Wejoin SCB02 DC Variable-Frequency 3D Barrier Gate User Manual

October 30, 2023
Wejoin

Wejoin SCB02 DC Variable-Frequency 3D Barrier Gate

SCB02 (DC24V) Manual

Version: V1.0.1

Symbols Stipulations
The following symbols may appear in this manual:

Symbol Meaning
! Indicates that there is a high level of potential danger, if

not avoided, it may cause casualties or serious injuries.
!| Indicates that there is a medium or low level of potential
danger. If not avoided, it may cause minor or moderate injury to
personnel.
*| Indicates potential risks. If you ignore the information, it
may cause equipment damage, data loss, equipment performance
degradation, or unpredictable results.
?| Indicates that it can help you solve a problem or save your
time.
i| Indicates that it is additional information of the main text,
which emphasizes and supplements the main text.

Revision Records

Version No. Revision Content Release Date
V1.0.0 First Release 2022.02

Safety Instructions
The following are the correct methods of using the product:

  • To prevent danger and property damage, please read this manual carefully before using the equipment and strictly follow it during use.
  • Please keep the manual properly after reading.

Operating Environment Requirements
Please follow these requirements for the operating environment:

  • Transport, use and store the device within the allowable
    humidity and temperature range.

  • Do not let any liquid flow into the device.

  • Install the device in a well-ventilated place, and do not block
    the vents of the device.

  • Do not press hard, vibrate violently or soak the
    equipment.

  • Use the factory packaging or materials of the same quality when
    shipping the equipment.

  • It is recommended to ground via the grounding hole on the
    device to improve the reliability.

Operation and Maintenance Requirements
Please follow these requirements for operation and maintenance:

  • Do not disassemble the device privately.
  • Use the accessories or attachments of the manufacturer for installation and maintenance by professional service personnel.
  • Do not provide two or more power supply methods to the device at the same time, otherwise, the device may be damaged.
  • The self-contained boom is not allowed to be lengthened or cut off, and it is also not allowed to add weight to the boom privately.

Production Overview

The DC Variable-Frequency 3D Barrier Gate is a product designed to control access to parking lots and other restricted areas. It can be used in a variety of applications, including residential, commercial, and industrial settings.

Product Structure

Mechanism Structure
The mechanism structure of the DC Variable-Frequency 3D Barrier Gate includes a motor, a transmission mechanism, a boom, and a control system.

Running Direction Setting
The running direction of the boom can be set according to the specific requirements of the site.

Cabinet Installation

According to the specific conditions of the site, select the barrier gate of the appropriate specification, and use the expansion bolts to fix the cabinet on the ground with 4 sets M16*150 expansion bolts. At the location where the cabinet is installed, the barrier foundation should be made according to the site conditions, and the cast-in-place foundation should be made for the non- concrete ground.

Controller Explanations and Instructions
All the electrical connections are done before delivery. The necessity is to connect the power and grounding connection.

DC Variable-Frequency 3D Barrier Gate
SCB02 (DC24V) Manual
V1.0.1
I

Symbol Stipulations

Preface

The meanings of the following symbols which may appear in this manual

Symbols

Meanings

Indicates that there is a high level of potential danger, if not

avoided, it may cause casualties or serious injures.

Indicates that there is a medium or low level of potential

danger. If not avoided, it may cause minor or moderate

injury to personnel.

Indicates potential risks. If you ignore the information, it

may cause equipment damage, data loss, equipment

performance degradation, or unpredictable results.

Indicates that it can help you solve a problem or save your

time.

Indicates that it is the additional information of the main

Revision Records

text, which emphasizes and supplements the main text.

Version No.

Revision Content

Release Date

V1.0.0

First Release
Safety Instructions

2022.02

The following is the correct methods of using the product, in order to prevent danger, prevent

property damage, etc., please read this manual carefully before using the equipment and strictly

follow it during use. Please keep the manual properly after reading.
Operating Environment Requirements

Please transport, use and store the device within the allowable humidity and temperature range.

Please do not let any liquid flow into the device.

Please install the device in a well-ventilated place, and do not block the vents of the device.

Please do not press hard, vibrate violently or soak the equipment.

Please use the factory packaging or materials of the same quality when shipping the equipment.

It is recommended to ground via the grounding hole on the device to improve the reliability.
Operation and Maintenance Requirements

Please do not disassemble the device privately.

Please use the accessories or attachments of the manufacturer for installation and maintenance by

professional service personnel.

Please do not provide two or more power supply methods to the device at the same time, otherwise

the device may be damaged.

The self-contained boom is not allowed to be lengthened or cut off, and it is also not allowed to add

weight to the boom privately.

Production Overview

Functions and Features 1.1.1. Adopting the three-dimensional double-drive no- spring mechanism independently developed. 1.1.2. Dual power motors, use two- stage planetary gear and two-stage gear drive combination respectively, rotate up and down and horizontally, and superimpose to form a three-dimensional surface running track. 1.1.3. Adopting DC permanent magnet synchronous motor and variable-frequency control, effectively solve the problems of limited speed, life and spring. 1.1.4. Breaking the normal operation mode of the barrier gate, the starting point adopts the same-direction driving operation mode with the vehicle passing, to realize the ultra-high-speed and ultra- intensive operation. 1.1.5. The boom will be reset after hit and removed, which effectively protects the boom and the mechanism, alarm against abnormal lifting boom. 1.1.6. Be able to stop at any position in three-dimensional space, no longer limited height problem. 1.1.7. Double protection, one drive failure will not affect the other drive, and the barrier gate can still operate in another space; 1.1.8. No spring design, no longer worry about configuring springs and springs broken. 1.1.9. Traffic lights on the top cover to better indicate the passage of vehicles. 1.1.10. The running direction can be easily changed in two steps. 1.1.11 The cabinet is round hollow-out design, with smooth lines and intuitive movement process. 1.1.12. Equipped with carbon fiber foam round boom, to effectively protect the vehicle. 1.1.13. Large LCD screen display, English visual menu, easy function selection and debugging. 1.1.14. Support external radar, coil, infrared anti-smashing function, built- in DC 12V power output, can be used for external radar power supply. 1.1.15. Support RS485 communication or RS485 off-line connection. 1.1.16. DC12V power supply is optional.
1.2. Technical Data 1.2.1. Working temperature (motor): -35~ + 70 1.2.2. Power supply input voltage: AC110±10%, AC220V±10%
1

Controller input voltage: DC24V±10%, 10A 1.2.4. Motor power: up and down power 180W; horizontal power 60W 1.2.5. Relative Humidity: 30%~80%, No condensation 1.2.6. Distance of remote control: L30M 1.2.7. Running Speed: 0.3 seconds MAX 1.2.8. MTBF: 8,000,000 times
2. Product Structure 2.1. Mechanism Structure
2

Running Direction Setting

Cabinet Installation
According to the specific conditions of the site, select the barrier gate of the appropriate specification, and use the expansion bolts to fix the cabinet on the ground with 4 sets M16*150 expansion bolts. At the location where the cabinet is installed, the barrier foundation should be made according to the site conditions, and the cast-in-place foundation should be made for the non- concrete ground.
4. Controller Explanations and Instructions
All the electrical connections are done before delivery. The necessity is to connect the power and grounding connection.
3

4.1. Controller Interface Explanations

Item

Explanation

This interface is available for parking system, also available for

Wire Control Interface

external controller to control barrier gate. UP: Short circuit “UP” and “GND” Down: Short circuit “Down” and “GND”

Stop: Short circuit “Stop” and “GND”

4

Item

Explanation

Infrared Photocell: boom will lift up when short circuiting

“Infrared photocell interface” and “GND” during boom down.

Anti-smashing Loop Detector: boom will lift up when short circuiting “loop

Interface

detector interface” and “GND” during boom down; in up limit

position, boom will fall down automatically after these two

interfaces disconnected.

RS485

It is used for controlling the barrier gate or checking the status of

communication the barrier gate by computer or system; also used for online

interface

controlling the paired barrier gates synchronously.

Limit Relay It is used for the system to checking the status of the barrier gate

Output

by the opening and closing times; users can also change to other

Interface

output modes via option 4 of the advanced menu.

DC12V Power Output

Provide 1A current output, available for radar or small light strips.

Interface for Available to connect with R&G lights, to indicate the working

R&G lights status of the barrier gate.

The 4 buttons have two working status: normal working status

and menu setting status, the function of normal working status is

that “” is the opening function, “” is the closing function, (in

normal working status of slave motor also link-able to open and

close), “” is the stopping function, ” ” is the setting function

Buttons of which is invalid when it is short pressed under normal working

Mater Motor status; Long press ” ” for 2 seconds to enter the menu setting

status. In the menu setting status, “” and “” are used to adjust

menu items or parameters, “” is to cancel the set value or exit

the menu setting status, ” ” is used to enter the next menu or

save the set value. (Note: These buttons can only set the menu of

master motor)

5

Item

Explanation

The 4 buttons have two working status: normal working status

and menu setting status, the function of normal working status is

that “/+” is the opening function, “/-” is the closing function,

“QUIT” is the stopping function, ” ” is the setting function

Buttons of Slave Motor

which is invalid when it is short pressed under normal working status; Long press ” ” for 2 seconds to enter the menu setting status. In the menu setting status, “/+” and “/-” are used to

adjust menu items or parameters, “QUIT” is to cancel the set

value or exit the menu setting status, ”

” is used to enter the

next menu or save the set value. (Note: These buttons can only set

the menu of slave motor)

LCD Screen

It is used to display the information of the master motor of the barrier gate, such as the working status, parameters, menu items.

LED Digital It is used to display the information of the slave motor of the

Tube

barrier gate, such as the working status, parameters, menu items.

4.2. Controller Parameter Setting of Master Motor Long press “” button for 2 seconds to enter the regular menu setting status. Select menu items by short press or long press “” and “” buttons, short press once to increase or decrease by one, long press to continuously increase or decrease. When the required diameter displayed by the LCD, press ” ” button again to enter the setting of the specified item, and press the “” to return to the previous level or exit the setting. When the specified parameter setting is completed, you must press “” button to confirm it to take effect. The currently set parameters is invalid if pressing ” ” button.

The recommended range specifically refers to the 2m carbon fiber boom.

4.3. “Regular Menu” Command List of Master Motor

4.3.1. Opening operation parameters

Sub-menu

Defaults

Range

Recommended Values

1.1 Acceleration Time

3

1-20

3

Remarks
The smaller the value, the faster the speed

6

1.2 Opening Speed

100 15-100

1.3 Deceleration Angle

65

10-80

1.4 Angle of Low-speed Area

90

45-90

1.5 End Speed

8

1-50

1.6 Learning Speed

25

10-50

4.3.2. Closing operation parameters

90-100 60-70
90 6-8 25

The bigger the value, the faster the opening speed The angle at which deceleration begins in the opening process; if the boom shakes after it is opened in place, users can reduce this value. The angle at which the boom enters a low-speed area in the opening process; if the boom shakes after it is opened in place, users can reduce this value. The minimum speed at which the barrier gate is opened in place; if the boom shakes after it is opened in place, users can reduce this value. The speed at which the the barrier gate begins to learn the up limit position after the power is turned on for the first time.

7

Sub-menu

Defaults Range

2.1 Acceleration Time

1

1-20

2.2 Closing Speed

100 15-100

2.3 Deceleration Angle

35

10-80

2.4 Angle of Low-speed Area

0

0-45

2.5 End Speed

4

1-50

2.6 Learning Speed

25

10-50

Recommended Values
1-3 90-100 33-38
0
2-5
25

Remarks
The smaller the value, the faster the speed The bigger the value, the faster the opening speed The angle at which deceleration begins in the closing process; if the boom shakes after it is closed in place, users can increase this value. The angle at which the boom enters a low-speed area in the closing process; if the boom shakes after it is closed in place, users can reduce this value. The minimum speed at which the barrier gate is closed in place; if the boom shakes after it is closed in place, users can reduce this value. The speed at which the the barrier gate begins to learn the down limit position after the power is

8

turned on for the first time.

1.3 The Deceleration Angle It is used to set the angle at which deceleration begins in the opening process. The angle is 0 degree when the barrier gate is opened in place(in horizontal position) and 90 degrees when it is closed in place(in vertical position). This parameter indicates that deceleration begins when the barrier gate is opened to this angle. If the boom shakes after it is opened in place, users can reduce this value. (Chapter 2.3 has the similar operation) 1.4 The Angle of Low-speed Area It is used to set a low-speed area in the opening process. When the opening angle reaches the set angle, the barrier gate will run at the end speed that chapter 1.5 set until it is opened in place. If the value is 90, the function is invalid. If the boom shakes after it is opened in place, users can reduce this value appropriately. (Chapter 2.4 has the similar operation) 1.5 The End Speed This is the minimum speed at which the barrier gate is opened in place. The barrier gate will run at the this speed until it is opened in place. If the parameter is set too large, the boom will shake when it is opened in place. (Chapter 2.5 has the similar operation)

Quick operation parameter

Sub-menu

Model Type

Remarks

Auto setting of opening and closing SCB02 Quickly set parameters

operating parameter according to

according to different

different models

models

Notice: this device can quickly set the opening and closing operating parameters

according to the model types, which shorten the debugging time. If the effect is still

9

not good after setting, you can adjust the corresponding parameters appropriately.

4.3.4. Position setting

Sub-menu

Range

Model Type

Remarks

4.1

Find up and down Find up limit Learning mode after the

Position limit/ find up limit only

power is turned on for the

learning only/ find down limit

first time.For straight boom

mode

only

which is over 5 meters long

or fence boom, it is

recommended to select the

“Find up limit only” mode;

when the barrier gate is

installed under an eaves,

please select the “Find

down limit only” mode.

4.2

None;

operate

In manual mode, learn the

Manual according to the

up and down limit.

learning f prompts on the screen.

up and

down

Limit

4.3

None;

operate

In manual mode, learn the

Manual according to the

up limit only.

learning of prompts on the screen.

up limit

4.4

None;

operate

In manual mode, learn the

Manual according to the

down limit only.

learning of prompts on the screen.

down limit

4.5

1-3000

275-290

Boom horizontal fine

Horizontal

adjustment

fine

adjustment

4.6

1-3000

2-8

Boom vertical fine

Vertical

adjustment

fine

adjustment

10

Tip: When modifying the opening and closing indents, pay attention to observe

whether the position of the limit pressure bar and the limit adjusting bolt is sufficient,

and use a 4mm Allen wrench to adjust the position of the bolt appropriately.

4.3.5. Remote controller learning

Sub-menu

Remarks

5.1 How to match Press the setting button to enter the learning state of the remote

code

controller, and press any buttons of the remote controller to

learn. Users can learn up to 60 remote controllers

5.2 How to clear Press the Setting button to invert the color of the +- symbol on

code

the screen, and press and at the same time to clear the

code of all remote controllers.

4.3.6. RS485 setting

Sub-menu Defaults Range Remarks

When RS485 is online, the host is set

6.1 Address

1

0-255

to 0, and the slave is set to 1. When it is connected to the host computer,

1-255 can be set.

19200 baud rate is a multi-functional

6.2 Baud Rate

19200

9600/19200

communication protocol; 9600 is compatible with the protocol of old

DZ5 control board.

Notice: please contact the manufacturer for detailed communication protocol.

4.3.7. Auto-closing function

Defaults

Range

OFF 0-255, 0 is OFF

Remarks auto-closing time when no vehicle is passing. Unit:

11

second. Notice: when no loop detector or radar is installed, this function can be used for auto-closing. It can also be used with counting function to prevent the situation that the barrier gate is not closed because of over- counting.

4.3.8. Counting function

Defaults

Range

OFF

OFF-ON

Remarks store the times of opening signal, and the barrier gate will be auto closed when the number of the leaving vehicles is the same as the number of the opening signal.

4.3.9. Sensitivity of auto-reversing on obstacle

Defaults

Range Remarks

Auto-reversing response time: the bigger it is, the

100

50-400

lower the sensitivity is; the smaller it is, the higher

the sensitivity. Unit: millisecond.

4.3.10. Restore factory defaults: press the setting button to invert the color of the +symbol on the screen, and press and at the same time to restore the default values of all parameters. ——————————————————————————————————-

4.4. “Advanced Menu” Command List of Master Motor “Advanced Menu” access method: simultaneously long press the ” ” and “” button for 2 seconds to enter the menu setting status.

Advanced menu is for professional technician, general users should use it with

caution!

4.4.1. Auto-aging test

Sub-menu Defaults Range

Remarks

1.1 Time Interval OFF

0-5, 0 is Time interval for auto aging test; unit: OFF second.

1.2 Boom up angle

0

Boom up angle after switching from off to 0-90 on. If the value is odd, it will keep
switching from off to on all the time, if the

12

value is even, it will turn from off to on once and then completely turn off once again, and repeat continuously.

4.4.2. Auto-open when power off

Sub-menu Defaults Range

Remarks

The time when the voltage is lower than

2.1 Low voltage actuation time

OFF

0-5000, the set threshold and continues to exceed 0 is OFF the threshold, it will turn on automatically.

Unit: millisecond.

2.2 Low voltage threshold

21

15-23

The operating voltage is lower than the threshold; unit: V.

NoticeThis function needs to be equipped with a backup power module.

4.4.3. Motor setting Sub-menu Defaults

3.1 Power value when closing

0%

3.2 Motor type

129 Rotates Forward

Range
0-12%
129 Forward/ Reverse -CB03 Forward/ Reverse

Remarks When the spring force is not enough and the boom may sag down when the barrier gate closes at down limit position, users can increase this value appropriately to get some force. It is used for matching the motor type. This model must be set as 129 rotates forward for left-installation, 129 rotates reverse for right-installation.

4.4.4. Relay output mode The control board has two limit output relays. Users can set different output modes to meet different application requirements. Limit output: when the barrier gate opens to up limit position, the open relay will close; when the barrier gate closes to down limit position, the down limit replay will close; during the barrier gate opening or closing or stopping, these two relays are disconnected. This function can be used with the system to monitor the status of the barrier gate. Alarm for boom swinging away: in this mode, “infrared signal input” and “GND”
13

interface are used as the signal interface of boom installation. If they are short-circuited, it means that the boom works normally; if disconnected, it means that the boom swings away. When the boom swings away, the barrier gate will open to up limit position automatically and after then the up limit replay will stay in closing status. When the boom is installed correctly and work normally (the signals are short-circuited) again, the up limit replay will work normally. Notice: This function needs to be equipped with inductive switch for detecting the status of the boom. Alarm against artificial lifting boom: in this mode, the up limit relay is used as an alarm signal output. When the barrier gate closes at down limit position, if the boom is artificially lifted up to a certain angle, the up limit relay will be closed for 15 seconds as an alarm output. An external alarm can be connected for alarm. Down Limit Pulse Signal :After the boom runs to down limit position, the down limit relay will send closing signal for a second. This function can be used as the opening signal for the other barrier gate or other control system. The up limit replay was closed when boom falls down, the signal during boom falling down and boom at down limit position can be used as R&G light signal, or used for detecting the barrier gate running status.
4.4.5. Buffer time for boom from closing to opening Pressing open button in the process of closing, this parameter is used to set the buffer time of the controller from receiving the command to starting to open.
4.4.6. Buffer time of barrier gate stopping Pressing stop button in the process of barrier gate opening or closing, in order to make the barrier stop smoothly, set a buffer time. This time is the time from the barrier gate receiving the stop command to stopping completely.
4.4.7. Open the barrier gate by remote control to enter the motorcade mode Open the barrier gate by remote control to enter motorcade mode directly. At this time, the loop detector is invalid until closing the barrier gate. Closing barrier gate both by wire control and by remote control can exit the motorcade mode. Opening the barrier gate by wire control does not enter the motorcade mode. The default is “OFF”. Tip: When it is set to “OFF” in the up limit position, long press the “UP” button of the remote controller for 4 seconds can also enter the motorcade mode; or pressing “STOP” button on the controller with the program version of “10824” or above at the up limit position can also enter this mode.
14

4.4.8. Valid time of loop detector signal In the process of opening or up limit position, the duration time of the loop detector signal needs to exceed the setting time, and the auto-closing action will be executed after the loop detector signal disappears, avoiding that the loop detector signal is too short and triggers the auto-closing action to hit the vehicles. The default time is 200ms. Range: 100ms-900ms.

4.4.9. Beep of Loop detector signal There is loop detector signal (there is vehicle on the loop wire) when boom is at up limit position, the buzzer will emit a hint tone. “ON” has a sound, and “OFF” has no sound. “ON” is default.

4.4.10. Failure angle of loop detector anti-smashing During the closing process, when the boom arrives at the setting angle from the horizontal level, it will not respond to the signal of loop detector, to prevent vehicle from being followed by other vehicles, and can also prevent the misoperation of the loop detector from triggering the opening of the barrier gate. The default value is 5 degrees.

4.4.11. Failure angle on obstacle During the closing process, when the boom arrives at the setting angle from the horizontal level, if the boom meets on obstacle, it will not respond to barrier gate opening. The default value is 10 degrees.

4.4.12. Switching angle of R&G light When the boom opens to the setting angle, the relay of R&G light will close. The default value is 60 degrees.

4.4.13. Wire control signal type measurement “Infrared photocell”, “loop detector/radar” and “stop” signals of the wire control interface can be set to normal open input and normal close input, and the default is normal open input.

4.5. Controller Parameter Setting of Slave Motor

Long press ”

” button for 2 seconds to enter the regular menu setting status. The

LED digital tube will display “F-XX”. Select menu items by short press or long press

15

“/+” and “/-” buttons, short press once to increase or decrease by one, long press

to continuously increase or decrease. When the required diameter displayed by the

LED digital tube, press ”

” button again to enter the setting of the specified item,

and press the “/QUIT” to return to the previous level or exit the setting. When the

specified parameter setting is completed, you must press ” ” button to confirm it

to take effect. The currently set parameters is invalid if pressing “/QUIT” button.

4.6. “Regular Menu” Command List of Slave Motor

Menu Function

F-00

Boom Up Speed

F-01

Boom Down Speed

Boom Up

F-02 deceleration

position

Boom Down

F-03 deceleration

position

Low-speed

F-04

working angle of boom

up

Low-speed

F-05

working angle of boom

down

F-06

Boom up limit position speed

Boom down

F-07 limit position

speed

Position

F-08 adjustment of

horizontally

Defaults Range

Recommended Values

100

15-100 90-100

100

15-100 90-100

Remark
The larger the value, the faster the boom up speed The smaller the value, the faster the boom down speed

40

10-80 35-45

The angle at which the boom up starts to decelerate, unit: degree

45

10-80 40-55

The angle at which the boom down starts to decelerate, unit: degree

90

15-90 90

The angle of the last section of low-speed zone during boom up

0

0-75 0

5

1-50 4-8

2

1-50 2-6

140

1-600+ 130-140

16

The angle of the last section of low-speed zone during boom down
Boom up limit position speed
Boom down limit position speed
Adjustment horizontal position of the barrier gate

closing to limit

Swing range

F-09

adjustment of horizontally

40

opening to limit

F-10

Delay auto-close time

1

Locking time of

F-11 opening to up 5

limit

Locking time of

F-12 closing to down 0

limit

Power-on

F-13 self-learning 15

speed

F-14

Remote control learning

0

Sensitivity of

F-15 Auto-reversing 5

on obstruction

1-600+ 40-50 0-255 1 0-255 5 0-255 5 10-80 12-20 0-30 1-40 3-10

Adjustment the vertical position of the barrier gate
Auto drop off time when no car passes, unit: second Lock the gate for a period of time after opening in place, unit: second
Lock the gate for a period of time after closing in place, unit: second
Find up and down limit at this speed
Learning remote control
Obstruction response time, unit: 0.05 second

4.7. “Regular Menu” Command Explanation:

F-02 Boom up deceleration position It is used to set the starting position of deceleration in the process of boom lifting up. The unit of angle is 0 degrees when the barrier gate is in the horizontal position and 90 degrees when it is in the vertical position. This parameter indicates that the barrier will start to decelerate when the boom lifts up to this angle. If the boom shakes when lifting to up limit position, this parameter can be reduced. F-03 Boom down deceleration position It is used to set the starting position of deceleration in the process of boom falling down. The unit of angle is 0 degrees when the barrier gate is in the horizontal position and 90 degrees when it is in the vertical position. This parameter indicates that the barrier gate will start to decelerate when the boom falls down to this angle. If the boom shakes when falling to down limit position, this parameter can be increased. F-04 Low- speed running angle of boom up
17

This parameter sets a low-speed uniform speed zone during the opening process. During the boom up process, after reaching this angle set by F-04, it will run at the boom up speed set by F-06 until it is completely closed. If this parameter is set to 90, this function is invalid. If the boom shakes when lifting to up limit position, this parameter can be reduced. F-05 Low-speed running angle of boom down This parameter sets a low-speed uniform speed zone during the closing process. During the boom down process, after reaching this angle, it will run at the boom down speed set by F-07 until it is completely closed. If this parameter is set to 0, this function is invalid. If the boom shakes when falling to down limit position, this parameter can be increased. F-06 End speed of boom up The speed for boom moves to up limit. The boom will end moving at this speed when boom lifts up. If the parameter is set too large, the gate lever will shake when it is opened. F-07 End speed of boom down The speed for boom moves to down limit. The boom will end moving at this speed when boom falls down. If this parameter is set too large, the gate lever will shake when it is closed. F-08 Position adjustment of horizontally closing to limit If the position of horizontally closing to limit is deviation, this parameter can be used to fine-tune. Please see the left photo below.
F-09 Swing range adjustment of horizontally opening to limit You can fine-tune this parameter to adjust the swing range of horizontally opening to limit. Please see the right photo above. F-10 Delay auto-closing time After the barrier gate is opened, if the time set by this parameter passes and the ground sensor does not detect the passing of the vehicle, the barrier gate will automatically close. That means, the horizontal motor will swing to closing position automatically after opening to limit position. If set to 0, the barrier gate will remain
18

open until a car passes by or the close button is pressed.

F-11 Locking time of opening to up limit

After horizontally opening to limit position, it will lock the barrier motor for a period

of time according to the set value.

F-12 Locking time of closing to down limit

After horizontally closing to limit position, it will lock the barrier motor for a period

of time according to the set value.

F-13 Power-on self-learning speed

This command can set different speeds for finding the up limit and down limit. After

entering the menu, the first setting is the speed for finding the up limit. The LED

displays “1-XX”. XX means the speed for finding the up limit. The speed can be

adjusted by pressing the two buttons of “/+” and”/-“. After the up limit speed

setting is completed, press the ”

” button, the LED displays “2-XX”, and XX

indicates the speed of finding the down limit. The speed can also be adjusted by

pressing the two buttons ” /+” and ” /-“. Finally, after the up and down limit

speeds are set well, press the ”

” key to save the parameters. If you press the ”

/QUIT” key during the setting process, the set parameters are invalid.

F-14 Remote control learning

This item is used for the remote control learning of the 3-wire radio receiver of the

slave motor. It is only used when the main motor fails and the slave motor is used to

control the barrier gate. After entering the remote control learning menu item, the

number of remote controls currently learned is displayed. Long pressing and hold any

button on the remote controller for 1 second, the digital tube displays the number of

learned remote controllers plus 1. After the learning is completed, press the ”

or “/QUIT ” to exit the learning.

Note: Clear the remote controller in the H-09 item of the advanced menu.

F-15 Sensitivity of Auto-reversing on obstruction

When the barrier gate is blocked and stopped for more than the set time, the gate will

rebound and turn to open, and the LED will display the word Er.ob. The smaller the

value, the higher the sensitivity, otherwise the lower the sensitivity.

4.8. “Advanced Menu” Command List of Slave Motor “Advanced menu” access method: Simultaneously long press the ” ” and “/QUIT” button for 2 seconds to enter , the LED will display “H-XX”.
The advanced menu is used by professional technicians, and general users should use it with caution! Do not change the menu of the serial number not listed in the table at will, it may cause abnormal operation of the barrier gate.
19

Defaults Range

H-05 Motor rotation direction 2

2-3

H-09 Reset

0

H-35 H-38

Manually learn horizontal limit

no

The motor applies force

in the closing direction 1

after closing to limit

0-255 no 0-1

Remark 2: Rotation direction for left-installed. 3: Rotation direction for right-installed. 5: clear remote controller 10: reset Manually learn horizontal limit
0: On 1: Off

4.9. “Advanced Menu” Command Explanation:

H-05 Motor rotation direction

The rotation direction of horizontal motor is related to the left-installed or

right-installed of the cabinet, and the rotation direction of the motor needs to be set

correctly according to the fixed direction of the cabinet. The left-installed of the

cabinet is set to 2, the right-installed of the cabinet is set to 3.

H-09 Reset

This option has two functions, clearing the remote control and restoring factory

settings. In order to prevent misoperation, it needs to set a specific value before

pressing ”

” button to complete the operation.

5: Clear all learned remote controller of the 3-wire radio receiver of the slave motor.

10: Restore factory settings, restore the set value to the default value, and clear all the

learned remote controls at the same time.

H-35 Manually learn horizontal limit

After entering this option, the LED first displays L-00, and after the horizontal motor

of the barrier gate finds the mechanical blocking position in the open direction, the

buzzer makes a beep, the LED changes to display L-01, and the motor stops. At this

time, it is necessary to manually learn the horizontal opening to limit position and

closing to limit position. First, press and hold the “/-” button and do not release it,

move the boom holder to the closing direction until the shaft is in the required

opening position (slightly move, reserve a certain space, so that it will not hit when

the barrier gate is normally opened when it reaches the mechanical blocking point),

release the button and press the ”

” button to confirm the opening to limit

20

position. At this time, the LED displays L-02, indicating that the opening to limit

position learning is completed; continue to press and hold the “/-” button until the

boom holder is in the desired closing limit position, release the button, and press the

“button to confirm the closing limit position. After the learning is completed,

it will automatically return to the normal working state.

During the entire position learning process, if there is a deviation in the position, you

can use the ” /+” and ” /-” button to adjust. If it’s blocked by the mechanical

structure during the adjustment process and keep pressing the button, the buzzer will

beep. The device emits a continuous “beep” sound to alarm.

H-38 The motor applies force in the closing direction after closing to limit

Due to there will be more or less gaps in the mechanical assembly, during the normal

closing to limit process, the boom will swing slightly laterally, which will affect the

aesthetics. In order to avoid horizontal swing, you can turn on the horizontal motor

and then apply force in the closing direction (the force is determined by F-07, the

larger the value, the greater the force. And the value needs to be set properly, and the

boom can be closed to limit position without swinging is ok). Set the pressure of the

boom holder on the dead point of the machine core. When this function is turned on,

the F-08 can be properly adjusted to close to closing limit position to the mechanical

blocking point, and a buffer space of about 2cm can be properly reserved, so that

when the boom holder shaft closes to limit position, it leans against the blocking

point to reduce the collision sound. Proper adjustment of the F-03 deceleration

position can also reduce the collision sound. The default is 1 to enable.

5. Common Malfunctions and Solutions

Malfunction Phenomenon

Possible Causes

Solution

The swing direction of the boom does not match the actual direction

The motor rotation direction setting is wrong

Refer to 2.1 to set the rotation direction of the master and slave motors

The retraction value of Reduce the retraction value of the

The boom is the main motor 4.5 in main motor 4.5 in the closing to

automatically lifted up the closing to limit limit, or readjust the mechanical

after falls to the position is too large, or limit adjusting bolt

horizontal position

the mechanical limit

adjusting bolt in the

21

closing direction is

extended to too much

The LED digital tube of the slave motor

The slave motor sensor plug is not plugged in or the wire is loose

Check plug

the

slave

motor

sensor

displays IdLE

Slave motor failure

sensor Replace the slave motor

LED Prompt: motor sensor is not detected

The main motor sensor plug is not plugged in or the wire is loose Main motor sensor failure

Check the main motor senor plug, and plug well
Replace the main motor

The control board is The fuse is blown

Replace the fuse with the same specification

not powered on

The power supply has no Check the power supply or power

out put

circuit

Boom shakes a lot at up

Opening speed in limit position relatively large

up is

Reduce the value of 1.5 in regular menu of the main motor

limit position

Opening deceleration angle is large

Reduce the value of 1.3/1.5 in regular menu of the main motor at the same time

Boom shakes a lot

at

Closing speed in down limit position is relatively large

Reduce the value of 2.5 in regular menu of the main motor

down limit position

Closing deceleration angle is large

Reduce the value of 2.3/2.5 in regular menu of the main motor at the same time

The battery voltage of

remote controller is too Replace the batteries

low

Remote

control High-voltage wires or

distance is short

strong electromagnetic

causing

serious

interference near the

Replace the controller

high-power

remote

barrier gate

Remote

control The remote controller Contact the manufacturer

22

learning failed

does not match the

receiver

The sequence of buttons on the remote controller is incorrect

Confirm whether it is the original remote controller

The vertical motor can move, but the horizontal motor can’t move

Enter the menu state of horizontal motor (slave motor)

Exit the menu

The value of Fe-09 on

There is metal impact sound when the barrier opens to up limit position

the slave motor is too Increase the value of small, and the reserved appropriately buffer space is small The open deceleration angle of the slave motor Reduce the value of F-02

F-09

F-02 is too large

The closing deceleration

The metal impact

angle of the slave motor Increase the value of F-03

sound of horizontal

F-03 is too small

closing is too large

Boom down limit

after the barrier open to limit position

position speed of the slave motor F-07 is too

Reduce the value of F-07

large

6. Warranty and Service Items
6.1. Free service is offered for component parts in one year warranty time. (not includes the barrier boom or remote) 6.2. Lifetime service with charge accordingly. 6.3. Technical questions are supported. 6.4. The below items and situations are not included in the range of free service: 6.4.1. The user does not follow the instruction and cause any damage of the product. 6.4.2. The power supply is not stable, over the range of permitted voltage or not accordant to safety electric using standard. 6.4.3. The user installs or uses the product in wrong methods, cause damage to the appearance of product. 6.4.4. Natural disaster causes damage to the product. 6.4.5. Warranty time is over.
23

6.4.6. Service items are out of our promises.
7. Maintenance
7.1. Keep the barrier gate clean. 7.2. Check the joints every month in case of any loose parts. 7.3. Check the easily worn-out parts every half year and renew it. 7.4. Remote control distance will be shortened or not work in cases like big object screening, battery exhausting, extreme weathers.
8. Packing List

Name Screw, Nut, Plastic Cover
Expansion Screws Support Post Radio Emitter Keys
Remote Controller Manual

Specification M810 M16150

Quantity 1 4 1 1 2 2 1

Unit Application

sets Fixing the boom

sets Fixing the cabinet

pc

Optional

pcs

Optional

pcs For cabinet door

pcs

pcs

24