SPECTRO-UV X-Series Bench and Display Lamps Instruction Manual
- October 30, 2023
- SPECTRO-UV
Table of Contents
OPERATOR’S MANUAL
X. Series
NDT
UV Bench and Display Lamps
**** LAMP CONTAINS MERCURY Manage in Accordance with Disposal Laws
06/22 AM09041.5
punted in U.S.A.
WARNING
UV light emitted from this product. Avoid eye and skin exposure to unshielded
products.
FOR PROFESSIONAL EXAMINATION USE ONLY
GENERAL OPERATION
- To prevent breakage, the UV tubes for 40-watt lamps are not installed when shipped. Install according to the tube replacement instructions in the”OPERATOR SERVICING” section of this manual.
- For 15-watt lamps, install the two mounting brackets according to the instructions provided in their packing envelope.
- NOTE: All other lamps have mounting brackets permanently attached.
- Connect the plug to a power outlet that complies with the electrical requirements specified on the lamp’s label.
- The power supply cord is the disconnect for this unit.
- To light the lamp, move the ON/OFF toggle switch on the end of the lamp to the “ON” position.
- To turn off the lamp, move the switch to the “OFF” position.
WARNING
Please read instructions in this manual carefully before using your Spectroline® lamp. Never use this equipment in any manner not specified in these instructions because the protection provided by the equipment may be impaired. We recom mend using Spectroline UV-absorbing protective eye and face wear. See Ordering Information for model numbers. This eye and face wear also improves contrast between the fluorescent area and the background and eliminates “blue haze” interference.
OPERATOR SERVICING
The following servicing instructions are intended for limited maintenance of
the X-Series lamps. Do not perform any servicing other than that contained in
these instructions.
Return the lamp to the factory for other maintenance not covered in this
section.
REPLACING THE UV TUBE(S)
-
Unplug the lamp.
-
For lamps without filters, proceed to step 4. For lamps with filters, detach the slim plastic edgepiece from the lamp’s end cap ( on the end with the power cord) by remov ing its two holding screws.
NOTE: Do not remove the endcap itself, which has four screws in it. -
Carefully slide out the filter assembly (filter and attached metal brackets and frame).
Gently set it aside on a flat surface. -
To replace a faulty tube, hold it by the metal bases located at either end. Rotate the tube slightly and gently lift it from the sockets. Install the new tube by reversing this procedure.
-
Where applicable, replace filter assembly by reversing the procedure in steps 2 and 3.
-
Plug in the lamp and test the function of the new tube(s).
REPLACING THE FILTER
- Unplug the lamp.
- Remove the eight holding screws attaching the two filter brackets to the filter frame.
- Remove the brackets by gently prying them upward with a flathead screwdriver or similar tool.
- Lift off and set aside the filter.
- Carefully install the new filter in the same position as the original filter, with the smooth surface facing outward.
- Snap the brackets back into position and replace all screws.
ENVIRONMENTAL SPECIFICATIONS
The Spectroline X-Series lamps are designed to be safe under the following
conditions:
-
Indoor use;
Altitude up to 2,000 m (6,562 ft.);
Temperature 5°C to 40°C (41°F to 104 °F); -
Maximum relative humidity 80% for temperatures up to 31 °C (88°F) decreasing linearly to 50% relative humidity at 40°C (104 °F);
-
Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage;
-
Installation Category II; Pollution Degree
ELECTRICAL SPECIFICATIONS
Model | Wavelength | Equipped With | 120V, 60Hz Amps |
---|---|---|---|
X-15A | UV-A | One 15W BLB Tube | 0.4 |
XX15A | UV-A | Two 15W BLB Tubes | 0.7 |
X-15N | UV-A | One 15W BL Tube, Filter Assembly | 0.4 |
XX-15N | UV-A | Two 15W BL Tubes, Filter Assembly | 0.7 |
X-30 | UV-A | One 30W BLB Tube | 0.8 |
X-40 | UV-A | One 40W BLB Tube | 0.6 |
XX-40 | UV-A | Two 40W BLB Tubes | 1.6 |
XX-40N | UV-A | Two 40W Tubes, Filter Assembly | 1.6 |
X-15B | UV-B | One 15W Tube/LONGLIFE Filter | 0.4 |
XX-15B | UV-B | Two 15W Tubes, LONGLIFE Filter | 0.7 |
X-15F | UV-C | One 15W Tube, LONGLIFE Filter | 0.4 |
XX-15F | UV-C | Two 15W Tubes, LONGLIFE Filter | 0.7 |
XX-15NF | UV-A/UV-C | Two 15W Tubes, LONGLIFE Filter | 0.7 |
XX-15BF | UV-B/UV-C | Two 15W Tubes, LONGLIFE Filter | 0.7 |
XX-15NB | UV-A/UV-B | Two 15W Tubes, LONGLIFE Filter | 0.7 |
X-15W | White Light | One 15W White Light Tube | 0.4 |
XX-15W | White Light | Two 15W White Light Tubes | 0.7 |
X-15G | UV-C | One 15W Clear Tube (Germicidal) | 0.4 |
XX-15G | UV-C | Two 15W Clear Tubes (Germicidal) | 0.7 |
X-30G | UV-C | One 30W Clear Tube (Germicidal) | 0.8 |
Long Wave (UV-A) 36bnm Medium Wave (UV-5) 312nm Short Wave (UV-G) Zb4nm
WARRANTY
The warranty policy for the X-Series UV lamps is provided on the Certificate
of Limited Warranty enclosed separately with each unit.
NOTE: For assistance of any kind, contact the Customer Service Department
at Spectro-UV. Call toll-free 1-866-230-7305. Give full details of the
difficulty and include the model and serial numbers of the unit and the date
of purchase. If return of the unit to the
factory is deemed necessary, shipping instructions will be provided. If an
estimate of charges for non warranty work or other service work is required,
a quote will be furnished upon evaluation of the unit. Out-of-warranty service
work will not be performed without customer approval.
SHIPPING
Carefully pack the unit in its original shipping container and packing
materials and ship it prepaid to the factory. Insure it for full value.
ORDERING INFORMATION
Description | Part No. |
---|---|
Tube-365nm 15W BLB | BLE-1800B |
Tube-365nm 15W BL | BLE-1T151 |
Tube-254nm 15W | BLE-1T155 |
Tube-312nm 15W | BLE-1T158 |
Tube-254nm 30W | BLE-1T305 |
Tube-White Light 15W | BLE-1T535 |
Tube-365nm 30W BLB | BLE-5000B |
Tube-365nm 40W BLB | BLE-7900B |
Filter-X-15N, XX-15N | 2F501 |
Filter-15W 254nm, 312nm, Multi-Band Lamps | 2F508 |
Filter–40W XX-40N (Two Required) | 2F951 |
Spectacles, UV-Absorbing | UVS-30 |
Goggles, UV-Absorbing | UVG-50 |
Face Shield, UV-Absorbing | UVF-80 |
1.888.610.7664
www.calcert.com
sales@calcert.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>