mintie PureAir Blaster Negative Air Machine Instruction Manual
- October 30, 2023
- mintie
Table of Contents
mintie PureAir Blaster Negative Air Machine Instruction Manual
Pre-filters
PureAir Blaster – 600CFM
The PureAir Blaster is a portable multi-use air filtration machine for commercial and industrial use. Machine comes with Dustlok Primary/Secondary MERV 8 filter and a choice of final filter, HEPA 99.97% or Geo95 MERV 14 filter. Optional pleated MERV 11 dust filter and OdorGuard carbon filter for odors and fumes can be added at any time. The PureAir Blaster provides a cleaner and healthier environment at construction and renovation projects and in industrial environments.
Requirements for safe operation
- Only properly trained personnel should operate this equipment – read manual.
- Check power cord for damage or breaks.
- Do not lay power cords in water or expose to heat or sharp edges. Replace cord when damaged.
- Never clean or repair the unit while connected to power outlet.
- CAUTION:
- Do not use in hazardous atmosphere.
- Do not use to exhaust combustible or explosive gases.
- Do not expose to water or rain. · Connect only to grounded outlets with GFCI device.
- Disconnect power when cleaning and servicing.
Electrical Requirements:
- Power requirements, 115 VAC, 50/60 Hz
- Extension cords should be UL/CSA listed, 3 wire, 15 Amp rating. Cords should not exceed 50 feet in length.
- The power outlet should be 3-prong, grounded electrical outlet.
Filtration Stages
The PureAir Blaster has a multistage pre-filter located in the door compartment and HEPA or Geo95 filter mounted inside the main body.
- Primary/secondary filters are combined in dual density poly pad filter with MERV 8 efficiency. Filter is treated with antimicrobial additive and tackifier to increase dust holding capacity. Very efficient and economical filter for all types of applications.
- HEPA filter – Individually tested and certified for efficiency 99.97% of 0.3 micron size particulates.
- Optional filter: OdorGuard 600 activated carbon filter for removal of odors, gases and VOC vapor. This 2″ deep carbon filter contains 600 grams of granular carbon per square foot which is 12 times the amount of carbon in a typical carbon pleated filter.
- Optional filter: MERV 11 pleated filter 2″ deep – High efficiency filtration for 1 to 20 micron size particulates.
- Optional filter: Geo95 MERV 14 filter – Can be used in place of HEPA filter on non-hazardous applications.
Operation
- With the speed controller in the OFF position, plug the power cord into a 115 VAC power source.
- Turn the speed control knob from the OFF to the MAX position and allow the motor to come up to full speed. The POWER indicator light will come on at this time.
- Adjust the speed control to produce the desired air flow.
- When the CHANGE FILTER light comes on during operation, it indicates that the air flow is restricted. See the Troubleshooting section of this manual to correct the problem.
Troubleshooting
The PureAire Blaster has been engineered to provide reliable long lasting service. High quality materials and components are used in the manufacturing process, but there may be an instance where you need to refer to these common sense guides.
-
Unit does not start when turned `ON’.
Make sure the power cord is not damaged and that it is plugged into a power source.
If the circuit breaker on the machine has tripped, re-set it.
If the GFCI on the machine has tripped, re-set it.
If the motor smells hot it is possible that the thermal overload on the motor has tripped. Wait 30 minutes to allow the motor to cool and restart. -
Building circuit breaker has tripped.
The circuit may be overloaded. Unplug other equipment using the same circuit or reposition the machine to a different circuit. -
“CHANGE FILTER” indicator light is on.
If the Primary/Secondary filter looks dirty, replace it.
The HEPA filter may be “full” and needs to be replaced. Visually inspect the
HEPA filter and if it looks clogged then replace the filter. If the filter
does not look clogged then inspect the flex hose on the intake side of the
machine if you are using one. If the flex hose is kinked or curved too
abruptly then straighten it out and see if that corrects the problem. If you
are using another optional filter then inspect that filter to make sure you
have removed whatever packing material it may have been shipped in.
If the light remains illuminated and you have checked the hoses and replaced
the primary/secondary filter then the final stage filter, whether it is the
HEPA or Geo95 must be replaced at this time.
Proper handling of equipment will keep it in operating condition for a long
time. Please protect your investment wisely.
Specifications
Air flow: 200 to 600 cfm with variable speed controller, 1,000 cfm free flow.
Power requirements: 115 VAC/50-60 Hz, 2.2 Amp.
Controls: Speed Controller, Circuit Breaker 12 Amp, Power and Change Filter
indicator lights.
GFCI Protected Outlets: Use for additional small machines and equipment.
Maximum load is 8 amps at 115 VAC.
HEPA Filter: 99.97% @ 0.3 micron efficiency, individually tested and
certified, 16″x16″x6″, high flow.
Primary/Secondary filter: Polyester, MERV 8, dual density with antimicrobial
inhibitor and tackifier.
Blower: Motorized impeller with thermal overload.
Housing: Polyethylene flame retardant resin with UL94-V rating, UV resistant
Class 8, Protomold seamless construction.
Dimensions: 25″ L x 18½” H x 18″ W with 10″ diameter connections for flex
hoses on suction and discharge side.
Weight with filters installed: 36 lbs.
Warning: To prevent injury, always disconnect the machine from power outlet when servicing. Motor/blower will automatically restart after thermal overload or momentary loss of power.
HEPA Air Filtration Equipment
Negative Air Machines (NAM)
MiniForce II – compact, light weight machine, 2-speeds: 350 and 425 cfm.
Weight: 40 lbs. Size: 14″Hx14″Wx26.5″L Accessories: Activated carbon filter
for toxic fumes and odors; UV-C Germicidal Light for viruses, bacteria, mold
and odors.
PureAir Blaster – Rotomold, light weight, variable speed control, 200 – 600 cfm. Weight 36 lbs. Size: 19″Hx18″Wx25″L Accessories: Activated carbon filter for toxic fumes and odors; MERV 11 Pleated Filter; Geo95 for non-hazardous applications.
Mintie 600V – compact, variable speed control, 150 – 600 cfm. Weight: 55 lbs.
Size: 16″Hx14″Wx30.5″L Accessories: Activated carbon filter for toxic fumes
and odors; UV-C Germicidal Light for viruses, bacteria, mold and odors.
Mintie 1000V – compact, versatile, variable speed control, 300 – 950 cfm.
Weight: 75 lbs. Size: 21″Hx18″Wx32″L Accessories: Activated carbon filter for
toxic fumes and odors; UV-C Germicidal Light for viruses, bacteria, mold and
odors.
Mintie 2000V – variable speed control, 300 – 1900 cfm. Weight: 110 lbs. Size: 30″Hx20″Wx33″L Accessories: Activated carbon filter for toxic fumes and odors; UV-C Germicidal Light for viruses, bacteria, mold and odors.
323-225-4111
1114 San Fernando Rd., Los Angeles, CA 90065
www.mintie.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>