Erbauer ECSG3640-Li Battery Chainsaw Instruction Manual

June 10, 2024
Erbauer

Erbauer ECSG3640-Li Battery Chainsaw

Erbauer-ECSG3640-Li-Battery-Chainsaw-product

General Safety Symbols

This symbol alerts you to a wide range of potential dangers.

  • This symbol advises you of danger from electricity or electric shock.
  • This symbol indicates that a hot surface may be present.
  • This symbol marks information that is particularly important.
  • This symbol indicates an alternating current.
  • These symbols on the Power Switch/Circuit Breaker indicate that they place the main power supply ON/OFF.
  • This symbol on the Power Key indicates that it places the unit in a standby mode. It DOES NOT fully disconnect the unit from the power supply.
  • Read all instructions pertaining to safety, set-up, and operation. Proper operation and maintenance is the user’s responsibility.

Safety Recommendations

WARNING:

  • This Immersion Circulator is suitable for use with Class I non-flammable fluids only.
  • Be aware of chemical hazards that may be associated with the bath fluid used as well as those contained in the material safety data sheet.
  • Use only recommended bath fluids, see Technical Information in the instruction manual for recommended fluids. Always use fluids that satisfy safety, health, and equipment compatibility requirements.
  • Use only non-acid bath fluids.

WARNING:

  • Always connect the power cord on this Circulator to a grounded (3-prong) power outlet. Make certain that the outlet is the same voltage and frequency as your unit. The use of an extension cord is not recommended.
  • Never operate the Circulator with a damaged power cord.
  • Always turn the Circulator OFF and disconnect main power before performing any maintenance or service.

WARNING:

  • Never operate the Circulator without bath fluid in the reservoir. Periodically check the reservoir to ensure that the liquid depth is within acceptable levels. Always refill the reservoir using the same bath fluid type that is already in the reservoir. Bath oil must not contain any water contaminants and should be preheated to the actual bath temperature before adding as there is an explosion hazard at high temperatures.
  • Always drain all fluid from the reservoir before moving or lifting your Circulator. Be sure to follow your organization’s procedures and practices regarding the safe lifting and relocation of heavy objects.
  • WARNING: It is the user’s responsibility to properly decontaminate the unit in the event hazardous materials are spilled on exterior or interior surfaces. Consult manufacturer if there is any doubt regarding the compatibility of decontamination or cleaning agents.
  • WARNING: Read the safety data sheet for the bath fluid being used before filling the reservoir. Always use fluids that satisfy safety, health, and equipment compatibility requirements.
  • WARNING: The use of an extension cord is not recommended.

WARNING

  • Always allow the bath fluid to cool to ambient temperature before draining.
  • The reservoir cover, top deck, and/or external pump connections may become hot with continuous use. Exercise caution when touching these parts.
  • Always keep within the 85°C maximum operating temperature limit if using a polycarbonate tank.

Circulating Bath Quick Start Guide

This guide offers the quickest way to install and begin operating your Circulating Bath. It provides on!

  1. Fill reservoir with fluid.
  2. Connect to grounded electrical power of the correct voltage.
  3. Turn the Mains power ON (for Refrigerated units).
  4. Turn the Controller power ON.
  5. Adjust the Safety Set temperature.
    • The safety setting default is approximately 90°C.
    • Remove the cover plate to expose Safety Thermostat.
    • Using a small flat-blade screwdriver, rotate the Safety Thermostat clockwise until it stops.
    • Press the key. SET will begin flashing.
    • Continue pressing the keys until the desired Safety Set temperature appears on the display.
    • Once the bath temperature has stabilized, slowly rotate the Safety Thermostat counter-clockwise until you hear a soft “click”; the OVERTEMP or LOW FLUID alarm symbol will appear on the display approximately 5-10 seconds later. At this point, the heater will also turn OFF.
    • Slowly rotate the Safety Set temperature clockwise until the alarm symbol extinguishes. The heater should also turn back ON.
    • Replace cover plate
  6. Enter temperature set point.
    • To change, press the key. The word “SET” will begin flashing. Continue holding or repeatedly press until the desired set point temperature is displayed.
    • To accept, press or allow the LCD to return to the main operational display.

References