Simon S100 Switch IO (Mexico) 10005034-13x Manual
- June 8, 2024
- Simon
Table of Contents
- Simon
- S100 Switch IO (Mexico)
- SKU: 10005034-13x
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Association LED
- Parameter 10: Delay ON
- Parameter 11: Activation TIME
- Parameter 12: Behaviour of LED in repose
- Parameter 13: Lock Input
- Parameter 15: Reset default
- Parameter 16: Delay OFF
- Parameter 19: Press action
- Parameter 20: Identify
- Parameter 21: State of charge
- Parameter 23: Calibration Required
- Parameter 27: Lock long press
- Parameter 9: Calibration
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Simon
S100 Switch IO (Mexico)
SKU: 10005034-13x
Quickstart
This is a ****
On/Off Power Switch
for
.
To run this device please connect it to your mains power supply.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Simon Electronic Switch IO integrated by Electronic Switch that provides power Switch and Rocker that provides Z-Wave communication attributes.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 3| On/Off Report when load state is changed:- On -> CC Basic, Basic Report,
Value 0xFF- Off -> CC Basic, Basic Report, Value 0x00Instant Power Consumption
vary over 10% and is stable almost 2sec- CC Meter, Meter Report, Electric
meter, Consumed, Watts, Size 4, Precision 1, Value (W)Calibration requirement
change. (If device needs to be calibrated and is Added into a Z-Wave network,
it will report after receive an Association Set of life line).- Calibration
required -> CC Configuration, Configuration Report, Param 23, Value 0xFF-
Calibration not required -> CC Configuration, Configuration Report, Param 23,
Value 0x00After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION
is sent.Report
---|---|---
2| 20| Ctrl On/Off Report when load state is changed:- On -> CC Basic, Basic
Report, Value 0xFF- Off -> CC Basic, Basic Report, Value 0x00
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Association LED
Allows to turn ON or OFF the central LED
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Turns the LED OFF |
---|---|
255 | Turns the LED ON |
Parameter 10: Delay ON
Sets the delay time to turn on the light
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Disables timing |
---|---|
1 – 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 – 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Parameter 11: Activation TIME
Sets the time the light stays on
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Disables timing |
---|---|
1 – 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 – 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Parameter 12: Behaviour of LED in repose
Sets the central led ilumination when the key is in repose state
Size: 1 Byte, Default Value: 0
SettingDescription
0 | LED OFF |
---|---|
255 | LED on at 20 percent of maximum level |
Parameter 13: Lock Input
Locks or Unlocks the direct control of the load
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Unlock the direct control of load |
---|---|
255 | Lock the direct control of load |
Parameter 15: Reset default
Resets groups, Z-Wave status, and some or all configurations depending on
the configuration value (write only)
Size: 2 Byte, Default Value: 0
SettingDescription
17170 | Parameters, except Lock long press are restored to default |
---|---|
39015 | Parameters, Groups, and Z-Wave status are restored to default value. |
Parameter 16: Delay OFF
Sets the delay time to turn off the light
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Disables timing |
---|---|
1 – 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 – 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Parameter 19: Press action
Controls the behavior of the product when the key is pressed
Size: 1 Byte, Default Value: 0
SettingDescription
0 | When short press, device toggles the load |
---|---|
1 | When short press, device turns ON the load |
2 | When short press, device turns OFF the load |
4 | When short press, device turns ON the load. When hold press from 2 seconds |
to 10 seconds device turns OFF the load. The Slider does not works.With this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action
Parameter 20: Identify
Allows to identify a product using its central LED (write only)
Size: 1 Byte, Default Value: 0
SettingDescription
255 | the central LED blinks for 5 seconds in order to identify the device |
---|
Parameter 21: State of charge
Reports the state of the charge (read only)
Size: 1 Byte, Default Value: 0
SettingDescription
45056 | Load is OFF |
---|---|
45057 | Load is ON |
45312 | Load is OFF |
45567 | Load is ON |
Parameter 23: Calibration Required
Reports if calibration is required or not (read only)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Calibration is not required |
---|---|
255 | It is necessary to calibrate the dimmer to work properly |
Parameter 27: Lock long press
Locks or unlocks the long press on the key
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Long press works as described previously |
---|---|
255 | Long press from 2 seconds to 20 seconds does not send a Node info. With a |
long press above 30 seconds, all parameters except Lock long press
Parameter 9: Calibration
Performs a device calibration
Size: 1 Byte, Default Value: 0
SettingDescription
1| Device performs calibration using Trailing and leading Edge and decides
which one is better
---|---
2| Device is calibrated using Trailing Edge.
3| Device is calibrated using Leading Edge
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:72.15:65.15 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-20016833 |
Z-Wave Product Id | 0x0267.0x0001.0x0000 |
Firmware Updatable | Updatable by Professional/Technician |
Neutral Wire Required | ok |
Supported Meter Type | Electric Energy |
Switch Type | Push Button with Indicator |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info V3
- Association V2
- Basic
- Configuration V2
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Meter V4
- Powerlevel
- Switch Binary
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.