HIS KB-M2-P90 Series Thin Client Small PC Enclosures Instruction Manual
- June 10, 2024
- HIS
Table of Contents
HIS KB-M2-P90 Series Thin Client Small PC Enclosures
Product Information:
The ENCL-TC01- , ENCL-TC02- , and ENCL-TC03- series Thin Client/Small PC Enclosures are designed for mounting and protecting thin clients or small PCs in industrial environments. The enclosure is made of durable materials to ensure proper protection and features cable routing trays to keep cables organized and secure. The enclosure includes an industrialair- cooled power supply that is more reliable than typical power supplies provided with thin clients or PCs.
Product Usage Instructions:
Follow the instructions below carefully to ensure proper installation:
IMPORTANT!
Follow these instructions carefully in order to ensure proper installation.
Failure to follow these instructions correctly could result in damage to your
product. Operator could be exposed to dangerously high voltage if AC power is
not connected properly. Verify all wiring is properly connected.
-
Mount the enclosure to HIS pedestal using the provided four 1/4-20 bolts. Pre-tapped holes are provided on specific HIS pedestal models. If you will not be using an HIS pedestal, mount the enclosure to a smooth wall surface using the hole pattern, or use HIS part number WB-ENCL1-xxx (not included). If enclosure wiring is not going through the rear hole already provided, punch conduit holes as required.
NOTE: Keyless latches should be operated with a screwdriver bit at least 6 mm (0.25″) wide to prevent scarring or scratching of the lock mechanism. -
Remove caps on Cable Routing Trays.
-
With power disconnected, hook up incoming power from mains supply to the AC input terminal blocks (“L” is black; “N” is white). Securely tighten terminal block screws.
-
Install monitor and other components at this time, following the instructions provided with those devices. Route all cables, including Ethernet and incoming power, at this time.
-
Hook up AC power to the monitor using an HIS CCAC- cable (not included). Disconnect and discard the end of the cable with the NA plug. Plug the C-13 connector end of the cable into the power input port on the rear of the monitor. Route the cable in through the hole in the pedestal to the Thin Client / PC enclosure. Connect the Molex connector end of the cable to the AC output connector. Route cables through Cable Routing Trays.
-
Install the Thin Client or PC onto the enclosure access door by using the provided mounting bracket holes or drilling custom hole FIGURE 2 – INSIDE VIEW OF ENCLOSURE locations into the mounting bracket.
NOTE: The mounting bracket can be adjusted left and right as needed to provide proper clearance for door to close. Pay special attention to clearance between any cable connections and internal enclosure components. -
Hook up all data cables to the Thin Client or PC, routing cables neatly through the Cable Routing Trays.
-
Determine the power requirements for your Thin Client or PC. An industrial air cooled power supply is provided in this Thin Client / PC enclosure and is much more reliable than the power supplies typically provided with Thin Clients or PCs. The internal power supply in ENCL-TC01 enclosures outputs 5/12 VDC (20 W at 5 VDC, 36 W at 12 VDC, with combined max output of 36 W), while the ENCL-TC02 outputs 5/24 VDC (20 W at 5 VDC, 36 W at 24 VDC, with combined max output of 36 W), and the ENCL-TC03 outputs 36 W at 19 VDC.
- For Thin Clients or PCs with a power requirement other than what is provided, or it is undesirable to cut the DC power cable, use the device manufacturer’s brick power supply. Install the brick power supply to the internal service panel (shown in Figure 2) and connect the AC power side to the AC power input terminal block using HIS part number MK-1OUTLET-xx. After completing the installation, continue to step 12.
- For Thin Clients or PCs with a power requirement of 5, 12, 19, or 24 VDC, carefully follow the next steps to connect power to the enclosure’s internal power supply.
IMPORTANT: Determine whether the ground is on the inside or outside of the DC jack. Failure to do this correctly could damage your Thin Client or PC by applying reverse polarity.
-
Cut the manufacturer’s DC power cable between the DC plug and the power brick, ensuring enough length to reach from the DC terminal block to the Thin Client or PC and allow the enclosure access door to open and close.
NOTE: If you would prefer not to cut your device’s power cable, you can use HIS part number MK-1OUTLET-xx. -
Strip the DC cable wires. Determine which of the bare DC wires is the ground wire by doing a continuity check. Attach a wire label that indicates it to be the ground (or COM) wire.
-
Refer to Figure 2. Hook the DC cable wires to the terminal block in the correct polarity [i.e. ground to COM (–)]. Connect the other wire to the appropriate 5, 12, 19, or 24 VDC terminal.
NOTE: The DC plug may have a third pin labeled “SENSE” or “SIGNAL.” This wire should be connected to the same VDC terminal as the DC (+).
WARNING: Failure do this correctly could damage your Thin Client or PC. -
Neatly route all cables through the Cable Trays. Ensure cables allow free swinging of the enclosure access door and will not be caught in the door seal.
WARNING: Failure to route cables without ensuring they won’t get caught in the door seal could cause leakage and damage the cables or other internal components and void your warranty. -
Install any other hardware on the internal service panel as required.
-
Reinstall the cable routing tray caps that were previously removed in step 2.
-
Power up the Thin Client or PC and test the system before closing and latching the enclosure access door. WARNING: Failure to close the enclosure access door may result in water damage to internal components in a wet environment and void your warranty.
99089D • December 20, 2022
www.HopeIndustrial.com
International: +1 678-762-9790
UK: +44 (0) 20 7193 2618
© 2023 Hope Industrial Systems, Inc.