HUMIDEX HCS-BSF-HDEX Crawlspace Combo with Booster Fan Owner’s Manual
- October 30, 2023
- HUMIDEX
Table of Contents
HUMIDEX HCS-BSF-HDEX Crawlspace Combo with Booster Fan
Service and Warranty
For Customer Assistance
To aid in answering questions if you call for service or warranty purposes,
please record below the model and serial number located on the side of the
unit.
Product Name:
Model #:
Date of Manufacturing:
Date of Purchase:
Serial #:
Dealer Name (If Any):
Please Note the above information before contacting us.
For the Following Inquiries
- Service
- Parts
- Accessories
- Additional Customer Information
- Please contact us by:
- Phone: 1-888-533-1348
- Email: support@clairitech.com.
- Website: www.humidex.com.
IMPORTANT
To properly validate your warranty, you must fill out and return the warranty
card as soon as possible. If your unit is not registered, proof of purchase
will be necessary should it require any services. You can also register your
warranty online at http://www.clairitech.com/register.
Consumer Limited Warranty
ClairiTech Innovations Inc. warrants to the first consumer that this product,
when shipped in its original container, will be free from defective
workmanship and materials, and agrees that it will, at its discretion, either
repair the defect or replace the defective Product or part thereof with a new
or remanufactured equivalent at no charge to the purchaser for the period(s)
set forth below. The defective part must be returned to the manufacturer
ClairiTech Innovations Inc. All transportation charges are the sole
responsibility of the purchaser. This warranty does not apply to any
appearance items of the product nor to the additional excluded item(s) set
forth below of which have been damaged, defaced, subjected to improper
voltage, abnormal service or handling, or which has been altered or modified
in design or construction. In order to enforce the rights under this limited
warranty, the purchaser must fill out and return the warranty card as soon as
possible. If your unit is not registered, proof of purchase will be necessary
should it require any services. Neither the sales personnel of the seller nor
any other person is authorized to make any warranties other than those
described herein or to extend the duration of any warranties beyond the time
period described herein on behalf of ClairiTech Innovations Inc. The
warranties described herein shall be the sole and exclusive warranties granted
by ClairiTech and shall be the sole and exclusive remedy available to the
purchaser. Correction of defects, in the manner and for the period of time
described herein, shall constitute complete fulfillment of all liabilities and
responsibilities of ClairiTech to the purchaser with respect to the Product
and shall constitute full satisfaction of all claims, whether based on
contract, negligence, and strict liability or otherwise. In no event shall
ClairiTech be liable, or in any way responsible, for any damages or defects in
the Product which were caused by repairs or attempted repairs performed by
anyone other than an authorized servicer, unless approved by ClairiTech in
writing. Nor shall ClairiTech be liable or in any way responsible for any
incidental or consequential economic or property damage.
Warranty Period for this product:| Five (5) years on parts and electrical from
the date of purchase, two (2) years on all electronic components
---|---
Additional Items Excluded from Warranty Coverage (If Any):| Appearance items
of the product, Exterior vent, and any printed material.
Where to obtain service:| From the Manufacturer. (Refer to Page 2)
This warranty is non-transferable and applies to residential use only.
To obtain supply, accessory or product information, contact us. Refer to Page
2 for Contact Information.
Pre-Installation
Included Components
Before installing your Humidex, make sure that you have the right model and
accessories. The following items should be included in the accessory box. If
parts are missing, contact our customer service at 1-888-533-1348.
1x Owner’s Manual | 6x #8 x 9/16” Screws |
---|---|
1x Warranty Card | 4x #8 x 2” Screws |
1x Universal Boot | 4x #8 x 1¼” Truss Screws |
4Ft. 6” Insulated Flex | 2x 4” x 12” Toe Space Grill |
2x Cable Ties | 4x Plastic Anchors |
1x Green connector | 1x White Wire (50 ft.) |
Additional grilles for replenishment air and interior rooms are not included.
Tools Required for Installation
- Electric reciprocal or hole saw
- Phillips or Robinson Screw Driver
- Measuring Tape
- Hammer
- Pencil
Key Installation Facts
- To minimize noise propagation, install at least 6 ft. of 6 in. insulated flex between the universal duct boot (connected to the floor register) and the HCS-BSF.
- To further decrease noise propagation, 6 ft. of insulated flex can be used on the exhaust side of the unit. (Not Included)
- Install the unit as far away as possible from the HCS exhaust system. If this cannot be done, please use 6 in. Flex to pipe the HCS-BSF away from the exhaust system.
- If the building codes in your area require a backdraft damper to be installed, it must be placed on the exhaust side of the booster fan to limit the impact on the total airflow through the unit. (Not Included)
- This unit is typically sold with an HCS exhaust system. If this is the case, then the HCS-BSF system is made to replace your Replenishment vent required by the HCS exhaust system.
Typical Installation Diagram
Preparing the Humidex for Installation
To allow the booster fan to draw air from the upper levels, a universal boot must be installed. First, locate a safe place to cut out a hole to fit the universal boot. Once a safe and adequate area had been found, proceed by cutting the hole.
With the hole cut, install the universal booth which will allow the unit to
pull the air down.
Now that the boot has been installed, the HCS-BSF can be mounted on a floor
joist a minimum of 6 ft. away from the universal boot to reduce noise. Connect
the universal boot to the booster fan with the 6 in. insulated flex provided.
If the building codes in your area require a backdraft damper to be installed,
it must be placed on the exhaust side of the HCS-BSF to limit the impact on
the total airflow through the unit.
Note : A T-junction duct and flex can be added to the exhaust side of the HCS-BSF to direct air into all areas of the crawl space
Now that the booster fan has been installed, it must be connected to the rest of the system. To do so, a wire must be run from the booster to either the main exhaust or the control unit.
Note: These steps must be completed before plugging in the booster fan.
After the white wire has been run it must be connected to the system. Make sure the main HCS exhaust unit is unplugged before connecting the booster fan.
If the booster is connected to the main exhaust, remove the green connector, strip the wire, and connect it following the wiring guide. Reconnect the green connector once the wire has been inserted.
If the wire was run to the control, remove the bottom screw and open the control. Strip the wire and add it to the internal connector following the wiring guide. Once done, close the control.
Wiring Guide:
Yellow Wire – B Green Wire – A Black Wire – GND Red Wire – VCC
Note: The main exhaust unit must remain unplugged till the booster fan installation is complete.
On the booster fan end of the wire attach the green connector with the wiring matching the wiring guide above
|
---|---
Now that the connecter has been wired, insert it into the Booster fan unit.
| ****
Now that the booster fan has been installed and connected to the main exhaust
unit, the HCS-BSF can be plugged into any 115V outlet. With the BSF plugged
in, the main exhaust unit can be plugged in.
Note: A grounded extension cord with a maximum length of 10 feet may be used if necessary.
Specifications
Technical Data
Model| Amps (A)| Watts (W)| Airflow (CFM)| Capacity
(Sq.Ft.)
---|---|---|---|---
HCS-BSF-HDEX| 0.30| 34| 230| 2,400
Dimensions
Model | Height (In.) | Width (In.) | Depth (In.) |
---|---|---|---|
HCS-BSF-HDEX | 10.75” | 11.5” | 8.5” |
- A 24 Inch extension section is available if extra height is required.
Return and Exchange Policy
Clairitech Innovations Inc. values its relationship with you and offers you the option to return most products you purchase directly from Clairitech Innovations Inc., as set forth in detail below.
The policy Return period of 30 days for unused products and accessories:
Unless you have a separate agreement with Clairitech Innovations Inc., or
subject to the provisions below, all equipment and accessories that have not
been used, in new condition and in their original packaging may be returned to
Clairitech Innovations Inc. within 30 days of the date of purchase for a
refund of their purchase price, an equivalent credit note or the exchange of
the product, less shipping and handling charges, resupply fee and applicable
taxes, if already paid.
The return period of 15 days for defective or damaged products and
accessories:
Requests for refund and/or exchange for defective or damaged merchandise can
be made within 15 days of receipt of the merchandise. After 15 days, the
manufacturer’s warranty applies.
Note: Any product returned to Clairitech Innovations Inc. without the prior
permission of Clairitech Innovations Inc. will be considered an unauthorized
return; the customer will not receive any refunds or credit notes for the
product and Clairitech Innovations Inc. will not return the product to the
customer. Damaged products and accessories: If you have received damaged
items, please contact us by phone or email before destroying or discarding the
product and/or packaging. Failure to comply could see your request denied.
Fees
Unless the product is defective or the return is a direct result of a
Clairitech Innovations Inc., the refund or credit does not include any
shipping and handling charges shown on your packing slip or invoice; you are
responsible for those and for any damages incurred during the return shipment.
Procedure
-
Before returning a product, you must first obtain a Return Authorization Number from Clairitech Innovations Inc. Customer Service before the end of the applicable return period. Proof of purchase will also be required.
To contact Clairitech Innovations Inc. Customer Service, please call 1-888-533-1348 or Email Us
Any product returned to Clairitech Innovations Inc. without the prior approval of Clairitech Innovations Inc. will be considered an unauthorized return; the customer will not receive any credit or refund for the product and Clairitech Innovations Inc. will not return the product to the customer. -
Pack the product in its original package
-
Insert all the documents received concerning the order to be returned. Remember to keep a copy of all the documents provided.
-
To obtain a full refund, the products must be returned in perfect condition, in their original packaging, and with all documents, parts, and accessories.
-
The return costs must be prepaid; we will not accept deliveries paid at the reception.
-
For your protection, we advise you to provide the shipping service
-
Five days after the date of issue of the return authorization number Clairitech Innovations Inc. Customer Service, you must send the product to the following address:
- ClairiTech Innovations Inc.
- 1095 ch. Ohio Service Rd
- Boudreau Ouest, New Brunswick
- E4P 6N4 – Canada
-
Upon receipt of your authorized and compliant return, Clairitech Innovations Inc will issue a credit or refund equal to the purchase price paid, less shipping and handling charges, restocking charges and applicable taxes subject to this policy.
-
For assistance please call 1-888-533-1348 or Email Us
-
For any questions regarding warranty terms please call 1-888-533-1348 or Email Us NO RETURNS ARE POSSIBLE AFTER 30 DAYS FOLLOWING THE DATE OF THE BILLING DATE. CLAIRITECH INNOVATIONS SHALL NOT BE LIABLE FOR, OR ANY CHARGE OF, A CONSUMER ORDER ERROR.
References
- clairitech.com/register
- Humidity control and ventilation System - Humidex
- Humidity control and ventilation System - Humidex
Read User Manual Online (PDF format)