Wisilica Cyrus F User Guide

June 4, 2024
WISILICA

Cyrus F

Cyrus F is a versatile sensor uniquely blending motion, and ambient light together with dual channel dimming. This compact in-fixture controller has a 12-24V DC input voltage range. The device can be configured in wireless mode and UART mode. Device firmware can be updated using OTA (Over-the-Air) after installation.

Features

  • Motion, and ambient light sensing
  • 0-10V dual channel class-2 dimming output for intensity and CCT control
  • Compact form factor
  • BLE 5.2 is based on non-flooding intelligent communication
  • Zero downtime Over-the-Air (OTA) firmware updates
  • Supports UART

Specifications

Electrical Symbol Min. Typ. Max. Unit Remarks
Input Voltage Vin 12 24 Vdc Rated input Voltage
Input Current In 22*1 60*2 mA @12 Vdc

1 When used as a BLE sensor
2 When used as sensor and dual channel controller
Output Channel| Symbol| Min.| Typ.| Max.| Unit| Remarks
---|---|---|---|---|---|---
Output channel 1| CH1| 0| | 10| V| Max output tolerance ±2%
Output channel 2| CH2| 0| | 10| V| Max output tolerance ±2%
Output Current| | | | 15| mA| 0-10V sink, For dimming max output
Dimming Range| | 0| | 100| %|
Dimming Resolution| | | 7| | bit| 1000 steps
Dimming Curve| | | Linear| | |
Programming interface| Smartphone Application| Android/iOS
Additional Control Interface| CART| Light/Motion
Bluetooth| Min.| Typ.| Max.| Unit| Remarks
---|---|---|---|---|---
Frequency Range| 2402| | 2480| MHz|
TX Power| 6| 8| | dBm| Conductive
TX current| | | 48| mA| Total current@ Max Tx power
Rx Current| | | 37| mA| Total Current @Rx Mode
Receiver Sensitivity| | -95| | dBm|
Environmental| Symbol| Min.| Typ.| Max.| Unit| Remarks
---|---|---|---|---|---|---
Ambient Temperature| ta| -20| | 50| ºC|
Storage Temperature| ts| -20| | 70| ºC|
Case Temperature| tc| | 47.6| | ºC|
Relative Humidity| RH| | | 85| %|
IP Rating| | | IP20| | | Indoor use only
Mechanical| Min.| Typ.| Max.| Unit| Remarks
---|---|---|---|---|---
Dimensions| | 29.5×36| | mm| Diameter x Height
Dimensions| | 1.161×1.417| | in| Diameter x Height
Net Weight| | 90| | g| In gram
Net Weight| | 3.17| | oz| In ounce

Sensor Specifications

PIR sensor Min. Typ. Max. Unit Remarks
Mounting Height 2.4 2.8 3.0 m
Detection Range 4.0 m @3.0 m mounting height
Color sensor Min. Typ. Max. Unit Remarks
--- --- --- --- --- ---
Dynamic Illuminance Accuracy 10 1000 lux
Default Range Setting 19 512 lux User programmable
Illuminance Accuracy ±5 %
Color Accuracy ±5 %

Device Dimensions

All dimensions are in mm  Case Material: V0 PC plastic

Wisilica Cyrus F - Fig

Wire Description

Wisilica Cyrus F - Wire Description

PIN SYMBOL COLOR DESCRIPTION
1 VDC Red 12-24Vdc for sensor power
2 Ground Black GND
3 CH1+ 0-10V Yellow Intensity
4 CH2+ 0-10V Green CCT
5 TX White UART communication
6 RX Blue UART communication

Sensor Characteristics

PIR sensor characteristics

Presence Detection Coverage

Wisilica Cyrus F - Wire Description1

Color sensor characteristics

Photodiode Spectral Responsivity| Normalized Responsivity vs Angular Displacement
---|---
Wisilica Cyrus F - Spectral| Wisilica Cyrus F -
Angular

Wiring Diagram

1. Configuring Cyrus F in a light fixture for motion & daylight sensing, dimming, and tuning control
1a) Powering the Cyrus F via 12VDC auxiliary output from a driver

Wisilica Cyrus F - Wiring Diagram

1b) Powering the Cyrus F via powerpack

Set the output channel mode of the Cyrus F as a ‘single channel’ in the mobile application
Design Options

Wisilica Cyrus F - Wiring Diagram1

Installation

Create a hole of diameter 25mm (0.98in) on the fixture

Wisilica Cyrus F - fixture

Gently insert the device into the hole

Wisilica Cyrus F - Gently

The press fit mounting clip on the device will keep it attached to the fixture

Wisilica Cyrus F - mounting clip

Warning

  1. To prevent the device from any defect, please handle and store it with care.
  2. Do not store in very humid locations or at extreme temperatures.
  3. Do not open or disassemble the product.
  4. Observe the correct polarity of the output terminal
  5. Avoid input voltage exceeding the maximum rating, which will cause damage to the circuit and result in malfunction.
  6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

Ordering Information

Product Code| Product Name| Communication| Voltage Rating| Sensor| Output Channel| CART
---|---|---|---|---|---|---
WXD2CPLFN| Motion & light sensor with dual channel dimming| BLE5.2| 12-24V DC| Motion & light sensor| 0-10V (2 channels)| Yes

Compatible Devices

FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the  user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
    Caution: Any changes or Modi? cations to this device not explicitly approved by the manufacturer could void your authority to operate this equipment.
    This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

RF Exposure Information
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.

    CONNECTING THINGS TO LIFE
WiSilica Inc 23282 Mill Creek Dr #340, Laguna Hills, CA 92653
United States of America
info@wisilica.com www.wisilica.com
Version 1.0

www.wisilica.com
sales@wisilica.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals