Specifications

  • Brand: SWIT
  • Model: PB-S146A
  • Voltage: 14.4V
  • Capacity: 10.1Ah
  • Energy Capacity: 146Wh

Product Usage Instructions

Charging the Battery:

  1. Use only the provided charger or a compatible charger to charge the Li-ion battery.
  2. Connect the charger to a power source and then to the battery.
  3. Allow the battery to charge fully before first use.

Installing the Battery

  1. Ensure the device is powered off before installing the battery.
  2. Insert the Li-ion battery into the designated slot in the device, following the correct polarity.
  3. Secure the battery in place according to the device’s instructions.

Operating the Device

  1. Power on the device and follow the manufacturer’s instructions for proper usage.
  2. Monitor the battery level and recharge when necessary to avoid over-discharging.
  3. Avoid exposure to extreme temperatures or moisture to prolong battery life.

FAQ

  • Q: Can I use a different charger to charge the battery?

    • A: It is recommended to use only the provided charger or a compatible charger to ensure safe and efficient charging of the Li-ion battery.
  • Q: How should I store the battery when not in use?

    • A: Store the battery in a cool, dry place away from direct sunlight and extreme temperatures. It is also advisable to store it partially charged rather than fully discharged.
  • Q: What should I do if the battery gets damaged?

    • A: If the battery shows signs of damage such as swelling or leaking, discontinue use immediately and contact the manufacturer for proper disposal and replacement.

Report No. RSZBHST2408201660

UN38.3 Test Report

  • Name of Samples: Camera Li-ion Battery
  • Applicant’s name : SWIT Electronics Co.,Ltd.

Shenzhen Beihang Testing Co., Ltd.

Test Report issued under the responsibility of

TEST REPORT UN38.3(Rev 7+AMD1)

Manual of test and criteria, Section 38.3 – Lithium metal and lithium ion Batteries


Report Number| RSZBHST2408201660
Date of issue| 2024-08-26
Testing Laboratory| Shenzhen Beihang Testing Co., Ltd.

Room 202, 2/F, Building F, HaoWei Industrial Park, QingSong West Road, PingShan District, Shenzhen, Guangdong, China

Tested by| Romy **| Seal of BUAA
Reviewed by|
Justin **
Approved by| Arvin
Applicant’s name| SWIT Electronics Co.,Ltd.
Applicant’s Address| 10 Heng Tong Road,Xin’gang Nanjing Economic and Technological Development Zone Nanjing 210038 ,P.R.China
Applicant’s Contact|

Manufacturer’s name| SWIT Electronics Co.,Ltd.
Manufacturer’s Address| 10 Heng Tong Road,Xin’gang Nanjing Economic and Technological Development Zone Nanjing 210038 ,P.R.China

Manufacturer’s Contact|

Test Standard| UNITED NATIONS “Recommendations on the TRANSPORT OF DANGEROUS GOODS Manual of Tests and Criteria” Seventh revised edition (ST/SG/AC.10/11/Rev 7+AMD1)

(ST/SG/AC.10/11/Rev 7+AMD1).

Name of Products| Camera Li-ion Battery|
Tradem| SWIT|
Model/Type| PB-S146A|
Ratings| 14.4V,10.1Ah,146Wh|

Report No. RSZBHST2408201660

SAMPLE DESCRIPTION

List of Attachments

Appendix 1: 3 pages of Photo Documentation :


Summary of testing
Ssmple description
| Sample Number| State of samples|
B1# – B8#| The conditions of the batteries of samples No. B1 # – B4# are at first cycle, in fully charged states.
The conditions of the batteries of samples No. B5# – B8# are after 25 th cycles ending, in fully charged states.
C1# – C10#| The conditions of the cells of samples No. C1# – C5# are at first cycle at 50% of the design rated capacity.
The conditions of the cells of samples No. C6# – C10# are after 25 th cycles ending at 50% of the design rated capacity.
B9# – B16#| The conditions of the batteries of samples No. B9# – B12# are at first cycle, in fully charged states.
The conditions of the batteries of samples No. B13# – B16# are after 25th cycles ending in fully charged states.
C11# – C30#| The conditions of the cells of samples No. C11# – C20# are at first cycle, in fully discharged states.
The conditions of the cells of samples No. C21# – C30# are after 25th cycles ending in fully discharged states.

Test Procedure

  1. TestsT.1 toT.5 are conducted in sequence on the same battery, Tests 6 and 8 are conducted using not otherwise tested batteries. Test T.7 may be conducted using undamaged batteries previously used in Tests T.1toT.5 for purposes of testing on cycled batteries.
  2. Inorder to quantify the mass loss, the following procedure is provided:
    Mass loss(%)=(M1-M2)/M1×100
    Where M1 is the mass before the test and M2 is the mass after the test. When mass loss does not exceed the values in Table below, it is considered as” no mass loss”.
Mass M of cell or battery Mass loss limit
M<1g 0.5%
1g≤M≤75g 0.2%
M>75g 0.1%

In test T.1toT.4, batteries meet this requirement if there is no leakage , no venting ,no disassembly ,no rupture and no fire and if the open circuit voltage of each test battery after testing is not less than 90%ofits voltage immediately prior to this procedure.

Test Conclusion
The Sample has passed the test items of UNITED NATIONS “Manual of Tests and Criteria” (ST/SG/AC.10/11/Rev.7/Amend.1/Section 38.3)

Possible test case verdicts 测试判定:

  • test case does not apply to the test object …………… : N/A
  • test object does meet the requirement ……………….. : P (Pass)
  • test object does not meet the requirement…………… : F (Fail)

Date of receipt of test item ………………… : 2024-08-10

Date (s) of performance of tests …… : 2024-08-11 to 2024-08-24

General remarks

The test results presented in this report relate only to the object tested.

This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.

Throughout this report a point is used as the decimal separator.

General product information
| Product name| Rechargeable Li-ion Cell| Camera Li-ion battery|
Type/model| NCR18650GA| PB-S146A
Nominal voltage| 3.6V| 14.4V
Rated capacity| 3450mAh| 10.1Ah
Recommended charging voltage|

4.2V

|

16.8V

Recommended charging Current|

1675mA

|

3000mA

Maximum charging current| 1675mA| 5000mA
Maximum discharging current| 10000mA| 12000mA
Discharge cut-off voltage| 2.5V| 10.9V
Dimensions

尺寸

| —| 121mm95mm62mm
Weight| —| 约873.0g
Appearance| —| Approximate Black Cuboid
Remark: The batteries consist of 12 cells.
UN38.3

Clause| Requirement + Test| Result – Remark| Verdict
38.3.4.1| Test T.1: Altitude simulation| | P
---|---|---|---
| Test cells and batteries shall be stored at a pressure of 11.6 kPa or less for at least six hours at ambient temperature (20±5°C)| | P
| Cells and batteries meet this requirement if there is no mass loss, no leakage, no venting, no disassembly, no rupture and no fire and if the open circuit voltage of each test cell or battery after testing is not less than 90% of its voltage immediately prior to this procedure. The requirement relating to voltage is not applicable to test cells and batteries at fully discharged states.| No leakage, no venting, no disassembly, no rupture and no fire. 。

The data see table 1.

|

P

38.3.4.2| Test T.2: Thermal test| | P
| Test cells and batteries are to be stored for at least six hours at a test temperature equal to 72±2°C, followed by storage for at least six hours at a test temperature equal to – 40±2°C. The maximum time interval between test temperature extremes is 30 minutes. This procedure is to be repeated 10times, after which all test cells and batteries are to be stored for 24 hours at ambient temperature (20±5°C).| | P
| For large cells and batteries the duration of exposure to the test temperature extremes should be at least 12 hours.| |

N/A

| Cells and batteries meet this requirement if there is no mass loss, no leakage, no venting, no disassembly, no rupture and no fire and if the open circuit voltage of each test cell or battery after testing is not less than 90% of its voltage immediately prior to this procedure. The requirement relating to voltage is not applicable to test cells and batteries at fully discharged states.|

  • No leakage, no venting, no disassembly, no rupture and no fire.
  • The data see table 1.

| P
UN38.3

Clause| Requirement + Test| Result – Remark| Verdict
38.3.4.3| Test T.3: Vibration| | P
---|---|---|---
| Cells and batteries are firmly secured to the platform of the vibration machine without distorting the cells in such a manner as to faithfully transmit the vibration. The vibration shall be a sinusoidal waveform with a logarithmic sweep between 7 Hz and 200 Hz and back to 7Hz traversed in 15 minutes. This cycle shall be repeated 12 times for a total of 3 hours for each of three mutually perpendicular mounting positions of the cell. One

of the directions of vibration must be perpendicular to the terminal face.

| | P
| The logarithmic frequency sweep shall differ for cells and batteries with a gross mass of not more than 12 kg (cells and small batteries), and for batteries with a gross mass of more than 12 kg (large batteries).| | P
| For cells and small batteries: from 7 Hz a peak acceleration of 1 gn is maintained until 18 Hz is reached. The amplitude is then maintained at 0.8 mm (1.6 mm total excursion) and the frequency increased until a peak acceleration of 8 gn occurs (approximately 50 Hz). A peak acceleration of 8 gn is then maintained until the frequency is increased to 200 Hz.| | P
| For large batteries: from 7 Hz to a peak acceleration of 1 gn is maintained until 18 Hz is reached. The amplitude is then maintained at 0.8 mm (1.6 mm total excursion) and the frequency increased until a peak acceleration of 2 gn occurs (approximately 25 Hz). A peak acceleration of 2 gn is then maintained until the frequency is increased

to 200 Hz. 7Hz 18Hz,0.8mm 1.6mm)

| | N/A
UN38.3

Clause| Requirement + Test| Result – Remark| Verdict
| Cells and batteries meet this requirement if there is no leakage, no venting, no disassembly, no rupture and no fire during the test and after the test and if the open circuit voltage of each test cell or battery directly after testing in its third perpendicular mounting position is not less than 90% of its voltage immediately prior to this procedure. The requirement relating to voltage is not applicable to test cells and batteries at fully discharged states.| No leakage, no venting, no disassembly, no rupture and no fire.

The data see table 1.

| P
---|---|---|---
38.3.4.4| Test T.4 : Shock| | P
| Test cells shall be secured to the testing machine by means of a rigid mount which will support all mounting surfaces of each test cell. Each cell or battery shall be subjected to a half-sine shock of peak acceleration of 150 gn and pulse duration of 6 milliseconds. Alternatively, large cells may be subjected to a half-sine shock of peak acceleration of 50 gn and pulse duration of 11 milliseconds. Each cell shall be subjected to three shocks in the positive direction followed by three shocks in the negative direction of three mutually perpendicular mounting positions of the cell or battery for a total of 18 shocks.| | N/A
| Each battery shall be subjected to a half-sine shock of peak acceleration depending on the mass of the battery. The pulse duration shall be 6 milliseconds for small batteries and 11 milliseconds for large batteries. Each cell or battery is subjected to three shocks in the positive direction followed by three shocks in the negative direction of each of three mutually perpendicular mounting positions of the cell for a total of 18 shocks. The formulas below are provided to calculate the appropriate minimum peak accelerations /| | P
UN38.3

Clause| Requirement + Test| Result – Remark| Verdict
| | | P
---|---|---|---
| Cells and batteries meet this requirement if there is no mass loss, no leakage, no venting, no disassembly, no rupture and no fire and if the open circuit voltage of each test cell or battery after testing is not less than 90% of its voltage immediately prior to this procedure. The requirement relating to voltage is not applicable to test cells and batteries at fully discharged states.| No leakage, no venting, no disassembly, no rupture and no fire.

The data see table 1.

| P
38.3.4.5| Test T.5 : External short circuit| | P
| The cell or battery to be tested shall be temperature stabilized so that its external case temperature reaches 57±4°C and then the cell or battery shall be subjected to a short circuit condition with a total external resistance of less than 0.1 ohm at 57±4°C. This short circuit condition is continued for at least one hour after the cell or battery external case temperature has returned to57±4°C.| | P
| Cells and batteries meet this requirement if their external temperature does not exceed 170 °C and there is no disassembly, no rupture and no fire during the test and within six hours after the test.| No disassembly, no rupture and no fire during the test and within six hours after the test.

The data see table 1.

| P
UN38.3

Clause| Requirement + Test| Result – Remark| Verdict
38.3.4.6| Test T.6: Impact / Crush/| | P
---|---|---|---
| Test procedure – Impact (applicable to cylindrical cells greater than or equal to18 mm in diameter)| Cylindrical cells more than 18 mm in diameter|

P

| The sample cell or component cell is to be placed on a flat smooth surface. A 15.8 mm±0.1mm diameter, at least 6 cm long, or the longest dimension of the cell, whichever is greater, Type316 stainless steel bar is to be placed across the centre of the sample. A 9.1 kg±0.1 kg mass is to be dropped from a height of 61±2.5 cm at the intersection of the bar and sample in a controlled manner using a near frictionless, vertical sliding track or channel with minimal drag on the falling mass. The vertical track or channel used to guide the falling mass shall be oriented 90 degrees from the horizontal supporting surface.| | P
| The test sample is to be impacted with its longitudinal axis parallel to the flat surface and perpendicular to the longitudinal axis of the 15.8 mm±0.1mm diameter curved surface lying across the centre of the test sample. Each sample is to be subjected to only a single impact.| | P
| Test Procedure – Crush (applicable to prismatic, pouch, coin/button cells and cylindrical cells not more than 18 mm in diameter).| Cylindrical cells not more than 18 mm in diameter / 18mm| N/A
| A cell or component cell is to be crushed between two flat surfaces. The crushing is to be gradual with a speed of approximately 1.5 cm/s at the first point of contact. The crushing is to be continued until the first of the three options below is reached.| | N/A
| (a) The applied force reaches 13 kN±0.78 kN;| | N/A
| (b) The voltage of the cell drops by at least 100 mV;| | N/A
| (c) The cell is deformed by 50% or more of its original thickness.| | N/A
UN38.3

Clause| Requirement + Test| Result – Remark| Verdict
| A prismatic or pouch cell shall be crushed by applying the force to the widest side. A button/coin cell shall be crushed by applying the force on its flat surfaces. For cylindrical cells, the crush force shall be applied perpendicular to the longitudinal axis.| | N/A
---|---|---|---
| Each test cell or component cell is to be subjected to one crush only. The test sample shall be observed for a further 6 h. The test shall be conducted using test cells or component cells that have not previously been subjected to other tests.| | N/A
| Cells and component cells meet this requirement if their external temperature does not exceed 170°C and there is no disassembly and no fire during the test and within six hours after this test.| No disassembly and no fire.

The data see table 2.

|

P

38.3.4.7| Test T.7 : Overcharge/ 过充电| | P
| The charge current shall be twice the manufacturer’s recommended maximum continuous charge current. Tests are to be conducted at ambient temperature. The duration of the test shall be 24 hours. The minimum voltage of the test shall be as follows| | P
| (a) When the manufacturer’s recommended charge voltage is not more than 18V, the minimum voltage of the test shall be the lesser of two times the maximum charge voltage of the battery or 22V.| | P
| (b) When the manufacturer’s recommended charge voltage is more than 18V, the minimum voltage of the test shall be 1.2 times the maximum charge voltage.| | N/A
| There is no disassembly and no fire during the test and within seven days after the test.| No disassembly and no fire.

The data see table 3.

| P
UN38.3

Clause| Requirement + Test| Result – Remark| Verdict
38.3.4.8| Test T.8: Forced discharge| | P
---|---|---|---
| Each cell shall be forced discharged at ambient temperature by connecting it in series with a 12V

D.C. power supply at an initial current equal to the maximum discharge current specified by the manufacturer

The specified discharge current is to be obtained by connecting a resistive load of the appropriate size and rating in series with the test cell. Each cell shall be forced discharged for a time interval (in hours) equal to its rated capacity divided by the initial test current (in ampere).

| | P
| There is no disassembly and no fire during the test and within seven days after the test| No disassembly and no fire.

The data see table 4.

| P
Table 1: T.1~T.5

Sample

No

| Mass prior to test (g)| OCV prior to test

(V)

| Test 1: Altitude simulation| Test 2: Thermal test| Test 3: Vibration| Test 4: Shock| Test 5: External Short Circuit

Mass loss

(%)

| Voltage after test/Voltage pre-test,| Mass loss

(%)

| Voltage after test/Voltage pre-test, (%)| Mass loss

(%)

| Voltage after test/Voltage pre-test, (%)| Mass loss

(%)

| Voltage after test/Voltage pre-test, (%)| Temp. (°C)
B1#| 872.338| 16.679| 0.00| 100.00| 0.01| 98.78| 0.01| 99.97| 0.01| 99.99| 57.3
B2#| 871.794| 16.686| 0.01| 99.99| 0.01| 98.74| 0.01| 99.98| 0.00| 100.00| 57.8
B3#| 871.968| 16.682| 0.00| 100.00| 0.02| 98.85| 0.01| 99.97| 0.00| 100.00| 57.5
B4#| 872.992| 16.677| 0.01| 100.00| 0.02| 98.86| 0.01| 99.98| 0.00| 100.00| 57.9
B5#| 872.537| 16.678| 0.01| 99.99| 0.01| 98.81| 0.00| 99.97| 0.00| 100.00| 57.2
B6#| 872.428| 16.683| 0.01| 100.00| 0.02| 98.79| 0.00| 99.98| 0.01| 99.99| 57.7
B7#| 872.674| 16.687| 0.01| 99.99| 0.01| 98.77| 0.01| 99.97| 0.00| 99.99| 57.4
B8#| 871.864| 16.685| 0.00| 100.00| 0.02| 98.82| 0.00| 99.99| 0.00| 100.00| 57.6
Table 2: Crush or impact

Test 6:

Impact

| Sample No.| C1#| C2#| C3#| C4#| C5#| C6#| C7#| C8#| C9#| C10#
OCV prior to test(V)| 3.697| 3.693| 3.699| 3.695| 3.693| 3.686| 3.682| 3.688| 3.685| 3.687
Temp. (°C)| 97.5| 101.3| 96.8| 99.1| 104.2| 102.3| 100.9| 98.7| 103.8| 100.1
Table 3 Overcharge

Test 7: Overcharge| Sample No.| B9#| B10#| B11#| B12#| B13#| B14#| B15#| B16#
| 16.684| 16.679| 16.682| 16.685| 16.673| 16.672| 16.673| 16.673
| OCV prior to test(V)
|
Table 4 Forced discharge

| Sample No.| C11#| C12#| C13#| C14#| C15#| C16#| C17#| C18#| C19#| C20#
|
Test 8:| OCV prior to test(V)| 2.825| 2.828| 2.831| 2.833| 2.826| 2.829| 2.828| 2.825| 2.823| 2.832
Forced discharge|
Sample No.| C21#| C22#| C23#| C24#| C25#| C26#| C27#| C28#| C29#| C30#
| | | | | | | | | |
| OCV prior to test(V)| 2.815| 2.817| 2.813| 2.816| 2.814| 2.815| 2.813| 2.816| 2.812| 2.814

Report No. RSZBHST2408201660

Appendix 1

Photo Documentation

Fig. 1 – Front view of Power Bank




Fig. 2 – Back view of Power Bank


Fig. 3 – Front view of Cell

Everbest-UN38-3-Camera-Li-ion-Battery-image \(4\)


Fig. 4 –Sample nameplate

  • Project No: ST2408201660
  • Rev.: 4.0
  • Page: 16 of 16
  • Phone : +86 755 86503482
  • Fax: +86 755 8650 3182
  • Website: http://www.hc-stc.net
  • Check: cs@hc-stc.net
  • Shenzhen Beihang Testing Co., Ltd.
  • Room 202, 2/F, Building F, HaoWei Industrial Park, QingSong West Road, PingShan District, Shenzhen, Guangdong, China/518000

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals