FRICO SCV21DCI Soloclim Vertical Air Conditioner Instruction Manual
- June 10, 2024
- FRICO
Table of Contents
FRICO SCV21DCI Soloclim Vertical Air Conditioner
Soloclim vertical
The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages.
DIMENSIONS
The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages
Components
Fig.1
- Touch screen control panel
- Air outlet deflector
- Front panel
- Intake grille
- Side panel
- External air outlet
- External air intake
- Condensate drain tube
- Anchor bracket
- Data label
- Terminal block
- Air filter
- Room temperature sensor
Included in delivery
Fig.2
A. Outside grilles for air inlet and outlet (2 pcs) Fig.6
B. Screws and plugs kit (6 pcs)
C. Wall mounting bracket
D. Manual
E. Remote control
F. Paper drilling template Fig.4
G. CR2025 3V remote control battery
H. Plastic sheet for wall duct (2 pcs) Fig.5
I. Energy efficiency label
J. Inside flanges for air inlet and outlet (2 pcs)
Fig.3 Minimum distances
A. Holes for M8 plugs
B. Ø162 mm hole for outlet air duct
C. Ø162 mm hole for inlet air duct
D. Ø18 mm condensate drain back
E. Ø18 mm condensate drain base
F. Electrical connection
G. Holes for anchor bracket
H. Bottom of the unit
I. Floor
Drilling template
Fig.5 Air ducts
Plastic sheets for air ducts
Wall grilles
A. Chain
B. Flange
C. Spring
D. Outside air grill
Mounting the unit
Release the compressor before start up
- Wall bracket
- Interlocking points
- Anchor brackets
Drainage
Fig.8
- Drainage tube 0,6 m (Ø18 mm outside, Ø13 mm inside)
- Safety drain
Fig.8b
Opening the unit / Access to the terminal block
Fig.9
Wiring diagram
GR Grey
BR Brown
YG Yellow-Green
BL Blue
CP Presence contact
N Neutral
L Phase
IG System main switch
PE Earth connection
Accessories
Art. no | Type | WxHxD [mm] |
---|---|---|
282045 | SCKEG162 | 180x180x20 |
282046 | SCRPK | 230x120x170 |
-
SCKEG162
-
SCRPK
Technical specifications
Art. no Type| Cooling output1 [kW]| Heat output1 [kW]| EER| COP| Voltage
[V]| Refrigerant| WxHxD
[mm]| Weight*2
[kg]
---|---|---|---|---|---|---|---|---
999925
SCV21DCI| 2,04| 2,10| 2,72| 3,10| 230V~| R410a| 500x1398x185| 57
999926
SCV23DCI| 2,35| 2,36| 2,75| 3,15| 230V~| R410a| 500x1398x185| 57
*1* ) According to standard EN 14511
2** ) Weight without refrigerant
| SCV21DCIN| SCV23DCIN
---|---|---
Cooling| |
Max. cooling output Dual Power 3| kW| 2,60| 3,11
Nominal cooling output 3| kW| 2,04| 2,35
Min. cooling output 4| kW| 0,81| 0,92
Dehumidification capacity| l/24h| 0,80| 0,90
Total power consumption 3| kW| 0,75| 0,85
Heating| |
Max. heat output Dual Power 4| kW| 2,64| 3,05
Nominal heat output 4| kW| 2,10| 2,36
Min. heat output 4| kW| 0,68| 0,79
Total power consumption 4| kW| 0,65| 0,75
| |
Max. absorbed current| A| 4,10| 4,60
Air flow at max fan speed in/out| m³/h| 380/460| 400/480
Air flow at med fan speed in/out| m³/h| 310/380| 320/390
Air flow at min fan speed in/out| m³/h| 260/330| 270/340
**Max/Min sound pressure* 5**| dB(A)| 39/26| 41/27
3 ) Outdoor air temperature 35 °C, relative humidity 41%. Ambient temperature 27 °C; relative humidity 47%.
4 ) Outdoor air temperature 7 °C; relative humidity 87%. Ambient temperature 20 °C; relative humidity 59%.
*5 ) Indoor sound pressure measured in semi-anechoic chamber at a distance of 2 m.
Max work conditions
Cooling temperature, (indoor/outdoor, Dry Bulb) ; minimum 18 °C/-5 °C, maximum
32 °C/43 °C
Heating temperature, (indoor/outdoor, Dry Bulb) ; minimum 5 °C/-10 °C, maximum
25 °C/18 °C
Energy classification according to the directive 626/2011
Energy efficiency class cooling/heating: A.