Wejoin SCB02 DC Variable-Frequency 3D Barrier Gate
SCB02 (DC24V) Manual
Version: V1.0.1
Symbols Stipulations
The following symbols may appear in this manual:
Symbol | Meaning |
---|---|
! | Indicates that there is a high level of potential danger, if |
not avoided, it may cause casualties or serious injuries.
!| Indicates that there is a medium or low level of potential
danger. If not avoided, it may cause minor or moderate injury to
personnel.
*| Indicates potential risks. If you ignore the information, it
may cause equipment damage, data loss, equipment performance
degradation, or unpredictable results.
?| Indicates that it can help you solve a problem or save your
time.
i| Indicates that it is additional information of the main text,
which emphasizes and supplements the main text.
Revision Records
Version No. | Revision Content | Release Date |
---|---|---|
V1.0.0 | First Release | 2022.02 |
Safety Instructions
The following are the correct methods of using the product:
- To prevent danger and property damage, please read this manual carefully before using the equipment and strictly follow it during use.
- Please keep the manual properly after reading.
Operating Environment Requirements
Please follow these requirements for the operating environment:
-
Transport, use and store the device within the allowable
humidity and temperature range. -
Do not let any liquid flow into the device.
-
Install the device in a well-ventilated place, and do not block
the vents of the device. -
Do not press hard, vibrate violently or soak the
equipment. -
Use the factory packaging or materials of the same quality when
shipping the equipment. -
It is recommended to ground via the grounding hole on the
device to improve the reliability.
Operation and Maintenance Requirements
Please follow these requirements for operation and maintenance:
- Do not disassemble the device privately.
- Use the accessories or attachments of the manufacturer for installation and maintenance by professional service personnel.
- Do not provide two or more power supply methods to the device at the same time, otherwise, the device may be damaged.
- The self-contained boom is not allowed to be lengthened or cut off, and it is also not allowed to add weight to the boom privately.
Production Overview
The DC Variable-Frequency 3D Barrier Gate is a product designed to control access to parking lots and other restricted areas. It can be used in a variety of applications, including residential, commercial, and industrial settings.
Product Structure
Mechanism Structure
The mechanism structure of the DC Variable-Frequency 3D Barrier Gate
includes a motor, a transmission mechanism, a boom, and a control system.
Running Direction Setting
The running direction of the boom can be set according to the specific
requirements of the site.
Cabinet Installation
According to the specific conditions of the site, select the barrier gate of the appropriate specification, and use the expansion bolts to fix the cabinet on the ground with 4 sets M16*150 expansion bolts. At the location where the cabinet is installed, the barrier foundation should be made according to the site conditions, and the cast-in-place foundation should be made for the non- concrete ground.
Controller Explanations and Instructions
All the electrical connections are done before delivery. The necessity is
to connect the power and grounding connection.
DC Variable-Frequency 3D Barrier Gate
SCB02 (DC24V) Manual
V1.0.1
I
Symbol Stipulations
Preface
The meanings of the following symbols which may appear in this manual
Symbols
Meanings
Indicates that there is a high level of potential danger, if not
avoided, it may cause casualties or serious injures.
Indicates that there is a medium or low level of potential
danger. If not avoided, it may cause minor or moderate
injury to personnel.
Indicates potential risks. If you ignore the information, it
may cause equipment damage, data loss, equipment
performance degradation, or unpredictable results.
Indicates that it can help you solve a problem or save your
time.
Indicates that it is the additional information of the main
Revision Records
text, which emphasizes and supplements the main text.
Version No.
Revision Content
Release Date
V1.0.0
First Release
Safety Instructions
2022.02
The following is the correct methods of using the product, in order to prevent danger, prevent
property damage, etc., please read this manual carefully before using the equipment and strictly
follow it during use. Please keep the manual properly after reading.
Operating Environment Requirements
Please transport, use and store the device within the allowable humidity and temperature range.
Please do not let any liquid flow into the device.
Please install the device in a well-ventilated place, and do not block the vents of the device.
Please do not press hard, vibrate violently or soak the equipment.
Please use the factory packaging or materials of the same quality when shipping the equipment.
It is recommended to ground via the grounding hole on the device to improve
the reliability.
Operation and Maintenance Requirements
Please do not disassemble the device privately.
Please use the accessories or attachments of the manufacturer for installation and maintenance by
professional service personnel.
Please do not provide two or more power supply methods to the device at the same time, otherwise
the device may be damaged.
The self-contained boom is not allowed to be lengthened or cut off, and it is also not allowed to add
weight to the boom privately.
Production Overview
Functions and Features 1.1.1. Adopting the three-dimensional double-drive no-
spring mechanism independently developed. 1.1.2. Dual power motors, use two-
stage planetary gear and two-stage gear drive combination respectively, rotate
up and down and horizontally, and superimpose to form a three-dimensional
surface running track. 1.1.3. Adopting DC permanent magnet synchronous motor
and variable-frequency control, effectively solve the problems of limited
speed, life and spring. 1.1.4. Breaking the normal operation mode of the
barrier gate, the starting point adopts the same-direction driving operation
mode with the vehicle passing, to realize the ultra-high-speed and ultra-
intensive operation. 1.1.5. The boom will be reset after hit and removed,
which effectively protects the boom and the mechanism, alarm against abnormal
lifting boom. 1.1.6. Be able to stop at any position in three-dimensional
space, no longer limited height problem. 1.1.7. Double protection, one drive
failure will not affect the other drive, and the barrier gate can still
operate in another space; 1.1.8. No spring design, no longer worry about
configuring springs and springs broken. 1.1.9. Traffic lights on the top cover
to better indicate the passage of vehicles. 1.1.10. The running direction can
be easily changed in two steps. 1.1.11 The cabinet is round hollow-out design,
with smooth lines and intuitive movement process. 1.1.12. Equipped with carbon
fiber foam round boom, to effectively protect the vehicle. 1.1.13. Large LCD
screen display, English visual menu, easy function selection and debugging.
1.1.14. Support external radar, coil, infrared anti-smashing function, built-
in DC 12V power output, can be used for external radar power supply. 1.1.15.
Support RS485 communication or RS485 off-line connection. 1.1.16. DC12V power
supply is optional.
1.2. Technical Data 1.2.1. Working temperature (motor): -35~ + 70 1.2.2. Power
supply input voltage: AC110±10%, AC220V±10%
1
Controller input voltage: DC24V±10%, 10A 1.2.4. Motor power: up and down power
180W; horizontal power 60W 1.2.5. Relative Humidity: 30%~80%, No condensation
1.2.6. Distance of remote control: L30M 1.2.7. Running Speed: 0.3 seconds MAX
1.2.8. MTBF: 8,000,000 times
2. Product Structure 2.1. Mechanism Structure
2
Running Direction Setting
Cabinet Installation
According to the specific conditions of the site, select the barrier gate of
the appropriate specification, and use the expansion bolts to fix the cabinet
on the ground with 4 sets M16*150 expansion bolts. At the location where the
cabinet is installed, the barrier foundation should be made according to the
site conditions, and the cast-in-place foundation should be made for the non-
concrete ground.
4. Controller Explanations and Instructions
All the electrical connections are done before delivery. The necessity is to
connect the power and grounding connection.
3
4.1. Controller Interface Explanations
Item
Explanation
This interface is available for parking system, also available for
Wire Control Interface
external controller to control barrier gate. UP: Short circuit “UP” and “GND” Down: Short circuit “Down” and “GND”
Stop: Short circuit “Stop” and “GND”
4
Item
Explanation
Infrared Photocell: boom will lift up when short circuiting
“Infrared photocell interface” and “GND” during boom down.
Anti-smashing Loop Detector: boom will lift up when short circuiting “loop
Interface
detector interface” and “GND” during boom down; in up limit
position, boom will fall down automatically after these two
interfaces disconnected.
RS485
It is used for controlling the barrier gate or checking the status of
communication the barrier gate by computer or system; also used for online
interface
controlling the paired barrier gates synchronously.
Limit Relay It is used for the system to checking the status of the barrier gate
Output
by the opening and closing times; users can also change to other
Interface
output modes via option 4 of the advanced menu.
DC12V Power Output
Provide 1A current output, available for radar or small light strips.
Interface for Available to connect with R&G lights, to indicate the working
R&G lights status of the barrier gate.
The 4 buttons have two working status: normal working status
and menu setting status, the function of normal working status is
that “” is the opening function, “” is the closing function, (in
normal working status of slave motor also link-able to open and
close), “” is the stopping function, ” ” is the setting function
Buttons of which is invalid when it is short pressed under normal working
Mater Motor status; Long press ” ” for 2 seconds to enter the menu setting
status. In the menu setting status, “” and “” are used to adjust
menu items or parameters, “” is to cancel the set value or exit
the menu setting status, ” ” is used to enter the next menu or
save the set value. (Note: These buttons can only set the menu of
master motor)
5
Item
Explanation
The 4 buttons have two working status: normal working status
and menu setting status, the function of normal working status is
that “/+” is the opening function, “/-” is the closing function,
“QUIT” is the stopping function, ” ” is the setting function
Buttons of Slave Motor
which is invalid when it is short pressed under normal working status; Long press ” ” for 2 seconds to enter the menu setting status. In the menu setting status, “/+” and “/-” are used to
adjust menu items or parameters, “QUIT” is to cancel the set
value or exit the menu setting status, ”
” is used to enter the
next menu or save the set value. (Note: These buttons can only set
the menu of slave motor)
LCD Screen
It is used to display the information of the master motor of the barrier gate, such as the working status, parameters, menu items.
LED Digital It is used to display the information of the slave motor of the
Tube
barrier gate, such as the working status, parameters, menu items.
4.2. Controller Parameter Setting of Master Motor Long press “” button for 2 seconds to enter the regular menu setting status. Select menu items by short press or long press “” and “” buttons, short press once to increase or decrease by one, long press to continuously increase or decrease. When the required diameter displayed by the LCD, press ” ” button again to enter the setting of the specified item, and press the “” to return to the previous level or exit the setting. When the specified parameter setting is completed, you must press “” button to confirm it to take effect. The currently set parameters is invalid if pressing ” ” button.
The recommended range specifically refers to the 2m carbon fiber boom.
4.3. “Regular Menu” Command List of Master Motor
4.3.1. Opening operation parameters
Sub-menu
Defaults
Range
Recommended Values
1.1 Acceleration Time
3
1-20
3
Remarks
The smaller the value, the faster the speed
6
1.2 Opening Speed
100 15-100
1.3 Deceleration Angle
65
10-80
1.4 Angle of Low-speed Area
90
45-90
1.5 End Speed
8
1-50
1.6 Learning Speed
25
10-50
4.3.2. Closing operation parameters
90-100 60-70
90 6-8 25
The bigger the value, the faster the opening speed The angle at which deceleration begins in the opening process; if the boom shakes after it is opened in place, users can reduce this value. The angle at which the boom enters a low-speed area in the opening process; if the boom shakes after it is opened in place, users can reduce this value. The minimum speed at which the barrier gate is opened in place; if the boom shakes after it is opened in place, users can reduce this value. The speed at which the the barrier gate begins to learn the up limit position after the power is turned on for the first time.
7
Sub-menu
Defaults Range
2.1 Acceleration Time
1
1-20
2.2 Closing Speed
100 15-100
2.3 Deceleration Angle
35
10-80
2.4 Angle of Low-speed Area
0
0-45
2.5 End Speed
4
1-50
2.6 Learning Speed
25
10-50
Recommended Values
1-3 90-100 33-38
0
2-5
25
Remarks
The smaller the value, the faster the speed The bigger the value, the faster
the opening speed The angle at which deceleration begins in the closing
process; if the boom shakes after it is closed in place, users can increase
this value. The angle at which the boom enters a low-speed area in the closing
process; if the boom shakes after it is closed in place, users can reduce this
value. The minimum speed at which the barrier gate is closed in place; if the
boom shakes after it is closed in place, users can reduce this value. The
speed at which the the barrier gate begins to learn the down limit position
after the power is
8
turned on for the first time.
1.3 The Deceleration Angle It is used to set the angle at which deceleration begins in the opening process. The angle is 0 degree when the barrier gate is opened in place(in horizontal position) and 90 degrees when it is closed in place(in vertical position). This parameter indicates that deceleration begins when the barrier gate is opened to this angle. If the boom shakes after it is opened in place, users can reduce this value. (Chapter 2.3 has the similar operation) 1.4 The Angle of Low-speed Area It is used to set a low-speed area in the opening process. When the opening angle reaches the set angle, the barrier gate will run at the end speed that chapter 1.5 set until it is opened in place. If the value is 90, the function is invalid. If the boom shakes after it is opened in place, users can reduce this value appropriately. (Chapter 2.4 has the similar operation) 1.5 The End Speed This is the minimum speed at which the barrier gate is opened in place. The barrier gate will run at the this speed until it is opened in place. If the parameter is set too large, the boom will shake when it is opened in place. (Chapter 2.5 has the similar operation)
Quick operation parameter
Sub-menu
Model Type
Remarks
Auto setting of opening and closing SCB02 Quickly set parameters
operating parameter according to
according to different
different models
models
Notice: this device can quickly set the opening and closing operating parameters
according to the model types, which shorten the debugging time. If the effect is still
9
not good after setting, you can adjust the corresponding parameters appropriately.
4.3.4. Position setting
Sub-menu
Range
Model Type
Remarks
4.1
Find up and down Find up limit Learning mode after the
Position limit/ find up limit only
power is turned on for the
learning only/ find down limit
first time.For straight boom
mode
only
which is over 5 meters long
or fence boom, it is
recommended to select the
“Find up limit only” mode;
when the barrier gate is
installed under an eaves,
please select the “Find
down limit only” mode.
4.2
None;
operate
In manual mode, learn the
Manual according to the
up and down limit.
learning f prompts on the screen.
up and
down
Limit
4.3
None;
operate
In manual mode, learn the
Manual according to the
up limit only.
learning of prompts on the screen.
up limit
4.4
None;
operate
In manual mode, learn the
Manual according to the
down limit only.
learning of prompts on the screen.
down limit
4.5
1-3000
275-290
Boom horizontal fine
Horizontal
adjustment
fine
adjustment
4.6
1-3000
2-8
Boom vertical fine
Vertical
adjustment
fine
adjustment
10
Tip: When modifying the opening and closing indents, pay attention to observe
whether the position of the limit pressure bar and the limit adjusting bolt is sufficient,
and use a 4mm Allen wrench to adjust the position of the bolt appropriately.
4.3.5. Remote controller learning
Sub-menu
Remarks
5.1 How to match Press the setting button to enter the learning state of the remote
code
controller, and press any buttons of the remote controller to
learn. Users can learn up to 60 remote controllers
5.2 How to clear Press the Setting button to invert the color of the +- symbol on
code
the screen, and press and at the same time to clear the
code of all remote controllers.
4.3.6. RS485 setting
Sub-menu Defaults Range Remarks
When RS485 is online, the host is set
6.1 Address
1
0-255
to 0, and the slave is set to 1. When it is connected to the host computer,
1-255 can be set.
19200 baud rate is a multi-functional
6.2 Baud Rate
19200
9600/19200
communication protocol; 9600 is compatible with the protocol of old
DZ5 control board.
Notice: please contact the manufacturer for detailed communication protocol.
4.3.7. Auto-closing function
Defaults
Range
OFF 0-255, 0 is OFF
Remarks auto-closing time when no vehicle is passing. Unit:
11
second. Notice: when no loop detector or radar is installed, this function can be used for auto-closing. It can also be used with counting function to prevent the situation that the barrier gate is not closed because of over- counting.
4.3.8. Counting function
Defaults
Range
OFF
OFF-ON
Remarks store the times of opening signal, and the barrier gate will be auto closed when the number of the leaving vehicles is the same as the number of the opening signal.
4.3.9. Sensitivity of auto-reversing on obstacle
Defaults
Range Remarks
Auto-reversing response time: the bigger it is, the
100
50-400
lower the sensitivity is; the smaller it is, the higher
the sensitivity. Unit: millisecond.
4.3.10. Restore factory defaults: press the setting button to invert the color of the +symbol on the screen, and press and at the same time to restore the default values of all parameters. ——————————————————————————————————-
4.4. “Advanced Menu” Command List of Master Motor “Advanced Menu” access method: simultaneously long press the ” ” and “” button for 2 seconds to enter the menu setting status.
Advanced menu is for professional technician, general users should use it with
caution!
4.4.1. Auto-aging test
Sub-menu Defaults Range
Remarks
1.1 Time Interval OFF
0-5, 0 is Time interval for auto aging test; unit: OFF second.
1.2 Boom up angle
0
Boom up angle after switching from off to 0-90 on. If the value is odd, it
will keep
switching from off to on all the time, if the
12
value is even, it will turn from off to on once and then completely turn off once again, and repeat continuously.
4.4.2. Auto-open when power off
Sub-menu Defaults Range
Remarks
The time when the voltage is lower than
2.1 Low voltage actuation time
OFF
0-5000, the set threshold and continues to exceed 0 is OFF the threshold, it will turn on automatically.
Unit: millisecond.
2.2 Low voltage threshold
21
15-23
The operating voltage is lower than the threshold; unit: V.
NoticeThis function needs to be equipped with a backup power module.
4.4.3. Motor setting Sub-menu Defaults
3.1 Power value when closing
0%
3.2 Motor type
129 Rotates Forward
Range
0-12%
129 Forward/ Reverse -CB03 Forward/ Reverse
Remarks When the spring force is not enough and the boom may sag down when the barrier gate closes at down limit position, users can increase this value appropriately to get some force. It is used for matching the motor type. This model must be set as 129 rotates forward for left-installation, 129 rotates reverse for right-installation.
4.4.4. Relay output mode The control board has two limit output relays. Users
can set different output modes to meet different application requirements.
Limit output: when the barrier gate opens to up limit position, the open relay
will close; when the barrier gate closes to down limit position, the down
limit replay will close; during the barrier gate opening or closing or
stopping, these two relays are disconnected. This function can be used with
the system to monitor the status of the barrier gate. Alarm for boom swinging
away: in this mode, “infrared signal input” and “GND”
13
interface are used as the signal interface of boom installation. If they are
short-circuited, it means that the boom works normally; if disconnected, it
means that the boom swings away. When the boom swings away, the barrier gate
will open to up limit position automatically and after then the up limit
replay will stay in closing status. When the boom is installed correctly and
work normally (the signals are short-circuited) again, the up limit replay
will work normally. Notice: This function needs to be equipped with inductive
switch for detecting the status of the boom. Alarm against artificial lifting
boom: in this mode, the up limit relay is used as an alarm signal output. When
the barrier gate closes at down limit position, if the boom is artificially
lifted up to a certain angle, the up limit relay will be closed for 15 seconds
as an alarm output. An external alarm can be connected for alarm. Down Limit
Pulse Signal :After the boom runs to down limit position, the down limit relay
will send closing signal for a second. This function can be used as the
opening signal for the other barrier gate or other control system. The up
limit replay was closed when boom falls down, the signal during boom falling
down and boom at down limit position can be used as R&G light signal, or used
for detecting the barrier gate running status.
4.4.5. Buffer time for boom from closing to opening Pressing open button in
the process of closing, this parameter is used to set the buffer time of the
controller from receiving the command to starting to open.
4.4.6. Buffer time of barrier gate stopping Pressing stop button in the
process of barrier gate opening or closing, in order to make the barrier stop
smoothly, set a buffer time. This time is the time from the barrier gate
receiving the stop command to stopping completely.
4.4.7. Open the barrier gate by remote control to enter the motorcade mode
Open the barrier gate by remote control to enter motorcade mode directly. At
this time, the loop detector is invalid until closing the barrier gate.
Closing barrier gate both by wire control and by remote control can exit the
motorcade mode. Opening the barrier gate by wire control does not enter the
motorcade mode. The default is “OFF”. Tip: When it is set to “OFF” in the up
limit position, long press the “UP” button of the remote controller for 4
seconds can also enter the motorcade mode; or pressing “STOP” button on the
controller with the program version of “10824” or above at the up limit
position can also enter this mode.
14
4.4.8. Valid time of loop detector signal In the process of opening or up limit position, the duration time of the loop detector signal needs to exceed the setting time, and the auto-closing action will be executed after the loop detector signal disappears, avoiding that the loop detector signal is too short and triggers the auto-closing action to hit the vehicles. The default time is 200ms. Range: 100ms-900ms.
4.4.9. Beep of Loop detector signal There is loop detector signal (there is vehicle on the loop wire) when boom is at up limit position, the buzzer will emit a hint tone. “ON” has a sound, and “OFF” has no sound. “ON” is default.
4.4.10. Failure angle of loop detector anti-smashing During the closing process, when the boom arrives at the setting angle from the horizontal level, it will not respond to the signal of loop detector, to prevent vehicle from being followed by other vehicles, and can also prevent the misoperation of the loop detector from triggering the opening of the barrier gate. The default value is 5 degrees.
4.4.11. Failure angle on obstacle During the closing process, when the boom arrives at the setting angle from the horizontal level, if the boom meets on obstacle, it will not respond to barrier gate opening. The default value is 10 degrees.
4.4.12. Switching angle of R&G light When the boom opens to the setting angle, the relay of R&G light will close. The default value is 60 degrees.
4.4.13. Wire control signal type measurement “Infrared photocell”, “loop detector/radar” and “stop” signals of the wire control interface can be set to normal open input and normal close input, and the default is normal open input.
4.5. Controller Parameter Setting of Slave Motor
Long press ”
” button for 2 seconds to enter the regular menu setting status. The
LED digital tube will display “F-XX”. Select menu items by short press or long press
15
“/+” and “/-” buttons, short press once to increase or decrease by one, long press
to continuously increase or decrease. When the required diameter displayed by the
LED digital tube, press ”
” button again to enter the setting of the specified item,
and press the “/QUIT” to return to the previous level or exit the setting. When the
specified parameter setting is completed, you must press ” ” button to confirm it
to take effect. The currently set parameters is invalid if pressing “/QUIT” button.
4.6. “Regular Menu” Command List of Slave Motor
Menu Function
F-00
Boom Up Speed
F-01
Boom Down Speed
Boom Up
F-02 deceleration
position
Boom Down
F-03 deceleration
position
Low-speed
F-04
working angle of boom
up
Low-speed
F-05
working angle of boom
down
F-06
Boom up limit position speed
Boom down
F-07 limit position
speed
Position
F-08 adjustment of
horizontally
Defaults Range
Recommended Values
100
15-100 90-100
100
15-100 90-100
Remark
The larger the value, the faster the boom up speed The smaller the value, the
faster the boom down speed
40
10-80 35-45
The angle at which the boom up starts to decelerate, unit: degree
45
10-80 40-55
The angle at which the boom down starts to decelerate, unit: degree
90
15-90 90
The angle of the last section of low-speed zone during boom up
0
0-75 0
5
1-50 4-8
2
1-50 2-6
140
1-600+ 130-140
16
The angle of the last section of low-speed zone during boom down
Boom up limit position speed
Boom down limit position speed
Adjustment horizontal position of the barrier gate
closing to limit
Swing range
F-09
adjustment of horizontally
40
opening to limit
F-10
Delay auto-close time
1
Locking time of
F-11 opening to up 5
limit
Locking time of
F-12 closing to down 0
limit
Power-on
F-13 self-learning 15
speed
F-14
Remote control learning
0
Sensitivity of
F-15 Auto-reversing 5
on obstruction
1-600+ 40-50 0-255 1 0-255 5 0-255 5 10-80 12-20 0-30 1-40 3-10
Adjustment the vertical position of the barrier gate
Auto drop off time when no car passes, unit: second Lock the gate for a period
of time after opening in place, unit: second
Lock the gate for a period of time after closing in place, unit: second
Find up and down limit at this speed
Learning remote control
Obstruction response time, unit: 0.05 second
4.7. “Regular Menu” Command Explanation:
F-02 Boom up deceleration position It is used to set the starting position of
deceleration in the process of boom lifting up. The unit of angle is 0 degrees
when the barrier gate is in the horizontal position and 90 degrees when it is
in the vertical position. This parameter indicates that the barrier will start
to decelerate when the boom lifts up to this angle. If the boom shakes when
lifting to up limit position, this parameter can be reduced. F-03 Boom down
deceleration position It is used to set the starting position of deceleration
in the process of boom falling down. The unit of angle is 0 degrees when the
barrier gate is in the horizontal position and 90 degrees when it is in the
vertical position. This parameter indicates that the barrier gate will start
to decelerate when the boom falls down to this angle. If the boom shakes when
falling to down limit position, this parameter can be increased. F-04 Low-
speed running angle of boom up
17
This parameter sets a low-speed uniform speed zone during the opening process.
During the boom up process, after reaching this angle set by F-04, it will run
at the boom up speed set by F-06 until it is completely closed. If this
parameter is set to 90, this function is invalid. If the boom shakes when
lifting to up limit position, this parameter can be reduced. F-05 Low-speed
running angle of boom down This parameter sets a low-speed uniform speed zone
during the closing process. During the boom down process, after reaching this
angle, it will run at the boom down speed set by F-07 until it is completely
closed. If this parameter is set to 0, this function is invalid. If the boom
shakes when falling to down limit position, this parameter can be increased.
F-06 End speed of boom up The speed for boom moves to up limit. The boom will
end moving at this speed when boom lifts up. If the parameter is set too
large, the gate lever will shake when it is opened. F-07 End speed of boom
down The speed for boom moves to down limit. The boom will end moving at this
speed when boom falls down. If this parameter is set too large, the gate lever
will shake when it is closed. F-08 Position adjustment of horizontally closing
to limit If the position of horizontally closing to limit is deviation, this
parameter can be used to fine-tune. Please see the left photo below.
F-09 Swing range adjustment of horizontally opening to limit You can fine-tune
this parameter to adjust the swing range of horizontally opening to limit.
Please see the right photo above. F-10 Delay auto-closing time After the
barrier gate is opened, if the time set by this parameter passes and the
ground sensor does not detect the passing of the vehicle, the barrier gate
will automatically close. That means, the horizontal motor will swing to
closing position automatically after opening to limit position. If set to 0,
the barrier gate will remain
18
open until a car passes by or the close button is pressed.
F-11 Locking time of opening to up limit
After horizontally opening to limit position, it will lock the barrier motor for a period
of time according to the set value.
F-12 Locking time of closing to down limit
After horizontally closing to limit position, it will lock the barrier motor for a period
of time according to the set value.
F-13 Power-on self-learning speed
This command can set different speeds for finding the up limit and down limit. After
entering the menu, the first setting is the speed for finding the up limit. The LED
displays “1-XX”. XX means the speed for finding the up limit. The speed can be
adjusted by pressing the two buttons of “/+” and”/-“. After the up limit speed
setting is completed, press the ”
” button, the LED displays “2-XX”, and XX
indicates the speed of finding the down limit. The speed can also be adjusted by
pressing the two buttons ” /+” and ” /-“. Finally, after the up and down limit
speeds are set well, press the ”
” key to save the parameters. If you press the ”
/QUIT” key during the setting process, the set parameters are invalid.
F-14 Remote control learning
This item is used for the remote control learning of the 3-wire radio receiver of the
slave motor. It is only used when the main motor fails and the slave motor is used to
control the barrier gate. After entering the remote control learning menu item, the
number of remote controls currently learned is displayed. Long pressing and hold any
button on the remote controller for 1 second, the digital tube displays the number of
learned remote controllers plus 1. After the learning is completed, press the ”
”
or “/QUIT ” to exit the learning.
Note: Clear the remote controller in the H-09 item of the advanced menu.
F-15 Sensitivity of Auto-reversing on obstruction
When the barrier gate is blocked and stopped for more than the set time, the gate will
rebound and turn to open, and the LED will display the word Er.ob. The smaller the
value, the higher the sensitivity, otherwise the lower the sensitivity.
4.8. “Advanced Menu” Command List of Slave Motor “Advanced menu” access
method: Simultaneously long press the ” ” and “/QUIT” button for 2 seconds to
enter , the LED will display “H-XX”.
The advanced menu is used by professional technicians, and general users
should use it with caution! Do not change the menu of the serial number not
listed in the table at will, it may cause abnormal operation of the barrier
gate.
19
Menu Function
Defaults Range
H-05 Motor rotation direction 2
2-3
H-09 Reset
0
H-35 H-38
Manually learn horizontal limit
no
The motor applies force
in the closing direction 1
after closing to limit
0-255 no 0-1
Remark 2: Rotation direction for left-installed. 3: Rotation direction for
right-installed. 5: clear remote controller 10: reset Manually learn
horizontal limit
0: On 1: Off
4.9. “Advanced Menu” Command Explanation:
H-05 Motor rotation direction
The rotation direction of horizontal motor is related to the left-installed or
right-installed of the cabinet, and the rotation direction of the motor needs to be set
correctly according to the fixed direction of the cabinet. The left-installed of the
cabinet is set to 2, the right-installed of the cabinet is set to 3.
H-09 Reset
This option has two functions, clearing the remote control and restoring factory
settings. In order to prevent misoperation, it needs to set a specific value before
pressing ”
” button to complete the operation.
5: Clear all learned remote controller of the 3-wire radio receiver of the slave motor.
10: Restore factory settings, restore the set value to the default value, and clear all the
learned remote controls at the same time.
H-35 Manually learn horizontal limit
After entering this option, the LED first displays L-00, and after the horizontal motor
of the barrier gate finds the mechanical blocking position in the open direction, the
buzzer makes a beep, the LED changes to display L-01, and the motor stops. At this
time, it is necessary to manually learn the horizontal opening to limit position and
closing to limit position. First, press and hold the “/-” button and do not release it,
move the boom holder to the closing direction until the shaft is in the required
opening position (slightly move, reserve a certain space, so that it will not hit when
the barrier gate is normally opened when it reaches the mechanical blocking point),
release the button and press the ”
” button to confirm the opening to limit
20
position. At this time, the LED displays L-02, indicating that the opening to limit
position learning is completed; continue to press and hold the “/-” button until the
boom holder is in the desired closing limit position, release the button, and press the
”
“button to confirm the closing limit position. After the learning is completed,
it will automatically return to the normal working state.
During the entire position learning process, if there is a deviation in the position, you
can use the ” /+” and ” /-” button to adjust. If it’s blocked by the mechanical
structure during the adjustment process and keep pressing the button, the buzzer will
beep. The device emits a continuous “beep” sound to alarm.
H-38 The motor applies force in the closing direction after closing to limit
Due to there will be more or less gaps in the mechanical assembly, during the normal
closing to limit process, the boom will swing slightly laterally, which will affect the
aesthetics. In order to avoid horizontal swing, you can turn on the horizontal motor
and then apply force in the closing direction (the force is determined by F-07, the
larger the value, the greater the force. And the value needs to be set properly, and the
boom can be closed to limit position without swinging is ok). Set the pressure of the
boom holder on the dead point of the machine core. When this function is turned on,
the F-08 can be properly adjusted to close to closing limit position to the mechanical
blocking point, and a buffer space of about 2cm can be properly reserved, so that
when the boom holder shaft closes to limit position, it leans against the blocking
point to reduce the collision sound. Proper adjustment of the F-03 deceleration
position can also reduce the collision sound. The default is 1 to enable.
5. Common Malfunctions and Solutions
Malfunction Phenomenon
Possible Causes
Solution
The swing direction of the boom does not match the actual direction
The motor rotation direction setting is wrong
Refer to 2.1 to set the rotation direction of the master and slave motors
The retraction value of Reduce the retraction value of the
The boom is the main motor 4.5 in main motor 4.5 in the closing to
automatically lifted up the closing to limit limit, or readjust the mechanical
after falls to the position is too large, or limit adjusting bolt
horizontal position
the mechanical limit
adjusting bolt in the
21
closing direction is
extended to too much
The LED digital tube of the slave motor
The slave motor sensor plug is not plugged in or the wire is loose
Check plug
the
slave
motor
sensor
displays IdLE
Slave motor failure
sensor Replace the slave motor
LED Prompt: motor sensor is not detected
The main motor sensor plug is not plugged in or the wire is loose Main motor sensor failure
Check the main motor senor plug, and plug well
Replace the main motor
The control board is The fuse is blown
Replace the fuse with the same specification
not powered on
The power supply has no Check the power supply or power
out put
circuit
Boom shakes a lot at up
Opening speed in limit position relatively large
up is
Reduce the value of 1.5 in regular menu of the main motor
limit position
Opening deceleration angle is large
Reduce the value of 1.3/1.5 in regular menu of the main motor at the same time
Boom shakes a lot
at
Closing speed in down limit position is relatively large
Reduce the value of 2.5 in regular menu of the main motor
down limit position
Closing deceleration angle is large
Reduce the value of 2.3/2.5 in regular menu of the main motor at the same time
The battery voltage of
remote controller is too Replace the batteries
low
Remote
control High-voltage wires or
distance is short
strong electromagnetic
causing
serious
interference near the
Replace the controller
high-power
remote
barrier gate
Remote
control The remote controller Contact the manufacturer
22
learning failed
does not match the
receiver
The sequence of buttons on the remote controller is incorrect
Confirm whether it is the original remote controller
The vertical motor can move, but the horizontal motor can’t move
Enter the menu state of horizontal motor (slave motor)
Exit the menu
The value of Fe-09 on
There is metal impact sound when the barrier opens to up limit position
the slave motor is too Increase the value of small, and the reserved appropriately buffer space is small The open deceleration angle of the slave motor Reduce the value of F-02
F-09
F-02 is too large
The closing deceleration
The metal impact
angle of the slave motor Increase the value of F-03
sound of horizontal
F-03 is too small
closing is too large
Boom down limit
after the barrier open to limit position
position speed of the slave motor F-07 is too
Reduce the value of F-07
large
6. Warranty and Service Items
6.1. Free service is offered for component parts in one year warranty time.
(not includes the barrier boom or remote) 6.2. Lifetime service with charge
accordingly. 6.3. Technical questions are supported. 6.4. The below items and
situations are not included in the range of free service: 6.4.1. The user does
not follow the instruction and cause any damage of the product. 6.4.2. The
power supply is not stable, over the range of permitted voltage or not
accordant to safety electric using standard. 6.4.3. The user installs or uses
the product in wrong methods, cause damage to the appearance of product.
6.4.4. Natural disaster causes damage to the product. 6.4.5. Warranty time is
over.
23
6.4.6. Service items are out of our promises.
7. Maintenance
7.1. Keep the barrier gate clean. 7.2. Check the joints every month in case of
any loose parts. 7.3. Check the easily worn-out parts every half year and
renew it. 7.4. Remote control distance will be shortened or not work in cases
like big object screening, battery exhausting, extreme weathers.
8. Packing List
Name Screw, Nut, Plastic Cover
Expansion Screws Support Post Radio Emitter Keys
Remote Controller Manual
Specification M810 M16150
Quantity 1 4 1 1 2 2 1
Unit Application
sets Fixing the boom
sets Fixing the cabinet
pc
Optional
pcs
Optional
pcs For cabinet door
pcs
pcs
24