MAYTAG W11599647A- SP Commercial Dryer Instruction Manual
- June 10, 2024
- Maytag
Table of Contents
- MAYTAG W11599647A- SP Commercial Dryer
- Product Information
- Product Usage Instructions
- INSTALLATION INSTRUCTIONS
- DRYER SAFETY
- INSTALLATION REQUIREMENTS
- Location Requirements
- GROUNDING INSTRUCTIONS
- INSTALLATION INSTRUCTIONS GAS DRYER
- INSTALLATION INSTRUCTIONS ELECTRIC DRYER
- REVERSING THE DOOR SWING
- MAINTENANCE INSTRUCTIONS
- ELECTRONIC CONTROL SETUP
- CONTROL SET-UP PROCEDURES
- ITEMS EXCLUDED FROM WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MAYTAG W11599647A- SP Commercial Dryer
Product Information
The product is a clothes dryer manufactured by Maytag Commercial Laundry. The user manual provides installation instructions and safety guidelines to ensure the safe and effective use of the product. It is recommended that the owner posts safety warnings and instructions for customers to follow in case of a gas leak. The installation requirements must be followed to avoid the risk of fire, electric shock, or injury to persons when using the dryer.
Product Usage Instructions
- Before using the dryer, read all instructions provided in the user manual.
- Do not place items exposed to cooking oils in the dryer as they may cause a load to catch fire. The final part of the tumble dryer cycle occurs without heat (cool down period) to reduce the risk of fire due to contaminated loads.
- Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
- Children must not play on or in the dryer. Close supervision of children is necessary when the dryer is used near them.
- Before discarding or removing the dryer from service, remove the door to the drying compartment.
- Do not reach into the dryer if the drum is moving.
- The dryer must not be installed or stored where it will be exposed to the weather.
INSTALLATION INSTRUCTIONS
COMMERCIAL DRYER GAS OR ELECTRIC INSTRUCTIONS D’INSTALLATION
W11595585A W11599647A- SP
www.maytagcommerciallaundry.com
TABLE OF CONTENTS
DRYER SAFETY ……………………………………………………………….. 2 INSTALLATION REQUIREMENTS
……………………………………… 5
Tools and Parts………………………………………………………………. 5 Location
Requirements……………………………………………………. 6 Electrical Requirements
…………………………………………………… 7 Gas Supply Requirements …………………………………………….. 10 Venting
Requirements ………………………………………………….. 10 Leveling ………………………………………………………………………. 12
INSTALLATION INSTRUCTIONS GAS DRYER …………….. 13 Make Gas
Connection……………………………………………………. 13 Gas Supply Line…………………………………………………………….. 13
Connect Vent ………………………………………………………………… 14 Complete Installation
…………………………………………………….. 14 INSTALLATION INSTRUCTIONS ELECTRIC DRYER …… 15
Power Supply Cord (U.S.A. Only) ……………………………………. 15 Direct Wire Method (U.S.A.
Only)…………………………………….. 18 Connect Vent ………………………………………………………………… 21 Complete
Installation …………………………………………………….. 21 REVERSING THE DOOR SWING ……………………………………
22 Remove the Door Assembly …………………………………………… 22 Reverse Hinge
………………………………………………………………. 22 Reverse The Strike ………………………………………………………… 23
Reinstall The Door ………………………………………………………… 23 MAINTENANCE INSTRUCTIONS
………………………………….. 23 ELECTRONIC CONTROL SETUP ………………………………….. 24
WARRANTY…………………………………………………………………. 28
DRYER SAFETY
It is recommended that the owner post, in a prominent location, instructions
for the customer’s use in the event the customer smells gas. This information
should be obtained from your gas supplier. Post the following warning in a
prominent location.
2
WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
· Do not try to light any appliance. · Do not touch any electrical switch; do
not use any phone in your building. · Clear the room, building, or area of all
occupants. · Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions. · If you cannot reach your gas
supplier, call the fire department. Installation and service must be
performed by a qualified installer, service agency, or the gas supplier. Fire
Hazard Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. Do not install a booster fan in the exhaust
duct. Install all clothes dryers in accordance with the installation
instructions of the manufacturer of the dryer. – Clothes dryer installation
must be performed by a qualified installer. – Install the clothes dryer
according to the manufacturer’s instructions and local codes. – Do not install
a clothes dryer with flexible plastic venting materials or flexible metal
(foil type) duct. If
flexibe metal duct is installed, it must be of a specific type identified by
the appliance manufacturer as suitable for use with clothes dryers. Flexible
venting materials are known to collapse, be easily crushed, and trap lint.
These conditions will obstruct clothes dryer airflow and increase the risk of
fire. – To reduce the risk of severe injury or death, follow all installation
instructions. – Save these instructions.
3
In the State of Massachusetts, the following installation instructions apply: Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by the State of Massachusetts. Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use shall be listed. A flexible gas connector, when used, must not exceed 4 feet (121.9 cm). To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following:
Read all instructions before using the dryer. Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire. To reduce the risk of fire due to contaminated loads, the final part of a tumble dryer cycle occurs without heat (cool down period). Avoid stopping a tumble dryer before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipated. Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, drycleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
Do not allow children to play on or in the dryer. Close supervision of
children is necessary when the dryer is used near children.
Before the dryer is removed from service or discarded, remove the door to the
drying compartment.
Do not reach into the dryer if the drum is moving.
Do not install or store the dryer where it will be exposed to the weather.
Do not tamper with controls.
Do not repair or replace any part of the dryer or attempt any servicing unless
specifically recommended in this Use and Care Guide or in published user-
repair instructions that you understand and have the skills to carry out.
Do not use fabric softeners or products to eliminate static unless recommended
by the manufacturer of the fabric softener or product.
Do not use heat to dry articles containing foam rubber or similarly textured
rubber-like materials.
Clean lint screen before or after each load.
Keep area around the exhaust opening and adjacent surrounding areas free from
the accumulation of lint, dust, and dirt.
The interior of the dryer and exhaust vent should be cleaned periodically by
qualified service personnel.
See “Electrical Requirements” located in the installation instructions for
grounding instructions.
WARNING: Risk of Fire. Do not install a booster fan in the exhaust duct. NOTE: The booster fan warning does not apply to clothes dryers intended to be installed in a multiple clothes dryer system, with an engineered exhaust duct system that is installed per the clothes dryer manufacturer’s guidelines.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part 1, CSA C22.1.
4
Tools Needed:
8″ or 10″ Pipe wrench
INSTALLATION REQUIREMENTS
Tools & Parts
8″ or 10″ Adjustable wrench
that opens to 1″
Flat-blade screwdriver
Phillips screwdriver
TORX T20® security screwdriver or bit
1″ Hex-head socket wrench
5/16″ Socket wrench
Pliers (that open to 19/16″)
Level
Utility knife
Pipe-joint compound resistant to Propane gas
Putty knife
Caulk gun and caulk (for installing new exhaust vent)
Vent clamps
Parts supplied:
Remove parts bag from dryer drum. Check that all parts were included. Foot
boot (4) Dryer foot (4)
PD models: Cam for service door lock PR models: Card reader bezel, card reader
wire harness, hardware
Optional parts not included:
279810 Long dryer foot
LP Kit W10402145
208 V electric element: U.S. W10206352A, Canada W10206351A
TORX are registered trademarks of Acument Intellectual Properties, LLC.
5
Location Requirements
WARNING Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Do not install or store the dryer where it will be exposed to
the weather. Proper installation is your responsibility. You will need: A
grounded electrical outlet located within 6 ft (1.8 m) of where the power cord
is attached to the back of the dryer. See “Electrical Requirements.” A level
floor with a maximum slope of 1″ (25 mm) under entire dryer. Installing the
dryer on soft floor surfaces, such as carpets or surfaces with foam backing,
is not recommended. If installing a gas dryer: IMPORTANT: Observe all
governing codes and ordinances. Check code requirements: Some codes limit or
do not permit installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector. Make sure that lower edges of
the cabinet, plus the back and bottom sides of the dryer, are free of
obstructions to permit adequate clearance of air openings for combustion air.
See “Recessed Area and Closet Installation Instructions” below for minimum
spacing requirements. NOTE: The dryer must not be installed in an area where
it will be exposed to water and/or weather.
Recessed Area and Closet Installation Instructions This dryer may be installed
in a recessed area or closet. For recessed area and closet installations,
minimum clearances can be found on the warning label on the rear of the dryer.
The installation spacing is in inches and is the minimum allowable. Additional
spacing should be considered for ease of installation, servicing, and
compliance with local codes and ordinances. If closet door is installed, the
minimum unobstructed air opening in the top and bottom is required. Louvered
doors with equivalent air openings are acceptable. The dryer must be exhausted
outdoors. No other fuel-burning appliance may be installed in the same closet
as the dryer.
Minimum Installation Clearances
14″ (356 mm) maximum
15″ (381 mm)*
Closet door
0″ (0 mm)
0″ (0 mm)
0″ (0 mm)
Recessed front view
1″ (25 mm) Closet side view
*Additional clearances for wall, door, and floor moldings may be required or if external exhaust elbow is used.
48 in2 (310 cm2)
Front View
24 in2 (155 cm2)
3″ (76 mm) closet door
3″ (76 mm)
*Opening is the minimum for a closet door. Louvered doors with equivalent air openings are acceptable.
Product Dimensions 27″ (68.6 cm) Dryer
27″ (686 mm)
6 3/4″ (152 mm)
ELECTRIC
BACK VIEW
13″ (330 mm)
4″ (102 mm) dia
GAS
EXHAUST
61/4″ (159 mm)
283/4″ (733 mm)
4 1/4″ (108 mm)
7 7/8″ (200 mm)
11/4″ (32 mm)
29″ (736 mm) 271/4″ (695 mm)
BOTTOM EXHAUST
35″ (889 mm)
SIDE VIEW
LEFT OR RIGHT SIDE EXHAUST
10 1/4″ (260 mm)
7 1/4″ (184 mm)
14 1/8″ (359 mm)
3/4″ (21 mm)
41/4″ (108 mm)
6
Electrical Requirements Gas Dryer Gas Dryer Grounding
IMPORTANT: The dryer must be electrically grounded in accordance with local
codes and ordinances or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, latest edition, or Canadian Electrical Code,
CSA C22.1. If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that the ground
path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association One Batterymarch Park, Quincy, MA 02269
CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Do not ground to a gas pipe.
Do not have a fuse in the neutral or ground circuit.
A 120 V, 60 Hz AC only, 15 A or 20 A, fused electrical circuit is required. A
time-delay fuse or circuit breaker is also recommended. It is recommended that
a separate circuit serving only this dryer be provided.
This dryer is equipped with a power supply cord having a 3-prong grounding
plug.
To minimize the possibility of shock, the cord must be plugged into a mating,
3 prong, grounding-type outlet, grounded in accordance with local codes and
ordinances. If a mating outlet is not available, it is the personal
responsibility and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
If codes permit and a separate ground wire is used, it is recommended that a
qualified electrician determine that the ground path is adequate.
Check with a qualified electrician if you are not sure the dryer is properly
grounded.
Electrical Requirements Electric Dryer (U.S.A. Only)
It is your responsibility:
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in conformance with
the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes
and ordinances.
The National Electrical Code requires a 4-wire power supply connection for
homes built after 1996, dryer circuits involved in remodeling after 1996, and
all mobile home installations.
A copy of the above code standards can be obtained from: National Fire
Protection Association, One Batterymarch Park, Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120 V/240 V, 60 Hz AC only
electrical supply (or 3 or 4 wire, 120 V/208 V electrical supply, if specified
on the serial/rating plate) on a separate 30 A circuit, fused on both sides of
the line. A time delay fuse or circuit breaker is recommended. Connect to an
individual branch circuit. Do not have a fuse in the neutral or grounding
circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is recommended that a
qualified electrician determine that the ground path is adequate.
7
Electrical Connection
To properly install your dryer, you must determine the type of electrical
connection you will be using and follow the instructions provided for it here.
This dryer is manufactured ready to install with a 3-wire electrical supply
connection. The neutral ground conductor is permanently connected to the
neutral conductor (white wire) within the dryer. If the dryer is installed
with a 4-wire electrical supply connection, the neutral ground conductor must
be removed from the external ground connector (green screw), and secured under
the neutral terminal (center or white wire) of the terminal block. When the
neutral ground conductor is secured under the neutral terminal (center or
white wire) of the terminal block, the dryer cabinet is isolated from the
neutral conductor.
If local codes do not permit the connection of a neutral ground wire to the
neutral wire, see “Optional 3-wire connection” section.
A 4-wire power supply connection must be used when the appliance is installed
in a location where grounding through the neutral conductor is prohibited.
Grounding through the neutral is prohibited for (1) new branch-circuit
installations (2) areas where local codes prohibit grounding through the
neutral conductor.
Electric Dryer Power Supply Cord
Electric Dryer Grounding
If using a power supply cord: Use a UL listed power supply cord kit marked for
use with clothes dryers. The kit should contain: A UL listed 30 A power supply
cord, rated 120 V/240 V
minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m)
long. The wires that connect to the dryer must end in ring terminals or “U”
shaped spade terminals with upturned ends. A UL listed strain relief.
If your outlet looks like this:
Then choose a 4-wire power supply cord with ring
or spade terminals and UL listed strain relief. The
4-wire power supply cord, at least 4 ft (1.22 m)
long, must have four 10-gauge copper wires and
match a 4-wire receptacle of NEMA Type 14R-
4-Wire Receptacle
30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must
(14R-30R) be identified by a white cover.
If your outlet looks like this:
Then choose a 3-wire power supply cord with ring or spade terminals and UL
listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m)
long, must have three 10-gauge copper wires and match a 3-wire receptacle of
NEMA Type 10R3-Wire 30R. Receptacle (10R-30R)
8
Direct Wire
Electrical Requirements Canada only
Fire Hazard Use 10 gauge copper wire. Use a UL listed strain relief.
Disconnect power before making electrical connections. Connect neutral wire
(white or center wire) to center terminal. Ground wire (green or bare wire)
must be connected to green ground connector. Connect remaining 2 supply wires
to remaining 2 terminals (gold). Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
If connecting by direct wire: Power supply cable must match power supply
(4-wire or 3-wire) and be: Flexible armored cable or nonmetallic sheathed
copper
cable (with ground wire), covered with flexible metallic conduit. All current-
carrying wires must be insulated. 10-gauge solid copper wire (do not use
aluminum). At least 5 ft (1.52 m) long.
It is your responsibility:
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1 latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association,178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120 V/240 V, 60 Hz AC only electrical supply on a separate 30 A circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
This dryer is equipped with a CSA International
Certified Power Cord intended to be plugged
into a standard 14R-30R wall receptacle.
The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.
4-Wire Receptacle (14R-30R)
Do not use an extension cord.
If you are using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317. For further information, please reference the service numbers located in the “Assistance or Service” section.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
9
Gas Supply Requirements
WARNING
Venting Requirements
Explosion Hazard
Use a new CSA International-approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make sure gas pressure does
not exceed 13″ (33 cm) water column.
Examples of a qualified person include:
licensed heating personnel, authorized gas company personnel, and authorized
service personnel.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Observe all governing codes and ordinances. This installation
must conform with all local codes and ordinances. In the absence of local
codes, installation must conform with American National Standard, National
Fuel Gas Code ANSI Z223.1/NFPA 54 or CAN/CSA B149.
A copy of the above code standards can be obtained from:
National Fire Protection Association One Batterymarch Park, Quincy, MA 02269
CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
The design of this dryer has been certified by CSA International for use at
altitudes up to 10,000 ft (3,048 m) above sea level at the B.T.U. rating
indicated on the model/serial plate. Burner input adjustments are not required
when the dryer is operated up to this elevation. When installed above 10,000
ft (3,048 m), a four percent (4%) reduction of the burner B.T.U. rating shown
on the model/serial plate is required for each 1,000 ft (305 m) increase in
elevation. For assistance when converting to other gas types and/or installing
above 10,000 ft (3,048 m) elevation, contact your local service company. Type
of Gas This dryer is equipped for use with natural gas. It is designcertified
by CSA International for propane and butane gases with appropriate conversion.
No attempt shall be made to convert the dryer from the gas specified on the
serial/rating plate for use with a different gas without consulting the
serving gas supplier. Conversion must be done by a qualified service
technician. Gas conversion kit part number is W10402145. This part number is
also available on a label on the gas valve burner base.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and
ordinances.
The dryer exhaust must not be connected into any gas vent, chimney, wall,
ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or
flexible vent shall be used for exhausting. Only a 4″ (102 mm) heavy, metal
exhaust vent and clamps may be used. Do not use an exhaust hood with a
magnetic latch. Use clamps to seal all joints. Do not use screws or other
fastening devices that extend into the interior of the duct and catch lint. Do
not use duct tape. Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid crushing and kinking.
Flexible metal vent (acceptable only if accessible to clean):
Must be fully extended and supported in final dryer location.
Remove excess to avoid sagging and kinking that may result in reduced airflow
and poor performance.
Do not install in enclosed walls, ceilings, or floors.
The total length should not exceed 73/4 ft (2.4 m).
An exhaust hood should cap the vent to prevent rodents and insects from
entering the home or business.
The exhaust hood must be at least 12″ (305 mm) from the ground or any object
that may be in the path of the exhaust (such as flowers, rocks, or bushes).
If using an existing vent system, clean lint from the entire length of the
system and make sure the exhaust hood is not plugged with lint. Replace any
plastic or metal foil vent with rigid metal or flexible metal vent. Plan
installation to use the fewest number of elbows and turns.
Good
Better
10
Allow as much room as possible when using elbows or making turns. Bend the
vent gradually to avoid kinking. Vent outlet is located at the back of the
dryer, at bottom center. The vent can be routed up, down, left, right, behind
the dryer, or straight out the back of the dryer. See “Product Dimensions” in
the “Location Requirements” section.
Make-up air: Although each single-load dryer should have an unobstructed
outdoor air opening of 24 in2 (154 cm2) (based on 1 in2 [6.5 cm2] per 1,000
B.T.U. [252 kcal]), common make-up air openings are also acceptable. Set up
common openings so that the make-up air is distributed equally to all of the
dryers. Keep in mind that the coverage area must be increased by 33% to
account for use of registers or louvers over the openings. Also, make-up air
openings should not be installed near the location of exhaust vents exiting
the building.
Vent System Length Maximum length of the vent system depends upon the type of
vent used, number of elbows, and type of exhaust hood. The maximum length for
rigid vent is shown in the chart.
Maximum Vent Length
4″ (102 mm) Diameter Exhaust Hoods
Box
Louvered
21/2″ (63.5 mm) Angled
Vent System Chart (Rigid Metal Vent)
No. of 90° Turns
Box Hood and Louvered Style
Angled Hood Style
0
130 ft (39.6 m)
129 ft (39.3 m)
1
125 ft (38.1 m)
119 ft (36.3 m)
2
115 ft (35.1 m)
109 ft (33.2 m)
3
106 ft (32.3 m)
100 ft (30.5 m)
4
98 ft (29.9 m)
92 ft (28.0 m)
For vent systems not covered by the vent specification chart, see your parts distributor. Provision must be made for enough air for combustion and ventilation. (Check governing codes and ordinances.) See “Recessed Area and Closet Installation Instructions” in the “Location Requirements” sections. A 4″ (102 mm) outlet hood is preferred. However, a 21/2″ (64 mm) outlet exhaust hood may be used. A 21/2″ (64 mm) outlet creates greater back pressure than other hood types. For permanent installation, a stationary vent system is required. Connect Vent 1. If connecting to existing vent, make sure the vent is clean.
2. Using a 4″ (102 mm) clamp, connect vent to exhaust outlet
in dryer.
Vent Collar
NOTE: Do not remove vent collar.
3. Tighten hose clamp with Phillips screwdriver.
4. Make sure the vent is secured to exhaust hood with a 4″ (102 mm) clamp.
5. Move dryer into final position. Do not crush or kink vent. Make sure dryer
is level.
NOTE: Testing for proper ventilation should be done with a Manometer.
Minimum: 0.01″ (0.2 mm). Maximum: 0.6″ (16 mm). For vent systems not covered
by the vent specification chart, see your parts distributor. If dryer is
installed in a confined area, such as a bedroom, bathroom, or closet,
provision must be made for enough air for combustion and ventilation. (Check
governing codes and ordinances.) See “Recessed Area and Closet Installation
Instructions” in the “Location Requirements” section. A 4″ (102 mm) outlet
hood is preferred. However, a 21/2″ (64 mm) outlet exhaust hood may be used. A
21/2″ (64 mm) outlet creates greater back pressure than other hood types. For
permanent installation, a stationary vent system is required. If An Exhaust
Hood Cannot Be Used The outside end of the main vent should have a sweep elbow
directed downward.
12″ minimum (305 mm)*
*Minimum clearance above any accumulation of snow, ice, or debris such as leaves
If the main vent travels vertically through the roof, rather than through the
wall, install a 180° sweep elbow on the end of the vent at least 2 ft (610 mm)
above the highest part of the building. The opening in the wall or roof shall
have a diameter 1/2″ (13 mm) larger than the vent diameter. The vent should be
centered in the opening.
Do not install screening or cap over the end of the vent.
24″ minimum (610 mm)
11
Multiple Dryer Venting A main vent can be used for venting a group of dryers.
The main vent should be sized to remove 200 CFM of air per dryer. Large-
capacity lint screens of proper design may be used in the main vent if checked
and cleaned frequently. The room where the dryers are located should have
make-up air equal to or greater than the CFM of all the dryers in the room. A
back-draft damper kit is needed and is available from a commercial laundry
distributor; it should be installed in the vent of each dryer to prevent
exhausted air from returning into the dryers and to keep the exhaust in
balance within the main vent. Unobstructed return air openings are required.
Each vent should enter the main vent at an angle pointing in the direction of
the airflow. Vents entering from the opposite side should be staggered to
reduce the exhausted air from interfering with the other vents.
The maximum angle of each vent entering the main vent should be no more than
30°.
Not Level
LEVEL
Not Level
2. Grip dryer from top and rock back and forth, making sure all four legs are firmly on floor. Repeat, rocking dryer from side to side. If dryer rocks, go to Step 3 and adjust leveling legs.
AirAfirloflwow
30° maximo
Keep air openings free of dry cleaning fluid fumes. Fumes create acids which,
when drawn through the dryer heating units, can damage dryers and items being
dried.
A clean-out cover should be located on the main vent for periodic cleaning of
the vent system. Leveling Leveling your dryer properly reduces excess noise
and vibration.
(appearance may vary)
3. If dryer is not level, use a 1″ or 25 mm open-end or adjustable wrench to
turn the leveling leg counterclockwise to lower the dryer or clockwise to
raise the dryer. Recheck levelness of dryer and that all four legs are firmly
in contact with the floor. Repeat as needed.
HELPFUL TIP: You may want to prop up front of dryer about 4″ (102 mm) with a wood block or similar object that will support weight of dryer.
1. Remove cardboard from beneath dryer. Place a level on top edges of dryer, checking each side and front. If not level, tip dryer and adjust legs up or down as shown in Step 3, repeating as necessary.
(appearance may vary)
12
INSTALLATION INSTRUCTIONS GAS DRYER
Make Gas Connection
WARNING
Explosion Hazard Use a new CSA International approved gas supply line. Install
a shut-off valve. Securely tighten all gas connections. If connected to
propane, have a qualified person make sure gas pressure does not exceed 13″
(33 cm) water column. Examples of a qualified person include: licensed heating
personnel, authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
1. Remove red cap from gas pipe. 2. Connect gas supply to dryer. Use pipe-
joint compound
resistant to the action of propane for gas connections. If flexible metal
tubing is used, be certain there are no kinks. If necessary for service, open
the toe panel by removing the 21/4″ hex-head screws from the bottom of the
panel. Then lift up on the panel while pulling the bottom of the panel away
from the dryer. 3. Open the shutoff valve in the gas supply line. 4. Test all
connections by brushing on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leak found.
Gas Supply Line Recommended method Provide a gas supply line of 1/2″ rigid
(IPS) pipe to the dryer
location. Pipe joint compounds that resist the action of Propane gas must be
used. Do not use TEFLON® tape. With Propane gas, piping or tubing size can be
1/2″ minimum. Usually, Propane gas suppliers determine the size and materials
used in the system.
Gas Supply Pressure Testing A 1/8″ (3 mm) NPT minimum plugged tapping, accessible for gauge testing, must be installed immediately downstream of the installed shut-off valve to the dryer (as shown above). The dryer must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2″ psig (352 kg/m2). The expected pressures for the gas supply are listed in inches of water in the table below:
Minimum Maximum
- Natural Gas 5.2″ (132.1 mm) 10.5″ (266.7 mm)
- Propane Gas 8.0″ (203.2 mm) 13.0″ (330.2 mm)
Alternate method The gas supply may also be connected using 3/8″ approved copper or aluminum tubing. If the total length of the supply line is more than 20 ft (6.1 m), larger tubing will be required. If using natural gas, do not use copper tubing. Pipe joint compounds that resist the action of Propane gas must be used.
Flexible metal appliance connector:
It is recommended that a new flexible stainless steel gas line, design-
certified by CSA International, be used for connecting the dryer to the gas
supply line. (The gas pipe, which extends through the lower rear of the dryer,
is provided with 3/8″male pipe thread.) Do not kink or damage the flexible
stainless steel gas line when moving the dryer. Rigid pipe connection: The
rigid pipe connection requires a combination of pipe fittings to obtain an in-
line connection to the dryer.
®TEFLON is a registered trademark of Chemours.
13
Must include a shutoff valve: The supply line must be equipped with a manual shutoff valve installed within 6 ft (1.8 m) of dryer in accordance with National Fuel Gas Code, ANSI Z223.1. In Canada, an individual manual shutoff valve must be installed in accordance with the B149 installation codes CAN/CGA B149.1 and CAN/CGA B149.2. This valve should be located in the same room as the dryer. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the dryer.
Complete Installation
1. With dryer in final position, place level on top of the dryer, first side
to side; then front to back. If the dryer is not level, adjust the legs of the
dryer up or down until the dryer is level.
2. Check the electrical requirements. Be sure that you have the correct
electrical supply and the recommended grounding method. See “Electrical
Requirements.”
3. Check that all parts are now installed. If there is an extra part, go back
through the steps.
4. Check that you have all of your tools. 5. Dispose of/recycle all packaging
materials.
WARNING
A. Gas supply line B. Shutoff valve in “open” position C. To dryer D. NPT 1/8″ minimum plugged tapping
Installed in a confined area:
If the dryer is installed in a confined area such as a bathroom or closet,
provision must be made for enough air for combustion and ventilation. Check
governing codes and ordinances or refer to the “Recessed Area and Closet
Installation Instructions” in the “Location Requirements” section.
Connect Vent
1. Using a 4″ (102 mm) clamp, connect vent to exhaust outlet on the dryer. If
connecting to existing vent, make sure the vent is clean. The dryer vent must
fit over the dryer exhaust outlet and inside the exhaust hood. Make sure the
vent is secured to exhaust hood with a 4″ (102 mm) clamp.
2. Using two or more people, move dryer to desired installation location. Do
not crush or kink vent, and remove any excess flexible vent to improve
airflow. Make sure dryer is level.
3. Check to be sure there are no kinks in the flexible gas line.
Electrical Shock Hazard
Plug into a grounded 3 or 4 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical
shock.
6. Plug into a grounded outlet, or connect power. 7. Check dryer operation:
Insert coins. Select a cycle. Using the WHITES & COLORS cycle, let the dryer
run for at least 5 minutes. Dryer will stop when time is used up. Note: Dryer
door must be closed for dryer to operate. When door is open, dryer stops, but
timer continues to run. To restart dryer, close door and reselect a cycle. 8.
If the burner does not ignite and there is no heat inside the dryer, shut off
dryer for 5 minutes. Check that all gas supply valves are in the “ON” position
and that the electrical cord is plugged in Repeat 5 minute test. 9. If drying
time is too long, make sure that the lint screen is clean and that there are
no obstructions to airflow in the dryer vent system.
14
INSTALLATION INSTRUCTIONS ELECTRIC DRYER
Power Supply Cord (U.S.A. Only)
1. Disconnect power. 2. Remove the hold-down screw and terminal block cover.
E A. Terminal block cover B. External ground
conductor screw
3. Install strain relief.
C. Center terminal block screw D. Hold-down screw E. Neutral ground wire
Electrical Connection Options If your location has: 4-wire receptacle (NEMA Type 14R-30R)
And you will be connecting to: A UL listed, 120 V/240 V minimum, 30 A, dryer power supply cord*
Go to Section 4-wire connection: Power supply cord
3-wire receptacle (NEMA type 10R-30R)
A UL listed, 120 V/240 V minimum, 30 A, dryer power supply cord*
3-wire connection: Power supply cord
4-wire direct 3-wire direct
(215″mm) (1275m” m)
31/2″ (89 mm)
A fused disconnect or circuit breaker box A fused disconnect or circuit breaker box
4-wire connection: Direct Wire 3-wire connection: Direct Wire
*If local codes do not permit the connection of a cabinet-ground conductor to the neutral wire, go to “Optional 3-wire connection” section.
15
Power supply cord strain relief: Remove the screws from a 3/4″ (19 mm)
UL listed strain relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block opening so that one tab
is pointing up and the other is pointing down, and hold in place.
Tighten strain relief screws enough to hold the two clamp sections together.
A
A. Strain relief tab pointing up
B. Hole below terminal
B
block opening
C. Clamp section
C
D. Strain relief tab
pointing down
D
Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
A. 4-wire receptacle (NEMA type 14R-30R) B. 4-prong plug C. Ground prong D. Neutral prong E. Spade terminals with upturned ends F. 3/4″ (19 mm) UL listed strain relief G. Ring terminals
1. Remove center terminal block screw (B).
2. Remove neutral ground wire (C) from external ground conductor screw (A).
Connect neutral ground wire and the neutral wire (white or center wire) of
power supply cord under center terminal block screw (B). Tighten screw.
A
C
Power supply cord, 4-wire connection:
IMPORTANT: A 4-wire connection is required for mobile homes and where
local codes do not permit the use of 3-wire connections.
A. External ground conductor screw – Dotted line shows position of NEUTRAL
ground wire before being moved to center terminal block screw.
B. Center terminal block screw C. Neutral ground wire D. Neutral wire (white
or center wire) E. 3/4″ (19 mm) UL listed strain relief
16
3. Connect ground wire (B) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw.
A. External ground conductor screw B. Ground wire (green or bare) of power
supply cord C. 3/4″ (19 mm) UL listed strain relief D. Center terminal block
screw E. Neutral ground wire F. Neutral wire (white or center wire)
4. Connect the other wires to outer terminal block screws. Tighten screws.
5. Tighten strain relief screws. 6. Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover with holddown screw. 7. You have
completed your electrical connection. Now go to “Venting Requirements.”
Power supply cord, 3-wire connection:
A. 3-wire receptacle (NEMA type 10R-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with upturned ends E. 3/4″ (19 mm) UL listed strain relief F. Ring terminals G. Neutral (white or center wire)
A. External ground conductor screw B. Neutral ground wire C. Center terminal
block screw D. Neutral wire (white or center wire) E. 3/4″ (19 mm) UL listed
strain relief Use where local codes permit connecting cabinet-ground conductor
to neutral wire. 1. Loosen or remove center terminal
block screw (C). 2. Connect neutral wire (white or center
wire) of power supply cord (D) to the center terminal screw (C) of the
terminal block. Tighten screw. 3. Connect the other wires to outer terminal
block screws. Tighten screws.
4. Tighten strain relief screws. 5. Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover with holddown screw. 6. You have
completed your electrical connection. Now go to “Venting Requirements.”
17
Direct Wire Method (U.S.A. Only)
Fire Hazard Use 10 gauge copper wire. Use a UL listed strain relief.
Disconnect power before making electrical connections. Connect neutral wire
(white or center wire) to center terminal. Ground wire (green or bare wire)
must be connected to green ground connector. Connect remaining 2 supply wires
to remaining 2 terminals (gold). Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
Direct wire strain relief: Unscrew the removable conduit
connector (A) and any screws from a 3/4″ (19 mm) UL listed strain relief (UL
marking on strain relief). Put the threaded section of the strain relief
through the hole (B) below the terminal block opening. Reaching inside the
terminal block opening, screw the removable conduit connector onto the strain
relief threads (C).
Direct wire cable must match power supply (4-wire or 3-wire) and be:
Flexible armored cable or nonmetallic sheathed copper cable (with ground
wire), protected with flexible metallic conduit. All current-carrying wires
must be insulated.
10-gauge solid copper wire (do not use aluminum).
At least 5 ft (1.52 m) long. 1. Disconnect power. 2. Remove hold-down screw
and terminal block cover.
A. Terminal block cover B. External ground
conductor screw
C. Center terminal block screw D. Hold-down screw E. Neutral ground wire
3. Install 3/4″ conduit connector into the hole below the terminal block
opening. Connect flexible metallic conduit and tighten connector screw.
Install direct wire cable through the flexible metallic conduit.
4. Complete installation following instructions for your type of electrical
connection:
· Four-wire (recommended method)
· Three-wire (if four-wire is not available)
Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
A. Removable conduit connector B. Hole below terminal block opening C. Strain
relief threads
18
4. Now complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Direct Wire, 4-wire connection: IMPORTANT: A 4-wire connection is required for
mobile homes and where local codes do not permit the use of 3-wire
connections. Direct wire cable must have 5 ft (1.52 m) of extra length so
dryer can be moved if needed. Strip 5″ (127 mm) of outer covering from end of
cable, leaving bare ground wire at 5″ (127 mm). Cut 11/2″ (38 mm) from 3
remaining wires. Strip insulation back 1″ (25 mm). Shape ends of wires into a
hook shape.
(251″mm)
(1275m” m)
When connecting to the terminal block, place the hooked end of the wire under
the screw of the terminal block (hook facing right), squeeze hooked end
together and tighten screw, as shown.
1. Remove center terminal block screw. 2. Remove neutral ground wire (C) from
external ground conductor screw (A). Connect neutral ground wire and place the
hooked end (hook facing right) of the neutral wire (white or center wire) of
direct wire cable (D) under the center screw (B) of the terminal block.
Squeeze hooked ends together. Tighten screw.
3. Connect ground wire (green or bare) of direct wire cable (B) to external ground conductor screw (A). Tighten screw.
A. External ground conductor screw B. Ground wire (green or bare) of power
supply cable C. 3/4″ (19 mm) UL listed strain relief D. Center terminal block
screw E. Neutral ground wire F. Neutral wire (white or center wire)
4. Place the hooked ends of the other direct wire cable wires under the outer
terminal block screws (hooks facing right). Squeeze hooked ends together.
Tighten screws.
5. Tighten strain relief screw. 6. Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover with holddown screw. 7. You have
completed your electrical connection. Now go to “Venting Requirements.”
A. External ground conductor screw – Dotted line shows position of NEUTRAL
ground wire before being moved to center terminal block screw.
B. Center terminal block screw C. Neutral ground wire D. Neutral wire (white
or center wire) E. 3/4″ (19 mm) UL listed strain relief
19
Direct wire, 3-wire connection:
Use where local codes permit connecting cabinet-ground conductor to neutral
wire. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can
be moved if needed. Strip 31/2″ (89 mm) of outer covering from end of cable.
Strip insulation back 1″ (25 mm). If using 3-wire cable with ground wire, cut
bare wire even with outer covering. Shape ends of wires into a hook shape.
(251″mm)
31/2″ (89 mm)
When connecting to the terminal block, place the hooked end of the wire under
the screw of the terminal block (hook facing right), squeeze hooked end
together, and tighten screw, as shown.
1. Loosen or remove center terminal block screw (C).
2. Place the hooked end of the neutral wire (white or center wire) of direct
wire cable (D) under the center screw of terminal block (hook facing right).
Squeeze hooked end together. Tighten screw.
A. External ground conductor screw B. Neutral ground wire C. Center terminal block screw D. Neutral wire (white or center wire) E. 3/4″ (19 mm) UL listed strain relief
20
3. Place the hooked ends of the other direct wire cable wires under the outer
terminal block screws (hooks facing right). Squeeze hooked ends together.
Tighten screws.
4. Tighten strain relief screw. 5. Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover with holddown screw. 6. You have
completed your electrical connection. Now go to “Venting Requirements.”
Optional, 3-wire connection: Use for direct wire or power supply cord where
local codes do not permit connecting cabinet-ground conductor to neutral wire.
- Remove center terminal block screw (B). 2. Remove neutral ground wire (C)
from
external ground conductor screw (A). Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable (D) under center terminal block screw. Tighten screw. 3. Connect the other wires to outer terminal block screws. Tighten screws.
4. Tighten strain relief screws. 5. Connect a separate copper ground
wire (F) from the external ground conductor screw (A) to an adequate ground. - Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with holddown screw.
Complete Installation
1. With dryer in final position, place level on top of the dryer, first side to side; then front to back. If the dryer is not level, adjust the legs of the dryer up or down until the dryer is level.
A. External ground conductor screw B. Center terminal block screw C. Neutral
ground wire D. Neutral wire (white or center wire) E. 3/4″ (19 mm) UL listed
strain relief F. Grounding path determined by a qualified
electrician
Connect Vent
F
Electrical Shock Hazard
Plug into a grounded 3 or 4 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical
shock.
2. Plug in dryer or reconnect power. 3. Check dryer operation:
Insert coins. Select a cycle. Using the WHITES & COLORS cycle, let the dryer
run for at least five minutes. Dryer will stop when time is used up. NOTE:
Dryer door must be closed for dryer to operate. When door is open, dryer
stops, but timer continues to run. To restart dryer, close door and reselect a
cycle. 4. If drying time is too long, make sure that the lint screen is clean,
and that there are no obstacles to airflow in the dryer vent system. 5. Now
start the dryer and allow it to complete a full cycle to make sure it is
working properly.
1. Using a 4″ (102 mm) clamp, connect vent to exhaust outlet in dryer. If
connecting to existing vent, make sure the vent is clean. The dryer vent must
fit over the dryer exhaust outlet and inside the exhaust hood. Make sure the
vent is secured to exhaust hood with a 4″ (102 mm) clamp.
2. Move dryer into final position. Do not crush or kink vent, and remove any
excess flexible vent to improve airflow. Make sure dryer is level.
21
REVERSING THE DOOR SWING
Door swing can be changed from a right-side opening to left-side opening, if
desired. Place a towel or soft cloth on top of the dryer or workspace to
prevent scratching the surface.
Remove the Door Assembly
1. Remove 3 of the 4 screws that hold the door hinge on the front panel of
the dryer. Partially loosen the remaining screw with keyhole opening and lift
the door off the screw.
A.
Reverse Hinge
1. Use a small flat-blade screwdriver to remove 2 plug strips from the inner
door. Slide the head of the screwdriver under the plugs, being certain not to
scratch the inner door surface. Lift up.
Loosen screw with keyhole opening
2. Remove the 4 screws that attach to the inner door hinge and move the hinge to the other side. Reinstall the 4 screws.
B.
A. Dryer front panel B. Door assembly
2. Lay the door assembly on a previously prepared flat surface with the
inside (inner door assembly) facing up.
3. Remove the 6 Phillips head screws to release the outer door assembly from
the inner door assembly, as indicated below. See illustration. It is important
that you remove only the 6 indicated screws.
Door hinge
3. Reinstall plug strips on opposite side of the inner door. 4. Check for
fingerprints on the glass. Clean glass if necessary. 5. Place the inner door
assembly inside the outer door
assembly. To fit correctly, the inner door assembly edge fits completely
inside the outer door assembly edge. 6. Reassemble the inner and outer door
assemblies with the 6 screws.
4. Lift the inner door assembly off the outer door assembly. 5. Rotate outer door 180°.
22
Reverse The Strike
1. Use a small flat-blade screwdriver to remove plug strip from the dryer
door opening. Slide the head of the screwdriver under the plugs, being certain
not to scratch the dryer surface. Lift the plastic strip from the dryer slowly
to prevent distortion of the plug strip.
2. Remove the strike using a Phillips screwdriver. 3. Insert strike on the
opposite side.
Reinstall The Door
1. Reattach door to dryer front panel with the 4 screws. Partially install
the screw with keyhole opening first, and fit the keyhole opening in the hinge
over the screw. Then install the remaining 3 screws and tighten all 4 screws.
A.
B. A.
A. Plug strip B. Door strike
Install this screw first
B.
A. Dryer front panel B. Door assembly 2. Check for fingerprints on the glass.
Clean glass if necessary. 3. Close door and check that it latches securely.
MAINTENANCE INSTRUCTIONS
Maintenance instructions:
Clean lint screen after each cycle.
Removing accumulated lint:
· From inside the dryer cabinet:
Lint should be removed every 2 years or more often, depending on dryer usage.
Cleaning should be done by a qualified person.
· From the exhaust vent:
Lint should be removed every 2 years, or more often, depending on dryer usage.
Keep area around dryer clear and free from combustible materials, gasoline,
and other flammable vapors and liquids.
Keep dryer area clear and free from items that would obstruct the flow of
combustion and ventilation air.
If dryer does not operate, check the following:
Electrical supply is connected. Circuit breaker is not tripped or house fuse
is not blown. Door is closed. Listen closely to hear the door switch activate.
Control is set up properly and display shows cycle time. Cycle selection
button has been pushed firmly. For gas dryers, check that gas supply shutoff
valves are set
in open position.
If you need assistance: Contact your authorized Maytag® Commercial Laundry
distributor. To locate your authorized Maytag® Commercial Laundry distributor,
or for web inquiries, visit
www.MaytagCommercialLaundry.com. If
you cannot locate your distributor, the Commercial Laundry Support Center will
answer any questions about operating or maintaining your dryer not covered in
the Installation Instructions. Just dial 1-800 NO BELTS
(1-800-662-3587)–the call is free. When
you call, you will need the dryer model number and serial number. Both numbers
can be found on the serial-rating plate located in the dryer door opening.
23
ELECTRONIC CONTROL SETUP
GENERAL USER INFORMATION Scrolling “out of order” showing in display, followed by a failure code This condition indicates the dryer is inoperative.
`0 Minutes’ showing in display This condition indicates the dryer cannot be operated. Coins dropped or debit inputs during this condition will be stored in escrow but cannot be used until normal operation is restored by opening and closing the door. If the door switch fails, it must be replaced before normal operation can be restored.
Cold Start (initial first use) Dryer is programmed at the factory as follows:
45 minutes dry time for PR models. 5 minutes per quarter for PD models.
$1.50 dry price (fixed cycle with top off PD Models).
$0.00 dry price (fixed cycle PR Models).
Warm Start (after power failure)
A few seconds after power is restored, if a cycle was in progress at the time
of the power failure, `RESELECT CYCLE’ will flash in the display. This is to
indicate the need for a fabric setting keypad to be pressed to restart dryer.
Pricing
After the door is opened and closed following the completion of a cycle, the
display indicates the cycle price (unless set for free operation). As coins or
debit inputs arrive, the display will change to lead the user through the
initiation of a cycle.
There are four (4) types of pricing:
Fixed Vend’ Pricing A dryer set up for
Fixed Cycle’ operation can only accept additional time
accumulated by increments equal to the length of a complete dry cycle. A
maximum of 75 minutes may be purchased; no additional credit is given when 75
minutes is in the display.
Accumulator Pricing
If the price is set to one coin 1, then accumulator mode is in effect. Cycle
time can be purchased one coin at a time (PD models) up to the maximum time of
75 minutes.
Fixed Cycle With Top Off Pricing
A dryer set to offer `Top Off’ capability will allow time to be added to an
existing dry cycle in increments equal to the number of minutes of dry time
per quarter (coin 1), up to 75 minutes, regardless of the cost required to
start the dryer. No credit is given for coins or debit inputs entered when the
control is displaying 75 minutes.
PR Models: In Enhanced Debit Mode, the top off price can be set independently (see VALUE OF COIN 2), and the top off time is calculated according to the following equation:
top off price full cycle price
=
top off time full cycle length
Penny increment offset is not applied to top off purchases.
Free Cycles
This is established by setting the cycle price to zero. When this happens,
`SELECT CYCLE’ will appear rather than a cycle price. Any cycle started as a
free cycle will automatically terminate when the door is opened.
Debit Card Ready
This dryer is debit card `cable’ ready. It will accept a variety of debit card
systems, but does NOT come with a debit card reader. Refer to the debit card
reader manufacturer for proper dryer set-up. In models converted to a
Generation 1 debit card system, debit pulses represent the equivalent of one
coin (coin 1).
24
CONTROL SET-UP PROCEDURES
IMPORTANT: Read all instructions before operating. The fabric setting
keypads along with the digital display are used to set-up the dryer controls.
The display can contain 4 numbers and/or letters and a decimal point. These
are used to indicate the set-up codes and related code values available for
use in programming the dryer.
How to use the keypads to program the controls 1. The WHITES & COLORS keypad
is used to adjust the
values associated with set-up codes. Pressing and releasing this keypad will
increment the value by one (1). Rapid adjustment is possible by holding the
keypad down.
2. The PERM. PRESS keypad will advance through the set-up codes. Pressing and
releasing this keypad will advance to the next available set-up code. Holding
the keypad down will automatically advance through the set-up codes at a rate
of one (1) per second.
3. The DELICATES keypad is used to select or deselect options.
Start Operating Set-Up
PD Models: Insert service access door key, turn, and lift to remove service
access door.
PR Models: Once a Gen. 2 debit card reader is installed (according to the
reader manufacturer’s instructions), the set-up mode can be entered by
inserting a manual set-up card (supplied by the reader manufacturer) into the
card slot. If manual set-up card is not available, manual set-up mode cannot
be entered. However, diagnostic mode can be entered by removing connector AA1
on the circuit board.
IMPORTANT: The console must not be opened unless power is first disconnected
from the dryer. To access connector AA1:
g Unplug dryer or disconnect power. g Open console, disconnect jumper on AA1,
close console. g Plug in dryer or reconnect power.
PR Models Set-up as PN can use the Service Access Code. This code can be
entered to access service mode without removing the console. It only functions
on dryers set up for 0 vend price without any Special Pricing set-up, and the
Coin/Debit Option must be set to “J._d”.
The alternative Service Access Code to enter set-up mode is: Press the left
keypad, right keypad, left keypad, right keypad, and right keypad.
The dryer is now in the set-up mode.
NOTE: Prior to operation, a payment system or an OPL kit must be installed.
Before proceeding, it is worth noting that, despite all the options available,
an owner can simply choose to uncrate a new commercial dryer, hook it up, plug
it in, and have a dryer that operates.
PD dryers have a factory default of fixed cycle price with top off.
PR dryers have a factory default of free cycle operation so they can be run
without readers or coins.
DISPLAY After the dryer has been installed and plugged in, the display will
show 0 minutes.’ Once the dryer has been plugged in and the dryer door opened and closed, the display will show the price. In PR models set for free cycles, the display will flash
SELECT CYCLE’ and the cycle time. PD Models
PRICE
PR Models
SET-UP CODES
The set-up code is indicated by the one or two left hand characters. The set-
up code value is indicated by the two or three right hand characters.
NOTE: The first line of each code indicates the factory default for PD models.
The set-up codes for PR models are the same except where noted.
CODE
EXPLANATION
6 0 6 REGULAR CYCLE PRICE
60 6
Represents the number of quarters (coin 1) needed to start the dryer; may adjust from 0-39 (See b.xx set-up for VALUE OF COIN 1). Advance from 0-39 by pressing WHITES & COLORS. Factory default of 6 quarters = $1.50.
6 0 0 PR MODELS: Factory default of 6 00, or 0 quarters.
g Press PERM. PRESS keypad once to advance to next code.
7 0 5 REGULAR DRY TIME
7 0 5 PD MODELS: Represents the number of minutes per quarter (coin 1).
Factory default of 5 minutes per coin Example: 6 quarters x 5 minutes = 30 minutes.
By pressing the WHITES & COLORS keypad, value adjusts from 1-75 minutes.
7 4 5 PR MODELS: Represents the cycle length for free cycles.
As example: `7 45′ = 45 minutes.
g Press PERM. PRESS keypad once to advance to next code.
8 0 0 TYPE OF DRYER PRICING
8 0 0 Fixed Cycle with Top Off. For detailed description, see General User
Information.
8 f c PR MODELS ONLY: Factory default of FC. Fixed Cycle.
For detailed description, see General User Information.
Use DELICATES keypad to make this selection.
g Press PERM. PRESS keypad once to advance to next code.
900
CYCLE COUNTER OPTION This option is either Selected ON’ or Not Selected
OFF’.
9 0 0 Not Selected `OFF’.
90c
Selected ON’ and not able to be deselected. Press DELICATES keypad 3 consecutive times to select
ON’. Once selected `ON’ it cannot be deselected.
g Press PERM. PRESS keypad once to advance to next code.
CODE
EXPLANATION
1. 0 0
MONEY COUNTER OPTION This option is either Selected ON’ or Not Selected
OFF’.
1. 0 0 Not Selected `OFF’.
1. 0 c Selected `ON’.
Press DELICATES keypad 3 consecutive times to select ON’ and 3 consecutive times to remove (Not Selected
OFF’.) Counter resets by going from OFF’ to
ON’.
1. c0 Selected `ON’ and not able to be deselected.
To select ON’ and not able to be deselected, first select
ON’, then within
two seconds press DELICATES twice, WHITES & COLORS once, and exit the set-up
mode.
g Press PERM. PRESS keypad once to advance to next code.
2. 0 0
SPECIAL PRICING OPTIONS This option is either Selected ON’ or Not Selected
OFF’.
2. 0 0 Not Selected `OFF’.
2.s p
Selected `ON’. Press DELICATES keypad once for this selection.
If SPECIAL PRICING OPTION is selected, there is access to codes 3.’ through
9.’
g Press PERM. PRESS keypad once to advance to next code.
OPTIONS TO USE IF SPECIAL PRICING IS SELECTED:
3. 0 6 SPECIAL CYCLE PRICE
3. 0 6
Represents the number of quarters (coin 1) needed to start the dryer; may adjust from 0-39. (See b.xx set-up for VALUE OF COIN 1). Advance from 0-39 by pressing WHITES & COLORS. Factory default of 6 quarters = $1.50.
3. 0 0 PR MODELS: Factory default of 0 quarters.
g Press PERM. PRESS keypad once to advance to next code. 4. 0 5 SPECIAL DRY TIME
4. 0 5 PDMODELS: Represents the number of minutes per quarter (coin 1).
Factory default of 5 minutes per coin Example: 6 quarters x 5 minutes = 30 minutes.
By pressing the WHITES & COLORS keypad, the value can be adjusted from 1-75 minutes.
4. 4 5 PR MODELS: Represents the fixed cycle time in minutes.
As example: `4 45′ = 45 minutes.
g Press PERM. PRESS keypad once to advance to next code. 5. 0 0 TIME-OF-DAY
CLOCK, MINUTES
5. 0 0
This is the TIME-OF-DAY CLOCK, minute setting; select 0-59 minutes by pressing WHITES & COLORS keypad.
g Press PERM. PRESS keypad once to advance to next code.
6. 0 0 TIME-OF-DAY CLOCK, HOURS
NOTE: Uses military time 24 hour clock.
6. 0 0 This is the TIME-OF-DAY CLOCK, hour setting; select
0-23 hours by pressing WHITES & COLORS keypad.
g Press PERM. PRESS keypad once to advance to next code.
25
CODE
EXPLANATION
OPTIONS TO USE IF SPECIAL PRICING IS SELECTED (continued):
7. 0 0 SPECIAL PRICE START HOUR
NOTE: Uses military time 24 hour clock.
7. 0 0 This is the start hour, 0-23 hours. Select START HOUR
by pressing WHITES & COLORS keypad.
g Press PERM. PRESS keypad once to advance to next code.
8. 0 0 SPECIAL PRICE STOP HOUR
NOTE: Uses military time 24 hour clock.
8. 0 0 This is the stop hour; 0-23 hours. Select STOP HOUR
by pressing WHITES & COLORS keypad.
g Press PERM. PRESS keypad once to advance to next code.
9. 1 0 SPECIAL PRICE DAY
9. 1 0
This represents the day of the week and whether special pricing is selected
for that day. A number followed by 0′ indicates no selection that particular day (9.10). A number followed by an
S’ indicates selected for that day
(9.1S).
Days of week (1-7) can be chosen by pressing the WHITES & COLORS keypad. Press
DELICATES keypad once to select special pricing for each day chosen.
When exiting setup code `9.’, the display must show current day of week:
DISPLAY DAY OF WEEK
CODE (selected)
10
Day 1 = Sunday
1S
20
Day 2 = Monday
2S
30
Day 3 = Tuesday
3S
40
Day 4 = Wednesday
4S
50
Day 5 = Thursday
5S
60
Day 6 = Friday
6S
70
Day 7 = Saturday
7S
g Press PERM. PRESS keypad once to advance to next code.
a. 0 0
VAULT VIEWING OPTION This option is either Selected ON’ or Not Selected
OFF’.
a.0 0 Not Selected `OFF’.
a.sc
Selected `ON’. Press DELICATES keypad once for this selection. When selected, the money and/or cycle counts will be viewable (if counting is selected) when the coin box is removed.
g Press PERM. PRESS keypad once to advance to next code.
6. 0 5 VALUE OF COIN 1
6. 0 5
This represents the value of coin 1 in number of nickels. 05 = $0.25.
By pressing WHITES & COLORS keypad, there is the option of 1-199 nickels.
With coin slide activation, this represents the total vend price in nickels. Example: b.30 = $1.50.
g Press PERM. PRESS keypad once to advance to next code.
c. 2 0 VALUE OF COIN 2
c. 2 0
PD MODELS: This represents the value of coin 2 in number of nickels. 20 = $1.00.
By pressing WHITES & COLORS keypad, there is the option of 1-199 nickels.
c. 0 5
PR MODELS: For models using Enhanced Debit, this field represents the value of top off in nickels, or $.25.
Factory default of C.05; represents 5 x $.05, or $.25.
g Press PERM. PRESS keypad once to advance to next code.
26
CODE
EXPLANATION
8. 0 0
COIN SLIDE OPTION This option is either Selected ON’ or Not Selected
OFF’.
Replacement of metercase will be needed for coin slide mounting.
8. 0 0 Not Selected `OFF’.
8. cs Selected `ON’.
NOTE: This option needs to be set to `00′ unless the metercase has been changed to accept a coin slide device.
Press DELICATES keypad 3 consecutive times for this selection. When coin slide
mode is selected, set b.’ equal to value of vend price in nickels. Set
6 XX’
(REGULAR CYCLE PRICE) and `3.XX’ (SPECIAL CYCLE PRICE) to number of slide
operations.
NOTE: If the installer sets up `CS’ on a coin drop model, the dryer will not register coins inserted.
g Press PERM. PRESS keypad once to advance to next code.
e. 0 0
ADD COINS OPTION This option is either Selected ON’ or Not Selected
OFF’.
This option causes the customer display to show the number of coins (coin 1)
to enter, rather than the dollars-and-cents amount.
e. 0 0 Not Selected `OFF’.
e. a c Selected `ON’.
Press DELICATES keypad 3 consecutive times for this selection.
PR MODELS: In enhanced debit mode, this option is not selectable.
g Press PERM. PRESS keypad once to advance to next code.
j.c8 COIN/DEBIT OPTION
j. c8
Both coin & debit selected. Press DELICATES keypad 3 consecutive times to change this selection.
j. c8
Coins selected, debit disabled. Press DELICATES keypad 3 consecutive times to change this selection.
j. c8
Debit Card selected, coin disabled. This is the factory default for PR models.
PR SET UP AS PN MODELS ONLY: Must be set for `_d.’
Press DELICATES keypad 3 consecutive times to change this selection.
j. e8
Enhanced debit is self-selected when a Generation 2 card reader is installed in the dryer. The `Ed’ option cannot be manually selected or deselected.
g Press PERM. PRESS keypad once to advance to next code.
l.0 0 l.0 0
PRICE SUPPRESSION OPTION This option is either Selected ON’ or Not Selected
OFF’. This option causes the customer display to show AVAILABLE’ or
ADD’
rather than the amount of money to add. (Used mainly in debit installations.)
Not Selected `OFF’.
l. p s Selected `ON’. Press DELICATES keypad once for this selection.
g Press PERM. PRESS keypad once to advance to next code.
8. ce
CLEAR ESCROW OPTION This option is either Selected ON’ or Not Selected
OFF’.
When selected, money held in escrow for 30 minutes without further escrow or
cycle activity will be cleared.
8. ce Selected `ON’.
8.0 0 Not Selected `OFF’. Press DELICATES keypad once to deselect this
option.
g Press PERM. PRESS keypad once to advance to next code.
0. 0 0 PENNY INCREMENT OFFSET
0. 0 0
This represents the penny increment price offset used in Generation 2 (Enhanced Debit) PR models. Choose from 0-4 pennies by pressing the WHITES & COLORS keypad.
g Press PERM. PRESS keypad once to advance to next code.
If cycle counter (9 0C) is selected, the following is true:
1 00 Represents the number of cycles in HUNDREDS. 1 02 = 200
2 00 Represents the number of cycles in ONES.
2 25 = 225
TOTAL CYCLES = 225
This is `VIEW ONLY’ and cannot be cleared.
Press the PERM. PRESS button once to advance to next code.
If money counter (1.0C or 1.C0) is selected, the following is true:
3 00 Number of dollars in HUNDREDS.
3 01 = 100.00
4 00 Number of dollars in ONES.
4 68 = 168.00
5 00 Number of CENTS.
5 75 = 100.75
TOTAL = $168.75
END OF SET-UP PROCEDURES
EXIT FROM SET-UP MODE
PD MODELS: Reinstall service access door.
PR MODELS: Remove set-up card.
PR MODELS where AA1 connector was removed: 1. Unplug dryer or disconnect
power. 2. Open console, reinsert jumper into AA1, close console. 3. Plug in
dryer or reconnect power.
PR MODELS WHERE SERVICE ACCESS CODE WAS USED: Set-up mode can be exited by
using procedures from Service Access Code (see page 24).
g Wait for 2 minutes without activating any dryer inputs. g Disconnect and
then re-connect power.
27
MAYTAG® COMMERCIAL WASHER, DRYER, STACKED DRYER/DRYER, COMMERCIAL STACK
LAUNDRY, AND MULTI-LOAD COIN OPERATED COMMERCIAL WASHERS AND DRYERS WARRANTY
LIMITED WARRANTY (PARTS ONLY LABOR NOT INCLUDED)
For the first five years from the original date of purchase, when this
commercial appliance is installed, maintained, and operated according to the
instructions attached to or furnished with the product, Maytag brand of
Whirlpool Corporation (hereafter “Maytag”) will pay for factory specified
replacement parts to correct defects in materials or workmanship that existed
when this commercial appliance was purchased. This limited warranty does not
include labor.
YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT
REPAIR AS PROVIDED HEREIN. Maytag recommends that you use an “in network”
service provider to diagnose and repair your Commercial Laundry product.
Maytag will not be responsible under this warranty to provide additional
replacement parts as a result of incorrect diagnosis or repair by an “out of
network” service company. This limited warranty is valid in the United States
or Canada and applies only when the commercial appliance is used in the
country in which it was purchased. This limited warranty is effective from the
date of the original consumer purchase. Proof of original purchase date is
required to obtain service under this limited warranty.
This limited warranty does not cover:
ITEMS EXCLUDED FROM WARRANTY
1. All other costs including labor, transportation, shipping, or custom duties for covered parts.
2. Factory specified replacement parts if this commercial appliance is used for other than normal, commercial use or when it is used in a manner that is inconsistent to published user or operator instructions and/or installation instructions.
3. Service calls to correct the installation of your commercial appliance, to instruct you on how to use your commercial appliance, to replace or repair house fuses, or to correct external wiring or plumbing.
4. Damage resulting from improper handling of product during delivery, theft, accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, installation not in accordance with local electrical or plumbing codes, or use of products not approved by Maytag.
5. Pick up and delivery. This commercial appliance is designed to be repaired on location.
6. Repairs to parts or systems resulting from unauthorized modifications made to the commercial appliance.
7. The removal and reinstallation of your commercial appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions.
8. Damage resulting from exposure to chemicals.
9. Changes to the building, room, or location needed in order to make the commercial appliance operate correctly.
10. Factory specified replacement parts on commercial appliances with original model/serial numbers that have been removed, altered, or cannot be easily determined.
11. Discoloration, rust, or oxidation of stainless steel surfaces.
12. Factory specified replacement parts as a result of incorrect diagnosis or repair by an “out of network” service company.
The cost of repair or replacement under these excluded circumstances shall be borne by the customer.
DISCLAIMER OF IMPLIED WARRANTIES
IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR
OR THE SHORTEST PERIOD ALLOWED BY LAW. Some states and provinces do not allow
limitations on the duration of implied warranties of merchantability or
fitness, so this limitation may not apply to you. This warranty gives you
specific legal rights, and you also may have other rights that vary from state
to state or province to province.
DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY
Maytag makes no representations about the quality, durability, or need for
service or repair of this commercial appliance other than the representations
contained in this Warranty. If you want a longer or more comprehensive
warranty than the limited warranty that comes with this commercial appliance,
you should ask Maytag or your retailer about buying an extended warranty.
LIMITATION OF REMEDIES; EXCLUSION OF INCIDENTAL AND CONSEQUENTIAL DAMAGES
YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT
REPAIR AS PROVIDED HEREIN. MAYTAG SHALL NOT BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES. Some states and provinces do not allow the exclusion or
limitation of incidental or consequential damages, so these limitations and
exclusions may not apply to you. This warranty gives you specific legal
rights, and you also may have other rights that vary from state to state or
province to province.
If you need service, please contact your authorized Maytag Commercial Laundry® distributor. To locate your authorized Maytag Commercial Laundry® distributor, call 1-800-662-3587, or for web inquiries, visit www.MaytagCommercialLaundry.com. For written correspondence: Maytag Commercial Laundry® Service Department 2000 N M 63 Benton Harbor, Michigan 49022-2632 USA 28
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>