EMPIRE VFP32FP30LN-1 Vail Vent Free Gas Fireplaces Installation Guide
- July 8, 2024
- Empire
Table of Contents
- VFP32FP30LN-1 Vail Vent Free Gas Fireplaces
- IMPORTANT SAFETY INFORMATION
- SAFETY INFORMATION FOR USERS OF LP-GAS
- INTRODUCTION
- SPECIFICATIONS
- PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR
- GAS SUPPLY
- CLEARANCES
- COMBUSTIBLE MATERIALS
- FIREPLACE DIMENSIONS
- INSTALLING HOOD AND TRIM KIT
- PLANNING INSTALLATION
- FIREPLACE FRAMING AND INSTALLATION
- PLACEMENT OF GLOWING EMBERS AND LAVA ROCK
- OPERATION INSTRUCTIONS/FLAME APPEARANCE
- VFP(32,36)FP(30,31) LIGHTING INSTRUCTIONS
- VFP(32,36)FP(20,21) LIGHTING INSTRUCTIONS
- PILOT FLAME CHARACTERISTICS
- WIRING
- MAINTENANCE
- TROUBLESHOOTING
- PARTS LIST
- PARTS VIEW
- HOW TO ORDER REPAIR PARTS
- OPTIONAL VARIABLE SPEED BLOWER INSTALLATION INSTRUCTIONS
- JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
- OPTIONAL BRICK LINER INSTALLATION INSTRUCTIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EMPIRE VFP32FP30LN-1
**Owner’s Manual
**
VFP32FP30LN-1 Vail Vent Free Gas Fireplaces
This Owner’s Manual is provided and hosted by Appliance Factory Parts.
Appliance Factory Parts
Experts in BBQ, Humidifier, & Appliance Parts
1-800-955-7075
Repair Your Grill: Shop Replacement Parts for 24,880 Models (appliancefactoryparts.com)
Shop genuine replacement parts for EMPIRE VFP32FP30LN-1
Find Your EMPIRE Fireplace Parts – Select From 642
Models
——– Manual continues below ——–
INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL
The Vail Vent-Free Gas Fireplaces
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
UNVENTED
GAS FIREPLACE
MODELS
VFP32FP(20,21)L(N,P)-1
VFP32FP(30,31)L(N,P)-1
VFP36FP(20,21)L(N,P)-1
VFP36FP(30,31)L(N,P)-1
EFFECTIVE DATE
MARCH 2006
We suggest that our gas hearth products be installed and serviced by profes- sionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as NFI Gas Specialists.
This appliance may be installed in an aftermarket, permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to page 7.
WARNING: If not installed, operated and maintained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion. An unvented room heater
produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’s
(.3KW’s) of gas input per hour. Refer to page 7.
IMPORTANT SAFETY INFORMATION
- An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom
- An unvented room heater having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom or bathroom.
- Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
- Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
- Young children should be carefully supervised when they are in the same room with the appliance.
- Do not place clothing or other flammable material on or near the appliance.
- Installation and repair should be done by a QUALIFIED SERVICE PERSON. This appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
- DO NOT use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
- You must operate heater with fireplace screen closed in place. Do not close glass doors while operating heater.
- Do not place trash, logs or other articles on the log set during operation.
- During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These bonding agents are not harmful but may produce annoying smoke and smells as they are burned off during initial operation of the appliance. This is a normal temporary occurrence. A window should be opened during the initial bake out period.
- Correct installation of the ceramic fiber logs, proper location of the heater and annual cleaning are necessary to avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the fireplace. See instructions for proper installation.
- WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.
- WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.
- WARNING! This fireplace needs fresh air for ventilation to run properly. This fireplace has an ODS (oxygen depletion sensor) which will shut down the heater if adequate fresh air is not available. See troubleshooting section in the instructions.
- Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
- WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.
WARNING
When used without adequate combustion and ventilation air, heater may give off
CARBON MONOXIDE, an odorless, poisonous gas.
Do not install heater until all necessary provisions are made for combustion
and ventilation air. Consult the written instructions provided with the heater
for information concerning combustion and ventilation air. In the absence of
instructions, refer to the National Fuel Gas Code, ANSI Z223.1, Section 5.3 or
applicable local codes.
This heater is equipped with a PILOT LIGHT SAFETY SYSTEM designed to turn off the heater if not enough fresh air is available.
DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM!
If heater shuts off, do not relight until you provide fresh air. If heater keeps shutting off, have it serviced. Keep burner and control compartment clean.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH.
Early signs of carbon monoxide poisoning resemble the flu, with headache,
dizziness and/or nausea. If you have these signs, heater may not be working
properly. Get fresh air at once! Have heater serviced.
Some people — pregnant women, persons with heart or lung disease, anemia,
those under the influence of alcohol , those at high altitudes — are more
affected by carbon monoxide than others.
The pilot light safety system senses the depletion of oxygen at its location.
If this heater is installed in a structure having a high vertical dimension,
the possibility exists that the oxygen supply at the higher levels will be
less than that at the heater. In this type of application, a fan to circulate
the structure air will minimize this effect. The use of this fan will also
improve the comfort level in the structure. When a fan is used to circulate
air, it should be located so that the air flow is not directed at the burner.
SAFETY INFORMATION FOR USERS OF LP-GAS
Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now, then review them point by point with the members of your household. Someday when there may not be a minute to lose, everyone’s safety will depend on knowing exactly what to do. If, after reading the following information, you feel you still need more information, please contact your gas supplier.
LP-GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas because of the
odorant put in the LP-Gas. That’s your signal to go into immediate action!
- Do not operate electric switches, light matches, use your phone. Do not do anything that could ignite the gas.
- Get everyone out of the building, vehicle, trailer, or area. Do that IMMEDIATELY.
- Close all gas tank or cylinder supply valves.
- LP-Gas is heavier than air and may settle in low areas such as basements. When you have reason to suspect a gas leak, keep out of basements and other low areas. Stay out until firefighters declare them to be safe.
- Use your neighbor’s phone and call a trained LP-Gas service person and the fire department. Even though you may not continue to smell gas, do not turn on the gas again. Do not re-enter the building, vehicle, trailer, or area.
- Finally, let the service man and firefighters check for escaped gas. Have them air out the area before you return. Properly trained LP-Gas service people should repair the leak, then check and relight the gas appliance for you.
NO ODOR DETECTED – ODOR FADE
Some people cannot smell well. Some people cannot smell the odor of the
chemical put into the gas. You must find out if you can smell the odorant in
propane. Smoking can decrease your ability to smell. Being around an odor for
a time can affect your sensitivity or ability to detect that odor. Sometimes
other odors in the area mask the gas odor. People may not smell the gas odor
or their minds are on something else. Thinking about smelling a gas odor can
make it easier to smell.
The odorant in LP-gas is colorless, and it can fade under some circumstances.
For example, if there is an underground leak, the movement of the gas through
soil can filter the odorant. Odorants in LP-Gas also are subject to oxidation.
This fading can occur if there is rust inside the storage tank or in iron gas
pipes.
The odorant in escaped gas can adsorb or absorb onto or into walls, masonry
and other materials and fabrics in a room.
That will take some of the odorant out of the gas, reducing its odor
intensity.
LP-Gas may stratify in a closed area, and the odor intensity could vary at
different levels. Since it is heavier than air, there may be more odor at
lower levels. Always be sensitive to the slightest gas odor. If you detect any
odor, treat it as a serious leak. Immediately go into action as instructed
earlier.
SOME POINTS TO REMEMBER
- Learn to recognize the odor of LP-gas. Your local LP-Gas Dealer can give you a “Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP-Gas has a weak or abnormal odor, call your LP-Gas Dealer.
- If you are not qualified, do not light pilot lights, perform service, or make adjustments to appliances on the LP-Gas system. If you are qualified, consciously think about the odor of LP-Gas prior to and while lighting pilot lights or performing service or making adjustments.
- Sometimes a basement or a closed-up house has a musty smell that can cover up the LP-Gas odor. Do not try to light pilot lights, perform service, or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP-Gas.
- Odor fade, due to oxidation by rust or adsorption on walls of new cylinders and tanks, is possible. Therefore, people should be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in new tanks, or reinstalled old tanks, if they are filled and allowed to set too long before refilling. Cylinders and tanks which have been out of service for a time may develop internal rust which will cause odor fade. If such conditions are suspected to exist, a periodic sniff test of the gas is advisable. If you have any question about the gas odor, call your LP-gas dealer. A periodic sniff test of the LP-gas is a good safety measure under any condition.
- If, at any time, you do not smell the LP-Gas odorant and you think you should, assume you have a leak. Then take the same immediate action recommended above for the occasion when you do detect the odorized LP-Gas.
- If you experience a complete “gas out,” (the container is under no vapor pressure), turn the tank valve off immediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices. If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank. Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty.
INTRODUCTION
Instructions to Installer
- Installer must leave instruction manual with owner after installation.
- Installer must have owner fill out and mail warranty card supplied with unvented room heater.
- Installer should show owner how to start and operate unvented room heater.
Always consult your local Building Department regarding regulations, codes or
ordinances which apply to the installation of an unvented room heater.
This appliance may be installed in an aftermarket manufactured (mobile) home,
where not prohibited by state or local codes.
Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases.
WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS.
Improper installation or use of the heater can cause serious injury or death
from fire, burns, explosion or carbon monoxide poisoning.
This series is design certified in accordance with American National Standard Z21.11.2 by the Canadian Standards Association Laboratories as an Unvented Room Heater and should be installed according to these instructions.
Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.
VFP(32,36)FP(30,31)L Only
750 Millivolt System
When you ignite the pilot, the thermocouple produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON. Allow your pilot flame to operate an additional one (1) to two (2) minutes before you turn the gas control knob from the PILOT position to the ON position. This time period allows the millivolts (electrical energy) to build- up to a sufficient level allowing the gas control to operate properly.
Important
All correspondence should refer to complete Model Number, Serial Number and
type of gas.
Attention: During initial use of ceramic log you will detect an odor as the
ceramic log is cured. Also, during the curing process the ceramic log will
burn with a yellow flame.
Notice: During initial firing of this unit, its paint will bake out, and
smoke will occur. To prevent triggering of smoke alarms, ventilate the room in
which the unit is installed.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material other than wood flooring the appliance shall be installed
on a metal or wood panel extending the full width and depth of the appliance.
The base referred to above does not mean the fire-proof base as used on wood
stoves. The protection is for rugs that are extremely thick and light colored
tile.
Solid-fuels shall not be burned in a masonry or UL 127 factorybuilt fireplace in which an unvented room heater is installed.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or
accessories and repair and servicing of equipment shall be performed only by a
qualified agency. The term “qualified agency” means any individual, firm,
corporation or company which either in person or through a representative is
engaged in and is responsible for (a) the installation or replacement of gas
piping or (b) the connection, installation, repair or servicing of equipment,
who is experienced in such work, familiar with all precautions required and
has complied with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by a licensed plumber or
gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental room heaters
shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
The installation must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1.
Available from the American National Standards Institute, Inc. 1430 Broadway, New York, N.Y. 10018.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be reduced at
the rate of 4 percent for each 1,000 feet (305m) above sea level. Contact the
manufacturer or your gas company before changing spud/orifice size.
Well Head Gas Installations
Some natural gas utilities use “well head” gas. This may affect the Btu output
of the unit. Contact the gas company for the heating value. Contact the
manufacturer or your gas company before changing spud/orifice size.
WARNING: This appliance is equipped for (natural gas or propane) gas.
Field conversion is not permitted.
SPECIFICATIONS
Model | VFP32FP | VFP36FP |
---|---|---|
Input Maximum | 32,000 | 36,000 |
Minimum | 22,000 | 25,000 |
Minimum Firebox Opening
Height without standoff| 32 3/4″| 34 3/4″
Width| 34”| 39”
Depth| 17 3/8″| 17 3/8”
Gas Inlet| 3/8”| 3/8”
Accessories
EK-1| Embers Kit
PE-20| Platinum Embers
FBB4*| Variable Speed Automatic Blower
VPP32A| VFP32FP — Ceramic Aged Brick Liner
VPP36A| VFP36FP — Ceramic Aged Brick Liner
Accessories For VFP(32,36)FP(30,31) Only
FRBC| Battery Operated Remote Control
FRBTC| Battery Operated Remote Control w/Thermostat
FREC| Electric Remote Control
FWS| Wall Switch
TMV| Wall Thermostat, Millivolt – Reed Switch
TRW| Remote Wall Thermostat
*FBB4 is standard (installed) on VFP(32,36)FP(21,31)
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion. An unvented room heater
produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’s
(.3KW’s) of gas input per hour.
Unvented room heaters are recommended as supplemental heat (a room) rather
than a primary heat source (an entire house). In most supplemental heat
applications, the water vapor does not create a problem. In most applications,
the water vapor enhances the low humidity atmosphere experienced during cold
weather.
The following steps will help insure that water vapor does not become a problem.
- Be sure the heater is sized properly for the application, including ample combustion air and circulation air.
- If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.
- Do not use an unvented room heater as the primary heat source.
PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR
This heater shall not be installed in a confined space or unusually tight
construction unless provisions are provided for adequate combustion and
ventilation air.
The National Fuel Gas Code, ANSI Z223.1 defines a confined space as a space
whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m³ per kw)
of the aggregate input rating of all appliances installed in that space and an
unconfined space as a space whose volume is not less than 50 cubic feet per
1,000 Btu per hour (4.8m³ per kw) of the aggregate input rating of all
appliances installed in that space. Rooms communicating directly with the
space in which the appliances are installed, through openings not furnished
with doors, are considered a part of the unconfined space.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for
combustion and ventilation. However, in buildings of unusually tight
construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. Walls and ceilings exposed to the outside atmosphere have a continuous
water vapor retarder with a rating of one perm or less with openings gasketed
or sealed, and
b. Weather-stripping has been added on openable windows and doors, and
c. Caulking or sealants are applied to areas such as joints around window and
door frames, between sole plates and floors, between wall-ceiling joints,
between wall panels, at penetrations for plumbing, electrical, and gas lines,
and at other openings.
If your home meets all of the three criteria above, you must provide
additional fresh air. See “Ventilation Air From Outdoors,” page 8.
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any
adjoining rooms with doorless passageways or ventilation grills between the
rooms.
-
Determine the volume of the space (length x width x height).
Length x Width x Height = ———- cu. ft. (volume of space)
Example: Space size 16 ft. (length) x 10 ft. (width) x 8 ft. (ceiling height) = 1,280 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. -
Divide the space volume by 50 cubic feet to determine the maximum BTU/Hr the space can support.
———- (volume of space) ÷ 50 cu. ft. = (maximum BTU/Hr the space can support)
Example: 1,280 cu. ft. (volume of space) ÷ 50 cu. ft. = 25.6 or 25,600 (maximum BTU/Hr the space can support) -
Add the BTU/Hr of all fuel burning appliances in the space.
Vent-free heater ———- BTU/Hr
Gas water heater ———- BTU/Hr
Gas furnace ———- BTU/Hr
Vented gas heater ———- BTU/Hr
Gas fireplace logs ———- BTU/Hr
Other gas appliances + B———- TU/Hr
Total = ———- BTU/Hr
Example: Vented gas heater ———- 20,000 ———- BTU/Hr
Vent-free heater + ———- 18,000 ———- BTU/Hr
Total = ———- 38,000 ———- BTU/Hr
Do not include direct-vent gas appliances. Direct vent draws combustion air from the outdoors and vents to the outdoors. -
Compare the maximum BTU/Hr the space can support with the actual amount of BTU/Hr used.
———- BTU/Hr (maximum the space can support)
———- BTU/Hr (actual amount of BTU/Hr used)
Example:
25,600 BTU/Hr (maximum the space can support)
38,000 BTU/Hr (actual amount of BTU/Hr used)
Warning: If the area in which the heater may be operated is smaller than
that defined as an unconfined space or if the building is of unusually tight
construction, provide adequate combustion and ventilation air by one of the
methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3 or
applicable local codes.
The space in the above example is a confined space because the actual BTU/Hr
used is more than the maximum BTU/HR the space can support. You must provide
additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space
provides an unconfined space, remove door to adjoining room or add ventilation
grills between rooms. See Ventilation Air From Inside Building.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors.
C. Install a lower BTU/Hr heater, if lower BTU/Hr size makes room unconfined.
If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
WARNING: You must provide additional ventilation air in a confined space.
Ventilation Air
Ventilation Air From Inside Building (Figure 1)
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12″ of the ceiling and one within 12″ of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 1). You can also remove door into adjoining room (see option 3, Figure 1). Each ventilation grill or opening shall have a minimum free area of one square inch per 1,000 BTUH of the total input rating of the gas equipment in the confined space.
WARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.
Ventilation Air From Outdoors (Figure 2)
Provide extra fresh air by using ventilation grills or ducts. You must provide
two permanent openings: one within 12″ of the ceiling and one with 12″ of the
floor. Connect these items directly to the outdoors or spaces open to the
outdoors. These spaces include attics and crawl spaces. In most cases for
direct communication with the outdoors or direct communication through a
vertical duct a free area opening of one square inch per 4,000 BTU/Hr of
heater input rating for each grill. If a horizontal duct is used, a grill free
area or duct opening shall have a free area opening of one square inch per
2,000 BTU/Hr for each grill. Follow the National Fuel Code NFPA 54/ANSI
Z223.1, Section 5.3 Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet or outlet air into attic if
attic has a thermostat-controlled power vent. Heated air entering the attic
will activate the power vent.
GAS SUPPLY
Check all local codes for requirements, especially for the size and type of gas supply line required.
Recommended Gas Pipe Diameter
Pipe Length| Schedule 40 Pipe Inside Diameter| Tubing, Type L Outside Diameter
| Nat.| L.P.| Nat.| L.P.
0-10 feet
0-3 meters| 1/2”
12.7mm| 3/8”
9.5mm| 1/2”
12.7mm| 3/8”
9.5mm
10-40 feet
4-12 meters| 1/2”
12.7mm| 1/2”
12.7mm| 5/8”
15.9mm| 1/2”
12.7mm
40-100 feet
13-30 meters| 1/2”
12.7mm| 1/2”
12.7mm| 3/4”
19mm| 1/2”
12.7mm
100-150 feet
31-46 meters| 3/4”
19mm| 1/2”
12.7mm| 7/8”
22.2mm| 3/4”
19mm
Note: Never use plastic pipe. Check to confirm whether your local codes
allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes, it is always
best to consult your local authority and installation code.
Installing a New Main Gas Cock
Each appliance should have its own manual gas cock.
A manual main gas cock should be located in the vicinity of the unit. Where
none exists, or where its size or location is not adequate, contact your local
authorized installer for installation or relocation.
Compounds used on threaded joints of gas piping shall be resistant to the
action of liquefied petroleum gases. The gas lines must be checked for leaks by
the installer. This should be done with a soap solution watching for bubbles
on all exposed connections, and if unexposed, a pressure test should be made.
Never use an exposed flame to check for leaks. Appliance must be disconnected
from piping at inlet of control valve and pipe capped or plugged for pressure
test. Never pressure test with appliance connected; control valve will sustain
damage!
A gas valve and ground joint union should be installed in the gas line
upstream of the gas control to aid in servicing. It is required by the
National Fuel Gas Code that a drip line be installed near the gas inlet. This
should consist of a vertical length of pipe tee connected into the gas line
that is capped on the bottom in which condensation and foreign particles may
collect.
The use of the following gas connectors is recommended:
— ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and Fittings
— ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-Metal
Construction
The above connectors may be used if acceptable by the authority having
jurisdiction The state of Massachusetts requires that a flexible appliance
connector cannot exceed three feet in length.
Checking Manifold Pressure
VFP(32,36)FP(30,31)LN (Natural gas) will have a manifold pressure of
approximately 3.5″ w.c. (.871kPa) for maximum input or 1.7″ w.c. (.423kPa) for
minimum input at the pressure regulator outlet with the inlet pressure to the
pressure regulator from a minimum of 4.5″ w.c. (1.120kPa) for the purpose of
input adjustment to a maximum of 10.5″ w.c. (2.614kPa). VFP(32,36)FP(20,21)LN
(Natural gas) will have a manifold pressure of approximately 6.0″ w.c.
(1.49kPa) at the pressure regulator outlet with the inlet pressure to the
pressure regulator from a minimum of 7.0″ w.c. (1.74kPa) for the purpose of
input adjustment to a maximum of 10.5″ w.c. (2.615kPa). VFP(32,36)FP(30,31)LP
(Propane gas) will have a manifold pressure approximately 10.0″w.c. (2.49kPa)
for maximum input or 4.9″w.c. (1.220kPa) for minimum input at the pressure
regulator outlet with the inlet pressure to the pressure regulator from a
minimum of 11.0″w.c. (2.739kPa) for the purpose of input adjustment to a
maximum of 13.0″w.c. (3.237kPa).
VFP(32,36)FP(20,21)LP (Propane gas) will have a manifold pressure
approximately 10.0″w.c. (2.49kPa) at the pressure regulator outlet with the
inlet pressure to the pressure regulator from a minimum of 11.0″w.c.
(2.739kPa) for the purpose of input adjustment to a maximum of 13.0″w.c.
(3.237kPa).
A test gage connection is located downstream of the gas appliance pressure
regulator for measuring gas pressure. The connection is a 1/8 inch (3mm)
N.P.T. plugged tapping.
VFP(32,36)FP(30,31) Millivolt Control
The valve regulator controls the burner pressure which should be checked at
the pressure test point. Turn captured screw counter clockwise 2 or 3 turns
and then place tubing to pressure gauge over test point (Use test point “A”
closest to control knob). After taking pressure reading, be sure and turn
captured screw clockwise firmly to re-seal. Do not over torque. Check for gas
leaks.
CLEARANCES
Minimum Wall and Ceiling Clearances (Figure 4)
Sidewall Clearances: The clearance from the inside of the fireplace to any
combustible wall should not be less than 2″.
Fireplace Side and Back Clearances: The fireplace outer casing sides and back
have zero clearance to combustibles.
Ceiling Clearances: The ceiling height should not be less than 36″ from the
top of the hood.
Mantel Clearances: Vent free fireplace models must use the hood supplied with
the fireplace. If a combustible mantel is installed, it must meet the clearance
requirements detailed above.
Mantel Clearances (Figure 5)
COMBUSTIBLE MATERIALS
Do not attach combustible material to the mantel of your fireplace.
This is a fire hazard.
No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. This is a heating appliance. The flow of heat can ignite combustibles.
FIREPLACE DIMENSIONS
| VFP32FP| VFP36FP
---|---|---
A| 34″| 39″
B| 29″| 34″
C| 17 3/8″| 17 3/8″
D| 31″| 36″
E| 22 7/8″| 24 7/8″
F| 32 3/4″| 34 3/4″
G| 44 7/16″| 48″
H| 44 7/16″| 48″
I| 55 7/8″| 60 7/8″
J| 35 3/4″| 37 3/4″
INSTALLING HOOD AND TRIM KIT
A black hood and trim kit is furnished with each model VFP(32,36)FP fireplace.
The hood MUST be installed before the fireplace is used. Failure to do so may
create a possible fire hazard.
Attention: The hood is located behind top louver during shipment of
fireplace. Remove top louver for access to hood.
The trim kit is used to finish the fireplace. The trim kit is used in place of brick, marble or other finishing material.
- To remove top louver, lift louver and pull forward.
- Open bottom louver.
- Insert trim side left and trim side right into the fireplace. Attach (4) Phillips screws through bottom and top clearance hole on trim side left and trim side right and into fireplace.
- Insert flange on fireplace hood on the top of the firebox in the gap between the louver and firebox top.
- Attach fireplace hood to fireplace with (3) Phillips screws. See Figure 9.
- Insert the trim top into the top, interior of the fireplace. Position the (3) clearance holes in the trim top downward. Align the (3) clearance holes with the (3) screw holes in the top, interior of the fireplace. When the trim top contacts the wall surface secure the trim top to the fireplace with (3) Phillips screws.
- Close bottom louver.
- Replace top louver
Finishing
All joints (top, bottom and sides), where the wall or decorative facing
material meets the fireplace surround must be completely sealed with a non-
combustible material.
Hearth extensions are recommended, not a requirement for these gas fireplaces.
Do not cover the louvers at any time with finishing materials. This could cause
this product to overheat and cause a fire.
PLANNING INSTALLATION
In planning the installation for the fireplace, it is necessary to determine
where the unit is to be installed and whether optional accessories are
desired. Gas supply piping should also be planned at this time.
The fireplace can be mounted on any of these surfaces:
- A flat hard combustible or non-combustible surface.
- A raised platform of combustible or non-combustible material.
- Four (4) corners of the fireplace so contact is made on all four perimeter edges on the bottom of the unit. (Example: Four (4) concrete masonry blocks.)
If the fireplace is installed directly on carpeting, tile or other combustible
material other than wood flooring, it should be installed on a metal or wood
panel extending the full width and depth of the unit.
At this point, you should have decided what components to include in your
installation, and where the fireplace is to be located. If this has not been
done, stop and consult your dealer for assistance with this planning.
FIREPLACE FRAMING AND INSTALLATION
Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall covering and fireplace facing material. The fireplace framing should be constructed of 2 x 4 lumber or heavier.
- Place fireplace in framing opening.
- Using the four (4) nailing flanges provided with the fireplace, attach two (2) flanges on each side. Attach flanges through prepunched holes. Additional hole locations will be used for different finishing material with thicknesses of 1/2”, 5/8” and 3/4”. Attach these flanges with screws provided, two (2) per nailing flange.
- Nailing flanges should fit directly against framing material. Use at least one (1) nail per tab to secure in place.
| VFP32FP| VFP36FP
---|---|---
“A”| 36 1/4″| 38 1/4″
“B”| 34 1/2″| 39 1/2″
“C”| 17 7/8″| 17 7/8″
Attention: Add 3 3/4″ to “A” Dimensions when using flush mantel base.
Figure 12
PLACEMENT OF GLOWING EMBERS AND LAVA ROCK
Placement of the glowing embers (rock wool) is very individual and light
coverage of the areas indicated will provide your best effects. We recommend
separation of the rock wool by hand and make your coverage as light and fluffy
as possible.
Place just enough embers on the burner to obtain the glow and a gold yellow
flame.
Do not place embers (rock wool) over large ports in rear portion of burner.
A thin layer of glowing embers (rock wool) should be placed under open space
between the right and left middle logs.
Rock wool should not be placed in the area of the pilot assembly.
Replacement of loose material (glowing embers) must be purchased from Empire
Comfort Systems, Inc. Application of excess loose material (glowing embers)
may adversely affect performance of the heater.
WARNING: All previously applied loose material must be removed prior to
reapplication.
Refer to Log Instruction Manual to order loose material (rock wool).
Placing Lava Rock in Front of Burner on Fireplace Floor
Spread lava rocks on fireplace floor in front of the burner pan. The lava rocks
are for decorative effect and are not required for fireplace operation.
ATTENTION: DO NOT PLACE LAVA ROCKS ON BURNER, LOGS OR ROCK WOOL. THE LAVA ROCKS SHOULD ONLY BE PLACED ON THE FIREPLACE FLOOR.
OPERATION INSTRUCTIONS/FLAME APPEARANCE
Flames from the pilot (rear right back side of the pan burner) as well as the
main flame should be visually checked as the log set is installed.
In normal operation at full rate after 10 to 15 minutes, the flame appearance
should be sets of yellow flames.
NOTE: All flames will be random by design, flame height will go up and
down.
Glowing embers (rock wool) can cover the pan burner in between the front and
middle logs, but very little is necessary to cover this area. Excess ember
material causes the yellow flame to become orange and stringy. Apply just
enough to obtain slow glow and a gold yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow
directly into fireplace. Do not place a blower inside the burner area of the
firebox. Ceiling fans may create drafts that alter flame patterns. Sooting and
improper burning will result.
During manufacturing, fabricating and shipping, various components of this
appliance are treated with certain oils, films or bonding agents. These
chemicals are not harmful, but may produce annoying smoke and smells as they
are burned off during the initial operation of the appliance, possibly causing
headaches or eye or lung irritation. This is a normal and temporary
occurrence.
The initial break-in operation should last 2-3 hours with the burner at the
highest setting. Provide maximum ventilation by opening windows or doors to
allow odors to dissipate. Any odors remaining after this initial break-in will
be slight and will disappear with
continued use.
PERIODIC CLEANING – Refer to parts diagram for location
of items discussed below.
- Do not use cleaning fluid to clean logs or any part of heater.
- Logs – brush with soft bristle brush or vacuum with brush attachment.
- Remove loose particles and dust from the burner areas, controls, piezo covers and grate. Don’t remove ceramic media from inside burner box.
- Inspect and clean burner air intake hole. Remove lint or particles with brush. Failure to keep air intake hole clean will result in sooting and poor combustion.
ANNUAL CLEANING/INSPECTION – Refer to parts diagram for location of items discussed below.
- Inspect and clean burner air intake hole. Remove lint or particles with vacuum or brush. Failure to keep air intake hole clean will result in sooting and poor combustion.
- Inspect and clean all burner ports.
- Inspect ODS pilot for operation and accumulation of lint at air intake holes.
- Verify flame pattern and log placement for proper operation.
- Verify smooth and responsive ignition of main burner.
- Check level of ceramic media in burner. Burner should be full, up to the level of openings in burner top.
VFP(32,36)FP(30,31) LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle on
the floor.
WHAT TO DO IF YOU SMELL GAS
-
Do not try to light any appliance.
-
Do not touch any electrical switch;
Do not use any phone in your building. -
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
-
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or turn by hand, don’t try to repair it;
call a qualified service technician. Force or attempted repair may result in a
fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately
call a qualified service technician to inspect the appliance and to replace any
part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
-
STOP! Read the safety information label.
-
Set REMOTE/OFF/ON switch to “OFF.”
-
Turn off all electric power to the appliance (if applicable).
-
Open bottom louver assembly.
-
Push in gas control knob slightly and turn clockwise to “OFF.” NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.
-
Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step.
-
Find pilot – Follow metal tube from gas control. The pilot is behind the burner on the right side.
-
Turn gas control knob counterclockwise to “PILOT.”
-
Push in control knob all the way and hold in. Repeatedly push the Piezo Ignitor Button until the pilot is lit. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob, and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.
• If knob does not pop up when released, STOP and IMMEDIATELY call a qualified service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. -
Turn gas control knob counterclockwise to “ON.”
-
Close bottom louver assembly.
-
Turn on all electric power to the appliance (if appli- cable).
-
Set REMOTE/OFF/ON switch to desired setting.
TO TURN OFF GAS TO APPLIANCE
- Set REMOTE/OFF/ON switch to “OFF.”
- Turn off all electric power to the appliance if service is to be performed (if applicable).
- Open bottom louver assembly.
- Push in gas control knob slightly and turn clockwise to “OFF.” Do not force.
- Close bottom louver assembly.
VFP(32,36)FP(20,21) LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle on
the floor.
WHAT TO DO IF YOU SMELL GAS
-
Do not try to light any appliance.
-
Do not touch any electrical switch;
Do not use any phone in your building. -
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
-
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or turn by hand, don’t try to repair it;
call a qualified service technician. Force or attempted repair may result in a
fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately
call a qualified service technician to inspect the appliance and to replace any
part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
-
STOP! Read the safety information above.
-
Set thermostat (gas control knob) to lowest setting.
-
Turn off all electric power to the appliance (if applicable).
-
Push in gas control knob slightly and turn clockwise
-
Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
-
Find pilot – the pilot is in front of the rear log
-
Turn gas control knob counterclockwise to “PILOT.”
-
Push in gas control knob all the way and hold in. Repeat-edly push the piezo ignitor button until pilot is lit (or use a match to light pilot). Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 through 8.
• If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. -
Attention! Gas control has an INTERLOCK latching device. When the pilot is initially lit and the safety magnet is energized (pilot stays “ON”) the INTERLOCK latching device becomes operative. If the gas control is turned to the “OFF” position or gas flow to the appliance is shut off, the pilot cannot be relighted until the safety magnet is de-energized (approximately 60 seconds). There will be an audible “click” when the safety magnet in the gas control is de-energized. Pilot can now be relighted. Repeat steps 4 through 8.
-
Turn gas control knob counterclockwise to “5”.
-
Turn on all electric power to appliance (if applicable).
-
Set thermostat (gas control knob) to desired setting from “5” to “1 “.
TO TURN OFF GAS TO APPLIANCE
- Set thermostat (gas control knob) to lowest setting.
- Turn off all electric power to appliance if service is to be performed (if applicable).
- Push in gas control knob slightly and turn clockwise to “OFF”. Do not force.
PILOT FLAME CHARACTERISTICS
Figures 13 and 15 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figures 14 and 16 show an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
VFP(32,36)FP(30,31) PILOT
Correct Pilot Flame Pattern
Figure 13 Incorrect Pilot Flame Pattern
Figure 14
If pilot flame pattern is incorrect, as shown in Figure 14
- See Troubleshooting, page 21.
VFP(32,36)FP(20,21) PILOT
Correct Pilot Flame Pattern
Figure 15 Incorrect Pilot Flame Pattern
Figure 16
If pilot flame pattern is incorrect, as shown in Figure 16
- See Troubleshooting, page 21.
Cleaning and Pilot Maintenance
Oxygen Depletion Sensor Pilot (Figure 17)
When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor
as follows:
-
Clean the ODS pilot by loosening nut B from the pilot tubing.
When this procedure is required, grasp nut A with an open end wrench. -
Blow air pressure through the holes indicated by the arrows. This will blow out foreign materials such as dust, lint and spider webs. Tighten nut B also by grasping nut A.
Warning:
Never use needles, wires, or similar cylindrical objects to clean the pilot to
avoid damaging the calibrated ruby that controls the gas flow.
WIRING
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 110 volts.
Maximum length of 20 feet of 16 AWG to conductor wires is to be used with all
optional switches.
Use the two leads (Red and Green) to attach optional components.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be checked with a millivolt
meter 0-1000 MV range.
Remote Receiver
Use the following steps to place the remote receiver adjacent to the gas
valve.
Attention: The remote receiver bracket is not used in this installation.
- The remote receiver can not be placed behind the gas valve and burner assembly.
- When facing the appliance, the remote receiver must be placed to the right of the gas valve.
Install remote control receiver behind bottom louver.
Refer to remote control installation and operating instructions for more
details on remote control.
MAINTENANCE
Keep the control compartment, logs and burner area surrounding the logs clean
by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer to
lighting instructions located on the rating plate of the log set.
Never obstruct the flow of the combustion and ventilation air. Keep the front
of the fireplace clear of all obstacles and materials.
Leave at least 36″ clearance from the front of the fireplace.
Screens should be closed during operation.
TROUBLESHOOTING
SYMPTOMS – POSSIBLE CAUSES AND CORRECTIONS
Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.
-
When ignitor button is pressed, there is no spark at ODS/ pilot.
a. Ignitor electrode positioned wrong – Replace pilot.
b. Ignitor electrode is broken – Replace pilot.
c. Ignitor electrode not connected to ignitor cable – Reconnect ignitor cable.
d. Ignitor cable pinched or wet. Keep ignitor cable dry – Free ignitor cable if pinched by any metal or tubing.
e. Broken ignitor cable – Replace ignitor cable.
f. Bad piezo ignitor – Replace piezo ignitor. -
Appliance produces unwanted odors.
a. Appliance burning vapors from paint, hair spray, glues, etc. – Ventilate room. Stop using odor causing products while heater is running.
b. Gas leak – Locate and correct all leaks. -
Appliance shuts off during use. (Pilot and main burner are off.)
a. Not enough fresh air is available for ODS/pilot to operate – Open window and/or door for ventilation.
b. Low line pressure – Contact local gas company.
c. ODS/pilot is partially clogged – Clean ODS/pilot.
d. Defective thermocouple – Replace pilot. -
Appliance shuts off during use. (Pilot stays on.)
a. Low line pressure – Check line pressure to the valve.
b. Defective thermopile – Check pilot flame, check wire connections, output should be a minimum of 325 millivolts across. TH/TP and TP terminals with ON/OFF switch off. -
Gas odor even when control knob is in OFF position.
a. Gas leak – Locate and correct all leaks.
b. Control valve defective – Replace control valve. -
When ignitor button is pressed, there is spark at ODS/pilot, but no ignition.
a. Gas supply turned off or manual shutoff valve closed
– Turn on gas supply or open manual shutoff valve.
b. Control knob not in PILOT position – Turn control knob to PILOT position.
c. Control knob not pressed in while in PILOT position
– Press in control knob while in PILOT position.
d. Air in gas lines when installed – Continue holding down control knob. Repeat igniting operation until air is removed.
e. ODS/pilot is clogged – Replace ODS/pilot assembly or get it serviced.
f. Gas regulator setting is not correct – Replace gas regulator. -
ODS/pilot lights but flame goes out when control knob is released.
a. Control knob not fully pressed in – Press in control knob fully.
b. Control knob not pressed in long enough – After ODS/pilot lights, keep control knob pressed in 30 seconds.
c. Manual Shutoff valve not fully open – Fully open manual shutoff valve.
d. Thermocouple connection loose at control valve – Hand tighten until snug, then tighten 1/4 turn more.
e. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by either low gas pressure or dirty or partially clogged ODS/pilot – Contact local gas company.
f. Thermocouple damaged – Replace thermocouple.
g. Control valve damaged – Replace control valve. -
Burner does not light after ODS/pilot is lit.
a. Burner orifice clogged – Clean burner or replace main burner orifice.
b. Burner orifice diameter is too small – Replace burner orifice.
c. Inlet gas pressure is too low – Contact qualified service person. -
If burning at main burner orifice occurs (a loud, roaring blow torch noise).
a. You must turn off burner assembly and contact a qualified service person.
b. Manifold pressure is too low – Contact local gas company.
c. Burner orifice clogged – Clean burner or replace burner orifice. -
Logs appear to smoke after initial operation.
a. Vapors from paint or curing process of logs – Problem will stop after a few hours of operation. Run the heater with the damper open if you have one, or open a window for the first few hours.
Log heater is intended to be smokeless. Turn OFF heater and call qualified service person. -
Heater produces a whistling noise when main burner is lit.
a. Turning control knob to HIGH position when main burner is cold – Turn control knob to LOW position and let warm up for a minute.
b. Air in gas line – Operate burner until air is removed from line. Have gas line checked by local gas company.
c. Dirty or partially clogged burner orifice – Clean burner or replace burner orifice. -
No gas to pilot.
a. LP-regulator shut down due to inlet pressure too high – Verify LP tank regulator is installed and set at 11″ to 13″ w.c. Replace regulator on heater.
If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately.
PARTS LIST
ATTENTION: When ordering parts, it is very important that part number and description of part coincide.
Index
Number
| Part Number
VFP32FP(20,21)| Part Number
VFP32FP(30,31)| Part Number
VFP36FP(20,21)| Part Number
VFP36FP(30,31)| Description
---|---|---|---|---|---
1| 17149| 17149| 17149| 17149| TOP STANDOFF
2| 20098| 20098| 20126| 20126| FIREBOX ASSEMBLY
3| 10554| 10554| 10554| 10554| NAILING FLANGE
4| 20170| 20170| 20134| 20134| INNER FIREBOX TOP
5| 17162| 17162| 17162| 17162| JUNCTION BOX ASSEMBLY
6| 17448| 17448| 18802| 18802| FRAME, TOP
7| 17169| 17169| 18807| 18807| LOUVER ASSEMBLY UPPER
8| 20020| 20020| 20145| 20145| HOOD
9| 20475| 20475| 20478| 20478| FRAME, RIGHT
10| 20476| 20476| 20479| 20479| FRAME, LEFT
11| 20095| 20095| 20143| 20143| FRONT FRAME WELDED ASSEMBLY
12| 17170| 17170| 18808| 18808| LOUVER ASSEMBLY LOWER
13| P200| P200| P200| P200| FITTING, ORIFICE
14| –| –| –| P211| ORIFICE #32 (NAT)
14| –| –| P213| –| ORIFICE #37 (NAT)
14| –| P243| –| –| ORIFICE #36 (NAT)
14| –| –| P245| P245| ORIFICE #50 (LP)
14| P250| P250| –| –| ORIFICE 1.65MM (LP)
14| P286| –| –| –| ORIFICE #42 (NAT)
15| R5675| R5675| R5675| R5675| AIR SHUTTER-FULLY OPEN (LP UNITS)
15| R5676| R5676| R5676| R5676| AIR SHUTTER (NAT UNITS)
16A| –| R3623| –| R3623| PILOT ASSEMBLY LP
16A| –| R3624| –| R3624| PILOT ASSEMBLY NAT
16B| R5170| –| R5170| –| PILOT, LP
16B| R5171| –| R5171| –| PILOT NAT
17| 20467| 20467| 20467| 20467| PILOT SHIELD
18| 17370| 17370| 17386| 17386| BURNER ASSEMBLY
19| 20091| 20091| 20138| 20138| BURNER BASE PLATE ASSEMBLY
20A| –| 17369| –| 17369| TUBING ASSEMBLY
20B| 20093| –| 20093| –| TUBING ASSEMBLY
21| R2423| R2423| R2423| R2423| CONNECTOR, MALE 5/16 X 3/8 NPT
22| 20115| 20115| 20115| 20115| VALVE BRACKET
23A| –| R3625| –| R3625| VALVE, LPG
23A| –| R3626| –| R3626| VALVE, NAT
23B| 11923| –| 11923| –| VALVE ASSEMBLY – NAT ONLY
23B| 11924| –| 11924| –| VALVE ASSEMBLY – LP ONLY
24| –| R3436| –| R3436| SWITCH, REMOTE/OFF/ON
25| R2708| R2708| R2708| R2708| IGNITER, PIEZO
26A| –| 20117| –| 20117| TUBING ASSEMBLY (NAT)
26A| –| 20122| –| 20122| TUBING ASSEMBLY (LP)
26B| 20094| –| 20094| –| TUBING ASSEMBLY
27| –| R7063| –| R7063| REGULATOR, PILOT (NAT ONLY)
28| –| 20116| –| 20116| TUBING ASSEMBLY (NAT ONLY)
29| P239| –| P239| –| NIPPLE, 3/8 NPT X 1 1/2
30| R6427| –| R6427| –| REGULATOR, NAT 6.0” W.C. (NAT ONLY)
30| R6428| –| R6428| –| REGULATOR, LP 10.0” W.C. (LP ONLY)
NOT SHOWN| 18704| 18704| 18704| 18704| DECORATIVE ROCK (1 LB)
NOT SHOWN| R5668| R5668| R5668| R5668| WIRE IGNITOR 12”
NOT SHOWN| R3491| R3491| R3491| R3491| COVER, JUNCTION BOX
NOT SHOWN| R3492| R3492| R3492| R3492| RECEPTICAL, 3 PRONG
NOT SHOWN| –| R3435| –| R3435| WIRE ASSEMBLY
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE
INJURY OR DEATH.
NOTE: SEE LOG INSTRUCTION MANUAL FOR DETAILS ON LOGS AND EMBERS
PARTS VIEW
HOW TO ORDER REPAIR PARTS
Parts can be ordered only through your service person or dealer. For best
results, the service person or dealer should order parts through the
distributor.
Parts can be shipped directly to the service person/dealer.
All parts listed in the Parts List have a Part Number. When ordering parts,
first obtain the Model Number from the name plate on your equipment.
Then determine the Part Number (not the Index Number) and the Description of
each part from the following appropriate illustration and list. Be sure to
give all this information.
Fireplace Model Number ——————- Part Description ———————–
Fireplace Serial Number ——————- Part Number ———————–
Type of Gas (Propane or Natural) ———————–
Do not order bolts, screws, washers or nuts. They are standard hardware items
and can be purchased at any local hardware store.
Shipments contingent upon strikes, fires and all causes beyond our control.
OPTIONAL VARIABLE SPEED BLOWER INSTALLATION INSTRUCTIONS
FBB4 Blower Installation
Attention: Install blower assembly before connecting gas inlet supply
line.
Note: Junction box on right side of fireplace must be pre-wired at time of
fireplace installation for use with blower assembly. It is recommended that an
ON/OFF wall switch be installed that will activate the power supply to the
furnace by a qualified electrician. See page 26 for junction box wiring
instructions
-
If installed, turn OFF gas supply to fireplace.
-
If applicable, turn OFF electric supply to fireplace.
-
Lower bottom louver on fireplace.
Attention: If installed, do not damage gas inlet supply line when blower assembly is inserted into fireplace. If necessary, removal of the gas inlet supply line may be necessary. -
Insert blower assembly into interior, bottom of fireplace. Position blower assembly behind gas valve, align notch on back of blower assembly with center screw on fireplace back and push blower assembly against fireplace back. The blower wheel must be centered with the back wall of the fireplace. Place blower assembly against the back wall. The magnets on the back and bottom of blower assembly will sufficiently hold blower assembly in place.
-
Position speed control box to the right of gas valve. Attach speed control box to bottom of fireplace. The magnets on the bottom of speed control will sufficiently hold the speed control box in place.
-
With base (flush face) of fan control switch facing upward, insert base flanges of fan control switch under the mounting tabs on valve bracket. The base (flush face) of fan control switch must be in contract with bottom of the firebox.
-
Insert power cord plug into junction box.
-
Close bottom louver on fireplace.
Note: This blower is equipped with a heat activated fan control switch. Fan will operate when the fireplace warms up, and will turn off when the fireplace cools down. -
Installation of FBB4 optional variable speed blower assembly is completed.
Wiring
The appliance, when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized.
This appliance is equipped with a three-prong [grounding] plug for your
protection against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding prong from
this plug. For an ungrounded receptacle, an adapter, which has two prongs and
a wire for grounding, can be purchased, plugged into the ungrounded receptacle
and its wire connected to the receptacle mounting screw. With this wire
completing the ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Blower Motor
The blower motor does not have oiling holes. Do not attempt to oil the blower
motor.
Blower Wheels
The blower wheels will collect lint and could require periodic cleaning. If
the air output decreases or the noise level increases, it indicates a dirty
blower wheel. Remove blower and clean blower wheels.
WARNING:
Unplugging of blower accessory will not stop the heater from cycling. To turn
off gas to the unvented heater:
Push in gas control knob slightly and turn clockwise to “OFF.” Do not force.
1 | FBB4 | BLOWER ASSEMBLY COMPLETE |
---|---|---|
2 | R7649 | FAN CONTROL |
3 | R4192 | SPEED CONTROL KNOB |
4 | R4186 | SPEED CONTROL |
Figure 21
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).
A factory installed junction box is located on the lower right hand side of the fireplace. Wiring must be fed to the junction box and attached to the receptacle that is provided. Remove the knockout in the installed junction box to accept wiring into the junction box. Install a UL listed cable clamp (not supplied) in the knockout hole. Leave approximately 6″ of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to opposite
side of receptacle. The ground wire should be attached to the green (neutral)
screw.
Install the receptacle into the junction box. Attach cover plate.
OPTIONAL BRICK LINER INSTALLATION INSTRUCTIONS
Brick Liner VPP32A and VPP36A
- Remove screen from fireplace.
- Remove branch log and rear log from burner assembly.
- Insert back panel into firebox.
- Insert one (1) side panel into firebox.
- Use two (2) brick panel brackets to secure side panel. Align clearance hole on brick panel bracket with screw hole in the left or right interior, top and bottom of firebox. Use two (2) 10 x 1/2″ screws to attach brick panel bracket to interior top and bottom of firebox.
- Repeat steps 4 and 5 to install second side panel.
- Replace rear log and branch log onto burner assembly.
- Replace screen onto fireplace.
- Installation of optional brick liner is completed.
PART NAME| VPP32A
PART NO.| VPP36A
PART NO.
---|---|---
BRICK PANEL SIDE – LEFT| R8692| R8695
BRICK PANEL SIDE – RIGHT| R8693| R8696
BRICK PANEL BACK| R8694| R8697
BRICK PANEL BRACKET (4 REQ’D)| 19401| 19401
SERVICE NOTES —
Empire Comfort Systems, Inc.
918 Freeburg Ave. Belleville, IL 62220
PH: 618-233-7420 or
800-851-3153
FAX: 618-233-7097 or
800-443-8648
info@empirecomfort.com
www.empirecomfort.com
20101-0-0306
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>