ThermoWorkd Thermapen ONE Blue Bluetooth Temperature Probe Instruction Manual

June 16, 2024
ThermoWorkd

ThermoWorkd Thermapen ONE Blue Bluetooth Temperature Probe

SPECIFICATIONS

  • Range: –58 to 572°F (–49.9 to 299.9°C)
  • Resolution: 0.1
  • Accuracy: ±0.5°F (±0.3°C) from –4 to 248°F otherwise ±1.8°F
  • Response Time: Full reading in 1 second* (0.2 seconds per time constant)
  • Battery: 1 x AAA, approx. 500 hours without backlight
  • Auto-Off: After 10 min. to save battery life (Adjustable in-app)
  • Probe: 0.12 dia. x 4.3 L inches (reduces to 0.06 dia. inches) High-performance type K thermocouple
  • Water: IP67
  • Resistance Display: 1 H x 1.54 W inches (25 H x 39 W mm) rotates 180°, intelligent backlight
  • Dimensions: 6.1 W x 1.7 H x 0.74 D inches (48.2 W x 156.2 H x 19.3 D mm)
  • Weight: 4.05 oz. (115 g)
  • Calibration: NIST-Traceable Certificate included
  • Wireless Comm: BLE 5.0
  • Approvals: US, Canada, EU, AU/NZ

Operating Instructions

  • The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by ThermoWorks is under license.
  • Google Play and the Google Play logo are trademarks of Google Inc. Android is a trademark of Google Inc.
  • Apple, the Apple logo, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries.
  • iOS is a trademark or registered trademark of Cisco in the U.S. and other countries and is used under license.

INSTRUMENT OPERATION

  • The instrument is switched on by unfolding the probe and turned off by folding the probe away and lightly pressing the tip into the rubber probe retainer.
  • The probe should not be rotated more than 180 degrees as damage will occur. It is recommended to store the probe in the closed position, when not in use.

ThermoWorkd-Thermapen-ONE-Blue-Bluetooth-Temperature-Probe-
fig-1

  • Apply the tip of the probe to the substance, medium or surface to be measured. The sensor is located at the tip of the probe, therefore the minimum depth insertion should be 1/8-inch (3 mm).
  • The probe tip is very sharp and therefore caution should be taken when using it. Care should also be taken when closing the probe after taking hot temperatures as the probe may remain hot.

SETTINGS
Adjustable via the app and include: °C or °F, Measurement Interval, Display Sleep Interval, Connection Status Display, Display mode, Autooff Interval, Sensor Name and High/ Low Alarm levels. All settings are stored in the instrument and are downloaded to the app on connection.

DISPLAY

The display has two modes, basic mode and enhanced mode. The basic mode will be shown when not connected to Bluetooth. Enhanced mode will be shown when connected and enabled via settings.

ThermoWorkd-Thermapen-ONE-Blue-Bluetooth-Temperature-Probe-
fig-2

Please Note
Enhanced display mode, Sleep Interval, and Connection Status Display Settings are only available when using software compatible with the latest SDK/Protocol. When using the unit with older software, the display will remain in Basic mode at all times.

ROTATIONAL DISPLAY
The display will rotate 180° depending on the direction the instrument is pointing so that it can be used in either hand.

INTELLIGENT BACKLIGHT
Features a light sensor that will automatically turn the backlight on in low light conditions. The backlight will remain on for 10 seconds and automatically turn off if no movement is detected.

AUTO-OFF
If the instrument is not connected to Bluetooth within the set auto-off interval, it will shut down. The timer is reset with any movement or button press.

DISPLAY SLEEP INTERVAL
The display will ‘SLEEP’ after a settable time (default 30 seconds) when no movement has been detected. The instrument will remain connected whilst in display sleep and will wake up when movement is detected.

INSTRUMENT CLEANING – Clean the entire probe shaft with a probe wipe after each use to prevent bacteria growth. Clean the instrument body with a damp, soapy cloth and dry thoroughly. (NOTE: cleaning wipes and solvents containing Isopropyl Alcohol (IPA) may cause damage to the instrument enclosure and display screen, and will void the warranty)

BATTERY REPLACEMENT
A battery symbol ‘ ’ indicates that the batteries will need replacing. The instrument continues to measure accurately but we recommend that the batteries be changed as soon as possible.
To replace the battery, loosen the battery cover screw using a phillips screwdriver to remove the battery cover. Replace with a single AAA battery noting the polarity. Tighten the battery cover screw until the battery cover is snug onto the seal. Do not over-tighten.

ThermoWorkd-Thermapen-ONE-Blue-Bluetooth-Temperature-Probe-
fig-5

AMBIENT
The ambient operating range is –4 to 122°F.

LCD ERROR MESSAGES
If the ambient temperature falls outside the operational range, then either ‘Ambient Lo’ or ‘Ambient Hi’ will be displayed. This will continue until the ambient temperature has returned within the limits. The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room temperature. ‘Hi’ or ‘Lo’ will be displayed when the temperature being measured is outside of the instrument’s measurement range. ‘Err’ will be displayed if the instrument has developed a fault.

PRODUCT WARRANTY

This instrument carries a two-year guarantee against defects in either components or workmanship. During this period, products that prove to be defective will, at the discretion of ThermoWorks, be either repaired or replaced without charge. This guarantee does not apply to sensors/probes, where six months is offered. Full details of liability are available within ThermoWorks Terms & Conditions of Sale at www.thermoworks.com/productwarranty. For warranty, service, and technical assistance, please contact ThermoWorks’ Technical Support at 385-330-0591 or email techsupport@thermoworks.com.

CONNECTION

  • Use a Bluetooth Low Energy iOS or Android™ host device with a compatible app installed to make connections to the instrument.
  • When connected, the Bluetooth symbol will show in the display.

Please Note
No readings are stored in the instrument. When not connected, the instrument can still be used. Readings are taken and displayed every 1 second.
TRANSFER BUTTON MEASURE/TRANSFER
When connected, press to measure and transfer the result via Bluetooth.

FCC STATEMENT

RADIO CERTIFICATIONS
This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

CONTACT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>