KAIDENG WVC-2400 Micro Inverter User Manual

June 10, 2024
KaiDeng

KAIDENG-logo

KAIDENG WVC-2400 Micro Inverter

Product Information

Micro Inverter – WVC-2400
The WVC-2400 Micro Inverter is recommended to be used with panels of 4×750 watts. It has an output voltage mode of 120/230V Auto switch. The PV Open circuit voltage is 30-60VDC and the operating voltage range is 22-60V. The starting voltage range is also 22-60V. The short-circuit current is 4x28A and the maximum working current is 4x23A.

Output Parameters

Output parameters @120V @230V
Output peak power 2600Watt 2600Watt
Rated output power 2400Watt 2400Watt
Output current 20A 10.5A
AC voltage range 80-160VAC 180-280VAC
AC frequency range 48-51Hz/58-61Hz 48-51Hz/58-61Hz
Power factor >95% >95%
Number of branch connections 2PCS Single 4PCS Single
Output efficiency 95% 95%

The WVC-2400 Micro-Inverter has a static MPPT efficiency of 99.5% and the maximum output efficiency loss of power at night is 95%.

Product Usage Instructions

  1. Install the WVC-2400 Micro Inverter according to the installation manual provided.
  2. Connect the Micro Inverter to the solar panels of 4×750 watts.
  3. Ensure that the PV Open circuit voltage is within the range of 30-60VDC.
  4. Connect the AC output to the grid in either 120V or 230V mode, depending on your requirement.
  5. Ensure that the AC voltage and frequency range is within the specified range for optimal performance.
  6. The WVC-2400 Micro-Inverter has a power factor of >95%, which ensures efficient power conversion.
  7. The Micro-Inverter has multiple branch connections, either 2PCS Single or 4PCS Single, depending on your requirement.
  8. The Micro-Inverter has a high static MPPT efficiency of 99.5%, which ensures maximum power generation from the solar panels.
  9. The maximum output efficiency loss of power at night is 95%.

IoT Monitoring Platform

Smart mobile “core” life

  • CO-2-induced environmental analysis

  • Daily and total energy generation in kWh

  • Actual DC input voltage, current, and power

  • Actual AC output voltage, current, and power

  • Inverter temperature

  • Historical (daily, weekly, monthly) power curve

  • Power losses due to weather-induced effects

  • Optional limitation of power output

  • Online switch for the inverter start stopKAIDENG-WVC-2400-Micro-Inverter-fig- \(1\) KAIDENG-WVC-2400-Micro-Inverter-fig- \(2\)

  • CO-2-induced environmental analysis

  • Daily and total energy generation in kWh

  • Actual DC input voltage, current, and power

  • Actual AC output voltage, current, and power

  • Inverter temperature

  • Optional limitation of power output

  • Online switch for the inverter start stop

  • Historical (daily, weekly, monthly) power curve

Specification

model WVC- 2400
Recommend use panels 4*750Watt
Output voltage mode 120/230V Auto switch
PV Open circuit voltage 30-60VDC
Operating voltage range 22-60V
Starting voltage range 22-60V
short-circuit current 4*28A
Maximum working current 4*23A
Output parameters @120V
Output peak power 2600Watt
Rated output power 2400Watt
Output current 20A
AC voltage range 80-160VAC
AC frequency range 48-51Hz/58-61Hz
Power factor >95%
Number of branch connections. 2PCS(Single)
Output efficiency @120V
Static MPPT efficiency 99.5%
Max output efficiency 95%
Loss of power at night <0.5W
Total current harmonics <5%

Appearance and technical features

Temperature range -40°C to +65°C
Size(L×W×H) 370mm×300mm×41.6mm
Net amount 3.0kg
Waterproof grade Ip65 NEMA3R
Heat dissipation mode Self-cooling
Communication  mode 433MHz
Power transmission mode Reverse transmission,Load priority
monitoring system APP
Electromagnetic  Detection EN61000-6-1:2007   EN6100-6-3:2007+A1:2011+AC:2012
Power Grid standard EN50549-1、EN  50549-2、NBR  16149:2013、UL1741
Power grid detection IEC/EN 62109-1、 IEC/EN 62109-2、 IEC 62116、IEEE 1547
Certificate CE,ETL,INMETRO,Patented  technology

Packing weight

Specifications Each(Packing) Box(4PCS)
weight 4.36KG 18.38KG
Size 430×375×140mm 430×405×380mm

Package Detailed

KAIDENG-WVC-2400-Micro-Inverter-fig- \(5\)

System diagram

KAIDENG-WVC-2400-Micro-Inverter-fig- \(6\)

With N wire connection (Single phase 120/230V)

No N wire connection(Single phase 120V)

Note:
You can purchase a professionally customized AC bus with a T-type connector. Use this AC bus as the AC bus for each branch. Connect it hand in hand to form a modular micro-inverter branch wiring system.

LED indicator function of micro-inverter

  1. Red light keeps on ——————————–The equipment enters the preparatory working state;
  2. Red light flashes ———————————- The device enters the delayed start-up state;
  3. Blue light flashes quickly ————————MPPT maximum power point search status;
  4. Blue light keeps on——————————–MPPT maximum power point locked state;
  5. Blue light turns to red light for a long time—-
    • Island protection;
    • Frequency protection;
    • Fault;
    • Software shutdown;
    • AC voltage over-voltage protection;
    • DC voltage over-voltage protection;

Normal working indicator flashing process
Connect the micro-inverter correctly to the AC and DC terminals and then power on:
The red light keeps on for 3 seconds → the red light flashes for 30 seconds → the blue light flashes quickly (MPPT maximum power point search) → the blue light keeps on, (MPPT lock).

DOWNLOAD Cloud Intelligence APP

Please use the QR code to scan and install the “Cloud Intelligence” client application, System version: Android 5.0, IOS 9 and above.

KAIDENG-WVC-2400-Micro-Inverter-fig- \(9\)

Note:

  • Connect the two communication antennas on the collector (Modem) as required;
  • Place the collector in an appropriate location to ensure that the wifi signal source can be received normally and Form a good communication distance with the inverter;
  • The connected Wi-Fi network needs to be in 2.4G communication mode;
  • Please reset the collector for the first use;

Reset
Press and hold the reset button for more than 5 seconds, and Reday will go out and light up again after 5 seconds. Release the button at this time, and the device will complete the reset.

Add device

Open the intelligent monitoring software “Cloud Intelligence” APP to log in Account, click the “+” icon in the upper right corner to start adding. If a device has been created under the current account,(You can click on the device icon below to enter the details page for query or operation)

Entry equipment

When the smart APP changes to the QR code scanning state, scan the QR code label at the bottom of the Modem. At this time, the APP will automatically collect the body code of the Modem,and automatically jump to the Wi-Fi connection page, and enter the current Wi-Fi Click Next after the password;

Distribution network

Connect the Modem to the power supply as required, and quickly press the “Reset” button. When the “Reday” indicator turns from a long on state to a fast flashing state, the Modem will enter the network distribution state;

Initialization

After completing the network configuration of the modem, return to the phone initialization device operation page,check the “I have completed the above operations” below and click the “start connection” button, then the page will jump to the signal search page and the Link on the modem The indicator light will become a fast flashing state. When a WiFi signal is found,the indicator light will flash slowly until the network configuration is completed, and the indicator light will return to a steady state. The page jumps to the completion page, please click “Finish”

Add inverter

When the initialization is completed, please click the “Settings” menu in the upper right corner, find the inverter list item on the setting page, click the “Edit” button, and fill in the 8-digit code on the inverter to complete the inverter Add to.

Remarks

  1. When multiple inverters need to be added, theIn the English state, “,” comma separated and ended. Such as: 60001234, 6000E312,
  2. Each Modem can monitor 60 inverters at the same time;3. A total of 2 lists, each list can be filled with 30 inverter codes;

Features

Smart APP can realize real-time data transmission with the cooperation of Alibaba Cloud IoTThrough graphs and graphic displays in time, users can understand the operation of the power station. The user can monitor the operation and adjust the output power function of the system.

KAIDENG-WVC-2400-Micro-Inverter-fig- \(17\)

Cloud Intelligence APP

INTELLIGENT Iot MONITORING MODEM
Number of data collectors per Modem Built-in WiFi IoT data terminal Can be used on any smart device (Android/iOS)

  • CO-2-induced environmental analysis
  • Daily and total energy generation in kWh
  • Actual DC input voltage, current, and power
  • Actual AC output voltage, current, and power
  • Inverter temperature
  • Historical (daily, weekly, monthly) power curve
  • Power losses due to weather-induced effects
  • Optional limitation of power output
  • Online switch for the inverter start stopKAIDENG-WVC-2400-Micro-Inverter-fig- \(1\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KaiDeng User Manuals

Related Manuals