to show the settings have been
updated.
The settings can be saved or loaded as CSV files. Click the [Save] button to
store the settings from B . Default file name: FX-805-Parameter.csv
Click the [Load] button and select CSV file to input the settings, and then
click [Confirm] to apply the settings.
- The file name is displayed in the upper left corner.
If the selected file name has an ” “…
When the B values are changed after loading, ” ” mark will be added at the end of the file name.
Example: FX-805-Parameter.csv*
Parameter No. correspondence table
Sleep Menu
ON/OFF | Parameter No.07 |
---|---|
Activation Time | Parameter No.02 |
Sleep Temp | Parameter No.13 |
Shut Off Menu
ON/OFF| Parameter No.08
Activation Time| Parameter No.18
Alarm Menu
Error Alarm| Parameter No.05
Ready Alarm| Parameter No.06
Low Temp Alarm| Parameter No.03
Lock Menu| Parameter No.14
Temp Set Menu
Preset Temp| Parameter No.23
Preset ON/OFF| Parameter No.24
Output Mode Setting| Parameter No.12
Automatic Calibration and Recorder
What is Automatic Calibration?
It is an operation to automate tip temperature management, and to save the
proper calibration results.
- Automatically saves the calibration results when the calibration is completed
References
- VisionXE
- HAKKO Corporation - We respond to soldering needs throughout the world.
- hakko.com.cn
- American Hakko Products, Inc. Home of superior quality soldering, desoldering, rework, BGA, and fume extraction systems and hand tools for the electronics manufacturing industry.
- HAKKO Corporation - We respond to soldering needs throughout the world.
- Login/Signup |HAKKO | HAKKO Corporation