Dongguan Kaideng Energy Technology Co Ltd WVC-1600 Micro Inverter User Manual

June 10, 2024
Dongguan Kaideng Energy Technology Co Ltd

Dongguan-Kaideng-Energy-logo

Dongguan Kaideng Energy Technology Co Ltd WVC-1600 Micro Inverter

Dongguan-Kaideng-Energy-Technology-Co-Ltd-WVC-1600-Micro-Inverter-
product

Product Information

The WVC-1600 Micro Inverter is a model of micro inverter that is recommended to be used with panels of 4500Watt. The micro inverter has an output voltage mode of 120/230V Auto switch and can handle a PV Open circuit voltage of 30-60VDC. The operating voltage range is from 22-60V, while the starting voltage range is also from 22-60V. The micro inverter has a short-circuit current of 418A and can handle a maximum working current of 4*16A. It has an output peak power of 1600Watt and a rated output power of 1550Watt. The AC voltage range is from 80-160VAC for 120V output and 180-280VAC for 230V output. The AC frequency range is from 48-51Hz/58-61Hz for both 120V and 230V output. The power factor for the micro inverter is greater than 95%. It has three branch connections for single panel connection and six branch connections for multiple panel connection. The static MPPT efficiency for the micro inverter is 99.5% with a maximum output efficiency loss of power at night being 95%.

Product Usage Instructions

  1. Select panels that are recommended for use with the WVC-1600 Micro Inverter. Panels of 4*500Watt are recommended.
  2. Connect the panels to the micro inverter ensuring that the PV Open circuit voltage does not exceed 30-60VDC.
  3. Ensure that the operating voltage range and starting voltage range are within 22-60V.
  4. Connect the micro inverter to the AC power supply, ensuring that the AC voltage range is within 80-160VAC for 120V output and 180-280VAC for 230V output.
  5. Ensure that the AC frequency range is within 48-51Hz/58-61Hz for both 120V and 230V output.
  6. Ensure that the power factor of the micro inverter is greater than 95%.
  7. If connecting multiple panels, ensure that the micro inverter has six branch connections available for connection.
  8. Once all connections are made, turn on the micro inverter to start producing power.

IoT Monitoring Platform

Smart mobile “core” life

  • CO-2 induced environmental analysis
  • Daily and total energy generation in kWh
  • Actual DC input voltage, current and power
  • Actual AC output voltage, current and power
  • Inverter temperature
  • Historical (daily, weekly, monthly) power curve
  • Power losses due to weather induced effects
  • Optional limitation of power output
  • Online switch for the inverter start stop

Communication mode

Dongguan-Kaideng-Energy-Technology-Co-Ltd-WVC-1600-Micro-Inverter-
fig-2

  • CO-2 induced environmental analysis

  • Daily and total energy generation in kWh

  • Actual DC input voltage, current and power

  • Actual AC output voltage, current and power

  • Inverter temperature

  • Optional limitation of power output

  • Online switch for the inverter start stop

  • Historical (daily, weekly, monthly) power curve

SPECIFICATIONS

model WVC- 1600
Recommend use panels 4*500Watt
Output voltage mode 120/230V Auto switch
PV Open circuit voltage 30-60VDC
Operating voltage range 22-60V
Starting voltage range 22-60V
short-circuit current 4*18A
Maximum working current 4*16A
Output parameters @120V
Output peak power 1600Watt
Rated output power 1550Watt
Output current 13.3A
AC voltage range 80-160VAC
AC frequency range 48-51Hz/58-61Hz
Power factor >95%
Number of branch connections. 3PCS(Single)
Output efficiency @120V
Static MPPT efficiency 99.5%
Max output efficiency 95%
Loss of power at night <0.5W
Total current harmonics <5%
Temperature range -40°C to +65°C
--- ---
Size(L×W×H) 370mm×300mm×41.6mm
Net amount 3.0kg
Waterproof grade Ip65 NEMA3R
Heat dissipation mode Self-cooling
Communication  mode 433MHz
Power transmission mode Reverse  transmission,Load  priority
monitoring system APP
Electromagnetic  Detection EN61000-6-1:2007   EN6100-6-3:2007+A1:2011+AC:2012
Power Grid standard EN50549-1、EN 50549-2、NBR 16149:2013、UL1741
Power grid detection IEC/EN 62109-1、 IEC/EN 62109-2、 IEC 62116、IEEE 1547
Certificate CE,ETL,Patented technology
Temperature range -40°C to +65°C
--- ---
Size(L×W×H) 370mm×300mm×41.6mm
Net amount 3.0kg
Waterproof grade Ip65 NEMA3R
Heat dissipation mode Self-cooling
Communication  mode 433MHz
Power transmission mode Reverse  transmission,Load  priority
monitoring system APP
Electromagnetic  Detection EN61000-6-1:2007   EN6100-6-3:2007+A1:2011+AC:2012
Power Grid standard EN50549-1、EN 50549-2、NBR 16149:2013、UL1741
Power grid detection IEC/EN 62109-1、 IEC/EN 62109-2、 IEC 62116、IEEE 1547
Certificate CE,ETL,Patented technology

Detailed

Dongguan-Kaideng-Energy-Technology-Co-Ltd-WVC-1600-Micro-Inverter-
fig-5

System diagram

Dongguan-Kaideng-Energy-Technology-Co-Ltd-WVC-1600-Micro-Inverter-
fig-6

With N wire connection (Single phase 120/230V)

No N wire connection(Single phase 120V)

Note:
You can purchase a professionally customized AC bus with a T-type connector. Use this AC bus as the AC bus for each branch. Connect it hand in hand to form a modular micro- inver ter branch wiring system.

LED indicator function of micro inverter

  1. Red light keeps on ——-The equipment enters the preparatory working state;
  2. Red light flashes——- The device enters the delayed start-up stale;
  3. Blue light flashes quickly —–MPPT maximum power point search status;
  4. Blue light keeps on-, ——–<v,PPT maximum power point locked state;
  5. Blue light turns to red light for a long time—-
    • Island protection;
    • Frequency protection; c)Fault;
    • Software shutdown;
    • AC voltage over-voltage protection;
    • DC voltage over- voltage protection

Normal working indicator flashing process

Connect the micro-inverter correctly to the AC and DC terminals and then power on:

  • The red light keeps on for 3 seconds
  • the red light flashes for 30 seconds
  • the blue light flashes quickly (MPPT maximum power point search)
  • the blue light keeps on, (MPPT lock).

DOWNLOAD Cloud Intelligence APP

Please use the QR code to scan and install the “Cloud Intelligence” client application,System version: Android 5.0, !OS 9 and above

Dongguan-Kaideng-Energy-Technology-Co-Ltd-WVC-1600-Micro-Inverter-
fig-9

Note

Please strictly observe the following installation conditions

  • Connect the communication antenna on the inverter;
  •  Put the inverter in a place with good Wifi signal;
  • The connected Wi-Fi network needs to be in 2.4G mode;
  • Please reset the inverter for the first use;

Reset
Long press the reset button, when the LED indicator lights up again and turns into a “blue light”Release the reset button after the status is displayed for a long time, and the inverter will automatically complete the reset.

Add Device
Open the intelligent monitoring software “Cloud Intelligence” APP to log inAccount, click the “+” icon in the upper right corner to start addingEquipment program;*lf there is a device under the current account, click on the device Icon to enter the details page)

Entry equipment
When the smart APP changes to the QR code scanning state, scan the QR code label on the inverter body. At this time, the APP will automatically collect the inverter code and automatically jump to the Wi-Fi connection page, enter Click Next af ter the current Wi-Fi password;

Disribution network
Connect the inverter to the power supply as required, and quickly press the “Reset” button. At this time, the “LED” indicator will change to flashing blue and red alternately. At this time, the inverter enters the standby state of the distribution network;

Initialization
When the inverter is in standby mode, return to the mobile phone APP to initialize the device operation page, check the “I have completed the above operations” below and click the “Start Connection” button. At this time, the page will jump to the signal search page. The LED indicator on the converter changes from red and blue alternately flashing state to “blue” long-bright display state when the network distribution is completed. The page will automatically jump to the system completion confirmation page, please click “Finish”.

Inverter Control
Click the “Settings” button in the upper right corner of the system details page. In the settings page, you can adjust the inverter’s output power, timing, remote start and stop, etc. according to actual needs.

Remarks

  1. When multiple inverters need to be added, theln the English state, “,” comma separated and ended. Such as: 60001234, 6000E312,
  2. Each Modem can monitor 60 inverters at the same time;3. A total of 2 lists, each list can be filled with 30 inverter codes;

Features

Smart APP can realize real-time data transmission with the cooperation of Alibaba Cloud loTThrough graphs and graphic displays in time, users can understand the operation of the power station. The user can monitor the operation and adjust the output power function of the system.

Dongguan-Kaideng-Energy-Technology-Co-Ltd-WVC-1600-Micro-Inverter-
fig-15

INTELLIGENT lot MONITORING MODEM

Number of data collectors per Modem Built-in WiFi loT data terminal Can be used on any smart device {Android/iOS)

  • C0-2 induced environmental analysis
  • Daily and total energy generation in kWh
  • Actual DC input voltage, current and power
  • Actual AC output voltage, current and power
  • Inverter temperature
  • Historical (daily, weekly, monthly) power curve
  • Power losses due to weather induced effects
  • Optional limitation of power output
  • Online switch for the inverter start stop

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals