JVC KY-PZ510NW 4K PTZ Remote Camera Instruction Manual

October 30, 2023
JVC

JVC KY-PZ510NW 4K PTZ Remote Camera

Product Information: 4K PTZ Remote Camera (NDI|HX)

The KY-PZ510NW/NB is a 4K PTZ remote camera that supports NDI|HX3. It comes with firmware v2.0.92 which provides various features such as NDI settings, H.265/HEVC support, and more. The camera can be updated with v2.0.92 to enable NDI|HX3 feature.

Firmware v2.0.92

The firmware v2.0.92 provides new features and settings for the KY-PZ510 series. The firmware version can be confirmed on the View Remote Screen after updating.

Updating the Firmware

To update the firmware, please refer to the original KY-PZ510 series instruction manual and follow the instructions provided in it.

NDI|HX3 Settings

After updating the firmware to v2.0.92, NDI|HX3 feature can be enabled on the KY-PZ510NW/KY-PZ510NB cameras. When setting the Video Format to 29.97p, 30p, 59.94p, 60p, 59.94i, or 60i, you can select NDI|HX3:H.264 1080@60 or NDI|HX3:H.265 1080@60 for streaming. And when setting the Video Format to 25p, 50p, or 50i, you can select NDI|HX3:H.264 1080@50 or NDI|HX3:H.265 1080@50 for streaming.

Note that the bit rate will be high and you need to check your network bandwidth. Some decoders may not be supported. The format is 1080p only.

NDI Settings Menu

The NDI Settings menu is available only for KY-PZ510NB/KY-PZ510NB cameras. It allows you to set the channel name, NDI Discovery Server, NDI Discovery Server Address, NDI Multicast Server, NDI Multicast Server Address, NDI Multicast Mask, and NDI Multicast TTL.

The NDI multicast address and NDI multicast mask set the range of multicast addresses that are randomly set when performing NDI multicast distribution.

Product Usage Instructions

  1. Update the firmware to v2.0.92 by following the instructions provided in the original KY-PZ510 series instruction manual.
  2. To enable NDI|HX3 feature, select NDI|HX3:H.264 1080@60 or NDI|HX3:H.265 1080@60 for streaming when setting the Video Format to 29.97p, 30p, 59.94p, 60p, 59.94i, or 60i. And select NDI|HX3:H.264 1080@50 or NDI|HX3:H.265 1080@50 for streaming when setting the Video Format to 25p, 50p, or 50i.
  3. Check your network bandwidth before using the NDI feature as the bit rate will be high and some decoders may not be supported.
  4. If you have a KY-PZ510NB/KY-PZ510NB camera, you can access the NDI Settings menu to customize your settings.

Note

  • v2.0.92 is for KY-PZ510 series.
  • If you update KY-PZ510NW/KY-PZ510NB with v2.0.92, you can use NDI|HX3.

JVCKENWOOD Corporation Global Marketing Group Marketing Department Media Business Division

The speciation bong and appearance of this unit are subject to change for further improvement without pro notice

Details

For details on settings and operations refer to INSTRUCTIONS’ on the website
Please check the last INSTRUCTIONS, tools, ate, from the UR, below

North America:
http://pro.jve.com/peolimain.|sp

Europe:
htps://cu.jve.com/apro

Thank you for purchasing this product
Before beginning to operate this unit, plasse read the “INSTRUCTIONS” carefully to ensure proper use of the product.
In particular, please need through the “Safety Precautions’ to ensure safe use of the product. After reading, store them with the warranty card and refer to them whenever needed
The sectial number is crucial for the purpose of quality control. After purchasing this product, please check to ensure that the serial rumber is indicated contact on this product, and the same serial number is also indicated on the warranty cad.

Important Safety Instructions

  1. Read these instructions.

  2. Keep these instructions.

  3. Heed al warnings.

  4. Follow all instructions.

  5. Do not use this apparatus near water.

  6. Clean only with dry cloth.

  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

  9. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they ext from the apparatus.

  10.  Onty use attachments/accessories specified by the manutacturer.

  11. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
    When a cart is used, use caution when moving the cart apparatus combination to avoid injury from $p-over.

  12. Unplug this apparatus during lightning storms or when unused lor long periods of time.

  13. Refer al servicing to qualified service personnel.
    Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liguid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Instruction manual

This manual is for Firmware v2.0.92.
Also, please refer to original KY-PZ510 series instruction manual.
http://www32.jvckenwood.com/jvc/manual_e/index.asp

JVC KY-PZ510NW 4K PTZ Remote Camera-FIG1

Firmware v2.0.92

When you update KY-PZ510 series, you can confirm firmware version on the View Remote Screen..

JVC KY-PZ510NW 4K PTZ Remote Camera-FIG3

NDI®|HX3 only for KY-PZ510NW/KY-PZ510NB.

When you update KY-PZ510NW/KY-PZ510NB, you can select NDI|HX3. Please select Recommended.①

JVC KY-PZ510NW 4K PTZ Remote Camera-FIG4

Note

  • Automatically configures appropriate settings for First stream and Second stream.
  • The bit rate will be high. Please check your network bandwidth.
  • Some decoders are not supported.
  • Format is 1080p only.

NDI Settings menu only for KY-PZ510NB/KY-PZ510NB.

JVC KY-PZ510NW 4K PTZ Remote Camera-FIG5

Note

  • The NDI multicast address and NDI multicast mask set the range of multicast addresses that are randomly set when performing NDI multicast distribution.
  • Example: If the NDI multicast address is set to 239.255.0.10 (Default) and the NDI multicast mask is set to 255.255.0.0 (Default), multicast addresses for video and audio will be randomly selected from the range of 239.255.0.0 to 239.255.255.255.

History

April 2023 Release this instruction manual.