The DFH 22 is an electric heating device manufactured by Glen Dimplex Deutschland GmbH. It has two heat settings (800 W and 2000 W) and can also be used as a cold air fan. The device has a mechanical room temperature control and is equipped with a safety switch that turns it off if it tips over. It is designed for use in homes and small offices and should not be used in rooms where flammable substances are present.

Product Usage Instructions

Before using the DFH 22, carefully read and follow the instructions provided in the user manual to ensure safe operation of the device.

Installation

Place the device on a flat and stable surface, at least 100 mm away from any walls or other objects. Make sure the device cannot be touched by a person in the bathtub or under the shower.

ATTENTION :
Do not install the device directly below a wall socket.

  • The fan heater may only be used as shown, i.e. on a horizontal, even surface. Use on deep-pile carpets is not permitted. Minimum clearance in the air outlet area: 750 mm.

Electrical Connection

Connect the device to a grounded 230-240 V~ 50 Hz power outlet. If the power cord is damaged, it must be replaced by a qualified technician to avoid hazards.
Only connect the device to the AC voltage power supply as specified on the type plate.

Operating Instructions

  • To turn on the device, turn the mode switch to either of the two heating settings (800 W or 2000 W).
  • To use the device as a cold air fan, turn the mode switch to the “cold” setting.
  • To adjust the temperature, turn the thermostat knob to the desired temperature.
  • If the device tips over, it will automatically turn off due to its safety switch.

Maintenance

Regularly clean the device with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water. If the device requires repair, contact a qualified technician or the manufacturer.
The device must be disconnected from the mains and allowed to cool down before maintenance. Clean the outside of the device using a soft, damp cloth. Do not use scouring powder or furniture polish as this may damage the surface. Dust which gathers inside the device can be removed from the outside using a vacuum cleaner.

Safety Instructions

  • Keep the device away from children under 3 years old.
  • Children between the ages of 3 and 8 may use the device if they are supervised or have been instructed on its safe use.
  • Do not cover the device with any objects.
  • Do not use the device in rooms where flammable substances are present.

This product is only suitable for well-insulated rooms or for occasional use.

 Notes for the user

NOTE
Dear customer,
Keep these instructions in a safe place and pass them on to any future owners. For safe operation, the device may only be operated in accordance with the information in these operating instructions. Please carefully follow all information provided in these instructions.

ATTENTION:
This device can be used by children aged 8 and over and by persons with limited physical, sensory or mental aptitude, providing they are supervised or have been instructed in the safe use of the device and understand the associated potential dangers. Children must not play with the device. Cleaning and user maintenance may not be carried out by children without supervision.

  • Children younger than 3 years of age must be kept away unless they are supervised constantly.
  • Children between the ages of 3 and 8 may switch the device on and off if they are supervised or have been instructed in the safe use of the device and have understood the resulting dangers, providing that the device is positioned or installed in its normal place of use.
  • Children between the ages of 3 and 8 may not switch on the device, clean the device or carry out maintenance.
  • The heating device carries the symbol shown on the right, which indicates that the heating device must under no circumstances be covered with any objects.
  • Some parts of the device can get very hot and cause burns. Particular caution must be taken with children or vulnerable people.
  • Do not operate the heating device in rooms where highly flammable substances are used (e.g. solvents).
  • Install the device in such a manner that it cannot be touched by a person in the bath-tub or under the shower.
  • If the supply cord is damaged, it must be replaced by the manufacturer, a service agent or similarly qualified persons in order to avoid a hazard.
  • To prevent a hazard due to the protection temperature limiter being reset unintentionally, the device must not be supplied by an external switching facility, such as a time switch, or connected to an electric circuit that is switched on and off regularly by a device.
  • Do not use the device if it is visibly damaged or if the device has been dropped.
  • Do not operate the device near curtains, drapes and other flammable materials!
  • Do not lay the connecting cable across the device. Never commission the device if the device or power cable are damaged. Danger to life!
  • The socket-outlet must be accessible at all times to enable the mains plug to be disconnected as quickly as possible!
  • Do not use extension cables to connect the heating device, as this could result in fire in the event of overheating!

NOTE
Repairs and corrective measures must only be carried out by a qualified technician.

  • Use device for room heating within enclosed rooms only.
  • Disconnect the power supply in the event of fault or when device is not used for an extended period of time.

Operation

  1. Thermostat control rotary knob
  2. Indicator lamp
  3. Operating mode rotary knob
  4. Safety toggle switch
  5. Air outlet

Operating mode rotary knob
DFH 22 Fan Heater 03 Thermostat control rotary knob
The room temperature is regulated using the continuously adjustable thermostat. Turn the thermostat control rotary knob to the right stop at the start (maximum). When the desired room temperature is reached, turn the thermostat control rotary knob slowly to the left until the device switches off. The device now switches on and off automatically to maintain the desired room temperature. There may be an audible click during this process.
If the thermostat rotary knob is set to the lowest setting i.e. to the extreme left, the thermostat switches the heating device on at an ambient temperature of approx. 5 °C. Using the operating mode rotary knob, two heating levels and a cold air level can be selected. In the cold air fan operation, turn the thermostat rotary knob to the right stop (maximum). The device is equipped with a safety toggle switch. The device switches off automatically if it is not in its correct position.

Overload protector

For your safety, the heating device is equipped with an overload protector. If the permissible temperature is exceeded, the heating device switches off automatically. In this case, the power supply to the heating device should be disconnected (switch off the fuse) to allow the device to cool down sufficiently. Before recommissioning the device, resolve the reasons (e.g. air grille positioned incorrectly or covered) for the overload protector being triggered. If the overload protector is repeatedly triggered, decommission the device and contact your electronics retailer.

Warranty

This product is supplied with a two-year warranty according to our terms of guarantee.

Recycling

Do not dispose of the device with general household waste. Take the device to the available collection points at the end of its service life.

Technical data

Order code Unit DFH 22
**** Connection voltage 1/N/PE

230-240 V ~
50 Hz
Power consumption| kW| 2.0
** Protection class| II, without protective conductor
Degree of protection| IP21
Heating levels| 2
Heat output
Nominal heat output| Pnom| kW| 2.0
Minimum heat output
(guide value)| Pmin| kW| 0.8
Maximum continuous heat output| Pmax,c| kW| 2.0
Additional power consumption
At nominal heat output| Elmax| kW| 0.0
At minimum heat output| Elmin| kW| 0.0
In standby mode| elSB| kW| 0.0
Type of heat output/room temperature control**
Mechanical room temperature control| °C| 5 – 35
Dimensions W x H x D| mm| 190 x 230 x 125
Weight| kg| 1.12

Glen Dimplex Deutschland GmbH
Am Goldenen Feld 18
95326 Kulmbach
Phone: +49 9221 709 700
Fax: +49 9221 709 701
Email: elektroheizung@dimplex.de