Installation Instructions & User Guide
Please leave these instructions with the end user
Product Code: N2 SHCVO C (D8)
Specifications
Dynamic Water Pressure
Maximum Static Pressure: 10.0 bar
Inlet Water Temperature
IMPORTANT
The inlet hot water must be at least 10°C above the required blend
temperature.
Inlet Dimensions
Tools You’ll Need
Prior to Installation
All products manufactured and supplied by Bristan are safe to use provided
that they are installed, operated and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999 and current
by-laws. For full Installation Requirements & Notes (IRN) please visit
wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of
future maintenance. Before installing this product the water supply must be
thoroughly flushed in order to remove any swarf, solder etc.
Full access must be made available for future maintenance/ servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires,
cables or water supply pipes. This can be checked with the aid of an
electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
This product must not be modified in any way as this will invalidate the
guarantee.
If in doubt, contact a registered plumber, your Local Water Authority or the
Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Cavity Dimensions (mm)
Minimum
Cavity Depth: 35mm Concealing Plate
Adjustment Range: 30mm
|
---|---
Pack Contents
Valve Configuration
Remove the inlet elbows and filters.
Remove the plastic inserts from the valve inlets and insert the flow
regulators.
Replace the elbows, ensuring the filters are fitted.
Screw the shrouds onto the valve.
Installation
Install suitable batons (if required) onto the rear cavity.
Mark the position of the valve and drill and plug holes to suit.
Secure the valve using the screws supplied (solid walls only) or a suitable alternative.
Plumb the valve into your chosen outlet.
Turn on the water supply and check the valve for any leaks.
Draw around the concealing plate as a template, measuring in by 10mm to give clearance. Finish the wall surface. Using a silicon sealant, push on the concealing plate and hold firmly until set.
Temperature Adjustment
Turn the handle to the maximum temperature setting, then remove it.
Turn the spindle to increase or decrease the temperature.
Check the temperature and adjust until you achieve the desired result.
Fit the temperature handle back in the maximum hot position.
General Cleaning
Bristan products are made from premium materials, with hand polishing and
electroplated finishes.
Your taps or shower should be regularly cleaned with warm water, a mild pH-
neutral liquid soap, and polished with a soft cloth. Any residues from soap,
toiletries etc. should be rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the
surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges,
steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by the dye found in
some cloths, so it is also important to avoid hanging cloths on spouts.
Operation
Wall Outlet Installation
Choose the location for the wall outlet and create a 25-30mm hole in the wall.
Ensure your shower accessories have enough reach from that position.
Finish the wall surface.
Maintenance – Cartridge Cleaning
| |
---|---|---
Remove any O-rings and soak all components in de-scaler and wash off
in clean water. Examine all seals and
replace if needed. Use WRAS approved silicon based grease on all seals.|
Reverse the installation steps, ensuring the temperature stop is aligned
correctly.| Follow the Temperature Adjustment Steps if required.
Troubleshooting
Symptom | Cause | Remedy |
---|
No flow or
low flow rate| Partially closed isolation valve.| Open isolation valve.
Instantaneous water heater cycles on and off
as flow rate or pressure is too low.| Increase water flow rate or
pressure through system.
Head of water is below the
minimum distance required.| Refer to the specification for the
minimum distance required.
Are the water supply pressures balanced?| If pressures are unbalanced. a
pressure reducing valve
should be used for optimum performance.
Hot or cold water being drawn off elsewhere
causing pressure changes or instantaneous
boiler temperature changes.| Do not use other water outlets when using the
shower
Airlock or partial blockage in the supply
pipework.| Flush through pipework and filters to ensure removal
of debris and any airlocks.
Hot/Cold water supply has failed| Check the hot and cold feeds. The shower
will not
work if either fails.
Maximum
Water
Temperature
too Hot/Cold| Maximum Water Temperature
needs adjusting.| Refer to the Temperature Setting section to set your
desired maximum temperature.
Outlet Water
Temperature
too Hot/Cold| Filter/pipe blockage| Flush through pipework and filters to
ensure
removal of debris and any airlocks.
Installtion conditions outside
operating parameters.| Refer to the specification for the
minimum distance required.
Hot water temperature is less than 10°C
above the required blend temperature| Adjust hot water temperature or wait for
water to
reheat if a stored water system is used.
Instantaneous water not igniting because the
water flow rate is too low.| Increase water flow rate through the system.
Refer to the
Maintenance section to clean/check the cartridge and filters
for any damage. Contact your boiler manufacturer.
Instantaneous water not igniting because the
water pressure is too low.| Refer to the specification for system
requirements.
Increase water pressure through the system.
Contact your boiler manufacturer.
Only hot/
cold water
from Shower
Valve| Inlet water supplies are reversed.| Check the water inlet connections
are the correct way
around: Hot on the left. Cold on the right when viewed from the front. Rework
pipework as necessary.
Filter/pipe blockage| Flush through pipework and filters to ensure removal of
debris and any airlocks.
Water
dripping
from shower| This is normal for a short time after using the
shower| This is caused by residual water tension. the build up of
water in the shower.
If water continues to drip,
possibly due to the cartridge| Remove cartridge and clean, refer to
‘Maintenance’ section
before starting any maintenance.
Shower does
not turn on| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply
Our Guarantee
At Bristan, we want to make things as easy as possible for our customers.
That’s why we offer solid guarantees on all our products, effective from the
date of purchase, to give you peace of mind. To start your free guarantee
simply scan the QR code and register your product.
Alternatively visit
www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where
our expert team of advisors will be able to offer you any help and advice. For
full guarantee terms and conditions visit www.bristan.com/service-
centre/guarantees.