BRESSER 8855600 Biolux SEL Junior Student Microscope Instruction Manual

October 30, 2023
BRESSER

BRESSER-logo

BRESSER 8855600 Biolux SEL Junior Student Microscope

www.bresser.de/P8855600000000

Product Information

Product Name: Microscope
Model Number: Art. No. 8855600, Art. No. 8855610
Brand: Bresser

Manual and Downloads
Manual Download: www.bresser.de/P8855600000000
Service and Warranty: www.bresser.de/warranty_terms

Microscope Guide: www.bresser.de/guide

Microscope FAQ: www.bresser.de/faq

All downloads: www.bresser.de/downloads

Warnings

  • Not suitable for children under three years. CHOKING HAZARD – small parts.
  • PUNCTURING HAZARD – functional sharp points!
  • LACERATING HAZARD – functional sharp edges!
  • Keep instructions and packaging as they contain important information.

Cleaning and Disposal
Clean the microscope with a cloth moistened with alcohol.
Dispose of the packaging materials in accordance with the applicable guidelines and corresponding regulations.

Product Usage Instructions

Setting up the Microscope

  1. Place the microscope on a stable surface.
  2. Insert the batteries in the battery compartment located at the bottom of the microscope.
  3. Turn on the LED lights by using the switch located near the battery compartment.
  4. To adjust the focus, use the coarse and fine focus knobs located on either side of the microscope.
  5. Adjust the objective lenses by rotating the turret until the desired magnification is achieved.
  6. Place the specimen on the stage and adjust the lighting, as needed, to view the specimen clearly.

Using the LED Light

The LED light has three brightness settings:

  • I – light from below (transmitted light)
  • II – light from above (reflected light)
  • III – both lights are on

Troubleshooting

If no image is visible, check the following:

  • Ensure that the microscope is properly set up and turned on.
  • Check that the batteries are properly inserted and have sufficient charge.
  • Adjust the focus and objective lenses to ensure that the specimen is in focus.
  • Ensure that the lighting is adjusted correctly.

Caring for the Microscope

After use, turn off the LED lights and remove the batteries.
Clean the microscope with a cloth moistened with alcohol. Store the microscope in a dry place, protected from dust and moisture.

MANUAL DOWNLOAD

www.bresser.de/P8855600000000

SERVICE AND WARRANTY:

www.bresser.de/warranty_terms

MICROSCOPE GUIDE:

www.bresser.de/guide

MICROSCOPE FAQ:

www.bresser.de/faq

EXPERIMENTS:

www.bresser.de/downloads

WARNINGS! Not suitable for children under three years. CHOKING HARZARD – small parts. PUNCTURING HAZARD – functional sharp points! LACERATING HAZARD – functional sharp edges! Keep instructions and packaging as they contain important information.

BRESSER-8855600-Biolux-SEL-Junior-Student-
Microscope-01

Operating Instructions

WARNING!
Not for children under three years. Choking hazard – small parts. Contains functional sharp edges and points!

ATTENTION: Only suitable for children of at least 8 years of age. Instructions for parents or other responsible persons are enclosed and must be followed. Keep packaging as it contains important information.

General Warnings

  • Choking hazard — This product contains small parts that could be swallowed by children. This poses a choking hazard. Risk of electric shock — This device contains electronic components that operate via a power source (batteries). Only use the device as described in the manual, otherwise you run the risk of an electric shock.
  • Risk of fire/explosion — Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire. Excessive heat or improper handling could trigger a short-circuit, a fire or an explosion.
  • Risk of chemical burn — Make sure you insert the batteries correctly. Empty or damaged batteries could cause burns if they come into contact with the skin. If necessary, wear adequate gloves for protection.
  • Leaking battery acid can lead to chemical burns. Avoid contact of battery acid with skin, eyes and mucous membranes. In the event of contact, rinse the affected region immediately with a plenty of water and seek medical attention.
  • Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. Remove the batteries from the unit if it is not to be used for a long period of time, or if the batteries are empty!
  • Never recharge normal, non-rechargeable batteries. This could lead to explosion during the charging process.
  • Rechargeable batteries are only to be charged under adult supervision.
  • Rechargeable batteries are to be removed from the toy before being charged
  • The terminals must not be short-circuited.
  • Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.
  • Tools with sharp edges are often used when working with this device. Because there is a risk of injury from such tools, store this device and all tools and accessories in a location that is out of the reach of children. Keep instructions and packaging as they contain important information.
  • The chemicals and liquids provided should be kept out of reach of children. Do not drink the chemicals! Hands should be washed thoroughly under running water after use. In case of accidental contact with the eyes or mouth rinse with water. Seek medical treatment for ailments arising from contact with the chemical substances and take the chemicals with you to the doctor.

Check the Power supply for damage to the cord, plug, enclosure or other parts on a regular basis before use. Do not use until the damage has been repaired. The toy is not intended for children under three years. The toy must only be used with the recommended power supply. The power supply is not a toy.

The toy is not to be connected to more than the recommended number of power supplies.

TIPS on cleaning

Remove the device from it’s energy source before cleaning (remove plug from socket / remove batteries).

Clean the exterior of device with a dry cloth. Do not use cleaning fluids so as to avoid causing damage to electronic components.
Toys liable to be cleaned with liquid are to be disconnected from the power supply before cleaning
Clean the lens (objective and eyepiece) only with the cloth supplied or some other soft lint-free cloth (e.g. microfiber). Do not use excessive pressure – this may scratch the lens.
DISPOSAL
Dispose of the packaging material/as legally required. Consult the local authority on the matter if necessary.

Do not dispose of electrical equipment in your ordinary refuse. The European guideline 2012/19/EU on Electronic and Electrical Equipment Waste and relevant laws applying to it require such used equipment to be separately collected and recycled in an environment-friendly manner.

Empty batteries and accumulators must be dis-posed of separately. Information on disposing of all such equipment made after 01 June 2006 can be obtained from your local authority.
In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in the normal household waste is explicitly forbidden. Please pay attention to dispose of your used batteries as required by law – at a local collection point or in the retail market (a disposal in domestic waste violates the Battery Directive).
Batteries that contain toxins are marked with a sign and a chemical symbol. „Cd“ = cadmium, „Hg“ = mercury, „Pb“ = lead.

BRESSER-8855600-Biolux-SEL-Junior-Student-
Microscope-10

  1. Battery contains cadmium
  2. Battery contains mercury
  3. Battery contains lead

EC Declaration of Conformity
Bresser GmbH has issued a „Declaration  of Conformity“ in accordance with applicable guidelines and corresponding standards. The full text of the EU declaration of conformity is available at the following internet address:
www.bresser.de/download/8855600000000/CE/8855600000000_CE.pdf

UKCA Declaration of Conformity

Bresser GmbH has issued a „Declaration of Conformity“ in accordance with applicable guidelines and corresponding standards. The full text of the UKCA declaration of conformity is available at the following internet address: www.bresser.de/download/8855600000000/UKCA/8855600000000_UKCA.pdf

Bresser UK Ltd.
Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain

Here are the parts of your microscope

  1. 10x WF Eyepiece
  2.  20x WF Eyepiece
  3. Barlow Lens
  4. Eyepiece supports
  5. Microscope Head
  6. Objective Nosepiece
  7. Objective
  8. Clips
  9. Microscope Stage
  10. LED Illumination (transmitted light)
  11. Microscope Base
  12. Selection Knob for Illumination
  13. Battery compartment
  14. Focus knob
  15. Color Filter wheel
  16. LED Illumination (reflected light)
  17. 5 Slides, 5 Cover Sips and 5 Prepared Specimens plastic box
  18. Specimens:
  19. Yeast
  20. Sea Salt
  21. Brine Shrimp Eggs (Artemia)
  22. Empty Bottle
  23. Empty Bottle
  24.  Specimen slicer
  25. Magnifier box
  26. Test tube
  27. Tweezers
  28. Dissecting needle
  29. Dissecting knife
  30. Protective cover
  31. Container
  32. Smartphone holder

How do I use my microscope?
Before you assemble your microscope, make sure that the table, desk or whatever surface that you want to place it on is stable, and does not wobble.

How do I operate the electric LED illumination?
In the base of the microscope there is a battery compartment (13). Loosen the screw at the battery compartment cover with a small Philips screwdriver and remove the cover.
Place the batteries in the compartment so that the flat minus poles (-) press against the spring terminal and the plus poles (+) are touching the flat contact sheets.
Close the battery compartment with the cover and turn the microscope around again.
The first lamp shines onto the specimen from below and the second from above. (The thing that you want to observe with the microscope is called the object or specimen, by the way.) You can use each lamp on its own, or both of them together. There is a selection knob for this (12). It has three numbers: I, II and III.

If you select the .

  1. The light only comes from below (transmitted light).
  2. The light only comes from above (reflected light).
  3. Both lamps shine light on the specimen.

For transparent objects (transmitted-light objects), number I is best. In order to observe firm, non-transparent objects (direct-light objects), select number II. For semi-transparent objects, it is best to select number III.
It is not recommended to use number III for transmitted-light objects on slides, since the light may cause reflections on the surface of the slide, which will disturb your observation.

When do I use the color filters?
The color filter wheel (15) is located below the microscope stage (9). They help you when you are observing very bright or clear specimens. Here, you can choose from various colors. This helps you better recognize the components of colorless or transparent objects (e.g. grains of starch, protozoa).

How do I adjust my microscope correctly?
Each observation starts with the lowest magnification.

Adjust the microscope

  • stage (9) so that it goes all the way down to the lowest position. Then, turn the objective nose-piece (6) until it clicks into place at the lowest  magnification (objective 4x).

Note:
Before you change the objective setting, always move the microscope stage (9) to its lowest position. This way, you can avoid causing any damage!

Now, insert the 10x eye-piece (1) into the Barlow lens (3). Make sure that the Barlow lens is placed all the way into the eyepiece supports (4) and is not pulled out.

How do I observe the specimen?
After you have assembled the microscope with the adequate illumination and adjusted it correctly, the following basic rules are to be observed:
Start with a simple observation at the lowest magnification. This way, it is easier to position the object in the middle (centering) and make the image sharp (focusing).
The higher the magnification, the more light you will require for a good image quality.

Now place the prepared specimen (17) directly under the objective on the microscope stage. The object should be located directly over the illumination (10).

In the next step, take a look through the eye-piece (1) and carefully turn the focus knob (14) until the image appears clear and sharp. Now you can select a higher magnification by slowly removing the Barlow lens (3) from the eyepiece support (4). When the Barlow lens is almost completely pulled out, the magnification can be increased to almost double.
If you would like an even higher level of magnification, insert the 20x eyepiece (2) and turn the objective nosepiece (6) to a higher setting (10x or 40x).

Important tip:
The highest magnification is not always the best for every specimen!

Note:
Each time the magnification changes (eyepiece or objective change, pulling out the Barlow lens), the image sharpness must be readjusted with the focus knob (14). When doing this, make sure to be careful. If you move the microscope stage too quickly, the objective and the slide could come into contact and become damaged!

Which light for which specimen?
With this unit, a reflected light and transmitted light microscope, you can observe transparent, semi-transparent as well as non-transparent objects.
The image of the given object of observation is “transported” through the light. As a result, only the correct light will allow you to see some-thing!
If you are observing non-transparent (opaque) objects (e.g. small animals, plant components, stones, coins, etc.) with this microscope, the light falls on the object that is being observed. From there, the light is reflected back and passes through the objective and eyepiece (where it gets magnified) into the eye. This is reflected light microscopy.

For transparent objections (e.g. protozoa), on the other hand, the light shines from below, through the opening in the microscope stage and then through the object.
The light travels further through the objective and eyepiece, where it is also magnified, and finally goes into the eye. This is transmitted-light microscopy.
Many microorganisms in water, many plan components and the smallest animal parts are already transparent in nature. Others have to be prepared. We may make them transparent through a treatment or penetration with the right materials (media), or by taking the thinnest slices from them (using our hand or a specimen slicer), and then examine them. You can read more about this in the following sections.

How do I make thin specimen slices?
Only do this with the supervision of your parents or another adult.
As I already pointed out, the thinnest slices possible are taken from an object. In order to get the best results, we need some wax or paraffin. It is best if you get a candle. Place the wax in a pot and heat it carefully over a low burner. Now, dip the object in the liquid wax a few times. Then, let the wax get hard. Using the Specimen slicer (19) or a knife/scalpel, cut the smallest slices from the object that is covered with wax. These slices are to be laid on a slide and covered with a cover slip.

How do I make my own specimens?
Take the object that you want to observe and place it on a glass slide (17). Then, add a few drops of distilled water on the object using a pipette. Now, place a cover slip vertically at the edge of the drop of water, so that the water runs along the edge of the cover slip. Then, slowly lower the cover slip over the water drops.

Experiments
Use the following web link to find interesting experiments you can try out.
How do you hatch brine shrimp? How to make salt crystals and much more.
http://www.bresser.de/downloads
Microscope accessories can be found here: http://www.bresser.de/P8859480

Troubleshooting

BRESSER-8855600-Biolux-SEL-Junior-Student-
Microscope21

Smartphone holder
Open the flexible holder and put your smart-phone in it. Close the cradle and make sure your phone is properly seated. The camera must be positioned exactly above the eyepiece. Open the locking clip on the back of the holder and fit the eyepiece view exactly onto your smart-phone camera. Now retighten the locking clip and attach the smartphone holder to the eye-piece of your microscope. Now start the cam-era app. If the image is not yet centered on your display, loosen the locking clip slightly and readjust. It may be necessary to use the zoom function to fill the image on the display. A slight shading at the edges is possible. Re-move the smartphone from the cradle after use!

NOTE:
Make sure that the smartphone cannot slip off the cradle. Bresser GmbH accepts no liability for damage caused by a dropped smartphone!
Make sure your microscope has a long service life.
Clean the lens (objective and eyepiece) only with the cloth supplied or some other soft lint-free cloth (e.g.microfibre). Do not press hard as this might scratch the lens.
Ask your parents to help if your microscope is really very dirty. The cleaning cloth should be moistened with cleaning fluid and the lens wiped clean using little pressure.
Make sure your microscope is always protected against dust and dirt. After use leave it in a warm room to dry off. Then install the dust caps and keep it in the case provided.

Warranty & Service
The regular warranty period is 2 years and begins on the day of purchase. To benefit from an extended voluntary warranty period as stated on the gift box, registration on our website is required.
You can consult the full warranty terms as well as information on extending the warranty period and details of our services at: www.bresser.de/warranty_terms.

Bresser GmbH Gutenbergstraße 2 46414 Rhede · Germany
www.bresser.de
@BresserEurope

Bresser UK Ltd.
Suite 3G, Eden House Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals