WolfPack HDTVFIX1600E 4K 30 Hz 16×16 HDMI Matrix Switch with Apps and WEB GUI User Manual
- October 30, 2023
- WOLFPACK
Table of Contents
- WolfPack HDTVFIX1600E 4K 30 Hz 16×16 HDMI Matrix Switch with Apps and WEB
- Important Safety Instructions
- FCC STATMENT
- Product Introduction
- Features
- Specification
- Connection Diagram
- Panel description
- Common Problem Shooting
- Warranty Information
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WolfPack HDTVFIX1600E 4K 30 Hz 16×16 HDMI Matrix Switch with Apps and WEB
GUI
Safety Reminder
To protect the device and operating personnel from electrostatic discharge, you need to check and ensure that the device is grounding well before the device is powered on. Please observe the following when you install, use, maintain this equipment
- Make sure the device ground connection.
Important Safety Instructions
- Do not expose this apparatus to rain, moisture, dripping, or splashing, and no objects filled with liquids, such as vases, shall be placed on the apparatus.
- Do not install or place this unit in a bookcase, built-in cabinet, or in another confined space. Ensure the unit is well-ventilated.
- To prevent the risk of electric shock or fire hazards due to overheating, do not obstruct the unit’s ventilation openings with newspapers, tablecloths, curtains, and similar items.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
- Do not place sources of naked flames, such as lighted candles, on the unit.
- Clean this apparatus only with a dry cloth.
- Unplug this apparatus during lightning storms or when unused for long periods of time.
- Protect the power cord from being walked on or pinched particularly at plugs.
- Only use attachments/accessories specified by the manufacturer.
- Refer all servicing to qualified service personnel.
FCC STATMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the decoder.
- Connect the equipment to an outlet on a circuit different from that to which the decoder is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Product Introduction
This is a new WolfPack 4K 30 Hz 16×16 HDMI Matrix Switch with Apps & WEB GUI, the resolution canupto4K30Hzandall ports are HDCP compliant. With the friendly user control methods: IR remote control, 2-Press push buttons with background blue light, WEB GUI and the iOS/Android APP control, support the WEB smart EDID management, this matrix switcher can work with the Blu-Ray Players, Set- Top boxes, Home Theater, and game consoles, etc HDMI input sources to route to the HDMI displays, it has been widely used in different audiovisual applications.
Features
- 16 HDMI inputs and 16 HDMI outputs
- Supports HDMI1.4, HDCP1.4
- The resolution can be up to 4K@30Hz
- Deep Color support 48/36/30/24-bit
- Supports LPCM 7.1CH, Dolby TrueHD, Dolby Digital, and DTS-HD Master Audio
- Supports IR remote control(IR remote control codes are available)
- Supports smart EDID management, including 8-output EDID, and 15 internal EDID.
- Supports RS-232 and TCP/IP Control(WEB GUI, APP)
- Supports 2-press push buttons control with blue lights
- Supports renaming the inputs and outputs
Specification
Name | WolfPack 4K 30 Hz 16×16 HDMI Matrix Switch with Apps & WEB GUI |
---|---|
Resolution | 480p, 576p, 720p, 1080i, 1080p@24/30/50/60Hz, 4K@30Hz, |
Input ports | 16 HDMI ports, 1 RS-232(control), 1 * RJ-45(control) |
Output ports | 16 Female HDMI ports, 1 RS-232(control) |
HDMI Distance | 10m/30ft for 4K30, 15m/45ft for 1080P@60Hz |
ESD Protection
| Human-body Model: ± 8kV (Air-gap discharge)
± 4kV (Air-gap discharge)
ESD Protection | 12 V 5A DC (US/EU standards, CE/FCC/UL certified) |
---|---|
Controlling | Supports remote control, front buttons control, RS232, LAN |
control
Input voltage| AC: 100VAC ~ 260VAC, 50/60 Hz, DC:12V 5A
Dimension(mm)| 480 252 44( mm)
Weight| 3.5Kg
Operating Temperature| 0 ºC~40 ºC/32 ºF~104 ºF
Storage Temperature| −20 ºC~60 ºC/−4 ºF~140 ºF
Connection Diagram
Packing
No. | Name | Qty | Unit |
---|---|---|---|
1 | HDTVFIX1600E | 1 | Pcs. |
2 | DC 12V5A power adapter | 1 | Pcs |
3 | Remote Control | 1 | Pcs |
Panel description
Front panel
- LCD screen: for the switching, EDID, IP, etc information display.
- OUTPUT: 16 HDMI output buttons
- INPUT: 16 HDMI input buttons
- CONTROL:
- UP: for upward controlling
- EDID: Press it to enter EDID set mode. EDID Read: For example. in order to read the
- EDID of output port OUT5 to input port 1, we need to press the EDID button(the
- indicator of EDID lights) firstly, press button 1 on IN side secondly, then press UP or
- DOWN button to select OUT5, at the same time button 5 on OUT side lights, and finally
- Press ENTER button (the indicator of ENTER button will flash for one time ).
- SAVE: Press to save the switching status.
- Down: for upward controlling
- ENTER: Press to confirm to save the setting.
- RECALL: Press it to recall the presets/scenes.
- IR: IR receiver for the IR remote control
Back panel
- For the ground wiring
- INPUT: 8 female HDMI Input ports
- OUTPUT: 8 female HDMI output ports
- RS232 IN: Female RS232 port for the R232 control
- RS232 OUT: To control the surrounding RS232 equipment
- LAN: for the IP/TCP control, the default IP address is 192.168.1.80
- DC12V: power supply port
- ON/OFF: power off/on switch
Matrix Switcher control
This Matrix switcher can support IR remote, APP, RS232/TCP/IP software, WEB GUI browser, or the front push-button control.
Remote Control
Users also can control this matrix switcher with the remote control.
Channel switching:
- Press the input from number “1~8”, then press “SWITCH”, then press the output from number“1~8”, can press the outputs continually.
- Eg. Switch input 1 to output 1, 2, 3:
- 1 SWITCH 1, 2, 3
Scene Save
- Press “SAVE”, then press the scene number from “1~8”.
- Eg, Save switching input 1 to output 1,2,3 to scene 2:
- “SAVE” “2”
Scene Recall
- Press “RECALL”, then press the scene number from “1~8”.
- Eg, Recall scene 2:
- “RECALL” “2”
EDID Setting
- Press the “EDID” button to enter EDID setting mode, then press number “0” to choose the needed EDID, then press “ENTER” to confirm, or press number “0” to cancel or return to the home page.
- “EDIT “0 “ ENTER”
WEB GUI browser Control
Users also can use the WEB browser to control the matrix switcher, users can have the matrix switcher connected to the PC with the LAN cable directly or have the matrix switcher connected to the same network switch. The default IP address of the matrix switcher is 192.168.1.80. After opening the browser, users can type the matrix switcher IP address and press enter: The default user name is admin and the password is admin.
- After login, it will turn to the “Home” interface, and users can do the sources switching, scenes recall, and save.
- On the input and output buttons, users also can view the active ports by the indicator:
- Custom/Caption interface for users to change/rename the input, output, and scene names, for changing the names, it can support total of 8 characters and it does not support the blank between the characters. After users changed the names, need to click “Submit” and then this interface will refresh automatically.
- Through this interface, users also can use the RS232 OUT on the back of the matrix switcher to control the other RS232 devices by sending the HEX format codes:
- EDID interface for users to set up the EDID for each input, with 16 internal EDIDs for selection or use the 16 outputs EDID.
- The setup interface is for users to set up the IP address, baud rate, Buzzer on/off, or language selections, after changing the IP address, will need to reboot the matrix switcher.
- The account interface is for users to change the login user name and password, the default user name and password is admin.
APP control
- Users can download the APP from Google Play or Apple Store by searching keywords “MCS”, then need to make sure the Matrix switcher is connected to the WIFI router and the mobile device is connected to the same WIFI. The default IP address of the matrix switcher is 192.168.1.80. Open the APP and Enter the IP address of the matrix switcher:
- Click Enter and login with the username and password, the default User name is admin, password is admin. Click Submit to log in after typing the correct user name and password, and it will turn to the home interface for the sources Switch, Scene Recall/Save:
- Users also can rename the input, output, and scenes by“Custom” tap:
- Users can set up the EDID for each input by the “EDID” Tap:
- Users can set up the IP address, and buzzer on/off by the “Setup” Tap:
- Users can log in a username and password by the “Account” Tap:
The 3rd Party Control command LAN
- IP address: 192.168.1.80 (default IP)
- Protocol: UDP
- Port: 4000
- Command: send as hex
Control instruction | Functional description |
---|---|
EB 90 0C 00 00 80 0B 02 (x-1) (y+7) 00 00 | Switch [x] input to [y] output |
EB 90 0C 00 00 80 09 02 (0X) 00 00 00
| Save the current scene to [X], [X] means the number
keys from 1 to 9
EB 90 0C 00 00 80 08 02 00 (0Y) 00 00
| Load the input/output switching saved in [Y], [Y]
means number keys from 1 to 9
- For example, input 1 Switch output 6, send: EB 90 0C 00 00 80 0B 02 00 0D 00 00
- (1-1)=0, Hex is 00, (6+7) =13, Hex is 0D.
- If input 1 Switch output 6, 7, 8, send EB 90 0C 00 00 80 0B 04 00 0D 0E 0F 00 00
- 04 00 0D 0E 0F means: 04 there are 4 ports for switching (1 input and 3 outputs), the first one
- 00 is the input port, and the remaining 0D 0E 0F are the output ports.
- EB 90 0C 00 00 80 09 02 02 00 00 00, save the previous scene to the 02;
- EB 90 0C 00 00 80 08 02 00 02 00 00, load 02 scenes;
- EB 90 0C 00 00 80 0B 02 01 0A 00 00
RS232
- Baud rate: 9600, N, 8, 1
- Use RS232 direct cable
Control instruction | Functional description |
---|---|
[x] X [y]. | Switch [x] input to [y] output |
Save [X]. | Save current scene to [X], [X] means number keys from 1 to 9 |
Recall [Y].
| Load the input/output switching saved in [Y], [Y] means number keys
from 1 to 9
Buzzer on.| Turn on the beep sound
Buzzer off.| Turn off the beep sound
Common Problem Shooting
- Q: Serial port operation is out of order, can not control to switch?
- A: The serial port is damaged or not started Solution: Make sure the port uses a direct serial port line, and check the connection of the PC software serial port.
- Power failure: Check the power fuses and connecting lines;
- Signal interference: Make sure the cables and plugs are connected well, the cables meet the requirements, the system is ground connected well, and the AC power between devices has the same grounding system;
- Accidental damage: Sent back to the manufacturer for reconditioning.
Warranty Information
The Company warrants that the process and materials of the product are not defective under normal use and service for 1 (1) year following the date of purchase from the Company or its authorized distributors. If the product does not work within the guaranteed warranty period, the company will choose and pay for the repair of the defective product or component, the delivery of the equivalent product or component to the user for replacement of the defective item, or refund the payment which users have made. The replaced product will become the property of the Company. The replacement product could be new or repaired. Whichever is longer, any replacement or repair of the product or component is for a period of ninety (90) days or the remaining period of the initial warranty. The Company shall not be responsible for any software, firmware, information, or memory data contained in, stored in, or integrated with the product repaired by the customer’s return, whether or not during the warranty period.
Warranty limitations and exceptions
Except above limited warranty, if the product is damaged by over-usage,
incorrect use, ignore, accident, unusual physical pressure or voltage,
unauthorized modification, alteration or services rendered by someone other
than the Company or its authorized agent, the company will not have to bear
additional obligations. Except using the product properly in the proper
application or normal usage.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>