- 3.1 382306: Dragging camera from OC image pane to MG image pane
- 3.2 387201: Load balancing parameters for DIVAR IP allin-one 4000/6000
- 3.3 390503, 392474: Some SDK functions not working in alarm display
- 3.4 393949: OC max clients reached after several forced activations
- 3.5 393966: SDK events missing in SDK EventReceiver
- 3.6 395791: Export from DVR fails
- 3.7 398299, 398300, 398396: Tattile improvements
- 3.8 399322: Videojet 4000 multi with disabled Audio not configurable
- 3.9 375802: View recording prohibited
- 3.10 406477: Config Client Monitorgroup configuration slow
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Release Notes
BVMS 11.1.1 Patches SystemManager package
Date: 17-Mar-2023
1 Document History
This document is distributed online and updated on regular basis, whenever new patches are released and added to the package. The latest version of this document is always available on the Bosch Security and Safety Systems Download Store.
Date | Version | Changes |
---|---|---|
17.03.2023 | 1.0 | Initial release |
2 BVMS 11.1.1 Patches System Manager package
DIVAR IP System Manager application is the central user interface that offers an easy system setup, configuration and application software upgrade for DIVAR IP all-in-one 4000, DIVAR IP all-in-one 6000 and DIVAR IP all-in-one 7000 (DIP-73xx) systems.
The BVMS_11.1.1_Patches_SystemManager_package_1.0.zip contains a set of BVMS 11.1.1 patch installers software packages for the DIVAR IP System Manager application. It is used to install patches for BVMS 11.1.1 on the DIVAR IP appliances managed by the DIVAR IP System Manager.
2.1 Installation prerequisites and operation notes
- DIVAR IP System Manager application version 2.0.0 or higher shall be installed and started.
- To download the BVMS 11.1.1 Patches System Manager package 1.0, go to https:// downloadstore.boschsecurity.com/. Then, under the Software tab, select BVMS Appliances from the list and click Select.
- Locate the BVMS_11.1.1_Patches_SystemManager_package_1.0.zip file from the list of all available software packages, and save it to a storage medium such as a USB stick.
- Unzip the files on the storage medium. Do not change the folder structure of the unzipped files.
- Connect the storage medium to your DIVAR IP system and follow instructions in the Upgrading software section of, for example, DIVAR IP all-in-one 4000 / 6000 systems User Manuals to install desired BVMS patches on your DIVAR IP.
2.2 List of BVMS 11.1.1 patches available in the package
ID | Description |
---|---|
375802 | FIXED: View recording prohibited |
382306 | FIXED: Dragging camera from OC image pane to MG image pane not |
working properly
387201| FIXED: Proper load balancing parameters for DIVAR IP all-in-one
4000/6000 as iSCSI target within BVMS
390503, 392474| FIXED: Some SDK functions not working properly in alarm
display
393949| FIXED: Max. clients reached error after several forced
activations
393966 | FIXED: SDK events missing in SDK EventReceiver
395791 | FIXED: Export from DVR might fail
398299, 398300, 398396| FIXED: Problems with connectivity to Tattile
cameras
399322| FIXED: Videojet 4000 multi with disabled Audio not configurable
406477| FIXED: CC Monitorgroup configuration slow
2.3 Known limitations and issues
- DIVAR IP System Manager application version 2.0.0 or above must be installed before using the BVMS 11.1.1 Patches System Manager package.
- If DIVAR IP System Manager application version 1.5.0 is used, it may become nonresponsive while updating the user interface data, if many packages are installed. To avoid this, make sure you update DIVAR IP System Manager application to version 2.0.0 or above. Please see corresponding release notes for this application.
3 Release Notes for individual patches
3.1 382306: Dragging camera from OC image pane to MG image pane
Patch ID: | 382306 |
---|---|
Patch Title: | Dragging camera from OC image pane to MG image pane |
Patch Target Version: | BVMS-11.1.1.65 |
Patch Details:
This patch fixes issue 382306 that some objects had not been serializable and
are needed for drag & drop of cameras to a Monitor Group image pane.
Problem Details:
Issue 382306 caused the problem that dragging a camera from a standard
Operator Client image pane to a Monitor Group image pane does not work.
Affected Bosch VMS Components / Machines:
– Bosch VMS Operator Client
– Cameo SDK
List of Replaced Files:
– Bosch.Cctv.DeviceApi.dll [Version 11.1.1.68] –
Bosch.Vms.Client.OpClient.CameoSystem.CameoService.dll [Version 11.1.1.68] –
Bosch.Vms.Client.Shared.StreamVisualization.dll [Version 11.1.1.68]
3.2 387201: Load balancing parameters for DIVAR IP allin-one 4000/6000
Patch ID: | 387201 |
---|---|
Patch Title: | Load balancing parameters for DIVAR IP all-in-one |
4000/6000
Patch Target Version:| BVMS-11.1.1.65
Patch Details:
This patch fixes issue 387201 that currently the preliminary (incorrect) load
balancing parameters are used when using DIVAR IP all-in-one 4000/6000 as
iSCSI target within BVMS.
Problem Details:
Issue 387201 caused the problem that incorrect load balancing parameters are
used when using DIVAR IP all-in-one 4000/6000 as iSCSI target within BVMS
which may lead to reduced recording throughput of the device or excessive
number of iSCSI sessions requested from the device.
Important Hint:
The new values will be used in the BVMS Configuration only when the storage
“DIVAR IP AIO 4000” and “DIVAR IP AIO 6000” were added after installing this
Patch.
Already configured iSCSI will NOT be migrated. In such a case the values need
to be adjusted manually to not bring the devices into an overload situation.
The following values need to be adjusted:
– DIVAR IP all-in-one 4000
Maximum bit rate: 250 Mbps
Maximum number of iSCSI sessions: 64
– DIVAR IP all-in-one 6000
Maximum bit rate: 400 Mbps
Maximum number of iSCSI sessions: 128
Affected Bosch VMS Components / Machines:
– Bosch VMS Config Client
List of Replaced Files:
– Conf\StorageConfig\SupportedStorages\storagetypes.xml
3.3 390503, 392474: Some SDK functions not working in alarm display
Patch ID: | 390503, 392474 |
---|---|
Patch Title: | Some SDK functions not working in alarm display |
Patch Target Version: | BVMS-11.1.1.65 |
Patch Details:
This patch fixes issue 390503 by making certain SDK functions working in alarm
display scenario.
This patch fixes issue 392474 by selecting the image pane correctly when
switching between rows and single row alarm panel.
Problem Details:
Issue 390503 caused the problem that SDK functions “GetSelectedImagePane”,
“GetCameraFromImagePane” and “SaveImagePane” are not working in alarm display.
Issue 392474 caused the problem that no image pane is selected in single row
alarm panel.
Affected Bosch VMS Components / Machines:
– Bosch VMS Operator Client
List of Replaced Files:
– Bosch.Vms.Client.OpClient.CameoSystem.CameoSpace.dll [Version 11.1.1.72] –
Bosch.Vms.Client.OpClient.CameoSystem.CameoSpace.Wpf.dll [Version 11.1.1.72] –
Bosch.Vms.ClientSDK.dll [Version 11.1.1.72]
3.4 393949: OC max clients reached after several forced activations
Patch ID: | 393949 |
---|---|
Patch Title: | OC max clients reached after several forced activations |
Patch Target Version: | BVMS-11.1.1.65 |
Patch Details:
This patch fixes issue 393949 by improving the behaviour of Operator Client
during forced activations.
Problem Details:
Issue 393949 caused the problem that after some forced activations the
Operator Client shows “max clients reached” although not too many clients are
connected.
Affected Bosch VMS Components / Machines:
– Bosch VMS Operator Client
– Bosch VMS Cameo SDK
List of Replaced Files:
– Bosch.Vms.Frontend.OpClient.Communication.dll [Version 11.1.1.92] –
Bosch.Vms.Frontend.OpClient.ServerManagement.dll [Version 11.1.1.92] –
Bosch.Vms.Frontend.OpClient.Wcf.dll [Version 11.1.1.92] –
Bosch.Vms.Shared.Communication.WcfClient.dll [Version 11.1.1.92]
3.5 393966: SDK events missing in SDK EventReceiver
Patch ID: | 393966 |
---|---|
Patch Title: | SDK events missing in SDK EventReceiver |
Patch Target Version: | BVMS-11.1.1.65 |
Patch Details:
This patch fixes issue 393966 by solving the problem to not get events from
the following system-devices:
– AlarmActivated, AlarmAccepted, AlarmUnaccepted, AlarmWorkflow, AlarmCleared
– OperatorAuthenticationRejected, UserAccountDisabledEvent
– LogMessage
– SystemInfoEvent, SystemWarningEvent, SystemErrorEvent
– TaskActivityState
– BackupStarted, BackupFinished, BackupFailed, BackupCameraFailed
Problem Details:
Issue 393966 caused the problem that SDK EventReceivers did not get events
from some system-devices.
Affected Bosch VMS Components / Machines:
– Bosch VMS Management Server
List of Replaced Files:
– Bosch.Vms.Backend.CentralServer.WcfServices.EventsAndStatesService.dll
[Version 11.1.1.79]
3.6 395791: Export from DVR fails
Patch ID: | 395791 |
---|---|
Patch Title: | Export from DVR fails |
Patch Target Version: | BVMS-11.1.1.65 |
Patch Details:
This patch fixes issue 395791 with a increased timeout for the track search.
Problem Details:
Issue 395791 caused the problem that an export from DVR is not possible if the
track search needs more than 5 seconds.
Affected Bosch VMS Components / Machines:
– Bosch VMS Management Server
– Bosch VMS Operator Client
List of Replaced Files:
– Bosch.Vms.VsdkToDibosAdapter.Imp.dll [Version 11.1.1.77]
3.7 398299, 398300, 398396: Tattile improvements
Patch ID: | 398299, 398300, 398396 |
---|---|
Patch Title: | Tattile improvements |
Patch Target Version: | BVMS-11.1.1.65 |
Patch Details:
This patch fixes issue 398299 by solving the authentication problem with
regards to Tattile cameras.
This patch fixes issue 398300 by mapping the events from different Tattile
cameras correctly.
This patch fixes issue 398396 by solving the problem of not showing events of
Tattile cameras after changing the system.
Problem Details:
Issue 398299 caused the problem that the authentication to a Tattile camera
may fail if credentials are changed to another valid user.
Issue 398300 caused problems receiving events from different Tattile cameras
as they are mapped to only one camera.
Issue 398396 caused the problem that no events (alarms) of Tattile cameras are
shown if the system was changed, e.g. change port of the Tattile camera.
Important hint:
After installing the patch, the following configuration changes need to be
done once.
On the camera:
- On the Tattile camera upload the new “LPR_Event_Template.txt” file
In BVMS:
- Open “Edit” dialog of Tattile
- Press “Authenticate” to retreive updated information from camera
- Press “OK”
- Check that correct “Device Serial Number” is displayed on properties tab
- Save & Activate
This will change the configuration to use the device SN in BVMS.
Affected Bosch VMS Components / Machines:
– Bosch VMS Management Server
– Tattile camera
List of Replaced Files:
– AppDataLPR_Event_Template.txt
– AppDataServerDeviceAdapterSpring.Lpr.ServerSettings.xml
– Bosch.Vms.Backend.CentralServer.WcfServices.LicensePlateReaderService.dll
[Version 11.1.1.89] – Bosch.Vms.Backend.DeviceAdapter.TattileAdapter.dll
[Version 11.1.1.89] – Bosch.Vms.Server.Lpr.LprAdapter.dll [Version 11.1.1.89
3.8 399322: Videojet 4000 multi with disabled Audio not configurable
Patch ID: | 399322 |
---|---|
Patch Title: | Videojet 4000 multi with disabled Audio not configurable |
Patch Target Version: | BVMS-11.1.1.65 |
Patch Details:
This patch fixes issue 399322 being able to configure Videojet 4000 multi
where Audio was disabled via license.
Problem Details:
Issue 399322 caused the problem that Videojet 4000 multi with disabled Audio
was not configurable in Config Client.
In the Operator Client Alarms are visible like “Device x.y.z could not be
checked…”.
After Patch installation:
To make the changes of the Patch effective, please do the following:
– Start Config Client.
– Use the “Update states and capabilities” functionality in the toolbar to
update the device capabilities.
Affected Bosch VMS Components / Machines:
– Bosch VMS Management Server
– Bosch VMS Config Client
3.9 375802: View recording prohibited
Patch ID: | 375802 |
---|---|
Patch Title: | View recording prohibited |
Patch Target Version: | BVMS-11.1.1.65 |
Patch Details:
This patch fixes issue 375802 in the way that the time span in which the
viewing of the most recent recording is prohibited can be configured in the
OperatorClient.exe.config. With this Patch the value is set to 120 seconds.
Problem Details:
Issue 375802 caused the problem that pre-/post-alarm recordings were
accessible in OperatorClient on realtime even if user has no “live view”
authorizations.
Affected Bosch VMS Components / Machines:
– Bosch VMS Operator Client
List of Replaced Files:
– AppDataClientOpClientApplicationWiringOperatorClient.exe.config
3.10 406477: Config Client Monitorgroup configuration slow
Patch ID: | 406477 |
---|---|
Patch Title: | Config Client Monitorgroup configuration slow |
Patch Target Version: | BVMS-11.1.1.65 |
Patch Details:
This patch fixes issue 406477 by avoiding to load the camera tree for monitor
configuration multiple times.
Problem Details:
Issue 406477 caused the problem that Monitorgroup configuration is slow with
higher number of decoders in Config Client.
Affected Bosch VMS Components / Machines:
– Bosch VMS Config Client
List of Replaced Files:
– Bosch.Vms.Config.DeviceTree.Extension.AMG.dll [Version 11.1.1.95] –
Bosch.Vms.Config.DeviceTree.Extension.AMG.Wpf.dll [Version 11.1.1.95]
Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
References
- Download Area | Bosch Security and Safety Systems
- Download Area | Bosch Security and Safety Systems
- Download Area | Bosch Security and Safety Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>