LOCK CHOICE BS-35 Keypad Access Control User Manual

October 29, 2023
LOCK CHOICE

LOCK CHOICE BS-35 Keypad Access Control

Description

The device is a standalone access control and proximity card reader which supports EM & MF card types. It builds-in STC microprocessor, with strong anti-interference ability,high security and reliability,powerful function and convenient operation. It’s widely used in high-end buildings, residential communities and other public places.

Features

Ultra-low Power Standby current is less than 30mA
Wiegand Interface WG26 or WG34 input and output
Searching time Less than 0.l s after reading card
Backlight keypad Operate easily at night
 
Access ways Card, Pin code, Card & Pin code, APP on the phone.
Independent codes Use codes without related card
Change codes Users can change codes by themselves
Delete users by card No. The lost card can be delete by keyboard

Specifications

Working Voltage: DC12-24V Standby Current: :530mA
Card Reading Distance: 1~ 3cm Capacity: 2000 users
Working Temperature: -40°C ~ 60°C Working Humidity: 10%~ 90%
Lock output load: :53A Door Relay time: 0~ 99S (Adjustable)

Installation

Drill hole according to the size of the device and fix the back shell with the equipped screw.Thread the cable through the cable hole. connect the wires according to your required function, and wrap the unused wires to avoid short circuit. After connecting the wire, install the machine. (as show below)

Wiring

Color ID Description
Green DO Wiegand lnput(Wiegand Output in Card Reader Mode)
White Dl Wiegand lnput(Wiegand Output in Card Reader Mode)
Yellow OPEN Exit Button input terminal
Red +12V 12V + DC Regulated Power Input
Black GND 12V – DC Regulated Power Input
Blue NO Relay normally-on terminal
Purple COM Relay Public terminal
Orange NC Relay normally-off terminal

Diagram

Common Power Supply

Diagram

Special Power Supply

Diagram

Reader Mode

Sound & Light indication

Operate Status LED Light Color Buzzer
Standby Red
Keypad   Beep
Operation Successful Green Beep-
Operation Failed   Beep-Beep-Beep
Entering into Programming Flash Red Slowly Beep –
Programmable Status Orange
Exit Programming Red Beep-
Door Opening Green Beep-

Advance setting

Master Card Operation

Master Card Operation