Z-Ai Hour ZAH-SENSOR-02N Smart Sensor Instruction Manual
- October 30, 2023
- Z-Ai Hour
Table of Contents
Z-Ai Hour ZAH-SENSOR-02N Smart Sensor
Product Information
- Brand : Z-Ai Hour
- Product Name : Smart Sensor
- Model : ZAH-SENSOR-02N
- Battery indicator
- Signal indicator
- Ambient temperature & humidity sensor
- Light sensor
- Power switch
- Soil sensing probe
- Technical Parameters:
- Complies with Part 15 of the FCC Rules
- Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- Announcements:
- Do not bend or break the antenna, or place the device in an iron container.
- Keep the device in an open environment; otherwise, the device may fail to connect to the server.
- Put the device in a dry environment to prevent water vapor from affecting the circuit boards inside the device.
Product Usage Instructions
- Locate the power switch on the side of the device and press it once to turn on the power. The red indicator light will turn on, indicating that the power is connected. To turn off the power, press the power switch again.
- After turning on the power, the device will automatically connect to the server. The network indicator will flash blue light. If the indicator continues to flash for 4-5 seconds, it means the network is successfully connected. If the indicator continues to flash for more than 5 seconds, consider placing the device in an open place and then restarting the device to try to access the network.
- When the power supply is connected, the battery indicator will display red. If the device is fully charged, the battery indicator will turn green.
- Insert the soil sensing probe into the soil.
- Search for the subscription of Z-Ai Hour on WeChat, and select the corresponding program from the subscription to check the information data.
Operation Manual
- Brand : Z-Ai Hour
- Product Name :Smart Sensor
- Model: ZAH-SENSOR-02N
overview
Technical Parameters
- Temperature measurement range : -40~125℃; Accuracy: ± 0.3 ℃.
- Humidity measurement range : 0~100%RH; Accuracy: ± 3% RH.
- Illumination measurement range : 0~60000Lux; Accuracy: less than 1Lux.
- Carbon dioxide concentration measurement range : 400~60000ppm; Accuracy: 1 ppm.
- Soil temperature measurement range : 0~80℃; Accuracy: ± 0.5 ℃
- Soil moisture measurement range: 0~100%RH; Accuracy: ± 3% RH
- Soil pH value measurement range: 3~10; Accuracy: ± 0.5
- Soil Ec value measurement range : 0~10000us/cm; Accuracy: ±5%
- The remotely controlled output terminal can connect to a maximum of 750W AC or 150W DC
- Support connections with different types of sensors and communication modules; Interface expansion: UART, SPI, I2C, RS485
- Protection grade : IP65; Waterproof plastic shell; Size: 133mm×69mm×50mm
- Operating temperature : -10~60℃
- Transmission power : 23dBm; Antenna interface: 50 ohm/SMA-K
- Transmit frequency band: 433MHz / 800MHz / 900MHz
- Input charging voltage : DC12V; Power interface: DC005; Operating current: 30mA
Announcements
- Do not bend or break the antenna, or place the device in an iron container. Keep the device in an open environment; otherwise, the device may fail to connect to the server.
- Put the device in a dry environment to prevent water vapor from affecting the circuit boards inside the device.
Instructions
- Power switch is on the side of the device. Press it once to turn on the power. If the red indicator lights up, indicating that the power is connected. Press it again to turn off the power.
- After the power is turned on, the device will be connected automatically to the server, and the network indicator will flash bluelight. It will stop after the indicator continues to flash for 4-5 seconds, indicating that network is successfully connected. If the indicator continues to flash for more than 5 seconds, that meansthe network connection fails. Consider placing the device in an open place and then restarting the device to try to access the network.
- When power supply is connected, the battery indicator is red. If the device is fully charged, the battery indicator will turn to green.
- Insert the soil sensing probe into the soil.
- Search the subscription of “Z-Ai Hour” on WeChat, and select the corresponding program from the subscription to check the information data.
FCC Requirement
changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.